Loading...
Marilyn Ryan Sunset Point Park_ComplianceReport_20130509-115019Facility ID # 10 - Marilyn Ryan Sunset Point ParkReporting: 56 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 04 - Curb Ramps Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 04.01A - Curb Ramp Location Where accessible route crosses a curb, a curb ramp has not been provided. 4.7.1 406.1; 406.5 1127B.5 item 1 2005 PROWA G-R207 No Path of Travel from DG to asphalt. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 2 DG Pathway 04.05 - Width The width of the curb ramp, not including the flared sides, is less than 48”. 4.7.3 406.1; 405.5 1127B.5 item 2 2005 PROWA G- R303.3. 1 45" wide. Walkway to DG at 2.6% CS. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 6 Curb Ramp 04.02 - Slope Slope of the curb ramp exceeds 8.33% (or the least possible compliant slope). 4.7.2; 4.8.2 405.2; Advisory 405.2 1127B.5 item 3 2005 PROWA G- R303.2. 1.1; R303.2. 2.1 9.3% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 12 Parking 04.10 - Detectable Warning Requirement Regardless of slope, the curb ramp does not have a detectable warning. 4.7.7; 4.29.2 705.1; Fig. 705.1 1127B.5 item 7 2005 PROWA G- R303.3. 2 PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 13 Parking 4Number of Key Notes for Group 04 - Curb Ramps: Group 05 - Drinking Fountains Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 05.13 - Operation The controls are not compliant.(Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 602.3; 309.4 1115B.4 .6 item 4 -Greater than 5 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 23 Drinking Fountain Page 1 of 11 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 10 - Marilyn Ryan Sunset Point ParkReporting: 56 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 05 - Drinking Fountains Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 05.01A - "Hi" Drinking Fountain Requirement Where there is only one drinking fountain area on a floor (e.g.., an area with a drinking fountain or separate drinking fountains), it is accessible to wheelchair users and not to persons who have difficulty bending or stooping (i.e., the required accessibility for persons who have difficulty bending or stooping on each floor has not been provided). 4.1.3(10 )(a); 4.15.1 211.1; 211.2 1115B.4 .6 item 1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 24 Drinking Fountain 05.03 - Accessible Route The accessible drinking fountain is not located on an accessible route. 4.1.3(10 )(b) 206.2.4 1115B.4 .6 item 1 -Grass on approach.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 25 Drinking Fountain 3Number of Key Notes for Group 05 - Drinking Fountains: Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.6% to 3.1% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 14 Walkway 03B.10 - Running Slope Slope of the accessible route of travel exceeds 1:20. 4.3.7 403.3 1133B.7 .3 -5.1% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 15 Walkway 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.3% to 3.2% CS at various locations. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 16 Walkway Page 2 of 11 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 10 - Marilyn Ryan Sunset Point ParkReporting: 56 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.10 - Running Slope Slope of the accessible route of travel exceeds 1:20. 4.3.7 403.3 1133B.7 .3 -5.3% to 7.9% RS at various locations. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 17 Walkway 03B.22 - Other - On-Site Accessible Path of Travel See Additional Comments ----2.2% to 4.7% slope.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 18 Walkway 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.7% to 3.3% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 49 Asphalt Path 03B.10 - Running Slope Slope of the accessible route of travel exceeds 1:20. 4.3.7 403.3 1133B.7 .3 -5.2% to 5.9% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 50 Asphalt Path 03B.22 - Other - On-Site Accessible Path of Travel See Additional Comments ----Dog waste bag not adjacent to POT. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 51 Asphalt Path 03B.15 - Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Uneven surface.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 52 Asphalt Path 03B.22 - Other - On-Site Accessible Path of Travel See Additional Comments ----PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 54 Picnic Table Page 3 of 11 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 10 - Marilyn Ryan Sunset Point ParkReporting: 56 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.10 - Running Slope Slope of the accessible route of travel exceeds 1:20. 4.3.7 403.3 1133B.7 .3 -2.8% to 3.7%PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 55 Asphalt Path 03B.11 - Ramps This portion of an accessible route with a slope greater than 5% does not comply with the requirements for compliant ramps. 4.8.1 405 1133B.5 -5.3% to 5.6%PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 56 Asphalt Path 12Number of Key Notes for Group 03B - On-Site Path of Travel: Group 01 - Parking Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 01.13 - Level Surface The accessible parking spaces and access aisles are not level (slope is greater than 2%). 4.6.3 502.4; advisory 502.4 1129B.3 items 3 & 4 2.8% CS & 2.8% to 4.0% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 8 Parking 01.15C - Minimum Fine Sign Accessible parking space has no sign stating "Minimum Fine $250" below the ISA. --1129B.4 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 9 Parking 01.19A - Lettering The words “NO PARKING” is not provided in each access aisle, painted in white, 12” high letters. --1129B.3 items 1 & 2 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 10 Parking 01.19B - Tow- away Sign A California tow-away sign is not posted in a conspicuous place at each entrance to off–street parking lot, or immediately adjacent to and visible from each accessible stall. --1129B.4 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 11 Parking Page 4 of 11 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 10 - Marilyn Ryan Sunset Point ParkReporting: 56 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 01 - Parking Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 01.17 - Van Accessible Sign Van accessible space has no sign stating "Van Accessible" below the ISA. 4.6.4 502.6 1129B.4 Sign is not provided at accessible parking space. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 53 Parking 5Number of Key Notes for Group 01 - Parking: Group 30 - Parks Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 30.07E - Outdoor Recreation Access Routes (ORAR) - Passing Space Where the width of the access route is less than 60", passing spaces measuring 60" x 60" are not provided at intervals of 200' maximum. ---1999 ADAAG- 16.3.6 47" wide DG path, provide 2 60" x60" passing spaces. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 4 DG Pathway 30.68 - Other - Parks See Additional Comments ----Provide sign to clarify pedestrian path vs. bike path. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 5 DG Pathway 30.34B - Picnic Table - Knee Space Width Picnic table does not provide at least 30" wide accessible knee clearance. 4.32.3 305; 306 1122B.3 1999 ADAAG- 16.5.4 27" clear width space.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 19 Picnic Table 30.32 - 36" Aisle Width Standard Around the picnic table, there is less than 36" clear space measured from the seat. ---1999 ADAAG- 16.5.5 20 1/2" to 38 1/2".PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 20 Picnic Table 30.28 - Picnic Site - Surface Slope The accessible picnic site is located on a surface area with slope greater than 2% in some or all directions.(1999 ADAAG: 3% slope is allowed when necessary for drainage). 4.3.7 403.3 -1999 ADAAG- 16.5.7 3.0% to 3.9% slope.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 21 Picnic Table Page 5 of 11 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 10 - Marilyn Ryan Sunset Point ParkReporting: 56 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 30 - Parks Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 30.25 - Number - Accessible Picnic Tables Where fixed picnic tables are provided in a picnic area, the required number of fixed picnic tables is not provided. (1999 ADAAG: Where two or more fixed picnic tables are provided in a picnic area, at least 50%, but never less than two, shall comply with 16.5.4 through 16.5.6. In addition, at least 40%, but never less than two, of the accessible picnic tables shall be connected to an outdoor recreation access route complying with 16.3.) ---1999 ADAAG- 16.5.1.2 4 picnic tables, 1 accessible.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 22 Picnic Table 30.21 - Fixed Bench Size Accessible bench does not have seats that are 20" to 24" in depth and 42" min. in length. OR The back support does not extend from a point 2" maximum above the bench to 18" min. above the bench. -903.3 903.4 Fig. 903.4 --16" deep seat, 17" back support. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 26 Bench 30.17 - Fixed Bench - Surface Slope Clear space has a slope greater than 2% in some or all directions.(1999 ADAAG: 3% slope is allowed when necessary for drainage). 4.3.7 403.3 -1999 ADAAG- 16.12.7 2.15 to 4.0% slope.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 27 Bench 30.16 - Fixed Bench / Wheelchair Seating Space - Shoulder Alignment A clear space at least 30" x 48" in size has not been provided at one end of the fixed bench so that a wheelchair user may be seated shoulder- to-shoulder with an individual seated on the bench. ---1999 ADAAG- 16.12.4 None provided.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 28 Bench 30.13 - Number and Dispersal - Accessible Fixed Benches Less than 50% of the fixed benches being provided in an area are accessible. OR They are not dispersed among the types provided. ---1999 ADAAG- 16.12.2. 2; 16.12.2 5 benches, 0 accessible.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 29 Bench Page 6 of 11 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 10 - Marilyn Ryan Sunset Point ParkReporting: 56 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 30 - Parks Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10Number of Key Notes for Group 30 - Parks: Group 03A - Public Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03A.07A - Cross Slope (PAR) Cross slope of the pedestrian access route exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 2005 PROWA G- R301.4. 1 2.2% to 5.0% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 1 DG Pathway 03A.03 - Surface (PAR) Accessible route surfaces are not stable, firm, and slip-resistant. 4.5.1 302.1; Advisory 302.1; 403.2 1124B.1 2005 PROWA G- R301.5 Uneven surface at decomposed granite path due to grass on path. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 3 DG Pathway 03A.09 - > 1/4" Changes in Level Where walkway levels change abruptly, the vertical difference between them exceed 1/4 inch. OR Changes in level between 1/4 inch and 1/2 inch are beveled with a slope greater than 1:2. 4.5.2 303.2; 303.3 1124B.2 2005 PROWA G- R301.5. 2 2" level change from concrete to decomposed granite. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 7 Curb Ramp 3Number of Key Notes for Group 03A - Public Path of Travel: Group 08 - Stairs Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 08.02B - Riser Height The risers are not uniform. OR The risers are not between 4” and 7” in height. 4.9.2 504.2 1009.3; 1133B.4 .5.3 -Height varies from 4" to 7", at 3 locations. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 30 Stair @ Lawn Page 7 of 11 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 10 - Marilyn Ryan Sunset Point ParkReporting: 56 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 08 - Stairs Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 08.05A - Exterior Stairs - Color Strip Contrasting color strips have not been provided. --1133B.4 .4 -None provided at 3 locations.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 31 Stair @ Lawn 08.07A - Continuous Handrails Continuous handrails are not provided along both sides. 4.9.4 504.6; 505.2 1133B.4 .1.1 -None provided.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 32 Stair @ Lawn 08.18 - Other - Stairs See Additional Comments ----No POT provided to connect stairs. PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 33 Stair @ Lawn 08.07A - Continuous Handrails Continuous handrails are not provided along both sides. 4.9.4 504.6; 505.2 1133B.4 .1.1 -Handrail not provided on both sides. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 34 East Stair 08.05A - Exterior Stairs - Color Strip Contrasting color strips have not been provided. --1133B.4 .4 -PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 35 East Stair 08.02B - Riser Height The risers are not uniform. OR The risers are not between 4” and 7” in height. 4.9.2 504.2 1009.3; 1133B.4 .5.3 -5 1/2" to 6" high risers.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 36 East Stair Page 8 of 11 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 10 - Marilyn Ryan Sunset Point ParkReporting: 56 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 08 - Stairs Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 08.09B - Handrail Extensions - Bottom Landing At ends of handrails, less than 12” plus the tread width extends beyond the bottom nosing. (Top and bottom handrail extensions are important safety features for persons with balance problems and must extend in the direction of the stair run to permit the intended use.) (Per ADA/CBC Standards, in existing buildings and facilities, full extension of handrails at stairs shall not be required in alterations where such extensions would be hazardous or impossible due to plan configuration.) 4.9.4(2) 505.10; 505.10. 3; Fig. 505.10. 3 1133B.4 .2.2 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 37 East Stair 08.03A - Tread Depth The treads are not uniform. OR The treads are less than 11” deep measured from riser to riser. 4.9.2 504.2 1009.3; 1133B.4 .5.3 -Tread depth varies from 14" to 15 1/2". PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 38 East Stair 08.03D - Level Landing Landing is not level (slope is greater than 2% in some or all directions). --1009.5. 1 -4.4% RS at top landing.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 39 East Stair 08.03C - Tread Slope The treads have a slope steeper than 2%.-504.4 [Excepti on] 1009.5. 1 -4.4% to 5.7%.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 40 East Stair 08.09E - Handrails - Height above Stair Nosings The tops of handrails are not between 34” and 38” above the stair nosings. 4.9.4(5) 505.4; Advisory 505.4; Fig. 505.4 1133B.4 .2.1 -33" high.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 41 East Stair 08.03D - Level Landing Landing is not level (slope is greater than 2% in some or all directions). --1009.5. 1 -4.4% RS at intermediate landing. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 42 East Stair Page 9 of 11 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 10 - Marilyn Ryan Sunset Point ParkReporting: 56 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 08 - Stairs Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 08.07A - Continuous Handrails Continuous handrails are not provided along both sides. 4.9.4 504.6; 505.2 1133B.4 .1.1 -Handrail only provided on one side. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 43 Central Stair 08.05A - Exterior Stairs - Color Strip Contrasting color strips have not been provided. --1133B.4 .4 -PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 44 Central Stair 08.03D - Level Landing Landing is not level (slope is greater than 2% in some or all directions). --1009.5. 1 -7.1% RS at bottom landing.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 45 Central Stair 08.02B - Riser Height The risers are not uniform. OR The risers are not between 4” and 7” in height. 4.9.2 504.2 1009.3; 1133B.4 .5.3 -5 1/2" to 6" high risers.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 46 Central Stair 08.09B - Handrail Extensions - Bottom Landing At ends of handrails, less than 12” plus the tread width extends beyond the bottom nosing. (Top and bottom handrail extensions are important safety features for persons with balance problems and must extend in the direction of the stair run to permit the intended use.) (Per ADA/CBC Standards, in existing buildings and facilities, full extension of handrails at stairs shall not be required in alterations where such extensions would be hazardous or impossible due to plan configuration.) 4.9.4(2) 505.10; 505.10. 3; Fig. 505.10. 3 1133B.4 .2.2 -12".PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 47 Central Stair 08.03C - Tread Slope The treads have a slope steeper than 2%.-504.4 [Excepti on] 1009.5. 1 -4.9%.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 48 Central Stair Page 10 of 11 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 10 - Marilyn Ryan Sunset Point ParkReporting: 56 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 08 - Stairs Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 19Number of Key Notes for Group 08 - Stairs: 56Number of Key Notes for Facility 10 - Marilyn Ryan Sunset Point Park: 56Total Number of Key Notes for All Groups: Page 11 of 11 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA