Point Vicente Fishing Access_ComplianceReport_20130509-115054Facility ID # 11 - Point Vicente Fishing AccessReporting: 77 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 05 - Drinking Fountains Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 05.01A - "Hi" Drinking Fountain Requirement Where there is only one drinking fountain area on a floor (e.g.., an area with a drinking fountain or separate drinking fountains), it is accessible to wheelchair users and not to persons who have difficulty bending or stooping (i.e., the required accessibility for persons who have difficulty bending or stooping on each floor has not been provided). 4.1.3(10 )(a); 4.15.1 211.1; 211.2 1115B.4 .6 item 1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 28 Pathway 05.08A - Wall- Mounted Protruding Objects Wall mounted drinking fountain with leading edges between 27" and 80” from the floor projects more than 4" into the circulation path. 4.4.1 204; 307.2; Advisory 307.2; Fig. 1133B.8 .6.1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 29 Pathway 05.11 - Water Flow - Round or Oval Bowl For a fountain with a round or oval bowl, the water flow is not within 3” of the fountain's front edge. 4.15.3 -1115B.4 .6 item 5 -4".PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 30 Pathway 05.13 - Operation The controls are not compliant.(Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 602.3; 309.4 1115B.4 .6 item 4 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 31 Pathway 05.07 - Clear Floor Space Drinking fountain does not have a 30” x 48” clear floor space that adjoins or overlaps an accessible route of travel and that allows a forward approach by wheelchair users. (A side approach is not acceptable.) 4.15.5(1 ); Figs. 27(c) and (d) 305.1 1115B.4 .6 item 2 -36" clear to edge of concrete walk. PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 32 Pathway 5Number of Key Notes for Group 05 - Drinking Fountains: Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation Page 1 of 16 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 11 - Point Vicente Fishing AccessReporting: 77 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.20 - Directions to Accessible Entrance Where not all entrances are accessible, directional signage has not been provided indicating the accessible route to an accessible entrance. 4.1.2(7) ; 4.1.3(8) (d) 216.6; Advisory 216.6; 703.5 1117B.5 .8.1.2 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 13 Decomposed Granite Pathway 03B.14 - Changes in Level (Curb Ramps, Ramps, or Elevators) Curb ramps, ramps, or elevators are not compliant. 4.7.1; 4.8.1 405; 406 --PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 14 Decomposed Granite Pathway 03B.01 - On- site Accessible Route of Travel There is no accessible route within the property line of the site linking an accessible building entrance with site arrival points serving the following, if provided: public transportation stops, accessible parking, passenger loading zones, and public sidewalks. 4.1.2(1) 202.2.1; Advisory 206.2.1 1114B.1 .2; 1127B.1 -No POT from PROW to restrooms. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 15 Decomposed Granite Pathway 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -3.2% to 4.2% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 16 Concrete Pathway Page 2 of 16 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 11 - Point Vicente Fishing AccessReporting: 77 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.21 - Hazardous Vehicular Areas - Detectable Warnings Where a walk crosses or adjoins the vehicular way and the walking surface is not separated by curbs, railings, or other elements between the pedestrian areas and vehicular areas, the boundary between the areas is not defined by a continuous detectable warning at least 36” wide complying with CBC 1121B.3.1 item 8(a). (i.e., the warning surface shall contrast visually with adjoining surfaces, either light on dark or dark on light, and shall differ from adjoining walking surfaces in resiliency or sound on cane contact. Color: yellow conforming to Federal Color No. 33538, Table IV/ Standard No. 595B. Where the color value contrast between the yellow warning and the main walking surface is less than 70 percent, a 1" wide black strip shall separate the yellow warning from the main walking surface.) 