Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Martingale Trailhead Park_PhotoFacility_20130509-115330
City of Rancho Palos Verdes Rancho Palos Verdes ADA Assessment Facility Report with Photos Facility ID: # 14 - Martingale Trailhead ParkReporting: 8 of 4367 Rcds Author: Vaish, B 05.03 - Accessible Route - The accessible drinking fountain is not located on an accessible route. Existing Condition: Drinking Fountain on Planting Area, provide safety rail. 004A - Asphalt Paving - Remove non-compliant pavement and replace with new asphalt paving (area as shown on the drawings). The walkway slope shall not exceed 5% along the POT and cross slope shall not exceed 2%. Additional Comments: Corrective Action Photo # 1 1991 ADAAG 4.1.3(10)(b) 2004 ADAAG 206.2.4 2007 CBC 1115B.4.6 item 1 Other - Priority: Total Cost $1,253 1 Field Condition Status Not Complete As of 05/09/2013 Keynote Costs and Funding Plan Nbr:DBB Use:PV Severity:C DOJ Location Type:4 Level of Difficulty Low to Moderate Location: Near the Road Planned Completion 6/30/2052 Classification Implementation Funding Received $0 Status Update (check one) Completed □ In Progress □ Not Complete □ As of _____________ By ____________ Reported By Qty ...Of:64 SF 05.04 - Depth - Drinking fountain is not 18” min.. to 19” max.. in depth. Existing Condition: 0" 273 - Replace Freestanding High/Low Drinking Fountain - Remove existing drinking fountain and replace with an accessible park-type hi-low drinking fountain. Reconnect plumbing and drain lines to existing piping. Provide a sand trap in the drain line. Additional Comments: Corrective Action Photo # 1 1991 ADAAG 4.15.5(1); Figs. 27(a) and (b) 2004 ADAAG - 2007 CBC 1115B.4.6 item 2 Other - Priority: Total Cost $7,200 2 Field Condition Status Not Complete As of 05/09/2013 Keynote Costs and Funding Plan Nbr:DBB Use:PV Severity:C DOJ Location Type:4 Level of Difficulty High Location: Near the Road Planned Completion 6/30/2052 Classification Implementation Funding Received $0 Status Update (check one) Completed □ In Progress □ Not Complete □ As of _____________ By ____________ Reported By Qty ...Of:1 EA Page 1 of 5 Printed 2013-05-09App: ©2010 BOA Architecture 877-225-4ADA City of Rancho Palos Verdes Rancho Palos Verdes ADA Assessment Facility Report with Photos Facility ID: # 14 - Martingale Trailhead ParkReporting: 8 of 4367 Rcds Author: Vaish, B 05.07 - Clear Floor Space - Drinking fountain does not have a 30” x 48” clear floor space that adjoins or overlaps an accessible route of travel and that allows a forward approach by wheelchair users. (A side approach is not acceptable.) Existing Condition: No Path of travel. 289 - Drinking Fountain - Miscellaneous - See Additional Comments Additional Comments: See keynote 1 for corrective action. Corrective Action Photo # 3 1991 ADAAG 4.15.5(1); Figs. 27(c) and (d) 2004 ADAAG 305.1 2007 CBC 1115B.4.6 item 2 Other - Priority: Total Cost $0 3 Field Condition Status Not Complete As of 05/09/2013 Keynote Costs and Funding Plan Nbr:DBB Use:PV Severity:C DOJ Location Type:4 Level of Difficulty Low to Moderate Location: Near the Road Planned Completion 6/30/2052 Classification Implementation Funding Received $0 Status Update (check one) Completed □ In Progress □ Not Complete □ As of _____________ By ____________ Reported By Qty ...Of:1 EA 05.01A - "Hi" Drinking Fountain Requirement - Where there is only one drinking fountain area on a floor (e.g.., an area with a drinking fountain or separate drinking fountains), it is accessible to wheelchair users and not to persons who have difficulty bending or stooping (i.e., the required accessibility for persons who have difficulty bending or stooping on each floor has not been provided). Existing Condition: 289 - Drinking Fountain - Miscellaneous - See Additional Comments Additional Comments: See keynote 2 for corrective action. Corrective Action Photo # 1 1991 ADAAG 4.1.3(10)(a); 4.15.1 2004 ADAAG 211.1; 211.2 2007 CBC 1115B.4.6 item 1 Other - Priority: Total Cost $0 4 Field Condition Status Not Complete As of 05/09/2013 Keynote Costs and Funding Plan Nbr:DBB Use:PV Severity:B DOJ Location Type:4 Level of Difficulty High Location: Near the Road Planned Completion 6/30/2017 Classification Implementation Funding Received $0 Status Update (check one) Completed □ In Progress □ Not Complete □ As of _____________ By ____________ Reported By Qty ...Of:1 EA Page 2 of 5 Printed 2013-05-09App: ©2010 BOA Architecture 877-225-4ADA City of Rancho Palos Verdes Rancho Palos Verdes ADA Assessment Facility Report with Photos Facility ID: # 14 - Martingale Trailhead ParkReporting: 8 of 4367 Rcds Author: Vaish, B 05.09A - Spout Height for Wheelchair Users - The spout outlet is higher than 36” from the floor. Existing Condition: 47" high. 289 - Drinking Fountain - Miscellaneous - See Additional Comments Additional Comments: See keynote 2 for corrective action. Corrective Action Photo # 5 1991 ADAAG 4.15.2 2004 ADAAG 602.4; 602.6; Advisory 602.6 2007 CBC 1115B.4.6 item 4 Other - Priority: Total Cost $0 5 Field Condition Status Not Complete As of 05/09/2013 Keynote Costs and Funding Plan Nbr:DBB Use:PV Severity:B DOJ Location Type:4 Level of Difficulty High Location: Near the Road Planned Completion 6/30/2017 Classification Implementation Funding Received $0 Status Update (check one) Completed □ In Progress □ Not Complete □ As of _____________ By ____________ Reported By Qty ...Of:1 EA 05.10A - Bubbler Location - The bubbler outlet is not within 6" of the front edge of the unit. Existing Condition: 12" From front edge. 289 - Drinking Fountain - Miscellaneous - See Additional Comments Additional Comments: See keynote 2 for corrective action. Corrective Action Photo # 5 1991 ADAAG 4.15.3 2004 ADAAG - 2007 CBC 1115B.4.6 item 4 Other - Priority: Total Cost $0 6 Field Condition Status Not Complete As of 05/09/2013 Keynote Costs and Funding Plan Nbr:DBB Use:PV Severity:C DOJ Location Type:4 Level of Difficulty High Location: Near the Road Planned Completion 6/30/2052 Classification Implementation Funding Received $0 Status Update (check one) Completed □ In Progress □ Not Complete □ As of _____________ By ____________ Reported By Qty ...Of:1 EA Page 3 of 5 Printed 2013-05-09App: ©2010 BOA Architecture 877-225-4ADA City of Rancho Palos Verdes Rancho Palos Verdes ADA Assessment Facility Report with Photos Facility ID: # 14 - Martingale Trailhead ParkReporting: 8 of 4367 Rcds Author: Vaish, B 05.13 - Operation - The controls are not compliant.(Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) Existing Condition: Twist type faucet control. 289 - Drinking Fountain - Miscellaneous - See Additional Comments Additional Comments: See keynote 2 for corrective action. Corrective Action Photo # 5 1991 ADAAG 4.27.4 2004 ADAAG 602.3; 309.4 2007 CBC 1115B.4.6 item 4 Other - Priority: Total Cost $0 7 Field Condition Status Not Complete As of 05/09/2013 Keynote Costs and Funding Plan Nbr:DBB Use:PV Severity:B DOJ Location Type:4 Level of Difficulty High Location: Near the Road Planned Completion 6/30/2017 Classification Implementation Funding Received $0 Status Update (check one) Completed □ In Progress □ Not Complete □ As of _____________ By ____________ Reported By Qty ...Of:1 EA Page 4 of 5 Printed 2013-05-09App: ©2010 BOA Architecture 877-225-4ADA City of Rancho Palos Verdes Rancho Palos Verdes ADA Assessment Facility Report with Photos Facility ID: # 14 - Martingale Trailhead ParkReporting: 8 of 4367 Rcds Author: Vaish, B 30.10A - Trail Segment - Running Slope - Running slope of trail segment in the direction of travel does not comply with the following: a. 5% or less for any distance. b. From 5.1% to 8.33% for 200' maximum. c. From 8.34% to 10% for 30' maximum. d. From 10% to 12% for 10' maximum. Existing Condition: Approximate. 200 Ft. long trail on City property & variable slope, 34.2% RS, unstable & loose surface. 429 - Signs - Miscellaneous - See Additional Comments Additional Comments: Provide Sign to include existing trail condition. Corrective Action Photo # 8 1991 ADAAG - 2004 ADAAG - 2007 CBC - Other 1999 ADAAG-16.2.7.2.1; 16.2.7.2.2; 16.2.7.2.3; 16.2.7.2.4 Priority: Total Cost $600 8 Field Condition Status Not Complete As of 05/09/2013 Keynote Costs and Funding Plan Nbr:DBB Use:PV Severity:A DOJ Location Type:1 Level of Difficulty High Location: Trail Planned Completion 6/30/2017 Classification Implementation Funding Received $0 Status Update (check one) Completed □ In Progress □ Not Complete □ As of _____________ By ____________ Reported By Qty ...Of:1 EA Page 5 of 5 Printed 2013-05-09App: ©2010 BOA Architecture 877-225-4ADA