AMG and Associates Inc (Change Order 005)City of Rancho Palos Verdes Department of Public Works 30940 Hawthorne Blvd, Rancho Palos Verdes, CA 90275 (310)544-5252 www.publicworks@riDvca.gov CHANGE ORDER MEMORANDUM TO: RAMZI AWWAD, DIRECTOR OF PUBLIC WORKS FROM: ERIN JONES, GRIFFIN STRUCTURES DATE: SEPTEMBER 1, 2022 SUBJECT: LADERA LINDA COMMUNITY PARK CONSTRUCTION CHANGE ORDER NUMBER: 5 Description of Construction Change Order Credit to use no -hub plumbing pipe fittings for below -grade sewer and storm drain lines, per RFI 14. Justification The contractor requested to use no -hub 4 -band pipe couplings for their own ease of installation. Cost Analysis The contractor estimated a time savings of 20 hours, at the published prevailing wage plumbing rate. Schedule Analysis No time extension was requested by the contractor, and work is expected to be completed within the original construction timeframe. Attachments: Construction Contract Change Order Form Construction Contract Change Order Summary Sheet Contractor's Change Order Proposal City of Rancho Palos Verdes Department of Public Works 30940 Hawthorne Blvd, Rancho Palos Verdes, CA 90275 14L(310)544-5252 www. ublicworks r vca. ov CONSTRUCTION CHANGE ORDER SUMMARY SHEET PROJECT NAME: Ladera Linda Community Park PROJECT CODE: 8405 PREPARED BY: JAMES O'NEILL CONTRACTOR NAME: AMG & Associates, Inc. CONTRACT NUMBER: FY2022-050 PURCHASE ORDER NUMBER: 20220215 ACCOUNT NUMBER: 330-400-8405-8403 ORIGINAL CONTRACT AMOUNT: $13,721,000.00 TOTAL CHANGE ORDERS COST: $123,869.52 DATE: 09/01/22 ORIGINAL CONTINGENCY AMOUNT: $1,029,075.00 NEW CONTRACT AMOUNT: $13,844,869.52 REMAINING CONTINGENCY AMOUNT: $905,205.48 ORIGINAL COMPLETION DATE: 07/27/23 TOTAL SCHEDULE CHANGE ORDERS: 11 Working Days NEW CONTRACT COMPLETION DAVE: 08/11/23 CHANGE ORDER NUMBER COST AMOUNT SCHEDULE EXTENSION DATE C0#1 $54,534.52 0 Working Days 05/27/22 CO#2 $12,628.58 0 Working Days 08/09/22 CO#3 $53,526.25 11 Working Days 08/31/22 CO#4 $8,558.42 0 Working Days 09/01/22 CO#5 -$5,378.25 0 Working Days 09/01/22 CO#6 Working Days CO#7 Working Days CO#8 Working Days CO#9 lWorking Days C0#10 1working Days Iof1 City of Rancho Palos Verdes Department of Public Works LA 30940 Hawthorne Blvd, Rancho Palos Verdes, CA 90275 (310)544-5252 www.pu1blicworksCcDrpvca.gov CONSTRUCTION CHANGE ORDER FORM CONTRACT NUMBER. FY2022-050 PURCHASE ORDER NUMBER 20220215 CHANGE ORDER NUMBER: 5 CONTRACTOR NAME: AMG & Associates, Inc. DESCRIPTION AND LOCATION OF PROPOSED WORK PROJECT NAME: Ladera Linda Community Park PROJECT CODE: 8405 DATE: 09/01/22 Credit to use no -hub plumbing pipe fittings for below -grade sewer and storm drain lines, per RFI 14. SUMMARY OF QUANTITY CHANGES ITEM NO. SPEC CODE DESCRIPTION ORIGINAL QUANTITY NEW QUANTITY QUANTITY DIFFERENCE UNIT PRICEFDIFFERENCE7WOFR;KING PRICEDITIONAL DAYS AMG PCO 3 - RFI 14 Credit to use no -hub 1 220500 pipe fittings 0.0 LS 1.0 LS 1.0 LS -$5,378.25 -$5,378.25 0 0 0.0 0 $0.00 0 0.0 0 $0.00 0 0.0 0 $0.00 0 0.0 0 $0.00 0 0.0 0 $0.00 Totals -$5,378.25 0 A TIME EXTENSION OF 0 WORKING DAYS WILL BE ALLOWED FOR THIS WORK ORIGINAL CONTRACT AMOUNT: $13,721,000.00 ORIGINAL COMPLETION DATE: 07/27/23 TOTAL OF CHANGE ORDER #1-4-1$129,247.77 TOTAL OF TIME EXTENSIONS #1-0:1 11 Working Days TOTAL OF CHANGE ORDER #571($6,378.25) TOTAL OF TIME EXTENSIONS #5:1 0 Working Days NEW CONTRACT AMOUNT: $13,844,869.52 NEW COMPLETION DATE: 08!11/23 1 of 2 City of Rancho Palos Verdes Department of Public Works LA 30940 Hawthorne Blvd, Rancho Palos Verdes, CA 90275 (310)544-5252 www.publicworks@rpvc-l.Qoy_ CONSTRUCTION CHANGE ORDER FORM CONTRACT NUMBER: FY2022-050 PURCHASE ORDER NUMBER: 20220215 CHANGE ORDER NUMBER: 5 CONTRACTOR NAME: AMG & Associates, Inc. PROJECT NAME: Ladera Linda Community Park PROJECT CODE: 8405 By signing this Change Order, Contractor understands and agrees that it is accepting the specified sums and adjustment of contract time of completion (if any) set forth herein as full, final and complete satisfaction of any and all claims by Contractor for all costs and expenses of Contractor and anyone for whom Contractor may be responsible for the work referred to herein, including but not limited to costs or expenses of the Contractor or any of its subcontractors, materials suppliers, vendors or anyone else for whom Contractor is responsible, for labor, materials, services or equipment, no matter how characterized, whether known or unknown to Contractor, including but not limited to, all field and home office overhead, delay costs/claims, acceleration costs/claims, unabsorbed or under -absorbed home office overhead, extended field costs, general conditions, claim preparation costs, inefficiencies, or the like, no matter how characterized. Contractor further understands and agrees by signing this Change Order that any attempt by Contractor to purportedly reserve rights to claim additional time or compensation for the work referred to herein, is void. Except as set forth, all terms and provisions of the contract and all prior change orders remain in full force and effect. Recommended Erin Jones Date: 09/01/22 Construction Manager, Griffin Structures Signature Execution of this Change Order by both parties constitutes a binding agreement. This document constitutes the entire agreement between the parties. The person signing this Change Order for Contractor hereby represents and warrants that he/she is fully authorized to sign this Agreement on behalf of Contractor. Digitally signed by Anthony R. Anthony R. Traverso Traverso Contractor: Anthony R. Traverso Date: 2022.09.0610:02:56-07'00' Date: Vice President/Secretary/Treasurel Signature Accepted and Executed by: Date:�- Oatu®rZ, City: Ramzi Awwad Contractor Officer Date: C) 1 d Z— Ramzi Awwad Public Works Director Trang Nguyen 111, Date: Finance Director Si nat r 2 of 2 AG AMG & Associates Inc 26535 Summit Circle Santa Clarita, California 91350 Phone: (661)251-7401 Fax: (661) 251-7405 PCO #003 Project: 01-22-157 - Ladera Linda Community Center and Park 32201 Forrestal Dr. Rancho Palos Verdes, California 90275 Prime Contract Potential Change Order #003: CE #017 - RFI #14 Underground Cast Iron Pipes Amount TO: City of Rancho Palos Verdes FROM: AMG & Associates, Inc. 30940 Hawthorne Blvd. 26535 Summit Circle Rancho Palos Verdes, California 90275 Santa Clarita, California 91350 PCO NUMBERIREVISION: 003/1 CONTRACT: City Project No. 8405 - Ladera Linda $(75.00) Community Park Project REQUEST RECEIVED FROM: Edric Jafari (ABO Inc.) CREATED BY. Christopher Tumasone (AMG & $(5,378.25) Associates, Inc.) STATUS: Pending - In Review CREATED DATE: 6/6/2022 REFERENCE: PRIME CONTRACT None CHANGE ORDER: FIELD CHANGE: No LOCATION: ACCOUNTING METHOD: Amount Based SCHEDULE IMPACT: PAID IN FULL: No EXECUTED: No SIGNED CHANGE ORDER RECEIVED DATE: TOTAL AMOUNT: ($5,378.25) POTENTIAL CHANGE ORDER TITLE: CE #017 - RFI #14 Underground Cast Iron Pipes CHANGE REASON: POTENTIAL CHANGE ORDER DESCRIPTION: (The Contract Is Changed As Follows) CE #017 - RFI #14 UndcEgownd Cast Iron Pines ATTACHMENTS: PCo_AO ,[ C ,#14 UU defground �§t Iron i es.._f � Casl Prap0sa1_ (002).pdf # Budget Code Description Amount 115-100.S Plumbing.Commitment cost proposal per RFI 14 $(5,000.00) Subtotal: $(5,000.00) Overhead (5.00% Applies to all line item types,): $(250.00) Insurance (1.50% Applies to all line item types.): $(75.00) Bonding (1.00% Applies to all line Item types.): $(53.25) Grand Total: $(5,378.25) SIGNATURE AMG & Associates Inc. DATE City of Rancho Palos Verdes AMG & Associates, Inc. 30940 Hawthorne Blvd. 26535 Summit Circle Rancho Palos Verdes, California 90275 Santa Clarita, California 91350 SIGNATURE DATE SIGNATURE DATE Page 1 of 1 Printed On: 8/9/2022 12:08 PM ABQ INC. June 2, 2022 AMG & ASSOCIATES Attn: Chandra Sutton LIC #: 1081727 - C36 DIR #: 1000833272 Office: (310) 299-6251 Cell: (818) 921-5152 Email: Info(&abgla.com Project: Ladera Linda Community Center and Park 32201 Forrestal Dr. Rancho Palos Verdes, California 90275 Cost ProQosal Below is the cost saving proposal breakdown for couplings that will be used for sewer and storm drain. Please note this is an approximate, as we have not started the project. Description U 1 Plumber for 20 hours at $80.58 an hour. (Approximately) Material Total Cost Savings 6200 Canoga Ave #205, Woodland Hills, CA 91367 Cost $1,611.60 $3,388.40 $5,000.00 - -- RFI #14 AMG & Associates Inc. Project: 01-22-157 - Ladera Linda Community Center and Park 26535 Summit Circle 32201 Forrestal Dr. Santa Clarita, California 91350 Rancho Palos Verdes, California 90275 Phone: (661) 251-7401 Fax: (661) 251-7405 This is in regarding the installation of below grade cast iron pipes for sewer and stone drain utility lines. We propose to use No -Hub pipe with heavy duty with heavy duty, 4- band coupling which provides a stronger connection. That type of connection is commonly used in both below grade and above grade applications. Please advise Attachments: BY DATE COPIES TO AMG & Associates Inc. Page 1 of 1 Printed On: 05/11/2022 07:33 AM Underground Cast Iron Pipes TO: Christopher Tumasone (AMG & Associates, Inc.) FROM: Chandra Sutton (AMG & Associates, Inc.) 26535 Summit Circle 26535 Summit Circle Santa Clarita, California 91355 Santa Clarita, California 91350 CREATED DATE: 05/11/2022 STATUS: Open LOCATION: DUE DATE: 05/26/2022 COST CODE: REFERENCE: ABO RFI 1 COST IMPACT: TBD SCHEDULEIMPACT TBD DRAWING NUMBER: SPEC SECTION: RECEIVED FROM: Edric Jafari (ABO Inc.) COPIES TO: Dustin Hartman (AMG & Associates, Inc.), Randy Hartman (AMG & Associates, Inc.), Anthony Traverso (AMG & Associates, Inc.) , Christopher Tumasone (AMG & Associates, Inc.) SUGGESTION: This is in regarding the installation of below grade cast iron pipes for sewer and stone drain utility lines. We propose to use No -Hub pipe with heavy duty with heavy duty, 4- band coupling which provides a stronger connection. That type of connection is commonly used in both below grade and above grade applications. Please advise Attachments: BY DATE COPIES TO AMG & Associates Inc. Page 1 of 1 Printed On: 05/11/2022 07:33 AM ABO INC. May 9, 2022 AMG & ASSOCIATES Attn: Chandra Sutton Project: Ladera Linda Community Center and Park 32201 Forrestal Dr. Rancho Palos Verdes, California 90275 LIC #: 1081727 - C36 DIR #: 1000833272 Office: (310) 299-6251 Cell: (818) 921-5152 Email: Info(&—abgla.com RFI 01 - Underground Cast Iron Pipes This is in regarding the installation of below grade cast iron pipes for sewer and storm drain utility lines. We propose to use No -Hub pipe with heavy duty with heavy duty, 4- band coupling which provides a stronger connection. That type of connection is commonly used in both below grade and above grade applications. Please advise. RESPONSE: KPFF RESPONSE: PROPOSED COUPLINGS ARE ACCPETABLE TO USE FOR SEWER AND STORM DRAIN CONNECTIONS. K.FINCH 05/17/2022 Per OAC discussion, we understand that this is a less expensive coupling, please confirm that there will be a cost saving. JF. 5i 17/22 6200 Canoga Ave #205, Woodland Hills, CA 91367 Project Architect Husky HD -2000 Submitral Heavy -Duty Couplings Engineer Contractor Date Husky HD -2000 Couplings The HUSKY HD -2000 coupling has been engineered to provide superior sealing while accommodating potential dimensional disparities in the mating of cast iron no–hub pipe and fittings. This has been accomplished through the use of a thicker, specially–designed corrugated shield of sufficient width to accommodate additional surface–bearing sealing clamps, torqued to 80in-lbs. These additional clamps result in a more uniformly rigid joint, with the load supported at both the outer edge of the coupling and the centerline of the joint. These clamps also yield increased surface–bearing contact, thereby inhibiting joint movement at higher internal pressures. uP[ Material Specifications Clamps: Type 304 AISI stainless steel. 4 clamps on sizes 1-1/2"-4', 6 clamps on sizes 5"-10" Screws: Type 305 AISI stainless steel 5/16" hex head Shield: Type 304 AISI stainless steel corrugated. Shield thickness 0.010" Gasket: Genuine neoprene as the primary elastomer, conforming to ASTM C564. Oil immersion rest: 80% maximum volume change after immersion in ASTM oil No. 3 for 70 hours at 212'F Suggested Specification No–Hub couplings shall be of the heavy-duty variety, with shields and bands made of Series 300 stainless steel, and gaskets made of genuine neoprene as the sole elastomer. 1-1/2" through 4" couplings shall have a minimum of four clamps, and 5" through 10" couplings shall have a minimum of 6 clamps. Couplings shall be installed in conformance with the manufacturer's installation instructions and local code requirements. Meets ASTM C 1540, ASTM C564, FM 1680 Class 1, CSA B 602. IAMPO File No. 6726 Anaco 0 1001 EI Camino Avenue 0 Corona, CA a 92879 951/372-2732 a Fax: 951 /738-1 183 4 www.anoco–husky.com anaco® Standing; the test oltime HUSKY HD -2000 Heavy -Duty Coupling 0 Meets ASTM C 1540, ASTM C 564, FM 1680 Class 1, CSA B 602 • IAPMO File No. 6726 • Made in USA Gasket Test Tensile Strength Elongation 1500psi min. 250 min. D412 D412 60 Durometer (Shore A) 70 +/— 5 @ 760 +/— 5° F D2240 Accelerated Aging 15% maximum tensile and 20% D573 maximum elongation deterioration, 10 points maximum increase in hardness, all determinations after oven aging for 96hrs at 158°F. Compression Set 25% maximum after 22 hrs at 158°F D395 Method B Oil Immersion 80% maximum volume change after D471 immersion in IRM 903 for 70hrs at 2127 Ozone Cracking No visible cracking at 2x Dl 149 magnification of the gasket after 100hrs exposure in 1.5ppm ozone concentration at 100°F. Testing and inspection to be on gasket which is loop mounted to give approximately 25% elongation of outer surface. Tear Resistance 150lbs. minimum per inch D624 of thickness Water Obsorption 20% maximum by weight after 7 D471 days at 158°F W Bracing Horizontal pipe and fittings 5" and larger must be suitably braced to prevent horizontal movement. This must be done at every branch opening or change of direction by the use of braces, blocks, rodding, or other suitable method, to prevent movement or joint separation (Ch IV, Handbook, Cast Iron Soil Pipe Institute.) *Ff Marketed by AB&I Foundry 7825 San Leandro Street 0 Oakland, CA 94621 800/GOT.IRON (468-4766) Fax: 510/632-3467 9 www.abifoundry.com ■171HEIRA R U B B E R C 0 M P A N � Mission Rubber Company LLC 1660 Leeson Lane Corona, CA 92879 _ (800) 854-9991 - Fax (800) 637-4601 i,- missionnibber.com r l_'i ad 16 For installations Requiring a Shielded Transition Coupling that Joins Similar and Dissimilar Pipe Sizes and Pipe Materials V. SIZES 3A" THROUGH 4" - 2 BANDS '- SIZES 5"THROUGH 12" - 4 BANDS CLAMP DETAILS Band -Seal® Coupling - Submittal C Series Performmnc•e Couplings fa- Similar and Dissimilar Pipe Sizes and Materials PROJECT ENGINEER CONTRACTOR SHIELD DETAILS SEALING GASKET CROSS SECTION DETAILS HOUSING 1.21 MAX .75 SADDLE .36 MATERIALS B.ed Serie 301 ASTM deaden pal Sc-reScIla�g S"ie 301 ASTM Mmlea+nal S_ Saddk Si. 301 orASTM MW- slat Snow Si. 305 ASTM Purl -steel ShieldSenn 301 ASTM Minim neel Gina, This guka is fabricated from a compound s.0 high-q.,Wy elasiomeric propenie 2.12 to meet physinl iwmg SHIELD DETAILS SEALING GASKET CROSS SECTION DETAILS HOUSING 1.21 MAX .75 SADDLE .36 SHIELD DIMENSIONS L W SEALING GASKET DIMENSIONS D7 D2 W .19 12.69 .81 MAX 1.90 HEX HEAD D1 D2 O •47 SCREW 12.69 O 2.35 O 2.12 0 16.00 O 235 �+ r--.50 .026±.003 IOW_ ! MISSION REFERENCE C SERIES SHIELD DIMENSIONS L W SEALING GASKET DIMENSIONS D7 D2 W C315 12.69 2.12 1.90 3.35 2.12 C 320 12.69 2.12 2.35 3.35 2.12 C 420 16.00 2.12 235 4.38 2.12 C 430 16.00 2.12 3.35 4.38 2.12 C 530 18.50 3.00 3.35 5.30 3.00 C 540 18.50 3.00 4.38 5.30 3.00 C 640 21.75 3.00 438 6.30 3.00 c 650 21.75 3.00 5.30 6.30 3.00 Used to Join - C Series couplings are used to join cast iron to cast iron, plastic or steel for C 315, C 320 & C 420; and cast iron to cast iron in remaining products. Mission's Band -Seal' Specialty Coupling is a shielded transition coupling designed to connect similar and dissimilar pipe sizes and materials. Coupling consists of two (2) or four (4) 301 series stainless steel worm drive clamps, a 300 series stainless steel shield, over a molded one-piece elastomeric sealing gasket. C Series couplings are available in sizes 1112" to 6": 3" to 4" sizes utilize two (2) clamps; 5" to 6" sizes utilize four (4) clamps. Leak -Proof Seal - Stainless steel clamps provide a positive seal when properly tightened to 60 in/lbs. of torque. Sealing "O" Rings are installed under each sealing clamp to prevent pipe slippage and create a more positive seal, ensuring a water -tight, leak -proof and root -proof seal. Corrosion Resistant - 300 series stainless steel components provide highly effective corrosion resistance in a variety of environments. .38 .19 D30 Joint Movement Restraint - The Band -Seal- Specialty Coupling provides for superior load bearing control between the coupling and pipe surface. The coupling's rugged construction provides excellent sealing properties, and the stainless steel shield offers excellent resistance to shear forces and helps with alignment, while maintaining flexibility. Internal Pipe Stop - For proper pipe positioning and noise/vibration reduction. Pre -Set Calibration - All Band -Seal' Specialty Couplings are designed to be installed with a pre-set torque wrench calibrated to 60 in/lbs. maximum to accommodate the 305 series stainless steel S/,s' hex head screw. Rev. 10/20 ASTM TEST GASKET PHYSICAL TESTS (ASTM C 564) C 56464 Tensile Strength 1500 PSI minimum D412 Elongation 250% minimum D412 Durometer (Shore A) 70 t 5 @ 76-F 3 SF D2240 15% maximum tensile and 20% maximum elongation Accelerated Aging deterioration. 10 points maximum increase In hardness. D573 All determinations after oven aging (or 96 hours at 158T. Compression Set 15% maximum after 22 hours at 158T D395 Oil Immersion 80% maximum volume change after Immersion In ASTM D471 oil 03 for 70 hours at 2127 No visible cracking at 2x magnification of the gasket after 100 hours exposure In 1 S PPHM ozone concentration at 1007. Ozone Cracking Testing and Inspection to be on gasket which Is loop -mounted to give approximately 20% elongation of outer surface. Tear tance Resis Die 150 lbs. minimum per inch of thickness D624 Water Absorption 20% maximum by weight after 7 days at 1587 D471 Joint Movement Restraint - The Band -Seal- Specialty Coupling provides for superior load bearing control between the coupling and pipe surface. The coupling's rugged construction provides excellent sealing properties, and the stainless steel shield offers excellent resistance to shear forces and helps with alignment, while maintaining flexibility. Internal Pipe Stop - For proper pipe positioning and noise/vibration reduction. Pre -Set Calibration - All Band -Seal' Specialty Couplings are designed to be installed with a pre-set torque wrench calibrated to 60 in/lbs. maximum to accommodate the 305 series stainless steel S/,s' hex head screw. Rev. 10/20