4.29.5 705.1 1133B.8 .5 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 17 Concrete Pathway 03B.13 - > 1/2" Changes in Level Curb ramps, ramps, or elevators are not used for changes in level greater than 1/2 inch. (Lifts may only be used in certain limited situations.) 4.5.2 303.4 1124B.2 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 21 Pathway 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.9% to 4.4% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 23 Pathway 03B.04 - Width Accessible route of travel is less than 48” wide (note: 48" wide requirement does not apply to doorways or gates). 4.3.3 403.5.1 1133B.7 .1 -36" to 40" at wall.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 24 Pathway 03B.13 - > 1/2" Changes in Level Curb ramps, ramps, or elevators are not used for changes in level greater than 1/2 inch. (Lifts may only be used in certain limited situations.) 4.5.2 303.4 1124B.2 -3" to 10" level change.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 25 Pathway Page 3 of 16 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 11 - Point Vicente Fishing AccessReporting: 77 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.17 - > 4” Abrupt Change in Level Site includes abrupt changes in level adjacent to pedestrian areas exceeding 4” vertical (exceptions: (1) between a walk or sidewalk and an adjacent street or driveway, or (2) where a 6” high warning curb or guardrail is provided to warn of a potential drop off). --1133B.8 .1 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 26 Pathway 03B.04 - Width Accessible route of travel is less than 48” wide (note: 48" wide requirement does not apply to doorways or gates). 4.3.3 403.5.1 1133B.7 .1 -36" to 40" at wall.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 27 Pathway 11Number of Key Notes for Group 03B - On-Site Path of Travel: Group 01 - Parking Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 01.09 - Stall Dimensions Accessible parking spaces, including van spaces, are not at least 9’ wide and 18’ long with a demarcated access aisle. (Two spaces may share a common aisle; parking space width is measured from the center line of the stripe on one side to the center line of the stripe on the other.) 4.6.3 502.2 1129B.3 items 1 & 2 17'-7" long.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 2 Parking 01.10A - Van Access Aisle - Dimensions Where the parking space is designated as "van accessible," the adjacent access aisle is not at least 8’ wide by 18’ long. (Aisle width is measured from the center line of the stripe on one side to the center line of the stripe on the other.) 4.1.2(5) (b) -1129B.3 item 2 17'-7" long by 8'-6" wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 3 Parking 01.11 - Car Access Aisle - Dimensions Car access aisle is not at least 5’ wide and 18’ long. (Aisle width is measured from the center line of the stripe on one side to the center line of the stripe on the other.) 4.1.2(5) (a) 502.3.1 1129B.3 item 1 17'-7" long by 4'-8" wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 4 Parking Page 4 of 16 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 11 - Point Vicente Fishing AccessReporting: 77 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 01 - Parking Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 01.13 - Level Surface The accessible parking spaces and access aisles are not level (slope is greater than 2%). 4.6.3 502.4; advisory 502.4 1129B.3 items 3 & 4 2.6% to 3.5% CS & 3.0% to 5.2% RS. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 5 Parking 01.15B - Parking Space Sign Accessible parking space has no reflectorized sign visible from the stall, showing an ISA in white on a blue background. 4.6.4 502.6 1129B.4 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 6 Parking 01.15C - Minimum Fine Sign Accessible parking space has no sign stating "Minimum Fine $250" below the ISA. --1129B.4 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 7 Parking 01.17 - Van Accessible Sign Van accessible space has no sign stating "Van Accessible" below the ISA. 4.6.4 502.6 1129B.4 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 8 Parking 01.19B - Tow- away Sign A California tow-away sign is not posted in a conspicuous place at each entrance to off–street parking lot, or immediately adjacent to and visible from each accessible stall. --1129B.4 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 9 Parking 01.23 - Other - Parking See Additional Comments ---1" level change at concrete curb. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 10 Parking 01.23 - Other - Parking See Additional Comments ---No detectable warning provided. PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 11 Parking 10Number of Key Notes for Group 01 - Parking: Page 5 of 16 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 11 - Point Vicente Fishing AccessReporting: 77 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 30 - Parks Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 30.06E - Outdoor Recreation Access Route (ORAR) Segment - Cross Slope Cross slope of the access route segment exceeds 3.33%. Exception: Cross slopes of 5% maximum are permitted to ensure proper drainage. ---1999 ADAAG- 16.3.7.1 2.65 to 11.1% slope.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 12 Decomposed Granite Pathway 30.05 - Accessible Route - Width Accessible route of travel is less than 48” wide (note: 48" wide requirement does not apply to doorways or gates). 4.3.3 403.5.1 1133B.7 .1 -30" to 3' due to shrubs.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 18 Pathway 30.08 - Maintenance of Accessible Trail - Title II Entity Accessible trail is not in operable working condition. (28 CFR 35.133) --1101B.3 28 CFR 35.133 Water erosion.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 19 Pathway 30.06E - Outdoor Recreation Access Route (ORAR) Segment - Cross Slope Cross slope of the access route segment exceeds 3.33%. Exception: Cross slopes of 5% maximum are permitted to ensure proper drainage. ---1999 ADAAG- 16.3.7.1 2.4% to 7.2% at various locations. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 20 Pathway 30.05 - Accessible Route - Width Accessible route of travel is less than 48” wide (note: 48" wide requirement does not apply to doorways or gates). 4.3.3 403.5.1 1133B.7 .1 -24" wide due to shrubs.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 22 Pathway 30.10E - Trail Surface The surface of the trail is not firm or stable.---1999 ADAAG- 16.2.1 PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 70 Trail Page 6 of 16 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 11 - Point Vicente Fishing AccessReporting: 77 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 30 - Parks Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 30.10A - Trail Segment - Running Slope Running slope of trail segment in the direction of travel does not comply with the following: a. 5% or less for any distance. b. From 5.1% to 8.33% for 200' maximum. c. From 8.34% to 10% for 30' maximum. d. From 10% to 12% for 10' maximum. ---1999 ADAAG- 16.2.7.2 .1; 16.2.7.2 .2; 16.2.7.2 .3; 16.2.7.2 .4 10.7% to 20.1% RS.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 71 Trail 30.10C - Trail Segment - Cross Slope Cross slope of the trail segment exceeds 1:20.---1999 ADAAG- 16.2.7.1 12.3% to 17.6% CS.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 72 Trail 30.68 - Other - Parks See Additional Comments ----Loose rocks on trail.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 73 Trail 30.48 - Trash & Recycling Receptacles - Landing The trash and/or recycling receptacle is not located on stable, firm ground. OR A clear space min.. of 30" x 48" has not been provided. OR Slope is greater than 2% in some or all directions. (3% allowed if necessary for drainage). 4.3.7 403.3 -1999 ADAAG- 16.8.2; 16.8.3; 16.8.4 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 74 Trail 30.10C - Trail Segment - Cross Slope Cross slope of the trail segment exceeds 1:20.---1999 ADAAG- 16.2.7.1 5.5% to 17.3% CS.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 75 Trail Page 7 of 16 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 11 - Point Vicente Fishing AccessReporting: 77 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 30 - Parks Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 30.10A - Trail Segment - Running Slope Running slope of trail segment in the direction of travel does not comply with the following: a. 5% or less for any distance. b. From 5.1% to 8.33% for 200' maximum. c. From 8.34% to 10% for 30' maximum. d. From 10% to 12% for 10' maximum. ---1999 ADAAG- 16.2.7.2 .1; 16.2.7.2 .2; 16.2.7.2 .3; 16.2.7.2 .4 6.8% to 28.2% RS.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 76 Trail 30.10B - Trail Resting Space Resting space does not comply with 1999 ADAAG Section 16.2.8 (Resting intervals shall be 60" min. in length, shall have a width at least as wide as the trail and have a slope of 5% or less in any direction. The installation of resting spaces is required as follows: Percent slope, maximum length, Rest interval: 0% to 5.0%, No restriction, No restriction; 5.1% to 8.33%, 200', Every 200'; 8.34% to 10%, 30', Every 30'; 10.1% to 12%, 10', Every 10'.) ---1999 ADAAG- 16.2.7.2 ; 16.2.8 PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 77 Trail 13Number of Key Notes for Group 30 - Parks: Group 03A - Public Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03A.07A - Cross Slope (PAR) Cross slope of the pedestrian access route exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 2005 PROWA G- R301.4. 1 3.7% to 6.3% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 1 Decomposed Granite Pathway 1Number of Key Notes for Group 03A - Public Path of Travel: Page 8 of 16 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 11 - Point Vicente Fishing AccessReporting: 77 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.04 - Accessible Path of Travel Toilet room is not located on an accessible route of travel. 4.22.1 206.2.4; Advisory 206.2.4 1115B.1 -No POT to restroom from PROW. PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 33 Women's Restroom 16.07 - Clear Door Opening When the door is open 90 degrees, clear opening width is less than 32” measured between the face of the door and the doorstop on the latch side. 4.13.5 404.2.3 1133B.1 .1.1.1; 1133B.2 .2 -29" wide.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 34 Women's Restroom 16.09A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6 404.2.4. 1; Table 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2; Fig. 11B-26 -46 1/2" on push side PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 35 Women's Restroom 16.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -12 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 36 Women's Restroom Page 9 of 16 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 11 - Point Vicente Fishing AccessReporting: 77 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.13B - Women's RR Geometric Symbol Signage - Circle Doorway leading to a women’s toilet room is not identified by a circle, 1/4" thick and 12” in diameter. OR Circle is provided, however it is accompanied by words in raised characters and Braille. (ADA and CBC Standards require a separate sign with raised characters and Braille mounted on the wall adjacent to the latch side of the door.) --1115B.6 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 37 Women's Restroom 16.15A - Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.30.1 216.2; 703.1; 703.2; 703.5 1117B.5 .1(1) -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 38 Women's Restroom 16.18A - ISA Accessible toilet room is not identified by an ISA. 4.1.3(16 )(b) 216.8 1117B.5 .1(3) -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 39 Women's Restroom 16.47A - WC Location from Sidewall The centerline of the WC is not 18” absolute from a wall or partition. 4.22.4 -1115B.4 .1(1) -19 1/2".PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 40 Women's Restroom 16.48 - WC Seat Height The top of the WC seat is not between 17” and 19” AFF. 4.16.3; Fig. 29(b) 604.4 1115B.4 .1(4); Fig. 11B-1A -16" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 41 Women's Restroom 16.49B - WC Flush Controls - Location Flush controls are not located on the wide side of the WC where the clear floor space is provided. 4.16.5 604.6; Advisory 604.6 1115B.4 .1(5); Fig. 11B-1A -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 42 Women's Restroom Page 10 of 16 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 11 - Point Vicente Fishing AccessReporting: 77 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.50_07CBC - TP Dispenser - Location Location of the toilet paper dispenser is not compliant. (Effective January 1, 2008, CBC Standards require toilet tissue dispensers located on the wall within 12" of the front edge of the toilet seat, mounted below the grab bar, centered at a min. height of 19" AFF, and 36" maximum to the dispenser's far edge from the rear wall; there is no requirement to retroactively alter existing toilet paper dispensers when installed in compliance with CBC Standards in effect at the time of original construction.) 4.16.6; Fig. 29(b) 604.7; Advisory 604.7; Fig. 604.7 1115B.8 .4; Fig. 11B-1A -15" from WC.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 43 Women's Restroom 16.55A - Side Grab Bar Height Side grab bar is not centered at 33" AFF. (ADA Standards require side grab bars to be centered from 33" to 36" AFF; CBC Standards require side grab bars to be centered at 33" AFF.) 4.17.6; Figs. 29 & 30 604.5; Advisory 604.5; 604.5.2; Fig. 604.5.2; 609.4 1115B.4 .1(3.1); Fig. 11B-1A -33 3/8" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 44 Women's Restroom 16.72 - Lavatory Apron Clearance Lavatory does not provide accessible apron clearance (i.e. at least 29” clearance from the floor to the bottom of the apron). 4.19.2; Fig. 31 606.3 1115B.4 .3(2); Fig 11B- 1D -27 1/2" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 45 Women's Restroom 16.78 - Pipe Insulation at Lavatory Drainpipes and hot water pipes are not insulated to protect against contact. 4.19.4 606.5 1115B.4 .3(4) -PV - Public/Visitor Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 46 Women's Restroom 16.79 - Smooth Surfaces at Lavatory The area below the lavatory is not free of sharp or abrasive surfaces. 4.19.4 606.5 1115B.4 .3(4) -PV - Public/Visitor Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 47 Women's Restroom Page 11 of 16 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 11 - Point Vicente Fishing AccessReporting: 77 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.55B - Back Grab Bar Height - Non- Tank-Type WC At non-tank-type WC, back grab bar is not centered at 33" AFF. (ADA Standards require back grab bars to be centered from 33" to 36" AFF; CBC Standards require back grab bars to be centered at 33" AFF.) 4.17.6; Figs. 29 & 30 604.5; Advisory 604.5; 609.4 1115B.4 .1(3.2); Fig. 11B-1A -33 3/8" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 48 Women's Restroom 16.04 - Accessible Path of Travel Toilet room is not located on an accessible route of travel. 4.22.1 206.2.4; Advisory 206.2.4 1115B.1 -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 49 Men's Restroom 16.07 - Clear Door Opening When the door is open 90 degrees, clear opening width is less than 32” measured between the face of the door and the doorstop on the latch side. 4.13.5 404.2.3 1133B.1 .1.1.1; 1133B.2 .2 -29" wide.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 50 Men's Restroom 16.08A - Door Swing The door swing intrudes into the clear floor space of one or more fixtures. 4.22.2 603.2.3; Advisory 603.2.3 1115B.3 .1 item 2; 1115B.3 .2 item 2; 1115B.5 -Encroaches lavatory clear floor space by 12". PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 51 Men's Restroom 16.09A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6 404.2.4. 1; Table 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2; Fig. 11B-26 -46" on push side.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 52 Men's Restroom Page 12 of 16 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 11 - Point Vicente Fishing AccessReporting: 77 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -15 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 53 Men's Restroom 16.13A - Men's RR Geometric Symbol Signage - Triangle Doorway leading to a men’s toilet room is not identified by an equilateral triangle 1/4" thick with edges 12” long. OR Equilateral triangle is provided, however it is accompanied by words in raised characters and Braille. (ADA and CBC Standards require a separate sign with raised characters and Braille mounted on the wall adjacent to the latch side of the door.) --1115B.6 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 54 Men's Restroom 16.15A - Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.30.1 216.2; 703.1; 703.2; 703.5 1117B.5 .1(1) -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 55 Men's Restroom 16.18A - ISA Accessible toilet room is not identified by an ISA. 4.1.3(16 )(b) 216.8 1117B.5 .1(3) -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 56 Men's Restroom 16.47A - WC Location from Sidewall The centerline of the WC is not 18” absolute from a wall or partition. 4.22.4 -1115B.4 .1(1) -19 3/8".PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 57 Men's Restroom 16.48 - WC Seat Height The top of the WC seat is not between 17” and 19” AFF. 4.16.3; Fig. 29(b) 604.4 1115B.4 .1(4); Fig. 11B-1A -16" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 58 Men's Restroom Page 13 of 16 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 11 - Point Vicente Fishing AccessReporting: 77 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.50_07CBC - TP Dispenser - Location Location of the toilet paper dispenser is not compliant. (Effective January 1, 2008, CBC Standards require toilet tissue dispensers located on the wall within 12" of the front edge of the toilet seat, mounted below the grab bar, centered at a min. height of 19" AFF, and 36" maximum to the dispenser's far edge from the rear wall; there is no requirement to retroactively alter existing toilet paper dispensers when installed in compliance with CBC Standards in effect at the time of original construction.) 4.16.6; Fig. 29(b) 604.7; Advisory 604.7; Fig. 604.7 1115B.8 .4; Fig. 11B-1A -16" in front of WC.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 59 Men's Restroom 16.55B - Back Grab Bar Height - Non- Tank-Type WC At non-tank-type WC, back grab bar is not centered at 33" AFF. (ADA Standards require back grab bars to be centered from 33" to 36" AFF; CBC Standards require back grab bars to be centered at 33" AFF.) 4.17.6; Figs. 29 & 30 604.5; Advisory 604.5; 609.4 1115B.4 .1(3.2); Fig. 11B-1A -33 1/4" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 60 Men's Restroom 16.65B - Wall- Hung Urinal - Rim Height Height of wall-hung urinal's rim exceeds 17” AFF. 4.18.2 605.2; Fig. 605.2(a) 1115B.4 .2(1) -26" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 61 Men's Restroom 16.65D - Urinal Flush Controls - Height Height of urinal flush controls exceeds 44" AFF.4.18.4 605.4; 604.6; Advisory 604.6 1115B.4 .2(2) -51" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 62 Men's Restroom 16.72 - Lavatory Apron Clearance Lavatory does not provide accessible apron clearance (i.e. at least 29” clearance from the floor to the bottom of the apron). 4.19.2; Fig. 31 606.3 1115B.4 .3(2); Fig 11B- 1D -27" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 63 Men's Restroom Page 14 of 16 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 11 - Point Vicente Fishing AccessReporting: 77 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.73 - Lavatory Knee Clearance Lavatory does not provide accessible knee clearance (i.e. at least 27” clearance from the floor to the underside of the lavatory, extending 8” min.. measured from the front edge underneath the lavatory back towards the wall). 4.19.2; Fig. 31 306.3; Fig. 306.3 1115B.4 .3(2); Fig 11B- 1D -26 1/2" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 64 Men's Restroom 16.76 - Lavatory - Clearance near Sidewall The centerline of the lavatory is not 18” min.. from the nearest sidewall or partition. --1115B.4 .3(2); Fig 11B- 1D -13 3/4".PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 65 Men's Restroom 16.77 - Lavatory Location The lavatory's clear floor space does not adjoin or overlap an accessible path of travel. --1115B.4 .3(3) -Door encroaches.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 66 Men's Restroom 16.78 - Pipe Insulation at Lavatory Drainpipes and hot water pipes are not insulated to protect against contact. 4.19.4 606.5 1115B.4 .3(4) -PV - Public/Visitor Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 67 Men's Restroom 16.79 - Smooth Surfaces at Lavatory The area below the lavatory is not free of sharp or abrasive surfaces. 4.19.4 606.5 1115B.4 .3(4) -PV - Public/Visitor Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 68 Men's Restroom 16.82B - Mirror Height - Max. 35" AFF Standard Mirror not above accessible lavatory or countertop is mounted so the bottom edge of the reflective surface is not 35” max.. AFF. (Effective August 1, 2009, where mirrors are provided at locations other than lavatories or countertops, amended CBC Standards require at least one to be accessible.) -213.3.5; 606.3; Advisory 603.3 1115B.8 .1 -40 1/4" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 69 Men's Restroom 37Number of Key Notes for Group 16 - Toilet Facilities: Page 15 of 16 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 11 - Point Vicente Fishing AccessReporting: 77 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment 77Number of Key Notes for Facility 11 - Point Vicente Fishing Access: 77Total Number of Key Notes for All Groups: Page 16 of 16 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA