Appendix-JAppendix J Table 1 Design Criteria TABLE 1 STORM DRAIN DESIGN CRITERIA DESIGN CRITERIA LOS ANGELES COUNTY PUBLIC WORKS Section 4.2 of LACPW 2006 Hydrology Flood Protection Manual-Capital Flood Protection (50-year frequency design)applies to canyons within the County of LA that are subject to burning. Where velocity exceeds 20 fps the total horizontal angle of divergence or convergence Maximum Velocity between the walls of a manhole and it's centerrvmax)line shall not exceed 5°45' Extra thick walled pipe to increase cover over interior steel Minimum Diameter of 24-inch (standard conditions) main line conduit 42-inch (serving a non-standard debris basin) Minimum Slope (S min)0.1% 200ft (for S 30-inch) Minimum Distance 400 ft (for 30-inch >d>45-inch) Between Manholes 500 ft (for 45-inch and larger pipes) MH's to be located outside of intersection Manning's Roughness 0.013 for RCP Coefficient (n)0.012 for HDPE RCP -preferred Drainage Pipe Material HOPE -allowed rarely (to date only for "above ground"installations such as down a slope face where movement is anticipated) <45 0 and <300 where: Angle of Confluence 1.Qin of lateral exceeds 10%of mainline Q 2.V of lateral exceeds 20 fps 3.Size of lateral 2:60-inches Allowable Computer 1.WMS for hydrology analysesPrograms(used for this project study)2.WSPG for hydraulic analyses MH NO.1 where mainline is :>;33"(2-D 102) MH No.2 where mainline is ~36"(2-D 184) Manholes Standards MH No.4 where lateral is 2:half the diameter of the mainline except for mainlines are :>;36"(2-D 113) Minimum Cover over pipe 2ft Project is in DPA Zone 6 (per 1-H 1.2 map LACPW Sedimentation Manual)with a total Sediment Production of 5,434 C.Y.per Sediment Basin per Zone equation 3.3.3 Requires elevated Inlet per Table 4.1.1 of the LACPW Sedimentation Manual Second Edition dated March 2006 Page 1 of 1 -.8Harris &Associates