Loading...
LPVP-PVIC_ComplianceReport_20130509-114934Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 20 - Alarms Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 20.15 - Alarm Initiating Devices - Operation Operating hardware of the pull station is not accessible (i.e.: it requires tight grasping, pinching, or twisting of the wrist, or requires a force exceeding 5 lbs.) 4.27.4 309.4 907.3.2, 1117B.6 (4) -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 124 Lobby 20.04 - Common Use Areas - Visual Alarms Visual alarms are not provided in common use area(s) of the building such as meeting and conference rooms, open office space, classrooms, cafeterias, filing and photocopy rooms, employee break rooms, dressing, examination, and treatment rooms, and similar spaces that are not used solely as employee work areas. 4.28.1 215.2; 702.1 907.9.1. 1 -EW - Employee Work Area B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 132 Studio 20.04 - Common Use Areas - Visual Alarms Visual alarms are not provided in common use area(s) of the building such as meeting and conference rooms, open office space, classrooms, cafeterias, filing and photocopy rooms, employee break rooms, dressing, examination, and treatment rooms, and similar spaces that are not used solely as employee work areas. 4.28.1 215.2; 702.1 907.9.1. 1 -EW - Employee Work Area B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 144 Workroom 20.04 - Common Use Areas - Visual Alarms Visual alarms are not provided in common use area(s) of the building such as meeting and conference rooms, open office space, classrooms, cafeterias, filing and photocopy rooms, employee break rooms, dressing, examination, and treatment rooms, and similar spaces that are not used solely as employee work areas. 4.28.1 215.2; 702.1 907.9.1. 1 -EW - Employee Work Area B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 153 Office Page 1 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 20 - Alarms Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 20.04 - Common Use Areas - Visual Alarms Visual alarms are not provided in common use area(s) of the building such as meeting and conference rooms, open office space, classrooms, cafeterias, filing and photocopy rooms, employee break rooms, dressing, examination, and treatment rooms, and similar spaces that are not used solely as employee work areas. 4.28.1 215.2; 702.1 907.9.1. 1 -EW - Employee Work Area B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 158 Office 20.04 - Common Use Areas - Visual Alarms Visual alarms are not provided in common use area(s) of the building such as meeting and conference rooms, open office space, classrooms, cafeterias, filing and photocopy rooms, employee break rooms, dressing, examination, and treatment rooms, and similar spaces that are not used solely as employee work areas. 4.28.1 215.2; 702.1 907.9.1. 1 -EW - Employee Work Area B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 166 Library 20.04 - Common Use Areas - Visual Alarms Visual alarms are not provided in common use area(s) of the building such as meeting and conference rooms, open office space, classrooms, cafeterias, filing and photocopy rooms, employee break rooms, dressing, examination, and treatment rooms, and similar spaces that are not used solely as employee work areas. 4.28.1 215.2; 702.1 907.9.1. 1 -EW - Employee Work Area B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 185 Kitchen 20.04 - Common Use Areas - Visual Alarms Visual alarms are not provided in common use area(s) of the building such as meeting and conference rooms, open office space, classrooms, cafeterias, filing and photocopy rooms, employee break rooms, dressing, examination, and treatment rooms, and similar spaces that are not used solely as employee work areas. 4.28.1 215.2; 702.1 907.9.1. 1 -EW - Employee Work Area B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 203 Dishwashing Area Page 2 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 20 - Alarms Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 20.04 - Common Use Areas - Visual Alarms Visual alarms are not provided in common use area(s) of the building such as meeting and conference rooms, open office space, classrooms, cafeterias, filing and photocopy rooms, employee break rooms, dressing, examination, and treatment rooms, and similar spaces that are not used solely as employee work areas. 4.28.1 215.2; 702.1 907.9.1. 1 -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 243 Multipurpose Room 20.02 - Toilet, Bathroom, or Shower Room - Visual Alarms Visual alarms are not provided at public or common use toilet, bathroom, or shower room. 4.28.1 215.1; Advisory 215.1; 702.1 907.9.1. 1 -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 258 Men's Restroom 20.02 - Toilet, Bathroom, or Shower Room - Visual Alarms Visual alarms are not provided at public or common use toilet, bathroom, or shower room. 4.28.1 215.1; Advisory 215.1; 702.1 907.9.1. 1 -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 275 Women's Restroom 20.02 - Toilet, Bathroom, or Shower Room - Visual Alarms Visual alarms are not provided at public or common use toilet, bathroom, or shower room. 4.28.1 215.1; Advisory 215.1; 702.1 907.9.1. 1 -EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 291 Staff Restroom 20.18 - Other - Alarms See Additional Comments ----Approach to FE obstructed by wall. PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 308 Lobby Page 3 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 20 - Alarms Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 20.04 - Common Use Areas - Visual Alarms Visual alarms are not provided in common use area(s) of the building such as meeting and conference rooms, open office space, classrooms, cafeterias, filing and photocopy rooms, employee break rooms, dressing, examination, and treatment rooms, and similar spaces that are not used solely as employee work areas. 4.28.1 215.2; 702.1 907.9.1. 1 -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 310 Exhibit Room 20.04 - Common Use Areas - Visual Alarms Visual alarms are not provided in common use area(s) of the building such as meeting and conference rooms, open office space, classrooms, cafeterias, filing and photocopy rooms, employee break rooms, dressing, examination, and treatment rooms, and similar spaces that are not used solely as employee work areas. 4.28.1 215.2; 702.1 907.9.1. 1 -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 312 Exhibit Room 20.04 - Common Use Areas - Visual Alarms Visual alarms are not provided in common use area(s) of the building such as meeting and conference rooms, open office space, classrooms, cafeterias, filing and photocopy rooms, employee break rooms, dressing, examination, and treatment rooms, and similar spaces that are not used solely as employee work areas. 4.28.1 215.2; 702.1 907.9.1. 1 -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 316 Exhibit Room 20.02 - Toilet, Bathroom, or Shower Room - Visual Alarms Visual alarms are not provided at public or common use toilet, bathroom, or shower room. 4.28.1 215.1; Advisory 215.1; 702.1 907.9.1. 1 -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 327 Men's Restroom Page 4 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 20 - Alarms Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 20.04 - Common Use Areas - Visual Alarms Visual alarms are not provided in common use area(s) of the building such as meeting and conference rooms, open office space, classrooms, cafeterias, filing and photocopy rooms, employee break rooms, dressing, examination, and treatment rooms, and similar spaces that are not used solely as employee work areas. 4.28.1 215.2; 702.1 907.9.1. 1 -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 344 Exhibit Room 20.02 - Toilet, Bathroom, or Shower Room - Visual Alarms Visual alarms are not provided at public or common use toilet, bathroom, or shower room. 4.28.1 215.1; Advisory 215.1; 702.1 907.9.1. 1 -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 358 Women's Restroom 19Number of Key Notes for Group 20 - Alarms: Group 04 - Curb Ramps Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 04.10 - Detectable Warning Requirement Regardless of slope, the curb ramp does not have a detectable warning. 4.7.7; 4.29.2 705.1; Fig. 705.1 1127B.5 item 7 2005 PROWA G- R303.3. 2 PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 50 Curb Ramp 04.09A - Grooved Border Requirement Curb ramp does not have a 12” wide grooved border around upper edges of curb ramp and flares to indicate transition from sidewalk to curb ramp. --1127B.5 item 6 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 51 Curb Ramp 04.09A - Grooved Border Requirement Curb ramp does not have a 12” wide grooved border around upper edges of curb ramp and flares to indicate transition from sidewalk to curb ramp. --1127B.5 item 6 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 86 Bus Drop-off Page 5 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 04 - Curb Ramps Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 04.10 - Detectable Warning Requirement Regardless of slope, the curb ramp does not have a detectable warning. 4.7.7; 4.29.2 705.1; Fig. 705.1 1127B.5 item 7 2005 PROWA G- R303.3. 2 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 87 Bus Drop-off 4Number of Key Notes for Group 04 - Curb Ramps: Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.12 - Hardware Mounting Height Mounting height of all operating hardware is not 30” min.. or 44” max.., as measured to the highest operable part. (1994 ADA Standards permit a max.. height of 48"; CBC Standards permit a range of 30” min.. to 44” max..) 4.13.9 -1133B.2 .5.2 -61" to gate hardware.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 119 Terrace 11.15A - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -Door stop.EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 127 Studio 11.15B_04AG - Vision Lights Door, gate, or adjacent sidelight, containing one or more vision lights, does not include at least one vision light mounted with the bottom edge of the glazed panel at 43" max.. AFF. (Exception: Vision lights with the lowest part more than 66" AFF.) -404.2.1 1 --47 1/2" high.EW - Employee Work Area E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 128 Studio 11.25A - Raised Characters and Braille (Visual/Tactile Signs) The raised characters on this sign are not accompanied by California Grade 2 Braille (California Grade 2 Braille requires the dots within each cell to be domed and spaced 1/10” o.c.) 4.30.4 703.2; 703.3 1117B.5 .5 item 1, 1117B.5 .6 -EW - Employee Work Area D - Minor Code Deviation 2 - Program Areas (28 CFR 36.304(c)(2)) 129 Studio Page 6 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -2" strike clearance due to fixed counter. EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 130 Studio 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -EW - Employee Work Area E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 136 Studio 11.15B_04AG - Vision Lights Door, gate, or adjacent sidelight, containing one or more vision lights, does not include at least one vision light mounted with the bottom edge of the glazed panel at 43" max.. AFF. (Exception: Vision lights with the lowest part more than 66" AFF.) -404.2.1 1 --47 1/2" high.EW - Employee Work Area E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 137 Studio Page 7 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -No strike side clearance due to counter. EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 138 Studio 11.15A - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -Door stop.EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 139 Workroom 11.15B_04AG - Vision Lights Door, gate, or adjacent sidelight, containing one or more vision lights, does not include at least one vision light mounted with the bottom edge of the glazed panel at 43" max.. AFF. (Exception: Vision lights with the lowest part more than 66" AFF.) -404.2.1 1 --47 1/2" high.EW - Employee Work Area E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 140 Workroom 11.25A - Raised Characters and Braille (Visual/Tactile Signs) The raised characters on this sign are not accompanied by California Grade 2 Braille (California Grade 2 Braille requires the dots within each cell to be domed and spaced 1/10” o.c.) 4.30.4 703.2; 703.3 1117B.5 .5 item 1, 1117B.5 .6 -EW - Employee Work Area D - Minor Code Deviation 2 - Program Areas (28 CFR 36.304(c)(2)) 141 Workroom Page 8 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -Non-fixed furniture obstructs door strike clearance. EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 142 Workroom 11.13A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -9 LBF.EW - Employee Work Area B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 143 Workroom 11.25A - Raised Characters and Braille (Visual/Tactile Signs) The raised characters on this sign are not accompanied by California Grade 2 Braille (California Grade 2 Braille requires the dots within each cell to be domed and spaced 1/10” o.c.) 4.30.4 703.2; 703.3 1117B.5 .5 item 1, 1117B.5 .6 -EW - Employee Work Area D - Minor Code Deviation 2 - Program Areas (28 CFR 36.304(c)(2)) 149 Office 11.15B_04AG - Vision Lights Door, gate, or adjacent sidelight, containing one or more vision lights, does not include at least one vision light mounted with the bottom edge of the glazed panel at 43" max.. AFF. (Exception: Vision lights with the lowest part more than 66" AFF.) -404.2.1 1 --47 1/2" high.EW - Employee Work Area E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 150 Office Page 9 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -Non-fixed cabinets obstructs door strike clearance. EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 151 Office 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Twist type lock.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 152 Office 11.25A - Raised Characters and Braille (Visual/Tactile Signs) The raised characters on this sign are not accompanied by California Grade 2 Braille (California Grade 2 Braille requires the dots within each cell to be domed and spaced 1/10” o.c.) 4.30.4 703.2; 703.3 1117B.5 .5 item 1, 1117B.5 .6 -EW - Employee Work Area D - Minor Code Deviation 2 - Program Areas (28 CFR 36.304(c)(2)) 155 Office 11.15B_04AG - Vision Lights Door, gate, or adjacent sidelight, containing one or more vision lights, does not include at least one vision light mounted with the bottom edge of the glazed panel at 43" max.. AFF. (Exception: Vision lights with the lowest part more than 66" AFF.) -404.2.1 1 --47 1/2" high.EW - Employee Work Area E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 156 Office Page 10 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -Non-fixed cabinet obstruct door strike clearance. EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 157 Office 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Twist type lock.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 159 Office 11.15A - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -Door stop.EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 160 Library 11.15B_04AG - Vision Lights Door, gate, or adjacent sidelight, containing one or more vision lights, does not include at least one vision light mounted with the bottom edge of the glazed panel at 43" max.. AFF. (Exception: Vision lights with the lowest part more than 66" AFF.) -404.2.1 1 --47 1/2" high.EW - Employee Work Area E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 161 Library Page 11 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.25A - Raised Characters and Braille (Visual/Tactile Signs) The raised characters on this sign are not accompanied by California Grade 2 Braille (California Grade 2 Braille requires the dots within each cell to be domed and spaced 1/10” o.c.) 4.30.4 703.2; 703.3 1117B.5 .5 item 1, 1117B.5 .6 -EW - Employee Work Area D - Minor Code Deviation 2 - Program Areas (28 CFR 36.304(c)(2)) 162 Library 11.13A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -9 LBF.EW - Employee Work Area B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 163 Library 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -Non-fixed furniture obstructs door strike clearance. EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 164 Library 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 170 Hallway 11.14 - Closers Door closer is not adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3” from the latch (measured to the leading edge of the door). 4.13.10 404.2.8. 1 1133B.2 .5.1 -2.66 seconds.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 171 Hallway Page 12 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.23A - Mounting Location (Visual/Tactile Signs) Sign is not mounted on the wall adjacent to the latch side of the door. OR At double leaf doors, the sign is not placed on the nearest adjacent wall. 4.30.6 703.4.2 1117B.5 .7 -Sign on door.MS - Maintenance and Storage Only C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 172 Electrical Room 11.23B - Mounting Height (Visual/Tactile Signs) Sign is not mounted at 60” o.c. AFF to the centerline of the sign. (If the sign contains pictorial symbols (pictograms) or other non- tactile information, mounting height is measured to the centerline of the tactile characters / Braille portion of the sign.) 4.30.6 703.4.1 1117B.5 .7 -75" high.MS - Maintenance and Storage Only C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 173 Electrical Room 11.25A - Raised Characters and Braille (Visual/Tactile Signs) The raised characters on this sign are not accompanied by California Grade 2 Braille (California Grade 2 Braille requires the dots within each cell to be domed and spaced 1/10” o.c.) 4.30.4 703.2; 703.3 1117B.5 .5 item 1, 1117B.5 .6 -MS - Maintenance and Storage Only D - Minor Code Deviation 2 - Program Areas (28 CFR 36.304(c)(2)) 174 Electrical Room 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -EW - Employee Work Area E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 175 Kitchen 11.15A - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -Door stop.EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 176 Kitchen 11.13A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -8 LBF.EW - Employee Work Area B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 177 Kitchen Page 13 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -Counter obstructs door strike clearance. EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 178 Kitchen 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -EW - Employee Work Area E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 182 Kitchen 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -Kitchen counter obstructs door strike clearance. EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 183 Kitchen Page 14 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.07D - Floor Mat - Attachment to Floor Floor mat used on a ground or floor surface is not securely attached. 4.5.3 303.2; Advisory 302.2 1124B.3 -Loose floor mat.EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 184 Kitchen 11.14 - Closers Door closer is not adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3” from the latch (measured to the leading edge of the door). 4.13.10 404.2.8. 1 1133B.2 .5.1 -2.3 seconds.EW - Employee Work Area A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 190 Kitchen 11.25A - Raised Characters and Braille (Visual/Tactile Signs) The raised characters on this sign are not accompanied by California Grade 2 Braille (California Grade 2 Braille requires the dots within each cell to be domed and spaced 1/10” o.c.) 4.30.4 703.2; 703.3 1117B.5 .5 item 1, 1117B.5 .6 -EW - Employee Work Area D - Minor Code Deviation 2 - Program Areas (28 CFR 36.304(c)(2)) 191 Kitchen 11.23B - Mounting Height (Visual/Tactile Signs) Sign is not mounted at 60” o.c. AFF to the centerline of the sign. (If the sign contains pictorial symbols (pictograms) or other non- tactile information, mounting height is measured to the centerline of the tactile characters / Braille portion of the sign.) 4.30.6 703.4.1 1117B.5 .7 -59" high.PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 208 Multipurpose Room 11.25A - Raised Characters and Braille (Visual/Tactile Signs) The raised characters on this sign are not accompanied by California Grade 2 Braille (California Grade 2 Braille requires the dots within each cell to be domed and spaced 1/10” o.c.) 4.30.4 703.2; 703.3 1117B.5 .5 item 1, 1117B.5 .6 -PV - Public/Visitor Use D - Minor Code Deviation 2 - Program Areas (28 CFR 36.304(c)(2)) 211 Multipurpose Room 11.14 - Closers Door closer is not adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3” from the latch (measured to the leading edge of the door). 4.13.10 404.2.8. 1 1133B.2 .5.1 -2.6 seconds.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 212 Multipurpose Room Page 15 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.15B_04AG - Vision Lights Door, gate, or adjacent sidelight, containing one or more vision lights, does not include at least one vision light mounted with the bottom edge of the glazed panel at 43" max.. AFF. (Exception: Vision lights with the lowest part more than 66" AFF.) -404.2.1 1 --48 1/2" high.EW - Employee Work Area E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 214 Kitchen 11.13A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -7 LBF.EW - Employee Work Area B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 215 Kitchen 11.25A - Raised Characters and Braille (Visual/Tactile Signs) The raised characters on this sign are not accompanied by California Grade 2 Braille (California Grade 2 Braille requires the dots within each cell to be domed and spaced 1/10” o.c.) 4.30.4 703.2; 703.3 1117B.5 .5 item 1, 1117B.5 .6 -EW - Employee Work Area D - Minor Code Deviation 2 - Program Areas (28 CFR 36.304(c)(2)) 216 Kitchen 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -Kitchen counter obstructs door strike clearance. EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 217 Kitchen Page 16 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.25A - Raised Characters and Braille (Visual/Tactile Signs) The raised characters on this sign are not accompanied by California Grade 2 Braille (California Grade 2 Braille requires the dots within each cell to be domed and spaced 1/10” o.c.) 4.30.4 703.2; 703.3 1117B.5 .5 item 1, 1117B.5 .6 -PV - Public/Visitor Use D - Minor Code Deviation 2 - Program Areas (28 CFR 36.304(c)(2)) 220 Multipurpose Room 11.13A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -9 LBF.EW - Employee Work Area B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 226 Kitchen 11.15B_04AG - Vision Lights Door, gate, or adjacent sidelight, containing one or more vision lights, does not include at least one vision light mounted with the bottom edge of the glazed panel at 43" max.. AFF. (Exception: Vision lights with the lowest part more than 66" AFF.) -404.2.1 1 --48 1/2" high.EW - Employee Work Area E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 227 Kitchen 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -Kitchen counter obstructs door strike clearance. EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 228 Kitchen 11.07D - Floor Mat - Attachment to Floor Floor mat used on a ground or floor surface is not securely attached. 4.5.3 303.2; Advisory 302.2 1124B.3 -Loose floor mat.EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 229 Kitchen Page 17 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.14 - Closers Door closer is not adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3” from the latch (measured to the leading edge of the door). 4.13.10 404.2.8. 1 1133B.2 .5.1 -1.6 seconds.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 237 Multipurpose Room 11.25A - Raised Characters and Braille (Visual/Tactile Signs) The raised characters on this sign are not accompanied by California Grade 2 Braille (California Grade 2 Braille requires the dots within each cell to be domed and spaced 1/10” o.c.) 4.30.4 703.2; 703.3 1117B.5 .5 item 1, 1117B.5 .6 -PV - Public/Visitor Use D - Minor Code Deviation 2 - Program Areas (28 CFR 36.304(c)(2)) 239 Multipurpose Room 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 244 Multipurpose Room 11.13A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -30 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 245 Multipurpose Room 11.07D - Floor Mat - Attachment to Floor Floor mat used on a ground or floor surface is not securely attached. 4.5.3 303.2; Advisory 302.2 1124B.3 -Loose floor mat.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 246 Lobby 11.17B - Room/Space Identification Signs (Visual/Tactile Signs) Sign designating the permanent room or space does not comply with ADAAG and CBC requirements for tactile signs. 4.1.2(7) ; 4.30.1, 4, 5, 6 216.2; 703.1; 703.2; 703.5 1117B.5 .2, 3, 5, 6, 7 -PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 248 Lobby Page 18 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.23A - Mounting Location (Visual/Tactile Signs) Sign is not mounted on the wall adjacent to the latch side of the door. OR At double leaf doors, the sign is not placed on the nearest adjacent wall. 4.30.6 703.4.2 1117B.5 .7 -Sing on door.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 252 Lobby 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 253 Multipurpose Room 11.13A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -10 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 254 Multipurpose Room 11.14 - Closers Door closer is not adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3” from the latch (measured to the leading edge of the door). 4.13.10 404.2.8. 1 1133B.2 .5.1 -2.5 seconds.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 255 Multipurpose Room 11.07D - Floor Mat - Attachment to Floor Floor mat used on a ground or floor surface is not securely attached. 4.5.3 303.2; Advisory 302.2 1124B.3 -Loose floor mat.MS - Maintenance and Storage Only A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 266 Janitor Closet 11.23B - Mounting Height (Visual/Tactile Signs) Sign is not mounted at 60” o.c. AFF to the centerline of the sign. (If the sign contains pictorial symbols (pictograms) or other non- tactile information, mounting height is measured to the centerline of the tactile characters / Braille portion of the sign.) 4.30.6 703.4.1 1117B.5 .7 -59" high.MS - Maintenance and Storage Only C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 267 Janitor Closet Page 19 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.25A - Raised Characters and Braille (Visual/Tactile Signs) The raised characters on this sign are not accompanied by California Grade 2 Braille (California Grade 2 Braille requires the dots within each cell to be domed and spaced 1/10” o.c.) 4.30.4 703.2; 703.3 1117B.5 .5 item 1, 1117B.5 .6 -Bad Braille.MS - Maintenance and Storage Only D - Minor Code Deviation 2 - Program Areas (28 CFR 36.304(c)(2)) 268 Janitor Closet 11.15A - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -Door stop.MS - Maintenance and Storage Only A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 269 Janitor Closet 11.13A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -10 LBF.MS - Maintenance and Storage Only B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 270 Janitor Closet 11.13A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -10 LBF.MS - Maintenance and Storage Only B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 297 Storage Room 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -MS - Maintenance and Storage Only E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 298 Storage Room 11.15A - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -Door stop.MS - Maintenance and Storage Only A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 300 Storage Room Page 20 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Twist type lock.MS - Maintenance and Storage Only C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 301 Storage Room 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -13" strike clearance on pull side. MS - Maintenance and Storage Only C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 303 Storage Room 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -EW - Employee Work Area E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 305 Office 11.15A - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -Door stop.EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 306 Office Page 21 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Twist type lock.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 307 Office 11.23B - Mounting Height (Visual/Tactile Signs) Sign is not mounted at 60” o.c. AFF to the centerline of the sign. (If the sign contains pictorial symbols (pictograms) or other non- tactile information, mounting height is measured to the centerline of the tactile characters / Braille portion of the sign.) 4.30.6 703.4.1 1117B.5 .7 -58" high.PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 314 Exhibit Room 11.25A - Raised Characters and Braille (Visual/Tactile Signs) The raised characters on this sign are not accompanied by California Grade 2 Braille (California Grade 2 Braille requires the dots within each cell to be domed and spaced 1/10” o.c.) 4.30.4 703.2; 703.3 1117B.5 .5 item 1, 1117B.5 .6 -Bad Braille.PV - Public/Visitor Use D - Minor Code Deviation 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 315 Exhibit Room 11.25A - Raised Characters and Braille (Visual/Tactile Signs) The raised characters on this sign are not accompanied by California Grade 2 Braille (California Grade 2 Braille requires the dots within each cell to be domed and spaced 1/10” o.c.) 4.30.4 703.2; 703.3 1117B.5 .5 item 1, 1117B.5 .6 -MS - Maintenance and Storage Only D - Minor Code Deviation 2 - Program Areas (28 CFR 36.304(c)(2)) 318 Fire Alarm Room 11.23A - Mounting Location (Visual/Tactile Signs) Sign is not mounted on the wall adjacent to the latch side of the door. OR At double leaf doors, the sign is not placed on the nearest adjacent wall. 4.30.6 703.4.2 1117B.5 .7 -On door.MS - Maintenance and Storage Only C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 319 Fire Alarm Room 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -MS - Maintenance and Storage Only E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 342 Electrical room Page 22 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.14 - Closers Door closer is not adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3” from the latch (measured to the leading edge of the door). 4.13.10 404.2.8. 1 1133B.2 .5.1 -2.3 seconds.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 349 Exhibit Room 11.23B - Mounting Height (Visual/Tactile Signs) Sign is not mounted at 60” o.c. AFF to the centerline of the sign. (If the sign contains pictorial symbols (pictograms) or other non- tactile information, mounting height is measured to the centerline of the tactile characters / Braille portion of the sign.) 4.30.6 703.4.1 1117B.5 .7 -59" high.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 351 Exhibit Room 11.25A - Raised Characters and Braille (Visual/Tactile Signs) The raised characters on this sign are not accompanied by California Grade 2 Braille (California Grade 2 Braille requires the dots within each cell to be domed and spaced 1/10” o.c.) 4.30.4 703.2; 703.3 1117B.5 .5 item 1, 1117B.5 .6 -Bad Braille.PV - Public/Visitor Use D - Minor Code Deviation 2 - Program Areas (28 CFR 36.304(c)(2)) 352 Exhibit Room 83Number of Key Notes for Group 11 - Doors and Gates: Group 05 - Drinking Fountains Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 05.05A - Knee Space Height Drinking fountain provides less than 27” high accessible knee clearance between the bottom of the apron and the floor. 4.15.5(1 ); Figs. 27(a) and (b) 306.3; Fig. 306.3 1115B.4 .6 item 2 -26 3/4" high.PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 96 Entry Plaza 05.05A - Knee Space Height Drinking fountain provides less than 27” high accessible knee clearance between the bottom of the apron and the floor. 4.15.5(1 ); Figs. 27(a) and (b) 306.3; Fig. 306.3 1115B.4 .6 item 2 -26 3/4" high.PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 125 Lobby Page 23 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 05 - Drinking Fountains Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 05.11 - Water Flow - Round or Oval Bowl For a fountain with a round or oval bowl, the water flow is not within 3” of the fountain's front edge. 4.15.3 -1115B.4 .6 item 5 -4" from front edge.PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 126 Lobby 3Number of Key Notes for Group 05 - Drinking Fountains: Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.08 - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -None provided.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 118 Terrace 10.09B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -Compound threshold.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 120 Lobby 10.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -8 LBF. at non-motorized door.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 121 Lobby 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 122 Lobby Page 24 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.08 - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -Door stop.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 167 Hallway 10.11B - Hardware Operating Effort The force required to activate handles, pulls, latches, locks, and other operable parts of door exceeds 5 lbs. 4.27.4 309.4 1117B.6 item 4 -6 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 168 Hallway 10.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -14 LBF., (fire rated door).PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 169 Hallway 10.08 - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -Door stop.EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 186 Kitchen 10.13B - Exit Door Signs At grade level exterior exit door, a non- compliant exit sign with the word “EXIT” in raised characters and Braille is mounted on the wall adjacent to the latch side of the door (e.g.. Braille symbols are not California Grade 2 Braille). 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1117B.5 .1 item 1 -Non-compliant Braille.EW - Employee Work Area D - Minor Code Deviation 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 187 Kitchen Page 25 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Twist type lock.EW - Employee Work Area C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 188 Kitchen 10.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -7 LBF., (fire rated door).EW - Employee Work Area B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 189 Kitchen 10.13B - Exit Door Signs At grade level exterior exit door, a non- compliant exit sign with the word “EXIT” in raised characters and Braille is mounted on the wall adjacent to the latch side of the door (e.g.. Braille symbols are not California Grade 2 Braille). 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1117B.5 .1 item 1 -PV - Public/Visitor Use D - Minor Code Deviation 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 207 Multipurpose Room 10.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -10 LBF., (fire rated door).PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 209 Multipurpose Room 10.08 - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -Door stop.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 210 Multipurpose Room 10.09A - > 1/4" Changes in Level - Threshold Where threshold is 1/4" min.. to 1/2" max.. in height, change in level is not beveled at 1:2 or less. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -5.3% slope at threshold.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 213 Multipurpose Room Page 26 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 221 Multipurpose Room 10.08 - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -Door stops.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 222 Multipurpose Room 10.11B - Hardware Operating Effort The force required to activate handles, pulls, latches, locks, and other operable parts of door exceeds 5 lbs. 4.27.4 309.4 1117B.6 item 4 -10 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 223 Multipurpose Room 10.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -17 and 20 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 224 Multipurpose Room 10.05 - Clear Door Opening When the door is open 90 degrees, clear opening width is not at least 32” measured between the face of the door and the doorstop on the latch side. 4.13.5 404.2.3; Fig. 404.2.3 1133B.1 .1.1.1; 1133B.2 .2 -31" wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 225 Multipurpose Room 10.09B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -1/2" high at two locations.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 230 Multipurpose Room Page 27 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -None provided.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 231 Multipurpose Room 10.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -Greater than 5 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 232 Multipurpose Room 10.08 - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -Door stop.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 233 Multipurpose Room 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 234 Multipurpose Room 10.11B - Hardware Operating Effort The force required to activate handles, pulls, latches, locks, and other operable parts of door exceeds 5 lbs. 4.27.4 309.4 1117B.6 item 4 -9 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 235 Multipurpose Room 10.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -10 and 12 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 236 Multipurpose Room Page 28 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.05 - Clear Door Opening When the door is open 90 degrees, clear opening width is not at least 32” measured between the face of the door and the doorstop on the latch side. 4.13.5 404.2.3; Fig. 404.2.3 1133B.1 .1.1.1; 1133B.2 .2 -31" wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 238 Multipurpose Room 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 247 Lobby 10.08 - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -Door stop.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 249 Lobby 10.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab.404 .2.4.1; Fig.404. 2.4.1 1133B.2 .4.2; Fig. 11B-26 -18" strike clearance on pull side in lieu of 24". PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 250 Lobby 10.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -13 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 251 Lobby Page 29 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.08 - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -Door stop.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 313 Exhibit Room 10.09B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -2 1/2" high.MS - Maintenance and Storage Only C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 343 Electrical room 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 345 Exhibit Room 10.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab.404 .2.4.1; Fig.404. 2.4.1 1133B.2 .4.2; Fig. 11B-26 -No strike side clearance due to exhibit wall. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 346 Exhibit Room 10.11B - Hardware Operating Effort The force required to activate handles, pulls, latches, locks, and other operable parts of door exceeds 5 lbs. 4.27.4 309.4 1117B.6 item 4 -7 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 347 Exhibit Room Page 30 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -14 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 348 Exhibit Room 10.07A - Landing - Level and Clear Floor is not level (slope is greater than 2% in some or all directions). OR Floor is not clear within the required maneuvering space. 4.13.6; Fig. 25 305; 404.2.4. 4 1133B.2 .4 -8.7% CS & 9.2% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 350 Exhibit Room 39Number of Key Notes for Group 10 - Entrances and Exits: Group 15A - Large Assembly Areas Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 15A.33 - Accessible Assembly Seating In assembly areas with fixed seating, the required number of accessible seating is not provided. (Seating Capacity // W // C // S // A // ALS Receiver) (4 to 26 // 1 // 1 // 2 // 1 // 2) (27 to 50 // 2 // 2 // 2 // 1 // 2) (51 to 100 // 4 // 4 // 2 // 1 // 4%) (101 to 200 // 4 // 4 // 2 // 1% // 4%) (201 to 300 // 4 // 4 // 1% // 1% // 4%) (301 to 500 // 6 // 6 // 1% // 1% // 4%) (501 + // 6 + 1 per add. 100 seats over 500 // 6 + 1 per add. 100 seats over 500 // 1% // 1% // 4% ) W= Wheelchair spaces, A= Aisle (transfer) seats, C= Companion seats , S= Semi-ambulant seats 4.1.3(19 )(a); 4.33.3 221.2.1; 221.2.1. 1; Tab. 221.2.1. 1; 221.3; 221.4 1104B.3 .1, 5; Table 11B-1 -147 seats at Amphitheater (approx.) PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 54 Amphitheater Page 31 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 15A - Large Assembly Areas Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 15A.37 - Placement of Wheelchair Areas The wheelchair areas are not an integral part of the fixed seating plan with a choice of admission prices and lines of sight comparable to those for the general public. 4.33.3 221.2.2; Advisory 221.2.2; 221.2.3; Advisory 221.2.3 1104B.3 .5 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 55 Amphitheater 15A.45 - Accessible Route - Performing Areas Accessible routes of travel do not connect wheelchair seating locations and performance areas including stages, arena floors, dressing rooms, locker rooms, and other spaces used by performers. 4.33.5 206.2.4; 206.2.6 1104B.3 .10 -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 56 Amphitheater 15A.30 - Portable ALS For assembly areas without fixed seats (e.g.. conference or meeting rooms), a permanently installed assistive listening system or a portable assistive listening system, including an adequate number of electrical outlets or other supplementary wiring necessary to support a portable ALS, has not been provided. (A permanently installed ALS is required where (1) the assembly area accommodates 50 or more persons or has an audio-amplification system and (2) it has fixed seats.) (If portable assistive- listening systems are used for conference or meeting rooms, the system may serve more than one room.) 4.1.3(19 )(b) 219.2; 219.3; Tab. 219.3 1104B.2 item 6 -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 57 Amphitheater 15A.49 - Other - Large Assembly Areas See Additional Comments ----14 1/2" high Seats.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 58 Amphitheater Page 32 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 15A - Large Assembly Areas Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 5Number of Key Notes for Group 15A - Large Assembly Areas: Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.03 - Facilities Connected Accessible routes of travel do not connect all accessible buildings, facilities, elements and spaces on the same site with one another. 4.1.2(2) (a) 206.2.2; Advisory 206.2.2 1114B.1 .2; 1127B.1 -No accessible POT connects to vista point. PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 1 Vista Point 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.1% to 2.7% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 5 Vista Point 03B.10 - Running Slope Slope of the accessible route of travel exceeds 1:20. 4.3.7 403.3 1133B.7 .3 -5.55 to 6.8% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 6 Vista Point 03B.13 - > 1/2" Changes in Level Curb ramps, ramps, or elevators are not used for changes in level greater than 1/2 inch. (Lifts may only be used in certain limited situations.) 4.5.2 303.4 1124B.2 -1/2" level change.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 7 Vista Point 03B.13 - > 1/2" Changes in Level Curb ramps, ramps, or elevators are not used for changes in level greater than 1/2 inch. (Lifts may only be used in certain limited situations.) 4.5.2 303.4 1124B.2 -3/4" level change from concrete to asphalt. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 8 Vista Point 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.1% to 7.7% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 9 Seascape Path Page 33 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.10 - Running Slope Slope of the accessible route of travel exceeds 1:20. 4.3.7 403.3 1133B.7 .3 -6.3% to 6.5% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 10 Seascape Path 03B.10 - Running Slope Slope of the accessible route of travel exceeds 1:20. 4.3.7 403.3 1133B.7 .3 -8.6% RS at resting space.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 11 Seascape Path 03B.13 - > 1/2" Changes in Level Curb ramps, ramps, or elevators are not used for changes in level greater than 1/2 inch. (Lifts may only be used in certain limited situations.) 4.5.2 303.4 1124B.2 -1/2" level change.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 12 Seascape Path 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -4.5% to 9.7% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 13 Seascape Path 03B.10 - Running Slope Slope of the accessible route of travel exceeds 1:20. 4.3.7 403.3 1133B.7 .3 -5.3% to 10.5% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 14 Seascape Path 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -3% to 9.5% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 15 Seascape Path 03B.10 - Running Slope Slope of the accessible route of travel exceeds 1:20. 4.3.7 403.3 1133B.7 .3 -5.6% to 8.7% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 16 Seascape Path Page 34 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.5% to 14.1% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 19 Seascape Path 03B.10 - Running Slope Slope of the accessible route of travel exceeds 1:20. 4.3.7 403.3 1133B.7 .3 -5.25 to 10.7% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 20 Seascape Path 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -3.7% to 13.4% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 21 Seascape Path 03B.10 - Running Slope Slope of the accessible route of travel exceeds 1:20. 4.3.7 403.3 1133B.7 .3 -5.3%.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 22 Seascape Path 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -3.85 to 7.7% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 23 Seascape Path 03B.10 - Running Slope Slope of the accessible route of travel exceeds 1:20. 4.3.7 403.3 1133B.7 .3 -5.3% to 10.9% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 24 Seascape Path 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -6.4% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 29 Seascape Path Page 35 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.13 - > 1/2" Changes in Level Curb ramps, ramps, or elevators are not used for changes in level greater than 1/2 inch. (Lifts may only be used in certain limited situations.) 4.5.2 303.4 1124B.2 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 36 ORAR 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.8% to 4.0% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 49 Sidewalk 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.4% to 4.0% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 75 Bus Drop-off 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.1% to 6.7% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 82 Entry Plaza 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -3.9%.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 83 Bus Drop-off 03B.10 - Running Slope Slope of the accessible route of travel exceeds 1:20. 4.3.7 403.3 1133B.7 .3 -9.2%.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 84 Bus Drop-off 03B.19B - Directional Signs Directional signs, utilizing the ISA and visible to persons along approaching circulation paths, are not provided at junctions where the accessible route of travel diverges from the regular circulation path. 4.1.2(7) 216.3; Advisory 216.3; 703.5 1127B.3 -ISA sign has no arrow to direct people to accessible POT. PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 85 Bus Drop-off Page 36 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.3% to 4.5% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 91 Entry Plaza 03B.13 - > 1/2" Changes in Level Curb ramps, ramps, or elevators are not used for changes in level greater than 1/2 inch. (Lifts may only be used in certain limited situations.) 4.5.2 303.4 1124B.2 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 92 Entry Plaza 03B.22 - Other - On-Site Accessible Path of Travel See Additional Comments ----1" gap.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 93 Entry Plaza 03B.22 - Other - On-Site Accessible Path of Travel See Additional Comments ----1" gap at two locations.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 94 Entry Plaza 03B.12 - > 1/4" Changes in Level Where walkway levels change abruptly, the vertical difference between them exceeds 1/4 inch. Or changes in level between 1/4 inch and 1/2 inch are beveled with a slope greater than 1:2. 4.5.2 303.2; 303.3 1124B.2 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 95 Entry Plaza 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.3% to 3.7% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 97 Entry Plaza 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.5%.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 98 Entry Plaza Page 37 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -3.9% to 6.9% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 108 Terrace 03B.12 - > 1/4" Changes in Level Where walkway levels change abruptly, the vertical difference between them exceeds 1/4 inch. Or changes in level between 1/4 inch and 1/2 inch are beveled with a slope greater than 1:2. 4.5.2 303.2; 303.3 1124B.2 -1/2" level change PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 114 Terrace 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.4% to 6.1% CS at seven locations. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 115 Terrace 03B.22 - Other - On-Site Accessible Path of Travel See Additional Comments ----1/2" to 3/4" gap between concrete slabs. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 117 Terrace 38Number of Key Notes for Group 03B - On-Site Path of Travel: Group 01 - Parking Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 01.19B - Tow- away Sign A California tow-away sign is not posted in a conspicuous place at each entrance to off–street parking lot, or immediately adjacent to and visible from each accessible stall. --1129B.4 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 40 Parking 01.15C - Minimum Fine Sign Accessible parking space has no sign stating "Minimum Fine $250" below the ISA. --1129B.4 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 41 Parking Page 38 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 01 - Parking Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 01.06 - Lot Layout Parking stalls are so arranged that persons with disabilities are compelled to wheel or walk behind parked cars other than their own. -Advisory 502.3 1129B.3 item 3 PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 42 Parking 01.10A - Van Access Aisle - Dimensions Where the parking space is designated as "van accessible," the adjacent access aisle is not at least 8’ wide by 18’ long. (Aisle width is measured from the center line of the stripe on one side to the center line of the stripe on the other.) 4.1.2(5) (b) -1129B.3 item 2 18' long x 7'-9" wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 43 Parking 01.11 - Car Access Aisle - Dimensions Car access aisle is not at least 5’ wide and 18’ long. (Aisle width is measured from the center line of the stripe on one side to the center line of the stripe on the other.) 4.1.2(5) (a) 502.3.1 1129B.3 item 1 18' long x 4'-8" wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 44 Parking 01.18 - Pavement Sign A 36” square ISA is not painted on the pavement at the rear of the stall. -502.6 1129B.4 36" x 42".PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 45 Parking 01.02 - Number - Accessible Parking Spaces Where parking spaces are provided for self- parking by employees or visitors or both, the required number of accessible parking spaces is not provided. (Note: All or some of the accessible parking spaces may be in a different location if equivalent or greater accessibility is ensured.) (Spaces required: (1 to 25 // 1) (26 to 50 // 2) (51 to 75 // 3) (76 to 100 // 4) (101 to 150 // 5) (151 to 200 // 6) (201 to 300 // 7) (301 to 400 // 8) (401 to 500 // 9) (501 to 1,000 // *) (1,000 and over // **) (*Two percent of total.) (**Twenty plus one for each 100, or fraction over 1,001.) 4.1.2(5) 208.3.1( 2) 1129B.1 ; 1129B.2 ; Table 11B-6 27 parking stalls, 0 accessible.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 52 Parking Page 39 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 01 - Parking Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 01.19B - Tow- away Sign A California tow-away sign is not posted in a conspicuous place at each entrance to off–street parking lot, or immediately adjacent to and visible from each accessible stall. --1129B.4 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 53 Parking 8Number of Key Notes for Group 01 - Parking: Group 30 - Parks Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 30.02 - On-site Accessible Route of Travel There is no accessible route within the property line of the site linking accessible site elements with site arrival points serving the following, if provided: public transportation stops, accessible parking, passenger loading zones, and public sidewalks. 4.1.2(1) 202.2.1; Advisory 206.2.1 1114B.1 .2; 1127B.1 -No access to point of view.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 2 Vista Point 30.25 - Number - Accessible Picnic Tables Where fixed picnic tables are provided in a picnic area, the required number of fixed picnic tables is not provided. (1999 ADAAG: Where two or more fixed picnic tables are provided in a picnic area, at least 50%, but never less than two, shall comply with 16.5.4 through 16.5.6. In addition, at least 40%, but never less than two, of the accessible picnic tables shall be connected to an outdoor recreation access route complying with 16.3.) ---1999 ADAAG- 16.5.1.2 4 picnic tables, 0 accessible.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 17 Picnic Area 30.24 - Picnic Table - Accessible Route Picnic table is not accessible. OR Picnic table is not connected to an outdoor recreation access route. --1127B.1 ; 1132B.2 1999 ADAAG- 16.5.1.1 PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 18 Picnic Area Page 40 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 30 - Parks Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 30.02 - On-site Accessible Route of Travel There is no accessible route within the property line of the site linking accessible site elements with site arrival points serving the following, if provided: public transportation stops, accessible parking, passenger loading zones, and public sidewalks. 4.1.2(1) 202.2.1; Advisory 206.2.1 1114B.1 .2; 1127B.1 -PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 25 Vista Point 30.25 - Number - Accessible Picnic Tables Where fixed picnic tables are provided in a picnic area, the required number of fixed picnic tables is not provided. (1999 ADAAG: Where two or more fixed picnic tables are provided in a picnic area, at least 50%, but never less than two, shall comply with 16.5.4 through 16.5.6. In addition, at least 40%, but never less than two, of the accessible picnic tables shall be connected to an outdoor recreation access route complying with 16.3.) ---1999 ADAAG- 16.5.1.2 6 picnic tables, 1 with ISA Sign w/ water pond at asphalt. PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 30 Picnic Area 30.28 - Picnic Site - Surface Slope The accessible picnic site is located on a surface area with slope greater than 2% in some or all directions.(1999 ADAAG: 3% slope is allowed when necessary for drainage). 4.3.7 403.3 -1999 ADAAG- 16.5.7 12.2% RS from asphalt path to picnic area, 2.1% to 4.5% around picnic table. PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 31 Picnic Area 30.29 - Picnic Site Surface Picnic tables and benches are not on a firm and stable surface. ---1999 ADAAG- 16.5.6 Loose surface.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 32 Picnic Area 30.32 - 36" Aisle Width Standard Around the picnic table, there is less than 36" clear space measured from the seat. ---1999 ADAAG- 16.5.5 30" and 32" Aisle width at picnic table. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 33 Picnic Area Page 41 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 30 - Parks Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 30.47 - Trash & Recycling Receptacles - Location The picnic area does not provide a trash receptacle at the site or on an accessible route to the site. ---1999 ADAAG- 16.8.1 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 34 Picnic Area 30.68 - Other - Parks See Additional Comments ----Loose surface at dog waste bag area. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 35 Picnic Area 30.06E - Outdoor Recreation Access Route (ORAR) Segment - Cross Slope Cross slope of the access route segment exceeds 3.33%. Exception: Cross slopes of 5% maximum are permitted to ensure proper drainage. ---1999 ADAAG- 16.3.7.1 3.9% to 8.0% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 37 ORAR 30.68 - Other - Parks See Additional Comments ----Water erosion.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 38 ORAR 30.06A - Outdoor Recreation Access Route (ORAR) Segment - Running Slope Running slope of access route segment in the direction of travel does not comply with the following: a. 5% or less for any distance. b. From 5.1% to 8.33% for 50' maximum. c. From 8.34% to 10% for 30' maximum. ---1999 ADAAG- 16.3.7.2 .1; 16.3.7.2 .2; 16.3.7.2 .3 8.1% RS at middle of P.O.T. and 12.3% RS at end of ORAR. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 39 ORAR 30.68 - Other - Parks See Additional Comments ----3/4" level change.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 59 California Native Plant Garden Page 42 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 30 - Parks Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 30.06E - Outdoor Recreation Access Route (ORAR) Segment - Cross Slope Cross slope of the access route segment exceeds 3.33%. Exception: Cross slopes of 5% maximum are permitted to ensure proper drainage. ---1999 ADAAG- 16.3.7.1 4.9% to 10.3% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 60 California Native Plant Garden 30.06E - Outdoor Recreation Access Route (ORAR) Segment - Cross Slope Cross slope of the access route segment exceeds 3.33%. Exception: Cross slopes of 5% maximum are permitted to ensure proper drainage. ---1999 ADAAG- 16.3.7.1 4.8% to 14.1% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 61 California Native Plant Garden 30.06A - Outdoor Recreation Access Route (ORAR) Segment - Running Slope Running slope of access route segment in the direction of travel does not comply with the following: a. 5% or less for any distance. b. From 5.1% to 8.33% for 50' maximum. c. From 8.34% to 10% for 30' maximum. ---1999 ADAAG- 16.3.7.2 .1; 16.3.7.2 .2; 16.3.7.2 .3 6.5% to 14.7% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 62 California Native Plant Garden 30.68 - Other - Parks See Additional Comments ----Level change due to water erosion. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 63 California Native Plant Garden 30.06E - Outdoor Recreation Access Route (ORAR) Segment - Cross Slope Cross slope of the access route segment exceeds 3.33%. Exception: Cross slopes of 5% maximum are permitted to ensure proper drainage. ---1999 ADAAG- 16.3.7.1 5.1% to 10.0% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 64 California Native Plant Garden Page 43 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 30 - Parks Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 30.06A - Outdoor Recreation Access Route (ORAR) Segment - Running Slope Running slope of access route segment in the direction of travel does not comply with the following: a. 5% or less for any distance. b. From 5.1% to 8.33% for 50' maximum. c. From 8.34% to 10% for 30' maximum. ---1999 ADAAG- 16.3.7.2 .1; 16.3.7.2 .2; 16.3.7.2 .3 12.9% to 20.0% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 65 California Native Plant Garden 30.06E - Outdoor Recreation Access Route (ORAR) Segment - Cross Slope Cross slope of the access route segment exceeds 3.33%. Exception: Cross slopes of 5% maximum are permitted to ensure proper drainage. ---1999 ADAAG- 16.3.7.1 3.7% to 10.3% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 66 California Native Plant Garden 30.06A - Outdoor Recreation Access Route (ORAR) Segment - Running Slope Running slope of access route segment in the direction of travel does not comply with the following: a. 5% or less for any distance. b. From 5.1% to 8.33% for 50' maximum. c. From 8.34% to 10% for 30' maximum. ---1999 ADAAG- 16.3.7.2 .1; 16.3.7.2 .2; 16.3.7.2 .3 7.1% to 12.2% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 67 California Native Plant Garden 30.06E - Outdoor Recreation Access Route (ORAR) Segment - Cross Slope Cross slope of the access route segment exceeds 3.33%. Exception: Cross slopes of 5% maximum are permitted to ensure proper drainage. ---1999 ADAAG- 16.3.7.1 8.0% to 14.3% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 68 California Native Plant Garden Page 44 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 30 - Parks Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 30.06A - Outdoor Recreation Access Route (ORAR) Segment - Running Slope Running slope of access route segment in the direction of travel does not comply with the following: a. 5% or less for any distance. b. From 5.1% to 8.33% for 50' maximum. c. From 8.34% to 10% for 30' maximum. ---1999 ADAAG- 16.3.7.2 .1; 16.3.7.2 .2; 16.3.7.2 .3 11.8% to 23.4% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 69 California Native Plant Garden 30.68 - Other - Parks See Additional Comments ----Level change due to water erosion. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 70 California Native Plant Garden 30.15 - Fixed Bench - Ground/Floor Surface The surface around the accessible bench is not firm or stable. ---1999 ADAAG- 16.12.6 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 71 California Native Plant Garden 30.16 - Fixed Bench / Wheelchair Seating Space - Shoulder Alignment A clear space at least 30" x 48" in size has not been provided at one end of the fixed bench so that a wheelchair user may be seated shoulder- to-shoulder with an individual seated on the bench. ---1999 ADAAG- 16.12.4 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 72 California Native Plant Garden 30.17 - Fixed Bench - Surface Slope Clear space has a slope greater than 2% in some or all directions.(1999 ADAAG: 3% slope is allowed when necessary for drainage). 4.3.7 403.3 -1999 ADAAG- 16.12.7 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 73 California Native Plant Garden 30.22 - Fixed Bench Armrest Less than 50% of the fixed benches required to be accessible have at least one armrest that can withstand 250 lbs. of force in any direction. 4.26.3 903.6 1115B.7 .2 1999 ADAAG- 16.12.2. 2; 16.12.8 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 74 California Native Plant Garden Page 45 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 30 - Parks Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 30.21 - Fixed Bench Size Accessible bench does not have seats that are 20" to 24" in depth and 42" min. in length. OR The back support does not extend from a point 2" maximum above the bench to 18" min. above the bench. -903.3 903.4 Fig. 903.4 --Back support extends 14" from seat, 7 1/2" above bench. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 101 Entry Plaza 30.22 - Fixed Bench Armrest Less than 50% of the fixed benches required to be accessible have at least one armrest that can withstand 250 lbs. of force in any direction. 4.26.3 903.6 1115B.7 .2 1999 ADAAG- 16.12.2. 2; 16.12.8 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 102 Entry Plaza 30.20 - Fixed Bench - Back Support Back support is not provided along the full length of the accessible bench. -903.4 -1999 ADAAG- 16.12.5 Back support does not run the full length of the bench. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 103 Entry Plaza 30.19 - Fixed Bench Height The height of the front edge of the seating surface is not between 17" and 19" above the adjacent grade or floor space. -903.5 -1999 ADAAG- 16.12.3 16" high.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 104 Entry Plaza 30.13 - Number and Dispersal - Accessible Fixed Benches Less than 50% of the fixed benches being provided in an area are accessible. OR They are not dispersed among the types provided. ---1999 ADAAG- 16.12.2. 2; 16.12.2 6 benches, 0 accessible.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 105 Entry Plaza 30.16 - Fixed Bench / Wheelchair Seating Space - Shoulder Alignment A clear space at least 30" x 48" in size has not been provided at one end of the fixed bench so that a wheelchair user may be seated shoulder- to-shoulder with an individual seated on the bench. ---1999 ADAAG- 16.12.4 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 106 Entry Plaza Page 46 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 30 - Parks Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 30.17 - Fixed Bench - Surface Slope Clear space has a slope greater than 2% in some or all directions.(1999 ADAAG: 3% slope is allowed when necessary for drainage). 4.3.7 403.3 -1999 ADAAG- 16.12.7 2.4%.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 107 Entry Plaza 30.21 - Fixed Bench Size Accessible bench does not have seats that are 20" to 24" in depth and 42" min. in length. OR The back support does not extend from a point 2" maximum above the bench to 18" min. above the bench. -903.3 903.4 Fig. 903.4 --Back support extends 14" from seat, 7 1/2" above bench. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 109 Terrace 30.22 - Fixed Bench Armrest Less than 50% of the fixed benches required to be accessible have at least one armrest that can withstand 250 lbs. of force in any direction. 4.26.3 903.6 1115B.7 .2 1999 ADAAG- 16.12.2. 2; 16.12.8 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 110 Terrace 30.20 - Fixed Bench - Back Support Back support is not provided along the full length of the accessible bench. -903.4 -1999 ADAAG- 16.12.5 Back support does not extend the full length of the bench. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 111 Terrace 30.19 - Fixed Bench Height The height of the front edge of the seating surface is not between 17" and 19" above the adjacent grade or floor space. -903.5 -1999 ADAAG- 16.12.3 16" high.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 112 Terrace 30.13 - Number and Dispersal - Accessible Fixed Benches Less than 50% of the fixed benches being provided in an area are accessible. OR They are not dispersed among the types provided. ---1999 ADAAG- 16.12.2. 2; 16.12.2 2 benches, 0 accessible.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 113 Terrace 41Number of Key Notes for Group 30 - Parks: Page 47 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 02 - Passenger Loading Zone Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 02.10 - Sign There is no reflectorized sign stating “Passenger Loading Zone Only”, with the ISA in white on a blue background, adjacent to and visible from the accessible passenger loading zone. 4.1.2(7) (b) -1131B.2 item 1 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 46 Bus Drop-off 02.12B - Bus Stop Pad Slope Perpendicular to Roadway Bus stop pad slope perpendicular to the roadway exceeds 2%. 10.2.1 810.2.4 1121B.2 .1 2.8% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 47 Bus Drop-off 02.17 - Other - Passenger Loading Zones See Additional Comments ---Bench provided at bus drop-off, no wheelchair seating provided. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 48 Bus Drop-off 3Number of Key Notes for Group 02 - Passenger Loading Zone: Group 07 - Ramps Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 07.08 - Top Landing - Size Top landing is less than 60“ x 60”.4.8.4(1) 405.7.4 1133B.5 .4.2 -No top landing.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 88 Ramp 07.07A - Level Landings Landings at the top or bottom of each ramp or each ramp run is not level (slope is greater than 2% in some or all directions). 4.8.4 405.7; 405.7.1 1133B.5 .4.1 -5.7% RS at bottom landing.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 89 Ramp Page 48 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 07 - Ramps Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 07.16 - Handrails Slope of the ramp exceeds 5%, and handrails are not provided on each side. (Per CBC 1133B.5.5.1, at exterior door landings, handrails are not required on ramps less than 6” high or 72” long. Handrails are not required on curb ramps or adjacent to fixed seating in assembly areas.) 4.8.5 405.8; 505.2 1133B.5 .5.1 -None provided.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 90 Ramp 3Number of Key Notes for Group 07 - Ramps: Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.34 - Electrical/Commu nications Receptacles - Mounting Height Electrical/communications receptacle is not located between 15” min.. and 48” max.. AFF. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 308.2.1; Fig. 308.2.1; 308.3.1; Fig. 308.3.1; 309.3 1117B.6 (5.2) -8" high receptacle.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 116 Terrace 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -No single action hardware at display cabinets. PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 123 Lobby 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -Non-single action cabinet hardware. EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 131 Studio Page 49 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.36A - Counter Height Where provided in public or common use areas, countertops are not between 28" - 34” high. (Common use areas are those interior and exterior rooms, spaces, or elements that are made available for the use of a restricted group of people (for example, the occupants of an office building, or the guests of such occupants). 4.32.4 902.3 1122B.4 -EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 133 Studio 14.32B - Forward Reach Range over Obstruction - Controls Controls, dispensers, and similar devices over an obstruction are mounted higher than 44” AFF when the clear floor space allows only a forward approach and the horizontal reach limit is between 20" to 25". (Mounting height of 48" max.. AFF is permitted when the horizontal reach is less than 20".) 4.2.5; Fig. 5(b) 308.2.2; Fig. 308.2.2 1117B.6 (3); 1118.5; Fig. 11B-5C -46 3/4" high light switch over 31" deep counter. EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 134 Studio 14.32B - Forward Reach Range over Obstruction - Controls Controls, dispensers, and similar devices over an obstruction are mounted higher than 44” AFF when the clear floor space allows only a forward approach and the horizontal reach limit is between 20" to 25". (Mounting height of 48" max.. AFF is permitted when the horizontal reach is less than 20".) 4.2.5; Fig. 5(b) 308.2.2; Fig. 308.2.2 1117B.6 (3); 1118.5; Fig. 11B-5C -Data outlet 42 3/4" high over 31" deep counter. EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 135 Studio 14.36A - Counter Height Where provided in public or common use areas, countertops are not between 28" - 34” high. (Common use areas are those interior and exterior rooms, spaces, or elements that are made available for the use of a restricted group of people (for example, the occupants of an office building, or the guests of such occupants). 4.32.4 902.3 1122B.4 -35" high counter.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 145 Workroom Page 50 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.28 - Fixed/Built-in Seating, Tables or Counters At fixed or built-in seating, tables, or counters in public or common employee areas, less than 5% of the provided seating spaces are wheelchair accessible and have a 30” by 48” clear space which overlaps an accessible route of travel. (Wheelchair accessible seating spaces are between 28" - 34" high and with knee space measuring at least 27" high, 30" wide, and 19" deep.) (These elements include study carrels and student laboratory stations.) 4.1.3(18 ); 4.32.1; 4.32.4 226.1; Advisory 226.1; 305; 306; 902.2 1122B.1 -No knee space.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 146 Workroom 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -55" high Pencil sharpener.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 147 Workroom 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 148 Workroom 14.29A - Counter - Knee Space Height Where seating for persons in wheelchairs is provided at table or counter, knee space is less than 27” high. 4.32.3 306.3.1; Fig. 306.3 1122B.3 ; Fig. 11B-13 -23" to keyboard.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 154 Office Page 51 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Coat hook at 60 1/2" high.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 165 Library 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -Knob type hardware for cabinet. EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 179 Kitchen 14.36A - Counter Height Where provided in public or common use areas, countertops are not between 28" - 34” high. (Common use areas are those interior and exterior rooms, spaces, or elements that are made available for the use of a restricted group of people (for example, the occupants of an office building, or the guests of such occupants). 4.32.4 902.3 1122B.4 -37" high.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 180 Kitchen 14.32B - Forward Reach Range over Obstruction - Controls Controls, dispensers, and similar devices over an obstruction are mounted higher than 44” AFF when the clear floor space allows only a forward approach and the horizontal reach limit is between 20" to 25". (Mounting height of 48" max.. AFF is permitted when the horizontal reach is less than 20".) 4.2.5; Fig. 5(b) 308.2.2; Fig. 308.2.2 1117B.6 (3); 1118.5; Fig. 11B-5C -45" high receptacle over 25" deep counter. EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 181 Kitchen 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -Knob type hardware for kitchen cabinets. EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 192 Kitchen Page 52 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.32B - Forward Reach Range over Obstruction - Controls Controls, dispensers, and similar devices over an obstruction are mounted higher than 44” AFF when the clear floor space allows only a forward approach and the horizontal reach limit is between 20" to 25". (Mounting height of 48" max.. AFF is permitted when the horizontal reach is less than 20".) 4.2.5; Fig. 5(b) 308.2.2; Fig. 308.2.2 1117B.6 (3); 1118.5; Fig. 11B-5C -49" high receptacle over 21" deep counter. EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 193 Kitchen 14.36A - Counter Height Where provided in public or common use areas, countertops are not between 28" - 34” high. (Common use areas are those interior and exterior rooms, spaces, or elements that are made available for the use of a restricted group of people (for example, the occupants of an office building, or the guests of such occupants). 4.32.4 902.3 1122B.4 -35 3/4" high.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 194 Kitchen 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -Twist type lock at roll-up door.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 195 Kitchen 14.32B - Forward Reach Range over Obstruction - Controls Controls, dispensers, and similar devices over an obstruction are mounted higher than 44” AFF when the clear floor space allows only a forward approach and the horizontal reach limit is between 20" to 25". (Mounting height of 48" max.. AFF is permitted when the horizontal reach is less than 20".) 4.2.5; Fig. 5(b) 308.2.2; Fig. 308.2.2 1117B.6 (3); 1118.5; Fig. 11B-5C -38" high U-pull over 32" deep counter. EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 196 Kitchen 14.32B - Forward Reach Range over Obstruction - Controls Controls, dispensers, and similar devices over an obstruction are mounted higher than 44” AFF when the clear floor space allows only a forward approach and the horizontal reach limit is between 20" to 25". (Mounting height of 48" max.. AFF is permitted when the horizontal reach is less than 20".) 4.2.5; Fig. 5(b) 308.2.2; Fig. 308.2.2 1117B.6 (3); 1118.5; Fig. 11B-5C -Light switch at 46" high over 28" deep counter. EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 197 Kitchen Page 53 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.36A - Counter Height Where provided in public or common use areas, countertops are not between 28" - 34” high. (Common use areas are those interior and exterior rooms, spaces, or elements that are made available for the use of a restricted group of people (for example, the occupants of an office building, or the guests of such occupants). 4.32.4 902.3 1122B.4 -EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 198 Kitchen 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -Twist type controls.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 201 Kitchen 14.32B - Forward Reach Range over Obstruction - Controls Controls, dispensers, and similar devices over an obstruction are mounted higher than 44” AFF when the clear floor space allows only a forward approach and the horizontal reach limit is between 20" to 25". (Mounting height of 48" max.. AFF is permitted when the horizontal reach is less than 20".) 4.2.5; Fig. 5(b) 308.2.2; Fig. 308.2.2 1117B.6 (3); 1118.5; Fig. 11B-5C -48" high receptacle over 21" deep counter. EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 202 Kitchen 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -Knob type hardware for cabinets. EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 204 Dishwashing Area 14.36B - Kitchen Counter/Sink Height Where provided in public or common use areas, countertops and sinks are not mounted at 34” AFF. max..(Common use areas are those interior and exterior rooms, spaces, or elements that are made available for the use of a restricted group of people (for example, the occupants of an office building, or the guests of such occupants). 4.24.2 212.3; 606.3 1115B.4 .7(2); 1122B.4 -37" high.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 205 Dishwashing Area Page 54 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.37 - Kitchen Sink Sink does not provide accessible knee clearance (i.e. at least 27” high, 30” wide, and 19” deep). 4.24.3 305; 306; 606.2 1115B.4 .7(2); 1122B.4 -No knee space.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 206 Dishwashing Area 14.37 - Kitchen Sink Sink does not provide accessible knee clearance (i.e. at least 27” high, 30” wide, and 19” deep). 4.24.3 305; 306; 606.2 1115B.4 .7(2); 1122B.4 -14 1/2" knee height, 3" knee depth. PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 218 Multipurpose Room 14.32B - Forward Reach Range over Obstruction - Controls Controls, dispensers, and similar devices over an obstruction are mounted higher than 44” AFF when the clear floor space allows only a forward approach and the horizontal reach limit is between 20" to 25". (Mounting height of 48" max.. AFF is permitted when the horizontal reach is less than 20".) 4.2.5; Fig. 5(b) 308.2.2; Fig. 308.2.2 1117B.6 (3); 1118.5; Fig. 11B-5C -48" high receptacle over 23" deep counter. PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 219 Multipurpose Room 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -Knob hardware for cabinet.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 240 Multipurpose Room 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -No hardware for display cabinet. PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 241 Multipurpose Room 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 242 Multipurpose Room Page 55 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -Non-compliant cabinet hardware. MS - Maintenance and Storage Only C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 271 Janitor Closet 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -16" protruding shelf at 59" high. MS - Maintenance and Storage Only A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 272 Janitor Closet 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -Non-compliant cabinet hardware. EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 287 Staff Restroom 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -First Aid Kit at 66" high.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 294 Staff Restroom 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Key box at 70" high.MS - Maintenance and Storage Only C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 299 Storage Room Page 56 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -coat hook at 70" high.MS - Maintenance and Storage Only C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 302 Storage Room 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Key pad at 56 1/2" high.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 304 Reception Desk 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -Knob type controls for display cabinets. PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 309 Exhibit Room 14.36A - Counter Height Where provided in public or common use areas, countertops are not between 28" - 34” high. (Common use areas are those interior and exterior rooms, spaces, or elements that are made available for the use of a restricted group of people (for example, the occupants of an office building, or the guests of such occupants). 4.32.4 902.3 1122B.4 -40 1/4" high.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 311 Exhibit Room 14.50 - Other - Rooms and Spaces See Additional Comments ----PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 317 Exhibit Room Page 57 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.30A - Wall- Mounted Protruding Objects Wall-mounted object(s) with leading edges between 27 and 80” from the floor project more than 4" into the pathway. (Wall mounted objects with leading edges at or below 27” may project any amount as long as the required clear width of an accessible route is not reduced.) 4.4.1 307.2; Fig. 307.2 1133B.8 .6.1 -TPD protrudes 5 1/2" from wall at 29" high. PV - Public/Visitor Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 335 Men's Restroom 14.30A - Wall- Mounted Protruding Objects Wall-mounted object(s) with leading edges between 27 and 80” from the floor project more than 4" into the pathway. (Wall mounted objects with leading edges at or below 27” may project any amount as long as the required clear width of an accessible route is not reduced.) 4.4.1 307.2; Fig. 307.2 1133B.8 .6.1 -FND protrudes 5 1/2" at 35" high. PV - Public/Visitor Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 359 Women's Restroom 14.30A - Wall- Mounted Protruding Objects Wall-mounted object(s) with leading edges between 27 and 80” from the floor project more than 4" into the pathway. (Wall mounted objects with leading edges at or below 27” may project any amount as long as the required clear width of an accessible route is not reduced.) 4.4.1 307.2; Fig. 307.2 1133B.8 .6.1 -Hand dryer protrudes 7 1/2" at 39" high. PV - Public/Visitor Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 360 Women's Restroom 14.30A - Wall- Mounted Protruding Objects Wall-mounted object(s) with leading edges between 27 and 80” from the floor project more than 4" into the pathway. (Wall mounted objects with leading edges at or below 27” may project any amount as long as the required clear width of an accessible route is not reduced.) 4.4.1 307.2; Fig. 307.2 1133B.8 .6.1 -TPD protrudes 5 1/2" at 12" high. PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 378 Women's Restroom 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -Not single action at display.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 379 Entry Plaza Page 58 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -65" to hardware.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 380 Entry Plaza 48Number of Key Notes for Group 14 - Rooms and Spaces: Group 08 - Stairs Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 08.07A - Continuous Handrails Continuous handrails are not provided along both sides. 4.9.4 504.6; 505.2 1133B.4 .1.1 -None provided.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 3 Vista Point 08.05A - Exterior Stairs - Color Strip Contrasting color strips have not been provided. --1133B.4 .4 -None provided.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 4 Vista Point 08.07A - Continuous Handrails Continuous handrails are not provided along both sides. 4.9.4 504.6; 505.2 1133B.4 .1.1 -None provided.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 26 Vista Point 08.05A - Exterior Stairs - Color Strip Contrasting color strips have not been provided. --1133B.4 .4 -None provided.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 27 Vista Point Page 59 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 08 - Stairs Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 08.03D - Level Landing Landing is not level (slope is greater than 2% in some or all directions). --1009.5. 1 -2.5% CS & 5.4% RS at bottom landing. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 28 Vista Point 08.09B - Handrail Extensions - Bottom Landing At ends of handrails, less than 12” plus the tread width extends beyond the bottom nosing. (Top and bottom handrail extensions are important safety features for persons with balance problems and must extend in the direction of the stair run to permit the intended use.) (Per ADA/CBC Standards, in existing buildings and facilities, full extension of handrails at stairs shall not be required in alterations where such extensions would be hazardous or impossible due to plan configuration.) 4.9.4(2) 505.10; 505.10. 3; Fig. 505.10. 3 1133B.4 .2.2 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 76 Stairs 08.09A - Handrail Extensions - Top Landing At ends of handrails, less than 12” of handrail extends beyond the top nosing. (Top and bottom handrail extensions are important safety features for persons with balance problems and must extend in the direction of the stair run to permit the intended use.) (Per ADA/CBC Standards, in existing buildings and facilities, full extension of handrails at stairs shall not be required in alterations where such extensions would be hazardous or impossible due to plan configuration.) 4.9.4(2) 505.10; 505.10. 2; Fig. 505.10. 2 1133B.4 .2.2 -6" top extensions.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 77 Stairs 08.09D - Handrail Extension - Sloping versus Bottom Landing At the bottom, the handrail extension does not continue to slope for a distance of the width of one tread from the bottom riser. OR The remainder of the extension is not horizontal. 4.9.4(2) 505.10. 3 1133B.4 .2.2 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 78 Stairs Page 60 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 08 - Stairs Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 08.09C - Handrail Extension - Parallel with Top Landing At the top, the handrail extension is not parallel to the floor or ground surface. 4.9.4(2) 505.10. 2 1133B.4 .2.2 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 79 Stairs 08.02B - Riser Height The risers are not uniform. OR The risers are not between 4” and 7” in height. 4.9.2 504.2 1009.3; 1133B.4 .5.3 -Risers not uniform, 6" to 7 3/8". PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 80 Stairs 08.03A - Tread Depth The treads are not uniform. OR The treads are less than 11” deep measured from riser to riser. 4.9.2 504.2 1009.3; 1133B.4 .5.3 -Tread not uniform, 11 1/2" to 12". PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 81 Stairs 11Number of Key Notes for Group 08 - Stairs: Group 06 - Telephones Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 06.02B - ISA Sign The wheelchair accessible telephone is not identified by the ISA. 4.1.3(17 )(b); 4.30.7(1 ) 703.2.1; Fig. 703.2.1 1117B.5 .8.1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 99 Entry Plaza 06.08 - Wall- Mounted Protruding Objects Wall-mounted telephone(s) with leading edges between 27" and 80” from the floor projects more than 4" into the circulation path. (Wall mounted telephones or their enclosures with leading edges at or below 27” may project any amount as long as the required clear width of an accessible route is not reduced.) 4.31.4; 4.4.1 204; 307.2; Advisory 307.2; Fig. 307.2 1133B.8 .6.1 -Telephone protrudes 12 1/2" at 30" high. PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 100 Entry Plaza 2Number of Key Notes for Group 06 - Telephones: Page 61 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.78 - Pipe Insulation at Lavatory Drainpipes and hot water pipes are not insulated to protect against contact. 4.19.4 606.5 1115B.4 .3(4) -EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 199 Kitchen 16.84A - Paper Towel Dispenser - Operating Height Mounting height of paper towel dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one paper towel dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one paper towel dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 200 Kitchen 16.21A - Raised Characters and Braille (Visual/Tactile Signs) The raised characters on this sign are not accompanied by California Grade 2 Braille (i.e., the dots within each cell are domed and spaced 1/10” o.c.) 4.30.4 703.2; 703.3 1117B.5 .5 item 1, 1117B.5 .6 -Bad Braille.PV - Public/Visitor Use D - Minor Code Deviation 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 256 Men's Restroom 16.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -10 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 257 Men's Restroom 16.08A - Door Swing The door swing intrudes into the clear floor space of one or more fixtures. 4.22.2 603.2.3; Advisory 603.2.3 1115B.3 .1 item 2; 1115B.3 .2 item 2; 1115B.5 -Door swings into PTD clear floor space. PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 259 Men's Restroom Page 62 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.27B - Unobstructed Access to Accessible Stalls Clear, unobstructed access at least 44" wide is not provided to accessible water closet compartment(s). 4.17.3; Fig 30(a) 604.8.1. 2; Fig. 604.8.1. 2 1115B.3 .1(4.5) -42" wide.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 260 Men's Restroom 16.84C - Soap Dispenser - Operating Height Mounting height of soap dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one soap dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one soap dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -41 1/2" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 261 Men's Restroom 16.82A - Mirror Height - Max. 40" AFF Standard Mirror above accessible lavatory or countertop is mounted so the bottom edge of the reflective surface is not 40” max.. AFF. (ADA Standards require at least one mirror to be accessible; CBC Standards prior to August 1, 2009 required all mirrors to be accessible. Effective August 1, 2009, amended CBC Standards require all mirrors above accessible lavatories or countertops to be accessible.) 4.19.6; Fig. 31 213.3.5; 603.3; Advisory 603.3 1115B.8 .1 -40 1/2" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 262 Men's Restroom 16.34 - Strike Side Clearance at Stall Door Where the stall door opens out at the end of an aisle, there is less than 18” of maneuvering space at the latch side of the stall door. 4.17.5; 4.13.6; Fig. 25 404.2.4. 1; Tab.404 .2.4.1; Fig.404. 2.4.1 1133B.2 .4.3; Figs. 11B-26B -1/2" strike clearance on pull side. PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 263 Men's Restroom 16.83 - Coat Hook - Height Where a coat hook is provided In an accessible stall, height of coat hook exceeds 48” AFF. 4.2.5 213.3.7; 308; 603.4 1117B.8 -61" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 264 Men's Restroom Page 63 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.50 - TP Dispenser - Location - Pre- 2007 CBC Facility Location of the toilet paper dispenser does not comply with the Standard in effect at the time of construction. (The 2001 CBC required toilet tissue dispensers located on the wall within 12" of the front edge of the toilet seat, measured to the centerline of the dispenser; mounted below the grab bar; and centered at a min. height of 19" AFF.) 4.16.6; Fig. 29(b) 604.7; Advisory 604.7; Fig. 604.7 --TPD 14" from water closet.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 265 Men's Restroom 16.21A - Raised Characters and Braille (Visual/Tactile Signs) The raised characters on this sign are not accompanied by California Grade 2 Braille (i.e., the dots within each cell are domed and spaced 1/10” o.c.) 4.30.4 703.2; 703.3 1117B.5 .5 item 1, 1117B.5 .6 -Bad Braille.PV - Public/Visitor Use D - Minor Code Deviation 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 273 Women's Restroom 16.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -7 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 274 Women's Restroom 16.84C - Soap Dispenser - Operating Height Mounting height of soap dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one soap dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one soap dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -41" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 276 Women's Restroom Page 64 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.82A - Mirror Height - Max. 40" AFF Standard Mirror above accessible lavatory or countertop is mounted so the bottom edge of the reflective surface is not 40” max.. AFF. (ADA Standards require at least one mirror to be accessible; CBC Standards prior to August 1, 2009 required all mirrors to be accessible. Effective August 1, 2009, amended CBC Standards require all mirrors above accessible lavatories or countertops to be accessible.) 4.19.6; Fig. 31 213.3.5; 603.3; Advisory 603.3 1115B.8 .1 -41" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 277 Women's Restroom 16.83 - Coat Hook - Height Where a coat hook is provided In an accessible stall, height of coat hook exceeds 48” AFF. 4.2.5 213.3.7; 308; 603.4 1117B.8 -61" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 278 Women's Restroom 16.47A - WC Location from Sidewall The centerline of the WC is not 18” absolute from a wall or partition. 4.22.4 -1115B.4 .1(1) -18 1/4" from side wall.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 279 Women's Restroom 16.50 - TP Dispenser - Location - Pre- 2007 CBC Facility Location of the toilet paper dispenser does not comply with the Standard in effect at the time of construction. (The 2001 CBC required toilet tissue dispensers located on the wall within 12" of the front edge of the toilet seat, measured to the centerline of the dispenser; mounted below the grab bar; and centered at a min. height of 19" AFF.) 4.16.6; Fig. 29(b) 604.7; Advisory 604.7; Fig. 604.7 --PTD 14" from water closet.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 280 Women's Restroom 16.85A - Clear Floor Space at Dispensers There is no clear floor space at least 30” x 48” in front of the dispenser to allow either a forward or a parallel approach to the dispenser. (Where provided, at least one dispenser of each type shall be accessible.) 4.27.2; 4.2.4 305.3 1117B.6 (2); 1118B.4 -28" wide clear floor space at hand dryer. PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 281 Women's Restroom Page 65 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.27B - Unobstructed Access to Accessible Stalls Clear, unobstructed access at least 44" wide is not provided to accessible water closet compartment(s). 4.17.3; Fig 30(a) 604.8.1. 2; Fig. 604.8.1. 2 1115B.3 .1(4.5) -42 1/2" wide.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 282 Women's Restroom 16.85A - Clear Floor Space at Dispensers There is no clear floor space at least 30” x 48” in front of the dispenser to allow either a forward or a parallel approach to the dispenser. (Where provided, at least one dispenser of each type shall be accessible.) 4.27.2; 4.2.4 305.3 1117B.6 (2); 1118B.4 -28" deep clear floor space at PTD. PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 283 Women's Restroom 16.15A - Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.30.1 216.2; 703.1; 703.2; 703.5 1117B.5 .1(1) -EC - Employee Common Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 284 Staff Restroom 16.83 - Coat Hook - Height Where a coat hook is provided In an accessible stall, height of coat hook exceeds 48” AFF. 4.2.5 213.3.7; 308; 603.4 1117B.8 -69" high.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 285 Staff Restroom 16.88 - Other - Toilet Facilities See Additional Comments ----Headroom clearance 74" to upper cabinets. EC - Employee Common Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 286 Staff Restroom 16.47A - WC Location from Sidewall The centerline of the WC is not 18” absolute from a wall or partition. 4.22.4 -1115B.4 .1(1) -20" from side wall.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 288 Staff Restroom 16.85A - Clear Floor Space at Dispensers There is no clear floor space at least 30” x 48” in front of the dispenser to allow either a forward or a parallel approach to the dispenser. (Where provided, at least one dispenser of each type shall be accessible.) 4.27.2; 4.2.4 305.3 1117B.6 (2); 1118B.4 -Clear floor space at SCD obstructed by non-fixed furniture. EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 289 Staff Restroom Page 66 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.55A - Side Grab Bar Height Side grab bar is not centered at 33" AFF. (ADA Standards require side grab bars to be centered from 33" to 36" AFF; CBC Standards require side grab bars to be centered at 33" AFF.) 4.17.6; Figs. 29 & 30 604.5; Advisory 604.5; 604.5.2; Fig. 604.5.2; 609.4 1115B.4 .1(3.1); Fig. 11B-1A -33 1/2" high.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 290 Staff Restroom 16.82A - Mirror Height - Max. 40" AFF Standard Mirror above accessible lavatory or countertop is mounted so the bottom edge of the reflective surface is not 40” max.. AFF. (ADA Standards require at least one mirror to be accessible; CBC Standards prior to August 1, 2009 required all mirrors to be accessible. Effective August 1, 2009, amended CBC Standards require all mirrors above accessible lavatories or countertops to be accessible.) 4.19.6; Fig. 31 213.3.5; 603.3; Advisory 603.3 1115B.8 .1 -40 1/2" high.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 292 Staff Restroom 16.78 - Pipe Insulation at Lavatory Drainpipes and hot water pipes are not insulated to protect against contact. 4.19.4 606.5 1115B.4 .3(4) -EC - Employee Common Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 293 Staff Restroom 16.88 - Other - Toilet Facilities See Additional Comments ----No clear floor space at First Aid Kit. EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 295 Staff Restroom 16.55B - Back Grab Bar Height - Non- Tank-Type WC At non-tank-type WC, back grab bar is not centered at 33" AFF. (ADA Standards require back grab bars to be centered from 33" to 36" AFF; CBC Standards require back grab bars to be centered at 33" AFF.) 4.17.6; Figs. 29 & 30 604.5; Advisory 604.5; 609.4 1115B.4 .1(3.2); Fig. 11B-1A -33 1/2" high.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 296 Staff Restroom Page 67 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.12 - Other Door Requirements Door does not comply with all applicable ADAAG and CBC accessibility requirements. 4.13 404.1; Advisory 404.1 1133B.2 -2.2% - 3.0% slope at door landing. PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 320 Men's Restroom 16.88 - Other - Toilet Facilities See Additional Comments ----Door stop.PV - Public/Visitor Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 321 Men's Restroom 16.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -10 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 322 Men's Restroom 16.15A - Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.30.1 216.2; 703.1; 703.2; 703.5 1117B.5 .1(1) -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 323 Men's Restroom 16.88 - Other - Toilet Facilities See Additional Comments ----2.03 seconds.PV - Public/Visitor Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 324 Men's Restroom 16.14A - Mounting Height - Geometric Symbol Signage The geometric symbol is not centered on the door leaf. OR The symbol is not mounted at a height of 60” AFF. --1115B.6 -59" high.PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 325 Men's Restroom 16.18A - ISA Accessible toilet room is not identified by an ISA. 4.1.3(16 )(b) 216.8 1117B.5 .1(3) -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 326 Men's Restroom Page 68 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.84A - Paper Towel Dispenser - Operating Height Mounting height of paper towel dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one paper towel dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one paper towel dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -42 1/2" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 328 Men's Restroom 16.84C - Soap Dispenser - Operating Height Mounting height of soap dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one soap dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one soap dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -46" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 329 Men's Restroom 16.82A - Mirror Height - Max. 40" AFF Standard Mirror above accessible lavatory or countertop is mounted so the bottom edge of the reflective surface is not 40” max.. AFF. (ADA Standards require at least one mirror to be accessible; CBC Standards prior to August 1, 2009 required all mirrors to be accessible. Effective August 1, 2009, amended CBC Standards require all mirrors above accessible lavatories or countertops to be accessible.) 4.19.6; Fig. 31 213.3.5; 603.3; Advisory 603.3 1115B.8 .1 -48 3/4" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 330 Men's Restroom 16.76 - Lavatory - Clearance near Sidewall The centerline of the lavatory is not 18” min.. from the nearest sidewall or partition. --1115B.4 .3(2); Fig 11B- 1D -16 1/2" from side wall.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 331 Men's Restroom Page 69 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.78 - Pipe Insulation at Lavatory Drainpipes and hot water pipes are not insulated to protect against contact. 4.19.4 606.5 1115B.4 .3(4) -PV - Public/Visitor Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 332 Men's Restroom 16.79 - Smooth Surfaces at Lavatory The area below the lavatory is not free of sharp or abrasive surfaces. 4.19.4 606.5 1115B.4 .3(4) -PV - Public/Visitor Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 333 Men's Restroom 16.50 - TP Dispenser - Location - Pre- 2007 CBC Facility Location of the toilet paper dispenser does not comply with the Standard in effect at the time of construction. (The 2001 CBC required toilet tissue dispensers located on the wall within 12" of the front edge of the toilet seat, measured to the centerline of the dispenser; mounted below the grab bar; and centered at a min. height of 19" AFF.) 4.16.6; Fig. 29(b) 604.7; Advisory 604.7; Fig. 604.7 --18" from water closet.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 334 Men's Restroom 16.53 - SC Dispenser Height Mounting height of seat cover dispenser's highest operable part exceeds 40" AFF. 4.22.7; 4.27.3; 4.2.5; 4.2.6 -1115B.8 .3 -48" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 336 Men's Restroom 16.85A - Clear Floor Space at Dispensers There is no clear floor space at least 30” x 48” in front of the dispenser to allow either a forward or a parallel approach to the dispenser. (Where provided, at least one dispenser of each type shall be accessible.) 4.27.2; 4.2.4 305.3 1117B.6 (2); 1118B.4 -SCD above water closet.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 337 Men's Restroom 16.48 - WC Seat Height The top of the WC seat is not between 17” and 19” AFF. 4.16.3; Fig. 29(b) 604.4 1115B.4 .1(4); Fig. 11B-1A -19 1/2" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 338 Men's Restroom Page 70 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.54A - Grab Bar Grab bar is not provided.4.17.6; Figs. 29 & 30 604.5; Advisory 604.5; 609.4 1115B.4 .1(3.1) & (3.2); Fig. 11B-1A -None provided.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 339 Men's Restroom 16.65B - Wall- Hung Urinal - Rim Height Height of wall-hung urinal's rim exceeds 17” AFF. 4.18.2 605.2; Fig. 605.2(a) 1115B.4 .2(1) -17 1/2" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 340 Men's Restroom 16.08A - Door Swing The door swing intrudes into the clear floor space of one or more fixtures. 4.22.2 603.2.3; Advisory 603.2.3 1115B.3 .1 item 2; 1115B.3 .2 item 2; 1115B.5 -Door swings into water closet clear floor space. PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 341 Men's Restroom 16.88 - Other - Toilet Facilities See Additional Comments ----Door stop.PV - Public/Visitor Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 353 Women's Restroom 16.88 - Other - Toilet Facilities See Additional Comments ----3/4" threshold.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 354 Women's Restroom 16.15A - Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.30.1 216.2; 703.1; 703.2; 703.5 1117B.5 .1(1) -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 355 Women's Restroom Page 71 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.18A - ISA Accessible toilet room is not identified by an ISA. 4.1.3(16 )(b) 216.8 1117B.5 .1(3) -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 356 Women's Restroom 16.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -9 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 357 Women's Restroom 16.84C - Soap Dispenser - Operating Height Mounting height of soap dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one soap dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one soap dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -43" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 361 Women's Restroom 16.82A - Mirror Height - Max. 40" AFF Standard Mirror above accessible lavatory or countertop is mounted so the bottom edge of the reflective surface is not 40” max.. AFF. (ADA Standards require at least one mirror to be accessible; CBC Standards prior to August 1, 2009 required all mirrors to be accessible. Effective August 1, 2009, amended CBC Standards require all mirrors above accessible lavatories or countertops to be accessible.) 4.19.6; Fig. 31 213.3.5; 603.3; Advisory 603.3 1115B.8 .1 -43 3/4" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 362 Women's Restroom 16.76 - Lavatory - Clearance near Sidewall The centerline of the lavatory is not 18” min.. from the nearest sidewall or partition. --1115B.4 .3(2); Fig 11B- 1D -17 1/8" from side wall.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 363 Women's Restroom Page 72 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.32A - U- Pulls at Stall Door The stall door does not have U-pulls on both sides. 4.13.9; 4.17.5 309.4; 404.27; 604.8.1. 2 1115B.3 .1(4.4) -U-pulls not on both sides.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 364 Women's Restroom 16.33 - Self- Closing Stall Door The stall door is not self-closing.4.13.10 604.8.1. 2 1115B.3 .1(4.4) -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 365 Women's Restroom 16.83 - Coat Hook - Height Where a coat hook is provided In an accessible stall, height of coat hook exceeds 48” AFF. 4.2.5 213.3.7; 308; 603.4 1117B.8 -60 1/2" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 366 Women's Restroom 16.84F - Diaper Changing Table - Operating Height Mounting height of diaper changing table's highest operable part exceeds 40" AFF. (Where provided, at least one shall be accessible.) 4.27.3 308; 309 --52" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 367 Women's Restroom 16.84G - Diaper Changing Table - Table Surface Height Height of diaper changing table surface is not between 28" to 34” AFF. (Where provided, at least one shall be accessible.) 4.1.3(18 ), 4.32.4 308; 309 1122B.1 , 1122B.4 -35 1/2" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 368 Women's Restroom 16.36A - Stall Width The stall is less than 60” wide.4.17.3; Fig. 30(a) 604.8.1. 1; Advisory 604.8.1. 1; Fig. 604.8.1. 1 1115B.3 .1(4.1) -57" wide.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 369 Women's Restroom Page 73 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.53 - SC Dispenser Height Mounting height of seat cover dispenser's highest operable part exceeds 40" AFF. 4.22.7; 4.27.3; 4.2.5; 4.2.6 -1115B.8 .3 -52" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 370 Women's Restroom 16.50 - TP Dispenser - Location - Pre- 2007 CBC Facility Location of the toilet paper dispenser does not comply with the Standard in effect at the time of construction. (The 2001 CBC required toilet tissue dispensers located on the wall within 12" of the front edge of the toilet seat, measured to the centerline of the dispenser; mounted below the grab bar; and centered at a min. height of 19" AFF.) 4.16.6; Fig. 29(b) 604.7; Advisory 604.7; Fig. 604.7 --TPD 24" from WC, and 12" above floor. PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 371 Women's Restroom 16.56 - Grab Bar Wall Clearance The space between the grab bar and the wall is not 1-1/2” absolute. 4.17.6, 4.26.2; Fig. 39 609.3 1115B.7 .1; Fig. 11B-1C -1 3/4".PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 372 Women's Restroom 16.57 - Grab Bar Clearance Dispenser is located so that it obstructs the use of the grab bar, i.e. less than 18” above or within 1-1/2” below the tangent point of the grab bar. (Exception: When dispenser is recessed, flush with wall, and has no sharp edges.) 4.17.6, 4.26.2; Fig. 39 609.4 --10" to SCD, 0" to TPD.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 373 Women's Restroom 16.55A - Side Grab Bar Height Side grab bar is not centered at 33" AFF. (ADA Standards require side grab bars to be centered from 33" to 36" AFF; CBC Standards require side grab bars to be centered at 33" AFF.) 4.17.6; Figs. 29 & 30 604.5; Advisory 604.5; 604.5.2; Fig. 604.5.2; 609.4 1115B.4 .1(3.1); Fig. 11B-1A -35" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 374 Women's Restroom Page 74 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC) Reporting: 380 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.55B - Back Grab Bar Height - Non- Tank-Type WC At non-tank-type WC, back grab bar is not centered at 33" AFF. (ADA Standards require back grab bars to be centered from 33" to 36" AFF; CBC Standards require back grab bars to be centered at 33" AFF.) 4.17.6; Figs. 29 & 30 604.5; Advisory 604.5; 609.4 1115B.4 .1(3.2); Fig. 11B-1A -35" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 375 Women's Restroom 16.26A - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -3.5% to 5.1% at floor drain.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 376 Women's Restroom 16.84A - Paper Towel Dispenser - Operating Height Mounting height of paper towel dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one paper towel dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one paper towel dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -42 1/2" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 377 Women's Restroom 73Number of Key Notes for Group 16 - Toilet Facilities: 380Number of Key Notes for Facility 09 - Lower Point Vicente Park & Point Vicente Interpretive Center (PVIC): 380Total Number of Key Notes for All Groups: Page 75 of 75 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA