Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Ladera Linda Park - Community Center_ComplianceReport_20130509-114631
Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 20 - Alarms Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 20.16B - Surface-Mounted Fire Extinguisher - Mounting Height Where fire extinguishers are surface-mounted, mounting height of the extinguisher is not compliant. (Compliant surface-mounted extinguisher is 48” AFF maximum, as measured to the highest operable part, or in existing buildings, when the extinguisher is 54” AFF and parallel approach is provided) 4.27.3 308.2.1; Fig. 308.2.1; 308.3.1; Fig. 308.3.1 1118B.4 (1); 1118B.5 ; 1118B.6 -58" high.PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 225 Classroom G 20.04 - Common Use Areas - Visual Alarms Visual alarms are not provided in common use area(s) of the building such as meeting and conference rooms, open office space, classrooms, cafeterias, filing and photocopy rooms, employee break rooms, dressing, examination, and treatment rooms, and similar spaces that are not used solely as employee work areas. 4.28.1 215.2; 702.1 907.9.1. 1 -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 226 Classroom G 20.04 - Common Use Areas - Visual Alarms Visual alarms are not provided in common use area(s) of the building such as meeting and conference rooms, open office space, classrooms, cafeterias, filing and photocopy rooms, employee break rooms, dressing, examination, and treatment rooms, and similar spaces that are not used solely as employee work areas. 4.28.1 215.2; 702.1 907.9.1. 1 -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 250 Classroom H 20.16B - Surface-Mounted Fire Extinguisher - Mounting Height Where fire extinguishers are surface-mounted, mounting height of the extinguisher is not compliant. (Compliant surface-mounted extinguisher is 48” AFF maximum, as measured to the highest operable part, or in existing buildings, when the extinguisher is 54” AFF and parallel approach is provided) 4.27.3 308.2.1; Fig. 308.2.1; 308.3.1; Fig. 308.3.1 1118B.4 (1); 1118B.5 ; 1118B.6 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 269 Classroom Page 1 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 20 - Alarms Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 20.04 - Common Use Areas - Visual Alarms Visual alarms are not provided in common use area(s) of the building such as meeting and conference rooms, open office space, classrooms, cafeterias, filing and photocopy rooms, employee break rooms, dressing, examination, and treatment rooms, and similar spaces that are not used solely as employee work areas. 4.28.1 215.2; 702.1 907.9.1. 1 -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 272 Classroom 20.04 - Common Use Areas - Visual Alarms Visual alarms are not provided in common use area(s) of the building such as meeting and conference rooms, open office space, classrooms, cafeterias, filing and photocopy rooms, employee break rooms, dressing, examination, and treatment rooms, and similar spaces that are not used solely as employee work areas. 4.28.1 215.2; 702.1 907.9.1. 1 -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 298 Classroom K 20.04 - Common Use Areas - Visual Alarms Visual alarms are not provided in common use area(s) of the building such as meeting and conference rooms, open office space, classrooms, cafeterias, filing and photocopy rooms, employee break rooms, dressing, examination, and treatment rooms, and similar spaces that are not used solely as employee work areas. 4.28.1 215.2; 702.1 907.9.1. 1 -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 331 Classroom J 20.04 - Common Use Areas - Visual Alarms Visual alarms are not provided in common use area(s) of the building such as meeting and conference rooms, open office space, classrooms, cafeterias, filing and photocopy rooms, employee break rooms, dressing, examination, and treatment rooms, and similar spaces that are not used solely as employee work areas. 4.28.1 215.2; 702.1 907.9.1. 1 -GS - General Student Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 351 Montessori Classroom Page 2 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 20 - Alarms Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 20.04 - Common Use Areas - Visual Alarms Visual alarms are not provided in common use area(s) of the building such as meeting and conference rooms, open office space, classrooms, cafeterias, filing and photocopy rooms, employee break rooms, dressing, examination, and treatment rooms, and similar spaces that are not used solely as employee work areas. 4.28.1 215.2; 702.1 907.9.1. 1 -GS - General Student Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 389 Classroom F 20.16B - Surface-Mounted Fire Extinguisher - Mounting Height Where fire extinguishers are surface-mounted, mounting height of the extinguisher is not compliant. (Compliant surface-mounted extinguisher is 48” AFF maximum, as measured to the highest operable part, or in existing buildings, when the extinguisher is 54” AFF and parallel approach is provided) 4.27.3 308.2.1; Fig. 308.2.1; 308.3.1; Fig. 308.3.1 1118B.4 (1); 1118B.5 ; 1118B.6 -64" high.GS - General Student Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 416 Classroom E 20.04 - Common Use Areas - Visual Alarms Visual alarms are not provided in common use area(s) of the building such as meeting and conference rooms, open office space, classrooms, cafeterias, filing and photocopy rooms, employee break rooms, dressing, examination, and treatment rooms, and similar spaces that are not used solely as employee work areas. 4.28.1 215.2; 702.1 907.9.1. 1 -GS - General Student Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 418 Classroom E 20.02 - Toilet, Bathroom, or Shower Room - Visual Alarms Visual alarms are not provided at public or common use toilet, bathroom, or shower room. 4.28.1 215.1; Advisory 215.1; 702.1 907.9.1. 1 -GS - General Student Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 439 Classroom E - Restrooms Page 3 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 20 - Alarms Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 20.16B - Surface-Mounted Fire Extinguisher - Mounting Height Where fire extinguishers are surface-mounted, mounting height of the extinguisher is not compliant. (Compliant surface-mounted extinguisher is 48” AFF maximum, as measured to the highest operable part, or in existing buildings, when the extinguisher is 54” AFF and parallel approach is provided) 4.27.3 308.2.1; Fig. 308.2.1; 308.3.1; Fig. 308.3.1 1118B.4 (1); 1118B.5 ; 1118B.6 -54" high.PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 442 Office 20.04 - Common Use Areas - Visual Alarms Visual alarms are not provided in common use area(s) of the building such as meeting and conference rooms, open office space, classrooms, cafeterias, filing and photocopy rooms, employee break rooms, dressing, examination, and treatment rooms, and similar spaces that are not used solely as employee work areas. 4.28.1 215.2; 702.1 907.9.1. 1 -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 447 Office 20.02 - Toilet, Bathroom, or Shower Room - Visual Alarms Visual alarms are not provided at public or common use toilet, bathroom, or shower room. 4.28.1 215.1; Advisory 215.1; 702.1 907.9.1. 1 -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 503 Men's Restroom 20.02 - Toilet, Bathroom, or Shower Room - Visual Alarms Visual alarms are not provided at public or common use toilet, bathroom, or shower room. 4.28.1 215.1; Advisory 215.1; 702.1 907.9.1. 1 -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 545 Women's Restroom 20.04 - Common Use Areas - Visual Alarms Visual alarms are not provided in common use area(s) of the building such as meeting and conference rooms, open office space, classrooms, cafeterias, filing and photocopy rooms, employee break rooms, dressing, examination, and treatment rooms, and similar spaces that are not used solely as employee work areas. 4.28.1 215.2; 702.1 907.9.1. 1 -GS - General Student Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 594 Classroom A Page 4 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 20 - Alarms Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 20.16B - Surface-Mounted Fire Extinguisher - Mounting Height Where fire extinguishers are surface-mounted, mounting height of the extinguisher is not compliant. (Compliant surface-mounted extinguisher is 48” AFF maximum, as measured to the highest operable part, or in existing buildings, when the extinguisher is 54” AFF and parallel approach is provided) 4.27.3 308.2.1; Fig. 308.2.1; 308.3.1; Fig. 308.3.1 1118B.4 (1); 1118B.5 ; 1118B.6 -66" high.GS - General Student Use B - Severe or Complete Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 601 Classroom A 20.15 - Alarm Initiating Devices - Operation Operating hardware of the pull station is not accessible (i.e.: it requires tight grasping, pinching, or twisting of the wrist, or requires a force exceeding 5 lbs.) 4.27.4 309.4 907.3.2, 1117B.6 (4) -GS - General Student Use B - Severe or Complete Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 603 Classroom A 20.14 - Alarm Initiating Devices - Mounting Height Height of manual alarm pull station is not compliant. (Compliant devices are mounted 42” min. to 48” maximum, as measured to highest point of the activating handle or lever, or in existing buildings, the initiating device is 54” AFF and parallel approach is provided.) 4.27.3 308.2.1; Fig. 308.2.1; 308.3.1; Fig. 308.3.1 907.3.2 -59" high.GS - General Student Use B - Severe or Complete Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 604 Classroom A 20.02 - Toilet, Bathroom, or Shower Room - Visual Alarms Visual alarms are not provided at public or common use toilet, bathroom, or shower room. 4.28.1 215.1; Advisory 215.1; 702.1 907.9.1. 1 -GS - General Student Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 612 Classroom A - Restroom 20.02 - Toilet, Bathroom, or Shower Room - Visual Alarms Visual alarms are not provided at public or common use toilet, bathroom, or shower room. 4.28.1 215.1; Advisory 215.1; 702.1 907.9.1. 1 -GS - General Student Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 623 Children's Restroom Page 5 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 20 - Alarms Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 20.02 - Toilet, Bathroom, or Shower Room - Visual Alarms Visual alarms are not provided at public or common use toilet, bathroom, or shower room. 4.28.1 215.1; Advisory 215.1; 702.1 907.9.1. 1 -EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 650 Faculty Restroom 20.04 - Common Use Areas - Visual Alarms Visual alarms are not provided in common use area(s) of the building such as meeting and conference rooms, open office space, classrooms, cafeterias, filing and photocopy rooms, employee break rooms, dressing, examination, and treatment rooms, and similar spaces that are not used solely as employee work areas. 4.28.1 215.2; 702.1 907.9.1. 1 -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 668 Multi- purpose Room 20.16A - Fire Extinguisher Cabinet Hardware - Mounting Height Where fire extinguishers are provided in cabinets, mounting height of the cabinet opening hardware is not compliant. (Compliant opening hardware is mounted 48” AFF maximum, or in existing buildings, the opening hardware is 54” AFF and parallel approach is provided.) 4.27.3 308.2.1; Fig. 308.2.1; 308.3.1; Fig. 308.3.1 1118B.4 (1); 1118B.5 ; 1118B.6 -68" high.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 670 Multi- purpose Room 20.03 - General Use Areas - Visual Alarms Visual alarms are not provided at public use area(s) of the building such as waiting areas, assembly areas, meeting rooms, corridors, stairways, hallways, and lobbies. (Visual alarms are not required in enclosed exit stairways, exterior exit stairs and exterior exit ramps.) 4.28.1 215.1; Advisory 215.1; 702.1 907.9.1. 1 -EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 686 Kitchen 20.03 - General Use Areas - Visual Alarms Visual alarms are not provided at public use area(s) of the building such as waiting areas, assembly areas, meeting rooms, corridors, stairways, hallways, and lobbies. (Visual alarms are not required in enclosed exit stairways, exterior exit stairs and exterior exit ramps.) 4.28.1 215.1; Advisory 215.1; 702.1 907.9.1. 1 -EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 688 Hallway Page 6 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 20 - Alarms Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 20.02 - Toilet, Bathroom, or Shower Room - Visual Alarms Visual alarms are not provided at public or common use toilet, bathroom, or shower room. 4.28.1 215.1; Advisory 215.1; 702.1 907.9.1. 1 -EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 708 Staff Restroom 20.04 - Common Use Areas - Visual Alarms Visual alarms are not provided in common use area(s) of the building such as meeting and conference rooms, open office space, classrooms, cafeterias, filing and photocopy rooms, employee break rooms, dressing, examination, and treatment rooms, and similar spaces that are not used solely as employee work areas. 4.28.1 215.2; 702.1 907.9.1. 1 -EW - Employee Work Area B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 712 Office 20.04 - Common Use Areas - Visual Alarms Visual alarms are not provided in common use area(s) of the building such as meeting and conference rooms, open office space, classrooms, cafeterias, filing and photocopy rooms, employee break rooms, dressing, examination, and treatment rooms, and similar spaces that are not used solely as employee work areas. 4.28.1 215.2; 702.1 907.9.1. 1 -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 731 Discovery Room 20.04 - Common Use Areas - Visual Alarms Visual alarms are not provided in common use area(s) of the building such as meeting and conference rooms, open office space, classrooms, cafeterias, filing and photocopy rooms, employee break rooms, dressing, examination, and treatment rooms, and similar spaces that are not used solely as employee work areas. 4.28.1 215.2; 702.1 907.9.1. 1 -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 738 Office 31Number of Key Notes for Group 20 - Alarms: Page 7 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 04 - Curb Ramps Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 04.01B - Curb Ramp Compliance Where accessible route crosses a curb, a curb ramp has not been provided. 4.7.1 406.1 1127B.5 item 1 2005 PROWA G-R303 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 165 School Grounds 04.02 - Slope Slope of the curb ramp exceeds 8.33% (or the least possible compliant slope). 4.7.2; 4.8.2 405.2; Advisory 405.2 1127B.5 item 3 2005 PROWA G- R303.2. 1.1; R303.2. 2.1 14%.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 166 School Grounds 04.04 - Counter Slope The running slopes of the road, gutter or accessible route adjoining the ramp exceed 5%. 4.7.2 406.2 1127B.5 item 3 2005 PROWA G- R303.3. 5 9.1%.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 167 School Grounds 04.09B - Grooved Border - Location A 12” wide grooved border has not been provided on the level surface of the walkway. --1127B.5 item 6 -On sloped part of curb ramp.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 168 School Grounds 04.10 - Detectable Warning Requirement Regardless of slope, the curb ramp does not have a detectable warning. 4.7.7; 4.29.2 705.1; Fig. 705.1 1127B.5 item 7 2005 PROWA G- R303.3. 2 None provided.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 169 School Grounds 5Number of Key Notes for Group 04 - Curb Ramps: Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation Page 8 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.12 - Hardware Mounting Height Mounting height of all operating hardware is not 30” min.. or 44” max.., as measured to the highest operable part. (1994 ADA Standards permit a max.. height of 48"; CBC Standards permit a range of 30” min.. to 44” max..) 4.13.9 -1133B.2 .5.2 -Hardware at 48" and 57" high.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 54 Soccer Field 11.12 - Hardware Mounting Height Mounting height of all operating hardware is not 30” min.. or 44” max.., as measured to the highest operable part. (1994 ADA Standards permit a max.. height of 48"; CBC Standards permit a range of 30” min.. to 44” max..) 4.13.9 -1133B.2 .5.2 -48" high.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 98 Paddle Tennis Courts 11.12 - Hardware Mounting Height Mounting height of all operating hardware is not 30” min.. or 44” max.., as measured to the highest operable part. (1994 ADA Standards permit a max.. height of 48"; CBC Standards permit a range of 30” min.. to 44” max..) 4.13.9 -1133B.2 .5.2 -51" to door hardware.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 186 Storage Room 11.12 - Hardware Mounting Height Mounting height of all operating hardware is not 30” min.. or 44” max.., as measured to the highest operable part. (1994 ADA Standards permit a max.. height of 48"; CBC Standards permit a range of 30” min.. to 44” max..) 4.13.9 -1133B.2 .5.2 -56" to door hardware.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 206 School Grounds 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 214 Classroom G 11.17B - Room/Space Identification Signs (Visual/Tactile Signs) Sign designating the permanent room or space does not comply with ADAAG and CBC requirements for tactile signs. 4.1.2(7) ; 4.30.1, 4, 5, 6 216.2; 703.1; 703.2; 703.5 1117B.5 .2, 3, 5, 6, 7 -PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 232 Classroom G Page 9 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.23A - Mounting Location (Visual/Tactile Signs) Sign is not mounted on the wall adjacent to the latch side of the door. OR At double leaf doors, the sign is not placed on the nearest adjacent wall. 4.30.6 703.4.2 1117B.5 .7 -PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 233 Classroom G 11.17B - Room/Space Identification Signs (Visual/Tactile Signs) Sign designating the permanent room or space does not comply with ADAAG and CBC requirements for tactile signs. 4.1.2(7) ; 4.30.1, 4, 5, 6 216.2; 703.1; 703.2; 703.5 1117B.5 .2, 3, 5, 6, 7 -PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 239 Classroom H 11.23A - Mounting Location (Visual/Tactile Signs) Sign is not mounted on the wall adjacent to the latch side of the door. OR At double leaf doors, the sign is not placed on the nearest adjacent wall. 4.30.6 703.4.2 1117B.5 .7 -PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 240 Classroom H 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 255 Classroom H 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 262 Classroom 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 277 Classroom Page 10 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 285 Classroom K 11.12 - Hardware Mounting Height Mounting height of all operating hardware is not 30” min.. or 44” max.., as measured to the highest operable part. (1994 ADA Standards permit a max.. height of 48"; CBC Standards permit a range of 30” min.. to 44” max..) 4.13.9 -1133B.2 .5.2 -53" to bolt.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 286 Classroom K 11.17B - Room/Space Identification Signs (Visual/Tactile Signs) Sign designating the permanent room or space does not comply with ADAAG and CBC requirements for tactile signs. 4.1.2(7) ; 4.30.1, 4, 5, 6 216.2; 703.1; 703.2; 703.5 1117B.5 .2, 3, 5, 6, 7 -PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 293 Classroom K 11.23A - Mounting Location (Visual/Tactile Signs) Sign is not mounted on the wall adjacent to the latch side of the door. OR At double leaf doors, the sign is not placed on the nearest adjacent wall. 4.30.6 703.4.2 1117B.5 .7 -PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 294 Classroom K 11.12 - Hardware Mounting Height Mounting height of all operating hardware is not 30” min.. or 44” max.., as measured to the highest operable part. (1994 ADA Standards permit a max.. height of 48"; CBC Standards permit a range of 30” min.. to 44” max..) 4.13.9 -1133B.2 .5.2 -53" to bolt.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 295 Classroom K 11.12 - Hardware Mounting Height Mounting height of all operating hardware is not 30” min.. or 44” max.., as measured to the highest operable part. (1994 ADA Standards permit a max.. height of 48"; CBC Standards permit a range of 30” min.. to 44” max..) 4.13.9 -1133B.2 .5.2 -53" to bolt.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 310 Classroom J Page 11 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 312 Classroom J 11.17B - Room/Space Identification Signs (Visual/Tactile Signs) Sign designating the permanent room or space does not comply with ADAAG and CBC requirements for tactile signs. 4.1.2(7) ; 4.30.1, 4, 5, 6 216.2; 703.1; 703.2; 703.5 1117B.5 .2, 3, 5, 6, 7 -PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 320 Classroom J 11.23A - Mounting Location (Visual/Tactile Signs) Sign is not mounted on the wall adjacent to the latch side of the door. OR At double leaf doors, the sign is not placed on the nearest adjacent wall. 4.30.6 703.4.2 1117B.5 .7 -PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 321 Classroom J 11.12 - Hardware Mounting Height Mounting height of all operating hardware is not 30” min.. or 44” max.., as measured to the highest operable part. (1994 ADA Standards permit a max.. height of 48"; CBC Standards permit a range of 30” min.. to 44” max..) 4.13.9 -1133B.2 .5.2 -53" to bolt.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 322 Classroom J 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -GS - General Student Use E - Non- Mandated Access Improveme nt 1 - Access into Facilities (28 CFR 36.304(c)(1)) 337 Montessori Classroom 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -GS - General Student Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 344 Montessori Classroom Page 12 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.12 - Hardware Mounting Height Mounting height of all operating hardware is not 30” min.. or 44” max.., as measured to the highest operable part. (1994 ADA Standards permit a max.. height of 48"; CBC Standards permit a range of 30” min.. to 44” max..) 4.13.9 -1133B.2 .5.2 -53" to bolt.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 359 Montessori Classroom 11.07D - Floor Mat - Attachment to Floor Floor mat used on a ground or floor surface is not securely attached. 4.5.3 303.2; Advisory 302.2 1124B.3 -Loose floor mat.GS - General Student Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 368 Classroom F 11.17B - Room/Space Identification Signs (Visual/Tactile Signs) Sign designating the permanent room or space does not comply with ADAAG and CBC requirements for tactile signs. 4.1.2(7) ; 4.30.1, 4, 5, 6 216.2; 703.1; 703.2; 703.5 1117B.5 .2, 3, 5, 6, 7 -GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 369 Classroom F 11.23A - Mounting Location (Visual/Tactile Signs) Sign is not mounted on the wall adjacent to the latch side of the door. OR At double leaf doors, the sign is not placed on the nearest adjacent wall. 4.30.6 703.4.2 1117B.5 .7 -GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 370 Classroom F 11.12 - Hardware Mounting Height Mounting height of all operating hardware is not 30” min.. or 44” max.., as measured to the highest operable part. (1994 ADA Standards permit a max.. height of 48"; CBC Standards permit a range of 30” min.. to 44” max..) 4.13.9 -1133B.2 .5.2 -Pinch type hardware for low door. GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 371 Classroom F 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -GS - General Student Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 373 Classroom F Page 13 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob and twist type lock.GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 390 Classroom F 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -GS - General Student Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 391 Classroom F 11.05A - Clear Opening - Single- Leaf Door When the door is open 90 degrees, clear opening width is not at least 32” measured between the face of the door and the doorstop on the latch side. 4.13.5 404.2.3 1133B.1 .1.1.1; 1133B.2 .2 -28 3/4" wide.GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 392 Classroom F 11.10B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -1 1/2" high.GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 393 Classroom F 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Pinch type hardware for low door. GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 395 Classroom F 11.12 - Hardware Mounting Height Mounting height of all operating hardware is not 30” min.. or 44” max.., as measured to the highest operable part. (1994 ADA Standards permit a max.. height of 48"; CBC Standards permit a range of 30” min.. to 44” max..) 4.13.9 -1133B.2 .5.2 -52" to bolt.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 402 Classroom F Page 14 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.12 - Hardware Mounting Height Mounting height of all operating hardware is not 30” min.. or 44” max.., as measured to the highest operable part. (1994 ADA Standards permit a max.. height of 48"; CBC Standards permit a range of 30” min.. to 44” max..) 4.13.9 -1133B.2 .5.2 -52" to bolt.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 407 Classroom E 11.12 - Hardware Mounting Height Mounting height of all operating hardware is not 30” min.. or 44” max.., as measured to the highest operable part. (1994 ADA Standards permit a max.. height of 48"; CBC Standards permit a range of 30” min.. to 44” max..) 4.13.9 -1133B.2 .5.2 -52" to bolt.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 423 Classroom E 11.10B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -1 1/2" high.GS - General Student Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 436 Classroom E - Restrooms 11.10B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -1 3/4" high.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 451 Office 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 452 Office 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 453 Office Page 15 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.12 - Hardware Mounting Height Mounting height of all operating hardware is not 30” min.. or 44” max.., as measured to the highest operable part. (1994 ADA Standards permit a max.. height of 48"; CBC Standards permit a range of 30” min.. to 44” max..) 4.13.9 -1133B.2 .5.2 -58" to knob.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 454 Office 11.12 - Hardware Mounting Height Mounting height of all operating hardware is not 30” min.. or 44” max.., as measured to the highest operable part. (1994 ADA Standards permit a max.. height of 48"; CBC Standards permit a range of 30” min.. to 44” max..) 4.13.9 -1133B.2 .5.2 -Pinch type hardware for low door. PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 455 Office 11.15A - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -Door stop.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 456 Office 11.13A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -6 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 457 Office 11.17B - Room/Space Identification Signs (Visual/Tactile Signs) Sign designating the permanent room or space does not comply with ADAAG and CBC requirements for tactile signs. 4.1.2(7) ; 4.30.1, 4, 5, 6 216.2; 703.1; 703.2; 703.5 1117B.5 .2, 3, 5, 6, 7 -PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 465 Office 11.23A - Mounting Location (Visual/Tactile Signs) Sign is not mounted on the wall adjacent to the latch side of the door. OR At double leaf doors, the sign is not placed on the nearest adjacent wall. 4.30.6 703.4.2 1117B.5 .7 -PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 466 Office Page 16 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 1 - Access into Facilities (28 CFR 36.304(c)(1)) 472 Office 11.17B - Room/Space Identification Signs (Visual/Tactile Signs) Sign designating the permanent room or space does not comply with ADAAG and CBC requirements for tactile signs. 4.1.2(7) ; 4.30.1, 4, 5, 6 216.2; 703.1; 703.2; 703.5 1117B.5 .2, 3, 5, 6, 7 -GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 481 Classroom E 11.23A - Mounting Location (Visual/Tactile Signs) Sign is not mounted on the wall adjacent to the latch side of the door. OR At double leaf doors, the sign is not placed on the nearest adjacent wall. 4.30.6 703.4.2 1117B.5 .7 -GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 482 Classroom E 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -GS - General Student Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 491 Classroom E 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -MS - Maintenance and Storage Only E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 528 Custodian Room 11.17B - Room/Space Identification Signs (Visual/Tactile Signs) Sign designating the permanent room or space does not comply with ADAAG and CBC requirements for tactile signs. 4.1.2(7) ; 4.30.1, 4, 5, 6 216.2; 703.1; 703.2; 703.5 1117B.5 .2, 3, 5, 6, 7 -GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 573 Classroom A Page 17 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.23A - Mounting Location (Visual/Tactile Signs) Sign is not mounted on the wall adjacent to the latch side of the door. OR At double leaf doors, the sign is not placed on the nearest adjacent wall. 4.30.6 703.4.2 1117B.5 .7 -GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 574 Classroom A 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -GS - General Student Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 581 Classroom A 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -GS - General Student Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 585 Classroom A 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -MS - Maintenance and Storage Only E - Non- Mandated Access Improveme nt 1 - Access into Facilities (28 CFR 36.304(c)(1)) 655 Utility Room 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob and twist type lock.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 659 Discovery room 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 660 Discovery room Page 18 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -38" deep landing to display cabinet. PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 661 Discovery room 11.13A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -6 LBF. operating force for closet sliding doors. PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 674 Multi- purpose Room 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Non-compliant hardware.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 675 Multi- purpose Room 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 678 Multi- purpose Room 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 679 Multi- purpose Room Page 19 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -2" on pull side due to cabinet.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 680 Multi- purpose Room 11.05A - Clear Opening - Single- Leaf Door When the door is open 90 degrees, clear opening width is not at least 32” measured between the face of the door and the doorstop on the latch side. 4.13.5 404.2.3 1133B.1 .1.1.1; 1133B.2 .2 -30" wide.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 681 Multi- purpose Room 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 710 Office 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -EW - Employee Work Area E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 711 Office 11.05A - Clear Opening - Single- Leaf Door When the door is open 90 degrees, clear opening width is not at least 32” measured between the face of the door and the doorstop on the latch side. 4.13.5 404.2.3 1133B.1 .1.1.1; 1133B.2 .2 -30".EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 713 Office Page 20 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.10B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -3/4" high.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 714 Office 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -MS - Maintenance and Storage Only E - Non- Mandated Access Improveme nt 1 - Access into Facilities (28 CFR 36.304(c)(1)) 717 Storage 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -2" pull strike clearance.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 719 Office 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 720 Office 11.05A - Clear Opening - Single- Leaf Door When the door is open 90 degrees, clear opening width is not at least 32” measured between the face of the door and the doorstop on the latch side. 4.13.5 404.2.3 1133B.1 .1.1.1; 1133B.2 .2 -30" wide.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 721 Office Page 21 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -EW - Employee Work Area E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 722 Office 11.15A - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -Door stop.EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 723 Office 11.05A - Clear Opening - Single- Leaf Door When the door is open 90 degrees, clear opening width is not at least 32” measured between the face of the door and the doorstop on the latch side. 4.13.5 404.2.3 1133B.1 .1.1.1; 1133B.2 .2 -30" wide.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 724 Hallway 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 725 Hallway 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -EW - Employee Work Area E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 726 Hallway Page 22 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -No strike side clearance due to cabinet. EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 727 Hallway 11.17B - Room/Space Identification Signs (Visual/Tactile Signs) Sign designating the permanent room or space does not comply with ADAAG and CBC requirements for tactile signs. 4.1.2(7) ; 4.30.1, 4, 5, 6 216.2; 703.1; 703.2; 703.5 1117B.5 .2, 3, 5, 6, 7 -PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 741 Office 11.23A - Mounting Location (Visual/Tactile Signs) Sign is not mounted on the wall adjacent to the latch side of the door. OR At double leaf doors, the sign is not placed on the nearest adjacent wall. 4.30.6 703.4.2 1117B.5 .7 -PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 742 Office 11.17B - Room/Space Identification Signs (Visual/Tactile Signs) Sign designating the permanent room or space does not comply with ADAAG and CBC requirements for tactile signs. 4.1.2(7) ; 4.30.1, 4, 5, 6 216.2; 703.1; 703.2; 703.5 1117B.5 .2, 3, 5, 6, 7 -PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 750 Discovery Room Page 23 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.23A - Mounting Location (Visual/Tactile Signs) Sign is not mounted on the wall adjacent to the latch side of the door. OR At double leaf doors, the sign is not placed on the nearest adjacent wall. 4.30.6 703.4.2 1117B.5 .7 -PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 751 Discovery Room 11.07D - Floor Mat - Attachment to Floor Floor mat used on a ground or floor surface is not securely attached. 4.5.3 303.2; Advisory 302.2 1124B.3 -Loose floor mat.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 752 Discovery Room 11.17B - Room/Space Identification Signs (Visual/Tactile Signs) Sign designating the permanent room or space does not comply with ADAAG and CBC requirements for tactile signs. 4.1.2(7) ; 4.30.1, 4, 5, 6 216.2; 703.1; 703.2; 703.5 1117B.5 .2, 3, 5, 6, 7 -PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 762 Multi- purpose Room 11.23A - Mounting Location (Visual/Tactile Signs) Sign is not mounted on the wall adjacent to the latch side of the door. OR At double leaf doors, the sign is not placed on the nearest adjacent wall. 4.30.6 703.4.2 1117B.5 .7 -PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 763 Multi- purpose Room 11.07D - Floor Mat - Attachment to Floor Floor mat used on a ground or floor surface is not securely attached. 4.5.3 303.2; Advisory 302.2 1124B.3 -Loose floor mat.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 768 Multi- purpose Room 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 771 Multi- purpose Room Page 24 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.07D - Floor Mat - Attachment to Floor Floor mat used on a ground or floor surface is not securely attached. 4.5.3 303.2; Advisory 302.2 1124B.3 -Loose floor mat.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 780 Multi- purpose Room 11.17B - Room/Space Identification Signs (Visual/Tactile Signs) Sign designating the permanent room or space does not comply with ADAAG and CBC requirements for tactile signs. 4.1.2(7) ; 4.30.1, 4, 5, 6 216.2; 703.1; 703.2; 703.5 1117B.5 .2, 3, 5, 6, 7 -PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 783 Multi- purpose Room 11.23A - Mounting Location (Visual/Tactile Signs) Sign is not mounted on the wall adjacent to the latch side of the door. OR At double leaf doors, the sign is not placed on the nearest adjacent wall. 4.30.6 703.4.2 1117B.5 .7 -PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 784 Multi- purpose Room 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 792 Multi- purpose Room 11.07D - Floor Mat - Attachment to Floor Floor mat used on a ground or floor surface is not securely attached. 4.5.3 303.2; Advisory 302.2 1124B.3 -Loose floor mat.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 794 Multi- purpose Room 95Number of Key Notes for Group 11 - Doors and Gates: Group 05 - Drinking Fountains Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation Page 25 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 05 - Drinking Fountains Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 05.07 - Clear Floor Space Drinking fountain does not have a 30” x 48” clear floor space that adjoins or overlaps an accessible route of travel and that allows a forward approach by wheelchair users. (A side approach is not acceptable.) 4.15.5(1 ); Figs. 27(c) and (d) 305.1 1115B.4 .6 item 2 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 26 Sidewalk 05.09A - Spout Height for Wheelchair Users The spout outlet is higher than 36” from the floor. 4.15.2 602.4; 602.6; Advisory 602.6 1115B.4 .6 item 4 -38" high.PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 27 Sidewalk 05.09B - Water Flow Height The water flow is less than 4” high and does not allow the insertion of a cup under the flow. 4.15.3 602.6; Advisory 602.6 1115B.4 .6 item 5 -1" high.PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 28 Sidewalk 05.10A - Bubbler Location The bubbler outlet is not within 6" of the front edge of the unit. 4.15.3 -1115B.4 .6 item 4 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 29 Sidewalk 05.10B - Water Flow Trajectory The water flow trajectory is not parallel or nearly parallel to the front edge. 4.15.3 602.6; Advisory 602.6 1115B.4 .6 item 4 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 30 Sidewalk 05.11 - Water Flow - Round or Oval Bowl For a fountain with a round or oval bowl, the water flow is not within 3” of the fountain's front edge. 4.15.3 -1115B.4 .6 item 5 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 31 Sidewalk Page 26 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 05 - Drinking Fountains Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 05.01A - "Hi" Drinking Fountain Requirement Where there is only one drinking fountain area on a floor (e.g.., an area with a drinking fountain or separate drinking fountains), it is accessible to wheelchair users and not to persons who have difficulty bending or stooping (i.e., the required accessibility for persons who have difficulty bending or stooping on each floor has not been provided). 4.1.3(10 )(a); 4.15.1 211.1; 211.2 1115B.4 .6 item 1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 59 Soccer Field 05.03 - Accessible Route The accessible drinking fountain is not located on an accessible route. 4.1.3(10 )(b) 206.2.4 1115B.4 .6 item 1 -No POT to DF.PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 60 Soccer Field 05.10A - Bubbler Location The bubbler outlet is not within 6" of the front edge of the unit. 4.15.3 -1115B.4 .6 item 4 -38" high.PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 61 Soccer Field 05.03 - Accessible Route The accessible drinking fountain is not located on an accessible route. 4.1.3(10 )(b) 206.2.4 1115B.4 .6 item 1 -No POT to DF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 92 Paddle Tennis Courts 05.01A - "Hi" Drinking Fountain Requirement Where there is only one drinking fountain area on a floor (e.g.., an area with a drinking fountain or separate drinking fountains), it is accessible to wheelchair users and not to persons who have difficulty bending or stooping (i.e., the required accessibility for persons who have difficulty bending or stooping on each floor has not been provided). 4.1.3(10 )(a); 4.15.1 211.1; 211.2 1115B.4 .6 item 1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 93 Paddle Tennis Courts Page 27 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 05 - Drinking Fountains Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 05.13 - Operation The controls are not compliant.(Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 602.3; 309.4 1115B.4 .6 item 4 -Knobs.PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 120 School Grounds 05.01A - "Hi" Drinking Fountain Requirement Where there is only one drinking fountain area on a floor (e.g.., an area with a drinking fountain or separate drinking fountains), it is accessible to wheelchair users and not to persons who have difficulty bending or stooping (i.e., the required accessibility for persons who have difficulty bending or stooping on each floor has not been provided). 4.1.3(10 )(a); 4.15.1 211.1; 211.2 1115B.4 .6 item 1 -Missing bubblers.PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 121 School Grounds 05.01A - "Hi" Drinking Fountain Requirement Where there is only one drinking fountain area on a floor (e.g.., an area with a drinking fountain or separate drinking fountains), it is accessible to wheelchair users and not to persons who have difficulty bending or stooping (i.e., the required accessibility for persons who have difficulty bending or stooping on each floor has not been provided). 4.1.3(10 )(a); 4.15.1 211.1; 211.2 1115B.4 .6 item 1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 128 School Grounds 05.01A - "Hi" Drinking Fountain Requirement Where there is only one drinking fountain area on a floor (e.g.., an area with a drinking fountain or separate drinking fountains), it is accessible to wheelchair users and not to persons who have difficulty bending or stooping (i.e., the required accessibility for persons who have difficulty bending or stooping on each floor has not been provided). 4.1.3(10 )(a); 4.15.1 211.1; 211.2 1115B.4 .6 item 1 -Non-functioning.PV - Public/Visitor Use A - Safety Hazard 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 132 School Grounds Page 28 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 05 - Drinking Fountains Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 05.01B - "Lo" Drinking Fountain Requirement Where there is only one drinking fountain area on a floor (e.g.., an area with a drinking fountain or separate drinking fountains), it is accessible to persons who have difficulty bending or stooping and not to wheelchair users (i.e., the required accessibility for wheelchair users on each floor has not been provided). 4.1.3(10 )(a); 4.15.1 211.1; 211.2 1115B.4 .6 item 1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 155 Basketball Courts 05.01A - "Hi" Drinking Fountain Requirement Where there is only one drinking fountain area on a floor (e.g.., an area with a drinking fountain or separate drinking fountains), it is accessible to wheelchair users and not to persons who have difficulty bending or stooping (i.e., the required accessibility for persons who have difficulty bending or stooping on each floor has not been provided). 4.1.3(10 )(a); 4.15.1 211.1; 211.2 1115B.4 .6 item 1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 156 Basketball Courts 17Number of Key Notes for Group 05 - Drinking Fountains: Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.08 - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 51 Soccer Field 10.02 - Entrance Sign Accessible entrance is not identified by an ISA.28 CFR 35.163( b)1 216.6 1117B.5 .8.1.2 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 52 Soccer Field Page 29 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 53 Soccer Field 10.07A - Landing - Level and Clear Floor is not level (slope is greater than 2% in some or all directions). OR Floor is not clear within the required maneuvering space. 4.13.6; Fig. 25 305; 404.2.4. 4 1133B.2 .4 -Landing not level, no POT provided. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 55 Soccer Field 10.08 - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 97 Paddle Tennis Courts 10.08 - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 108 Playground 10.07A - Landing - Level and Clear Floor is not level (slope is greater than 2% in some or all directions). OR Floor is not clear within the required maneuvering space. 4.13.6; Fig. 25 305; 404.2.4. 4 1133B.2 .4 -10.3% RS at door landing.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 185 Storage Room 10.07A - Landing - Level and Clear Floor is not level (slope is greater than 2% in some or all directions). OR Floor is not clear within the required maneuvering space. 4.13.6; Fig. 25 305; 404.2.4. 4 1133B.2 .4 -3.5% RS at gate landing.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 204 School Grounds Page 30 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.08 - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 205 School Grounds 10.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -8 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 211 Classroom G 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 212 Classroom G 10.07A - Landing - Level and Clear Floor is not level (slope is greater than 2% in some or all directions). OR Floor is not clear within the required maneuvering space. 4.13.6; Fig. 25 305; 404.2.4. 4 1133B.2 .4 -4.7% RS at door landing.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 213 Classroom G 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 215 Classroom G 10.09B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -Compound threshold.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 216 Classroom G Page 31 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.02 - Entrance Sign Accessible entrance is not identified by an ISA.28 CFR 35.163( b)1 216.6 1117B.5 .8.1.2 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 228 Classroom G 10.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab.404 .2.4.1; Fig.404. 2.4.1 1133B.2 .4.2; Fig. 11B-26 -4" due to FE.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 229 Classroom G 10.09B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -Compound threshold.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 230 Classroom G 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 231 Classroom G 10.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -10 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 234 Classroom G Page 32 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 235 Classroom G 10.02 - Entrance Sign Accessible entrance is not identified by an ISA.28 CFR 35.163( b)1 216.6 1117B.5 .8.1.2 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 237 Classroom H 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 238 Classroom H 10.09B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -Compound threshold.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 241 Classroom H 10.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab.404 .2.4.1; Fig.404. 2.4.1 1133B.2 .4.2; Fig. 11B-26 -4" due to FE.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 242 Classroom H Page 33 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 243 Classroom H 10.07A - Landing - Level and Clear Floor is not level (slope is greater than 2% in some or all directions). OR Floor is not clear within the required maneuvering space. 4.13.6; Fig. 25 305; 404.2.4. 4 1133B.2 .4 -3.2% RS at door landing.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 245 Classroom H 10.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -8 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 246 Classroom H 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 252 Classroom H 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 253 Classroom H 10.07A - Landing - Level and Clear Floor is not level (slope is greater than 2% in some or all directions). OR Floor is not clear within the required maneuvering space. 4.13.6; Fig. 25 305; 404.2.4. 4 1133B.2 .4 -3.3% RS at door landing.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 254 Classroom H Page 34 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.09B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -Compound threshold.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 256 Classroom H 10.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -10 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 258 Classroom H 10.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab.404 .2.4.1; Fig.404. 2.4.1 1133B.2 .4.2; Fig. 11B-26 -0" due to furniture.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 259 Classroom H 10.02 - Entrance Sign Accessible entrance is not identified by an ISA.28 CFR 35.163( b)1 216.6 1117B.5 .8.1.2 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 260 Classroom 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 261 Classroom Page 35 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.09B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -Compound threshold.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 263 Classroom 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 264 Classroom 10.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab.404 .2.4.1; Fig.404. 2.4.1 1133B.2 .4.2; Fig. 11B-26 -4" due to FE.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 265 Classroom 10.07A - Landing - Level and Clear Floor is not level (slope is greater than 2% in some or all directions). OR Floor is not clear within the required maneuvering space. 4.13.6; Fig. 25 305; 404.2.4. 4 1133B.2 .4 -2.3% RS at door landing.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 267 Classroom 10.07A - Landing - Level and Clear Floor is not level (slope is greater than 2% in some or all directions). OR Floor is not clear within the required maneuvering space. 4.13.6; Fig. 25 305; 404.2.4. 4 1133B.2 .4 -3.1% RS at door landing.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 273 Classroom Page 36 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 274 Classroom 10.09B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -Compound threshold.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 275 Classroom 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 276 Classroom 10.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab.404 .2.4.1; Fig.404. 2.4.1 1133B.2 .4.2; Fig. 11B-26 -1" due to furniture.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 279 Classroom 10.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -10 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 280 Classroom K Page 37 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 281 Classroom K 10.09B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -Compound threshold.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 282 Classroom K 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 284 Classroom K 10.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab.404 .2.4.1; Fig.404. 2.4.1 1133B.2 .4.2; Fig. 11B-26 -Furniture.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 287 Classroom K 10.02 - Entrance Sign Accessible entrance is not identified by an ISA.28 CFR 35.163( b)1 216.6 1117B.5 .8.1.2 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 288 Classroom K Page 38 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.07A - Landing - Level and Clear Floor is not level (slope is greater than 2% in some or all directions). OR Floor is not clear within the required maneuvering space. 4.13.6; Fig. 25 305; 404.2.4. 4 1133B.2 .4 -3.1% RS at door landing.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 289 Classroom K 10.09B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -Compound threshold.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 290 Classroom K 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 291 Classroom K 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 292 Classroom K 10.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -9 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 297 Classroom K 10.07A - Landing - Level and Clear Floor is not level (slope is greater than 2% in some or all directions). OR Floor is not clear within the required maneuvering space. 4.13.6; Fig. 25 305; 404.2.4. 4 1133B.2 .4 -4.3% RS at door landing.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 306 Classroom J Page 39 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -10 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 307 Classroom J 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 308 Classroom J 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 309 Classroom J 10.09B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -Compound threshold.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 311 Classroom J 10.02 - Entrance Sign Accessible entrance is not identified by an ISA.28 CFR 35.163( b)1 216.6 1117B.5 .8.1.2 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 314 Classroom J 10.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -6 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 315 Classroom J Page 40 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.07A - Landing - Level and Clear Floor is not level (slope is greater than 2% in some or all directions). OR Floor is not clear within the required maneuvering space. 4.13.6; Fig. 25 305; 404.2.4. 4 1133B.2 .4 -2.9% RS at door landing.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 316 Classroom J 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 317 Classroom J 10.09B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -Compound threshold.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 318 Classroom J 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 319 Classroom J 10.02 - Entrance Sign Accessible entrance is not identified by an ISA.28 CFR 35.163( b)1 216.6 1117B.5 .8.1.2 -GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 332 Montessori Classroom 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 333 Montessori Classroom Page 41 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.09B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -Compound threshold.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 334 Montessori Classroom 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -GS - General Student Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 335 Montessori Classroom 10.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -8 LBF.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 336 Montessori Classroom 10.12 - Other Door Requirements Entrance door does not comply with all applicable ADAAG and CBC accessibility requirements. 4.13 404 1133B.1 -Pinch type hardware for low door. GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 339 Montessori Classroom 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 340 Montessori Classroom 10.09B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -Compound threshold.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 341 Montessori Classroom Page 42 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -GS - General Student Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 342 Montessori Classroom 10.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -8 LBF.GS - General Student Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 343 Montessori Classroom 10.09B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -1 1/2" high.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 355 Montessori Classroom 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 357 Montessori Classroom 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -GS - General Student Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 358 Montessori Classroom 10.08 - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -9 1/2".GS - General Student Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 360 Montessori Classroom Page 43 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab.404 .2.4.1; Fig.404. 2.4.1 1133B.2 .4.2; Fig. 11B-26 -18" x 40" door landing.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 361 Montessori Classroom 10.02 - Entrance Sign Accessible entrance is not identified by an ISA.28 CFR 35.163( b)1 216.6 1117B.5 .8.1.2 -GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 362 Classroom F 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 363 Classroom F 10.09B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -Compound threshold.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 364 Classroom F 10.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -7 LBF.GS - General Student Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 365 Classroom F Page 44 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -GS - General Student Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 367 Classroom F 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 372 Classroom F 10.09B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -Compound threshold.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 374 Classroom F 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Pinch type hardware for low door. GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 375 Classroom F 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -GS - General Student Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 376 Classroom F 10.07A - Landing - Level and Clear Floor is not level (slope is greater than 2% in some or all directions). OR Floor is not clear within the required maneuvering space. 4.13.6; Fig. 25 305; 404.2.4. 4 1133B.2 .4 -3.3% RS at door landing.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 377 Classroom F Page 45 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.07A - Landing - Level and Clear Floor is not level (slope is greater than 2% in some or all directions). OR Floor is not clear within the required maneuvering space. 4.13.6; Fig. 25 305; 404.2.4. 4 1133B.2 .4 -2.3% RS at door landing.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 396 Classroom F 10.08 - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -8" high.GS - General Student Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 397 Classroom F 10.09B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -1" high.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 398 Classroom F 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob and twist type hardware.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 399 Classroom F 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -GS - General Student Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 400 Classroom F 10.08 - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -8" high.GS - General Student Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 404 Classroom E Page 46 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob and twist type hardware.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 405 Classroom E 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -GS - General Student Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 406 Classroom E 10.09B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -1" high.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 408 Classroom E 10.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab.404 .2.4.1; Fig.404. 2.4.1 1133B.2 .4.2; Fig. 11B-26 -Door landing 22" deep x 6" on strike side. GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 409 Classroom E Page 47 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.08 - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -8" high.GS - General Student Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 420 Classroom E 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob and twist type hardware.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 421 Classroom E 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -GS - General Student Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 422 Classroom E 10.09B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -1" threshold.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 424 Classroom E Page 48 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab.404 .2.4.1; Fig.404. 2.4.1 1133B.2 .4.2; Fig. 11B-26 -Door landing 22" deep x 6" on strike side. GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 425 Classroom E 10.02 - Entrance Sign Accessible entrance is not identified by an ISA.28 CFR 35.163( b)1 216.6 1117B.5 .8.1.2 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 458 Office 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 459 Office 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 460 Office 10.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -6 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 461 Office Page 49 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.07A - Landing - Level and Clear Floor is not level (slope is greater than 2% in some or all directions). OR Floor is not clear within the required maneuvering space. 4.13.6; Fig. 25 305; 404.2.4. 4 1133B.2 .4 -4.9% slope at door landing.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 462 Office 10.09B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -Compound threshold.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 464 Office 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 467 Office 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 468 Office 10.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -6 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 469 Office 10.07A - Landing - Level and Clear Floor is not level (slope is greater than 2% in some or all directions). OR Floor is not clear within the required maneuvering space. 4.13.6; Fig. 25 305; 404.2.4. 4 1133B.2 .4 -2.6% slope at door landing.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 470 Office Page 50 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.09A - > 1/4" Changes in Level - Threshold Where threshold is 1/4" min.. to 1/2" max.. in height, change in level is not beveled at 1:2 or less. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -Compound threshold.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 473 Office 10.01 - Entrances Serving Site Arrival Points There is not at least one accessible building entrance connected by an on-site accessible route to each type of site arrival points (i.e., public transportation stops, accessible parking, passenger loading zones, and public streets or sidewalks). 4.14.1; 4.3; 4.3.2(1) 206.4; 206.5.1 1114B.1 .2 -GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 474 Classroom E 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 475 Classroom E 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -GS - General Student Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 476 Classroom E 10.09A - > 1/4" Changes in Level - Threshold Where threshold is 1/4" min.. to 1/2" max.. in height, change in level is not beveled at 1:2 or less. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -Compound threshold.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 477 Classroom E Page 51 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab.404 .2.4.1; Fig.404. 2.4.1 1133B.2 .4.2; Fig. 11B-26 -3" strike clearance due to furniture. GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 478 Classroom E 10.12 - Other Door Requirements Entrance door does not comply with all applicable ADAAG and CBC accessibility requirements. 4.13 404 1133B.1 -Non-compliant hardware for low door. GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 479 Classroom E 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 485 Classroom E 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -GS - General Student Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 486 Classroom E 10.09A - > 1/4" Changes in Level - Threshold Where threshold is 1/4" min.. to 1/2" max.. in height, change in level is not beveled at 1:2 or less. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -Compound threshold.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 487 Classroom E Page 52 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.12 - Other Door Requirements Entrance door does not comply with all applicable ADAAG and CBC accessibility requirements. 4.13 404 1133B.1 -Non-compliant hardware for low door. GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 488 Classroom E 10.09A - > 1/4" Changes in Level - Threshold Where threshold is 1/4" min.. to 1/2" max.. in height, change in level is not beveled at 1:2 or less. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -Compound threshold.MS - Maintenance and Storage Only C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 529 Custodian Room 10.02 - Entrance Sign Accessible entrance is not identified by an ISA.28 CFR 35.163( b)1 216.6 1117B.5 .8.1.2 -GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 565 Classroom A 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -GS - General Student Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 566 Classroom A 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 567 Classroom A Page 53 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab.404 .2.4.1; Fig.404. 2.4.1 1133B.2 .4.2; Fig. 11B-26 -Low door encroaches door maneuvering space. GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 568 Classroom A 10.07A - Landing - Level and Clear Floor is not level (slope is greater than 2% in some or all directions). OR Floor is not clear within the required maneuvering space. 4.13.6; Fig. 25 305; 404.2.4. 4 1133B.2 .4 -2.4% slope at door landing.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 569 Classroom A 10.09A - > 1/4" Changes in Level - Threshold Where threshold is 1/4" min.. to 1/2" max.. in height, change in level is not beveled at 1:2 or less. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -Compound threshold.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 570 Classroom A 10.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -6 LBF.GS - General Student Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 572 Classroom A 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -GS - General Student Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 575 Classroom A Page 54 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 576 Classroom A 10.07A - Landing - Level and Clear Floor is not level (slope is greater than 2% in some or all directions). OR Floor is not clear within the required maneuvering space. 4.13.6; Fig. 25 305; 404.2.4. 4 1133B.2 .4 -2.4% slope at door landing.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 577 Classroom A 10.09A - > 1/4" Changes in Level - Threshold Where threshold is 1/4" min.. to 1/2" max.. in height, change in level is not beveled at 1:2 or less. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -Compound threshold.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 578 Classroom A 10.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -8 LBF.GS - General Student Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 580 Classroom A 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 582 Classroom A 10.08 - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -Door stop.GS - General Student Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 583 Classroom A Page 55 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -GS - General Student Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 584 Classroom A 10.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab.404 .2.4.1; Fig.404. 2.4.1 1133B.2 .4.2; Fig. 11B-26 -3 1/2" strike clearance to cabinet. GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 586 Classroom A 10.09B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -1" high.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 587 Classroom A 10.02 - Entrance Sign Accessible entrance is not identified by an ISA.28 CFR 35.163( b)1 216.6 1117B.5 .8.1.2 -GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 588 Playground 10.07A - Landing - Level and Clear Floor is not level (slope is greater than 2% in some or all directions). OR Floor is not clear within the required maneuvering space. 4.13.6; Fig. 25 305; 404.2.4. 4 1133B.2 .4 -2.2% to 2.9% slope at gate landing. GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 589 Playground Page 56 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.08 - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -GS - General Student Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 590 Playground 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 591 Playground 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Non-compliant hardware.MS - Maintenance and Storage Only C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 654 Utility Room 10.16 - Other - Building Entrances and Exits See Additional Comments ----Concrete to grass transition.MS - Maintenance and Storage Only C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 656 Utility Room Page 57 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab.404 .2.4.1; Fig.404. 2.4.1 1133B.2 .4.2; Fig. 11B-26 -6.7% CS at door landing.MS - Maintenance and Storage Only C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 657 Utility Room 10.16 - Other - Building Entrances and Exits See Additional Comments ----Door landing runs along ramp.MS - Maintenance and Storage Only C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 658 Utility Room 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Hardware not compliant.MS - Maintenance and Storage Only C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 716 Storage 10.09A - > 1/4" Changes in Level - Threshold Where threshold is 1/4" min.. to 1/2" max.. in height, change in level is not beveled at 1:2 or less. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -Not leveled.MS - Maintenance and Storage Only C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 718 Storage 10.02 - Entrance Sign Accessible entrance is not identified by an ISA.28 CFR 35.163( b)1 216.6 1117B.5 .8.1.2 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 740 Office Page 58 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 743 Office 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 744 Office 10.07A - Landing - Level and Clear Floor is not level (slope is greater than 2% in some or all directions). OR Floor is not clear within the required maneuvering space. 4.13.6; Fig. 25 305; 404.2.4. 4 1133B.2 .4 -3.4% slope at door landing.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 745 Office 10.09B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -Compound threshold.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 746 Office 10.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -10 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 748 Office 10.02 - Entrance Sign Accessible entrance is not identified by an ISA.28 CFR 35.163( b)1 216.6 1117B.5 .8.1.2 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 749 Discovery Room Page 59 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 753 Discovery Room 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 754 Discovery Room 10.09B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 755 Discovery Room 10.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -8 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 757 Discovery Room 10.07A - Landing - Level and Clear Floor is not level (slope is greater than 2% in some or all directions). OR Floor is not clear within the required maneuvering space. 4.13.6; Fig. 25 305; 404.2.4. 4 1133B.2 .4 -4.0% slope at door landing.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 758 Discovery Room 10.02 - Entrance Sign Accessible entrance is not identified by an ISA.28 CFR 35.163( b)1 216.6 1117B.5 .8.1.2 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 759 Multi- purpose Room Page 60 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Thumb latch.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 760 Multi- purpose Room 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 761 Multi- purpose Room 10.09B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -Compound threshold.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 764 Multi- purpose Room 10.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -9 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 766 Multi- purpose Room 10.11B - Hardware Operating Effort The force required to activate handles, pulls, latches, locks, and other operable parts of door exceeds 5 lbs. 4.27.4 309.4 1117B.6 item 4 -8 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 767 Multi- purpose Room 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 769 Multi- purpose Room Page 61 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Thumb latch.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 770 Multi- purpose Room 10.09B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -Compound threshold.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 772 Multi- purpose Room 10.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -12 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 773 Multi- purpose Room 10.11B - Hardware Operating Effort The force required to activate handles, pulls, latches, locks, and other operable parts of door exceeds 5 lbs. 4.27.4 309.4 1117B.6 item 4 -10 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 775 Multi- purpose Room 10.07A - Landing - Level and Clear Floor is not level (slope is greater than 2% in some or all directions). OR Floor is not clear within the required maneuvering space. 4.13.6; Fig. 25 305; 404.2.4. 4 1133B.2 .4 -2.7% slope at door landing.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 776 Multi- purpose Room 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Thumb latch.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 777 Multi- purpose Room Page 62 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -10 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 778 Multi- purpose Room 10.11B - Hardware Operating Effort The force required to activate handles, pulls, latches, locks, and other operable parts of door exceeds 5 lbs. 4.27.4 309.4 1117B.6 item 4 -10 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 779 Multi- purpose Room 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 781 Multi- purpose Room 10.09B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -Compound threshold.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 782 Multi- purpose Room 10.07A - Landing - Level and Clear Floor is not level (slope is greater than 2% in some or all directions). OR Floor is not clear within the required maneuvering space. 4.13.6; Fig. 25 305; 404.2.4. 4 1133B.2 .4 -3.0% slope at door landing.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 786 Multi- purpose Room 10.07A - Landing - Level and Clear Floor is not level (slope is greater than 2% in some or all directions). OR Floor is not clear within the required maneuvering space. 4.13.6; Fig. 25 305; 404.2.4. 4 1133B.2 .4 -3.5% slope at door landing.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 787 Multi- purpose Room Page 63 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -10 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 788 Multi- purpose Room 10.11B - Hardware Operating Effort The force required to activate handles, pulls, latches, locks, and other operable parts of door exceeds 5 lbs. 4.27.4 309.4 1117B.6 item 4 -10 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 789 Multi- purpose Room 10.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab.404 .2.4.1; Fig.404. 2.4.1 1133B.2 .4.2; Fig. 11B-26 -7" on push side.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 790 Multi- purpose Room 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Thumb latch.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 791 Multi- purpose Room 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 793 Multi- purpose Room Page 64 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.09B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -Compound threshold.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 795 Multi- purpose Room 192Number of Key Notes for Group 10 - Entrances and Exits: Group 12A - Interior Accessible Route Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 12A.02B - 36" Width Standard The accessible route of travel is not at least 36” wide where the occupancy load is < 10. (For a depth of 24" max.., clear opening width may be reduced to 32" min..) (Doorways are compliant when the door, open 90 degrees, affords a clear opening width of at least 32”.) 4.3.3 403.5.1 1133B.3 .1 -29" to furniture.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 689 Hallway 1Number of Key Notes for Group 12A - Interior Accessible Route: Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.15 - Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Uneven and not stable surface provided. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 56 Soccer Field 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -3.1% to 6.2% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 57 Soccer Field Page 65 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.11 - Ramps This portion of an accessible route with a slope greater than 5% does not comply with the requirements for compliant ramps. 4.8.1 405 1133B.5 -2.4% CS, & 7.8% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 58 Soccer Field 03B.13 - > 1/2" Changes in Level Curb ramps, ramps, or elevators are not used for changes in level greater than 1/2 inch. (Lifts may only be used in certain limited situations.) 4.5.2 303.4 1124B.2 -3/4" level change.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 95 Paddle Tennis Courts 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.3%.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 96 Paddle Tennis Courts 03B.01 - On- site Accessible Route of Travel There is no accessible route within the property line of the site linking an accessible building entrance with site arrival points serving the following, if provided: public transportation stops, accessible parking, passenger loading zones, and public sidewalks. 4.1.2(1) 202.2.1; Advisory 206.2.1 1114B.1 .2; 1127B.1 -No POT connects to stairs at top and bottom landings. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 119 Bottom Stairs 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.3% to 3.2% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 122 School Grounds 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -4.6%.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 123 School Grounds 03B.13 - > 1/2" Changes in Level Curb ramps, ramps, or elevators are not used for changes in level greater than 1/2 inch. (Lifts may only be used in certain limited situations.) 4.5.2 303.4 1124B.2 -1/2" level change.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 124 School Grounds Page 66 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.2% to 3.5% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 125 School Grounds 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.2%.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 126 School Grounds 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.3% to 4.0% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 129 School Grounds 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.2% to 3.9% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 133 School Grounds 03B.12 - > 1/4" Changes in Level Where walkway levels change abruptly, the vertical difference between them exceeds 1/4 inch. Or changes in level between 1/4 inch and 1/2 inch are beveled with a slope greater than 1:2. 4.5.2 303.2; 303.3 1124B.2 -1/4" level change.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 134 School Grounds 03B.13 - > 1/2" Changes in Level Curb ramps, ramps, or elevators are not used for changes in level greater than 1/2 inch. (Lifts may only be used in certain limited situations.) 4.5.2 303.4 1124B.2 -1" level change.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 144 Stairs 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.8% slope at basketball court.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 152 Basketball Courts Page 67 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -3.0% CS at tetherball court PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 153 Basketball Courts 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.7% to 3.4% CS at volleyball court PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 154 Basketball Courts 03B.12 - > 1/4" Changes in Level Where walkway levels change abruptly, the vertical difference between them exceeds 1/4 inch. Or changes in level between 1/4 inch and 1/2 inch are beveled with a slope greater than 1:2. 4.5.2 303.2; 303.3 1124B.2 -1" crack.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 163 Basketball Courts 03B.12 - > 1/4" Changes in Level Where walkway levels change abruptly, the vertical difference between them exceeds 1/4 inch. Or changes in level between 1/4 inch and 1/2 inch are beveled with a slope greater than 1:2. 4.5.2 303.2; 303.3 1124B.2 -3/4" crack.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 164 Basketball Courts 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -7.5% at curb ramp top landing.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 170 School Grounds 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.4% to 6.6% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 171 School Grounds 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.5% to 2.9% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 172 School Grounds Page 68 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.22 - Other - On-Site Accessible Path of Travel See Additional Comments ----4" level change to flag pole.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 173 School Grounds 03B.22 - Other - On-Site Accessible Path of Travel See Additional Comments ----66" to rope.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 174 School Grounds 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.5% to 6.3% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 175 Driveway 03B.10 - Running Slope Slope of the accessible route of travel exceeds 1:20. 4.3.7 403.3 1133B.7 .3 -6.6% to 12.1% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 176 Driveway 03B.22 - Other - On-Site Accessible Path of Travel See Additional Comments ----1" gap.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 177 Driveway Page 69 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.21 - Hazardous Vehicular Areas - Detectable Warnings Where a walk crosses or adjoins the vehicular way and the walking surface is not separated by curbs, railings, or other elements between the pedestrian areas and vehicular areas, the boundary between the areas is not defined by a continuous detectable warning at least 36” wide complying with CBC 1121B.3.1 item 8(a). (i.e., the warning surface shall contrast visually with adjoining surfaces, either light on dark or dark on light, and shall differ from adjoining walking surfaces in resiliency or sound on cane contact. Color: yellow conforming to Federal Color No. 33538, Table IV/ Standard No. 595B. Where the color value contrast between the yellow warning and the main walking surface is less than 70 percent, a 1" wide black strip shall separate the yellow warning from the main walking surface.) 4.29.5 705.1 1133B.8 .5 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 180 Parking Lot 03B.10 - Running Slope Slope of the accessible route of travel exceeds 1:20. 4.3.7 403.3 1133B.7 .3 -5.2%.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 187 Storage Room 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -3.25 to 5.2% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 188 School Grounds 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.5%.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 189 School Grounds 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.2% to 2.3% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 190 School Grounds Page 70 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -4.5%.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 191 School Grounds 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.3% to 3.7% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 192 School Grounds 03B.21 - Hazardous Vehicular Areas - Detectable Warnings Where a walk crosses or adjoins the vehicular way and the walking surface is not separated by curbs, railings, or other elements between the pedestrian areas and vehicular areas, the boundary between the areas is not defined by a continuous detectable warning at least 36” wide complying with CBC 1121B.3.1 item 8(a). (i.e., the warning surface shall contrast visually with adjoining surfaces, either light on dark or dark on light, and shall differ from adjoining walking surfaces in resiliency or sound on cane contact. Color: yellow conforming to Federal Color No. 33538, Table IV/ Standard No. 595B. Where the color value contrast between the yellow warning and the main walking surface is less than 70 percent, a 1" wide black strip shall separate the yellow warning from the main walking surface.) 4.29.5 705.1 1133B.8 .5 -PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 193 School Grounds 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -3.0%.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 194 School Grounds 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.5% to 3.7% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 196 School Grounds Page 71 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.13 - > 1/2" Changes in Level Curb ramps, ramps, or elevators are not used for changes in level greater than 1/2 inch. (Lifts may only be used in certain limited situations.) 4.5.2 303.4 1124B.2 -1/2" level change.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 197 School Grounds 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -3.3% at irrigation valve.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 198 School Grounds 03B.15 - Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Uneven surface.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 199 School Grounds 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.5% to 4.8% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 200 School Grounds 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.6% to 7.3% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 201 School Grounds 03B.15 - Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Uneven surface, water accumulates. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 202 School Grounds 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -3.5%.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 203 School Grounds Page 72 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.3%.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 207 School Grounds 03B.02 - Route for General Public Accessible route of travel, to the maximum extent feasible, does not coincide with the route for the general public. (Elements such as ramps, elevators, or other circulation devices, shall be placed to minimize the distance which wheelchair users and other persons who cannot negotiate steps may have to travel compared to the general public.) 4.3.2(1) 206.3; Advisory 206.3 1114B.1 .2 -No POT connects top soccer field to baseball field. PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 208 Top Stairs 03B.02 - Route for General Public Accessible route of travel, to the maximum extent feasible, does not coincide with the route for the general public. (Elements such as ramps, elevators, or other circulation devices, shall be placed to minimize the distance which wheelchair users and other persons who cannot negotiate steps may have to travel compared to the general public.) 4.3.2(1) 206.3; Advisory 206.3 1114B.1 .2 -No POT connects baseball field to paddle tennis courts. PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 209 Middle Stairs 03B.03 - Facilities Connected Accessible routes of travel do not connect all accessible buildings, facilities, elements and spaces on the same site with one another. 4.1.2(2) (a) 206.2.2; Advisory 206.2.2 1114B.1 .2; 1127B.1 -No POT connects paddle tennis courts to school/ community center. PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 210 Bottom Stairs 03B.11 - Ramps This portion of an accessible route with a slope greater than 5% does not comply with the requirements for compliant ramps. 4.8.1 405 1133B.5 -5.7% slope.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 797 Restrooms 50Number of Key Notes for Group 03B - On-Site Path of Travel: Page 73 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 01 - Parking Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 01.23 - Other - Parking See Additional Comments ---Tire stop adjacent to access aisle. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 178 Parking Lot 01.10B - Van Access Aisle - Location Where the parking space is designated as "van accessible," the adjacent access aisle is not located on the passenger side of the vehicle space. 4.1.2(5) (b) -1129B.3 item 2 Van access aisle not on passenger side. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 179 Parking Lot 01.19A - Lettering The words “NO PARKING” is not provided in each access aisle, painted in white, 12” high letters. --1129B.3 items 1 & 2 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 181 Parking Lot 01.15C - Minimum Fine Sign Accessible parking space has no sign stating "Minimum Fine $250" below the ISA. --1129B.4 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 182 Parking Lot 01.13 - Level Surface The accessible parking spaces and access aisles are not level (slope is greater than 2%). 4.6.3 502.4; advisory 502.4 1129B.3 items 3 & 4 2.5% to 2.6% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 183 Parking Lot 01.19B - Tow- away Sign A California tow-away sign is not posted in a conspicuous place at each entrance to off–street parking lot, or immediately adjacent to and visible from each accessible stall. --1129B.4 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 184 Parking Lot 6Number of Key Notes for Group 01 - Parking: Group 30 - Parks Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation Page 74 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 30 - Parks Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 30.21 - Fixed Bench Size Accessible bench does not have seats that are 20" to 24" in depth and 42" min. in length. OR The back support does not extend from a point 2" maximum above the bench to 18" min. above the bench. -903.3 903.4 Fig. 903.4 --PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 2 View Point 30.06E - Outdoor Recreation Access Route (ORAR) Segment - Cross Slope Cross slope of the access route segment exceeds 3.33%. Exception: Cross slopes of 5% maximum are permitted to ensure proper drainage. ---1999 ADAAG- 16.3.7.1 4.0% to 7.8% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 32 Rest Area 30.05 - Accessible Route - Width Accessible route of travel is less than 48” wide (note: 48" wide requirement does not apply to doorways or gates). 4.3.3 403.5.1 1133B.7 .1 -44" clear width.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 33 Rest Area 30.68 - Other - Parks See Additional Comments ----3" step at end of POT.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 34 Rest Area 30.05 - Accessible Route - Width Accessible route of travel is less than 48” wide (note: 48" wide requirement does not apply to doorways or gates). 4.3.3 403.5.1 1133B.7 .1 -30" clear width at step.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 35 Rest Area 30.06C - Outdoor Recreation Access Route (ORAR) Surface The surface of the access route is not firm or stable. ---1999 ADAAG- 16.3.1 Loose gravel.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 36 Rest Area Page 75 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 30 - Parks Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 30.16 - Fixed Bench / Wheelchair Seating Space - Shoulder Alignment A clear space at least 30" x 48" in size has not been provided at one end of the fixed bench so that a wheelchair user may be seated shoulder- to-shoulder with an individual seated on the bench. ---1999 ADAAG- 16.12.4 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 37 Rest Area 30.12 - Fixed Bench Fixed bench is not accessible for users with various types of disabilities. -903.1 -1999 ADAAG- 16.12.2. 1 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 38 Rest Area 30.04 - Accessible Route - Facilities Connected Accessible routes of travel do not connect all accessible buildings, facilities, elements and spaces on the same site with one another. 4.1.2(2) (a) 206.2.2; Advisory 206.2.2 1114B.1 .2; 1127B.1 -No POT connecting to dugout.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 72 Baseball Field 30.19 - Fixed Bench Height The height of the front edge of the seating surface is not between 17" and 19" above the adjacent grade or floor space. -903.5 -1999 ADAAG- 16.12.3 16 1/4" high.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 73 Baseball Field 30.16 - Fixed Bench / Wheelchair Seating Space - Shoulder Alignment A clear space at least 30" x 48" in size has not been provided at one end of the fixed bench so that a wheelchair user may be seated shoulder- to-shoulder with an individual seated on the bench. ---1999 ADAAG- 16.12.4 No WC seating space.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 74 Baseball Field 30.20 - Fixed Bench - Back Support Back support is not provided along the full length of the accessible bench. -903.4 -1999 ADAAG- 16.12.5 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 75 Baseball Field Page 76 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 30 - Parks Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 30.21 - Fixed Bench Size Accessible bench does not have seats that are 20" to 24" in depth and 42" min. in length. OR The back support does not extend from a point 2" maximum above the bench to 18" min. above the bench. -903.3 903.4 Fig. 903.4 --17 1/2" deep.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 76 Baseball Field 30.04 - Accessible Route - Facilities Connected Accessible routes of travel do not connect all accessible buildings, facilities, elements and spaces on the same site with one another. 4.1.2(2) (a) 206.2.2; Advisory 206.2.2 1114B.1 .2; 1127B.1 -No POT to monkey bar.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 77 Baseball Field/ Soccer Field 30.23 - Picnic Sites - Accessible Route Accessible routes do not connect the picnic site to accessible building entrances, accessible site facilities and the accessible entrance to the site. (A picnic site exists wherever one or more picnic tables is located. In general, picnic areas must include accessible parking, restroom, picnic site and routes that connect each of the elements throughout the area.) 4.1.2(2) (a) 206.2.2; Advisory 206.2.2 1127B.1 ; 1132B.2 1999 ADAAG- 16.1 No POT to picnic table.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 78 Baseball Field/ Soccer Field 30.34C - Picnic Table - Knee Space Depth Picnic table does not provide at least 19" depth for accessible knee clearance. 4.32.3 305; 306 1122B.3 1999 ADAAG- 16.5.4 17" deep.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 79 Baseball Field/ Soccer Field 30.29 - Picnic Site Surface Picnic tables and benches are not on a firm and stable surface. ---1999 ADAAG- 16.5.6 Muddy surface around picnic table. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 80 Baseball Field/ Soccer Field Page 77 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 30 - Parks Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 30.04 - Accessible Route - Facilities Connected Accessible routes of travel do not connect all accessible buildings, facilities, elements and spaces on the same site with one another. 4.1.2(2) (a) 206.2.2; Advisory 206.2.2 1114B.1 .2; 1127B.1 -No POT to dog waste bag dispenser. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 81 Baseball Field/ Soccer Field 30.04 - Accessible Route - Facilities Connected Accessible routes of travel do not connect all accessible buildings, facilities, elements and spaces on the same site with one another. 4.1.2(2) (a) 206.2.2; Advisory 206.2.2 1114B.1 .2; 1127B.1 -No POT connects to paddle tennis courts. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 94 Paddle Tennis Courts 30.15 - Fixed Bench - Ground/Floor Surface The surface around the accessible bench is not firm or stable. ---1999 ADAAG- 16.12.6 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 99 Paddle Tennis Courts 30.16 - Fixed Bench / Wheelchair Seating Space - Shoulder Alignment A clear space at least 30" x 48" in size has not been provided at one end of the fixed bench so that a wheelchair user may be seated shoulder- to-shoulder with an individual seated on the bench. ---1999 ADAAG- 16.12.4 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 100 Paddle Tennis Courts 30.19 - Fixed Bench Height The height of the front edge of the seating surface is not between 17" and 19" above the adjacent grade or floor space. -903.5 -1999 ADAAG- 16.12.3 16" high.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 101 Paddle Tennis Courts 30.22 - Fixed Bench Armrest Less than 50% of the fixed benches required to be accessible have at least one armrest that can withstand 250 lbs. of force in any direction. 4.26.3 903.6 1115B.7 .2 1999 ADAAG- 16.12.2. 2; 16.12.8 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 102 Paddle Tennis Courts Page 78 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 30 - Parks Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 30.21 - Fixed Bench Size Accessible bench does not have seats that are 20" to 24" in depth and 42" min. in length. OR The back support does not extend from a point 2" maximum above the bench to 18" min. above the bench. -903.3 903.4 Fig. 903.4 --10" deep, back support extends 14 1/2" high and 5" from edge of seat. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 103 Paddle Tennis Courts 30.23 - Picnic Sites - Accessible Route Accessible routes do not connect the picnic site to accessible building entrances, accessible site facilities and the accessible entrance to the site. (A picnic site exists wherever one or more picnic tables is located. In general, picnic areas must include accessible parking, restroom, picnic site and routes that connect each of the elements throughout the area.) 4.1.2(2) (a) 206.2.2; Advisory 206.2.2 1127B.1 ; 1132B.2 1999 ADAAG- 16.1 No POT connects to picnic table. PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 104 Paddle Tennis Courts 30.29 - Picnic Site Surface Picnic tables and benches are not on a firm and stable surface. ---1999 ADAAG- 16.5.6 Mulch around picnic area.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 105 Paddle Tennis Courts 30.34C - Picnic Table - Knee Space Depth Picnic table does not provide at least 19" depth for accessible knee clearance. 4.32.3 305; 306 1122B.3 1999 ADAAG- 16.5.4 17" deep.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 106 Paddle Tennis Courts Page 79 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 30 - Parks Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 30.25 - Number - Accessible Picnic Tables Where fixed picnic tables are provided in a picnic area, the required number of fixed picnic tables is not provided. (1999 ADAAG: Where two or more fixed picnic tables are provided in a picnic area, at least 50%, but never less than two, shall comply with 16.5.4 through 16.5.6. In addition, at least 40%, but never less than two, of the accessible picnic tables shall be connected to an outdoor recreation access route complying with 16.3.) ---1999 ADAAG- 16.5.1.2 2 picnic tables, 0 accessible.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 107 Paddle Tennis Courts 30.32 - 36" Aisle Width Standard Around the picnic table, there is less than 36" clear space measured from the seat. ---1999 ADAAG- 16.5.5 20" to 27" aisle with around picnic table. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 127 School Grounds 30.23 - Picnic Sites - Accessible Route Accessible routes do not connect the picnic site to accessible building entrances, accessible site facilities and the accessible entrance to the site. (A picnic site exists wherever one or more picnic tables is located. In general, picnic areas must include accessible parking, restroom, picnic site and routes that connect each of the elements throughout the area.) 4.1.2(2) (a) 206.2.2; Advisory 206.2.2 1127B.1 ; 1132B.2 1999 ADAAG- 16.1 No POT connects to picnic tables. PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 149 Basketball Courts 30.25 - Number - Accessible Picnic Tables Where fixed picnic tables are provided in a picnic area, the required number of fixed picnic tables is not provided. (1999 ADAAG: Where two or more fixed picnic tables are provided in a picnic area, at least 50%, but never less than two, shall comply with 16.5.4 through 16.5.6. In addition, at least 40%, but never less than two, of the accessible picnic tables shall be connected to an outdoor recreation access route complying with 16.3.) ---1999 ADAAG- 16.5.1.2 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 150 Basketball Courts Page 80 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 30 - Parks Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 30.29 - Picnic Site Surface Picnic tables and benches are not on a firm and stable surface. ---1999 ADAAG- 16.5.6 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 151 Basketball Courts 32Number of Key Notes for Group 30 - Parks: Group 31 - Play Areas Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 31.37A - Soft Contained Play Structures - 1 Entry Point Standard Where three or fewer entry points are provided, there is not at least one entry point located on an accessible route. -206.2.1 7.2 -2000 ADAAG- 15.6.8.1 PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 109 Playground 31.22A - Transfer Platforms - Transfer Space Size Transfer space provided at the transfer platform is less than 30” x 48” min.. -1008.3. 1.3 -2000 ADAAG- 15.6.5.1 .3 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 110 Playground 31.14 - Play Area Ramp Standards This portion of an accessible route with a slope greater than 5% (1:20) does not comply with the requirements for compliant ramps. (Ramps within play areas, ramps connecting ground level play components, and ramps connecting elevated play components shall comply with 1008.2.5 and 15.6.4.4.) -1008.2. 5 -2000 ADAAG- 15.6.4.4 9.3%GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 145 Playground 31.38 - Other - Play Areas See Additional Comments ----Level change at transition from rubber surface to sand. GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 146 Playground Page 81 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 31 - Play Areas Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 31.34 - Play Areas - Ground Surfaces Ground surfaces along accessible routes, clear floor or ground spaces, or turning spaces are not compliant. -1008.2. 6 -2000 ADAAG- 15.6.7; PRC 5410- 5411; H&SC 115725 No rubber surface at swing.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 147 Playground 31.10 - Accessible Routes - Location Accessible routes required within the boundary of play area do not connect ground level play components and elevated components, including entry and exit points. -1008.2 -2000 ADAAG- 15.6.4.1 Playground entry point not connected to swings. GS - General Student Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 148 Playground 31.38 - Other - Play Areas See Additional Comments ----Transition from grass to playground and asphalt is greater than 1/2". GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 592 Playground 31.38 - Other - Play Areas See Additional Comments ----No WC accessible picnic table.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 593 Playground 8Number of Key Notes for Group 31 - Play Areas: Group 03A - Public Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03A.01A - Accessible Route of Travel (Public ROW) Accessible route of travel linking an accessible site entrance with accessible feature(s) adjacent to the property line of the site (e.g.. public transportation stops; passenger loading zones; accessible parking, and public sidewalks) is not accessible. ---2005 PROWA G-R204 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 1 View Point Page 82 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03A - Public Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03A.07A - Cross Slope (PAR) Cross slope of the pedestrian access route exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 2005 PROWA G- R301.4. 1 2.4% to 3.5% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 3 Sidewalk 03A.15 - Other - Pedestrian Accessible Route (Public Right of Way) See Additional Comments ----Shrubs obstruct sidewalk.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 4 Sidewalk 03A.07B - Cross Slope - Driveway (PAR) Cross slope of the pedestrian access route in a driveway exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 2005 PROWA G- R301.4. 1 10%.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 5 Sidewalk 03A.14A - Walk Bordering Vehicular Way - Detectable Warnings Where a walk crosses or adjoins the vehicular way and the walking surface is not separated by curbs, railings, or other elements between the pedestrian areas and vehicular areas, the boundary between the areas is not defined by a continuous detectable warning at least 36” wide complying with CBC 1121B.3.1 item 8(a). (i.e., the warning surface shall contrast visually with adjoining surfaces, either light on dark or dark on light, and shall differ from adjoining walking surfaces in resiliency or sound on cane contact. Color: yellow conforming to Federal Color No. 33538, Table IV/ Standard No. 595B. Where the color value contrast between the yellow warning and the main walking surface is less than 70 percent, a 1" wide black strip shall separate the yellow warning from the main walking surface.) 4.29.5 705 1133B.8 .5 2005 PROWA G- R303.3. 2 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 6 Sidewalk Page 83 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03A - Public Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03A.15 - Other - Pedestrian Accessible Route (Public Right of Way) See Additional Comments ----1" gap.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 7 Sidewalk 03A.07A - Cross Slope (PAR) Cross slope of the pedestrian access route exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 2005 PROWA G- R301.4. 1 2.2% to 5.0% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 8 Sidewalk 03A.09 - > 1/4" Changes in Level Where walkway levels change abruptly, the vertical difference between them exceed 1/4 inch. OR Changes in level between 1/4 inch and 1/2 inch are beveled with a slope greater than 1:2. 4.5.2 303.2; 303.3 1124B.2 2005 PROWA G- R301.5. 2 1/2" level change.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 9 Sidewalk 03A.07A - Cross Slope (PAR) Cross slope of the pedestrian access route exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 2005 PROWA G- R301.4. 1 2.5% to 4.9% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 10 Sidewalk 03A.07A - Cross Slope (PAR) Cross slope of the pedestrian access route exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 2005 PROWA G- R301.4. 1 2.2% to 4.5% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 11 Sidewalk 03A.07A - Cross Slope (PAR) Cross slope of the pedestrian access route exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 2005 PROWA G- R301.4. 1 2.2% to 4.6% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 12 Sidewalk Page 84 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03A - Public Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03A.08 - Running Slope (PAR) Slope of the pedestrian access route exceeds 1:20. Or slope of the pedestrian access route contained within a street or highway border exceeds the grade of the adjacent roadway. (1:20 requirement does not apply to compliant ramps or where slope of the pedestrian access route contained within a street or highway border does not exceed the grade of the adjacent roadway.) 4.3.7 403.3 1133B.7 .3 2005 PROWA G- R301.4. 2 11.3%.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 13 Sidewalk 03A.09 - > 1/4" Changes in Level Where walkway levels change abruptly, the vertical difference between them exceed 1/4 inch. OR Changes in level between 1/4 inch and 1/2 inch are beveled with a slope greater than 1:2. 4.5.2 303.2; 303.3 1124B.2 2005 PROWA G- R301.5. 2 Greater than 1 1/2" level change at transition from driveway to sidewalk at both side of driveway. PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 14 Sidewalk 03A.07B - Cross Slope - Driveway (PAR) Cross slope of the pedestrian access route in a driveway exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 2005 PROWA G- R301.4. 1 6.3% to 8.1% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 15 Sidewalk 03A.07A - Cross Slope (PAR) Cross slope of the pedestrian access route exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 2005 PROWA G- R301.4. 1 2.3% to 4.4% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 16 Sidewalk 03A.09 - > 1/4" Changes in Level Where walkway levels change abruptly, the vertical difference between them exceed 1/4 inch. OR Changes in level between 1/4 inch and 1/2 inch are beveled with a slope greater than 1:2. 4.5.2 303.2; 303.3 1124B.2 2005 PROWA G- R301.5. 2 1/2" level change.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 17 Sidewalk Page 85 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03A - Public Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03A.07A - Cross Slope (PAR) Cross slope of the pedestrian access route exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 2005 PROWA G- R301.4. 1 2.2% to 5.9% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 18 Sidewalk 03A.02B - Passing Spaces Where the accessible route of travel is less than 60” wide, passing spaces at least 60” by 60” or intersecting walks, allowing passing at reasonable intervals not exceeding 200’, is not provided. 4.3.4 403.5.3 1133B.7 .1 2005 PROWA G- R301.3. 2 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 19 Sidewalk 03A.08 - Running Slope (PAR) Slope of the pedestrian access route exceeds 1:20. Or slope of the pedestrian access route contained within a street or highway border exceeds the grade of the adjacent roadway. (1:20 requirement does not apply to compliant ramps or where slope of the pedestrian access route contained within a street or highway border does not exceed the grade of the adjacent roadway.) 4.3.7 403.3 1133B.7 .3 2005 PROWA G- R301.4. 2 5.2% to 8.1% RS on sidewalk; does not follow RS on road. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 20 Sidewalk 03A.06B - Clear Width - Free Standing Protruding Objects Free standing object(s) mounted on posts with leading edges between 27" and 80” high (such as a sign or telephone) projects into the circulation path and does not maintains the required clear width of the accessible route. 4.4.1 307.3 1133B.8 .6.1 2005 PROWA G- R401.1 Shrubs obstruct clear width of sidewalk. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 21 Sidewalk 03A.07A - Cross Slope (PAR) Cross slope of the pedestrian access route exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 2005 PROWA G- R301.4. 1 2.1% to 3.9% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 22 Sidewalk Page 86 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03A - Public Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03A.08 - Running Slope (PAR) Slope of the pedestrian access route exceeds 1:20. Or slope of the pedestrian access route contained within a street or highway border exceeds the grade of the adjacent roadway. (1:20 requirement does not apply to compliant ramps or where slope of the pedestrian access route contained within a street or highway border does not exceed the grade of the adjacent roadway.) 4.3.7 403.3 1133B.7 .3 2005 PROWA G- R301.4. 2 5.1% to 8.4% RS on sidewalk does not follow RS on road. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 23 Sidewalk 03A.07A - Cross Slope (PAR) Cross slope of the pedestrian access route exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 2005 PROWA G- R301.4. 1 2.4% to 4.5% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 24 Sidewalk 03A.08 - Running Slope (PAR) Slope of the pedestrian access route exceeds 1:20. Or slope of the pedestrian access route contained within a street or highway border exceeds the grade of the adjacent roadway. (1:20 requirement does not apply to compliant ramps or where slope of the pedestrian access route contained within a street or highway border does not exceed the grade of the adjacent roadway.) 4.3.7 403.3 1133B.7 .3 2005 PROWA G- R301.4. 2 5.6% to 9.4% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 25 Sidewalk 03A.07B - Cross Slope - Driveway (PAR) Cross slope of the pedestrian access route in a driveway exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 2005 PROWA G- R301.4. 1 6.5% to 7.3% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 39 Driveway Page 87 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03A - Public Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03A.14A - Walk Bordering Vehicular Way - Detectable Warnings Where a walk crosses or adjoins the vehicular way and the walking surface is not separated by curbs, railings, or other elements between the pedestrian areas and vehicular areas, the boundary between the areas is not defined by a continuous detectable warning at least 36” wide complying with CBC 1121B.3.1 item 8(a). (i.e., the warning surface shall contrast visually with adjoining surfaces, either light on dark or dark on light, and shall differ from adjoining walking surfaces in resiliency or sound on cane contact. Color: yellow conforming to Federal Color No. 33538, Table IV/ Standard No. 595B. Where the color value contrast between the yellow warning and the main walking surface is less than 70 percent, a 1" wide black strip shall separate the yellow warning from the main walking surface.) 4.29.5 705 1133B.8 .5 2005 PROWA G- R303.3. 2 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 40 Driveway 03A.07A - Cross Slope (PAR) Cross slope of the pedestrian access route exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 2005 PROWA G- R301.4. 1 2.2% to 6.1% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 41 Sidewalk 03A.08 - Running Slope (PAR) Slope of the pedestrian access route exceeds 1:20. Or slope of the pedestrian access route contained within a street or highway border exceeds the grade of the adjacent roadway. (1:20 requirement does not apply to compliant ramps or where slope of the pedestrian access route contained within a street or highway border does not exceed the grade of the adjacent roadway.) 4.3.7 403.3 1133B.7 .3 2005 PROWA G- R301.4. 2 8.8% at transition point.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 42 Sidewalk Page 88 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03A - Public Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03A.10 - Changes in Level (Curb Ramps or Ramps) Curb ramp(s) and ramp(s) are not compliant.4.7.1; 4.8.1 405; 406 1127B.5 item 1; 1133B.5 .1 2005 PROWA G- R303.1; R406.1 1 1/2" level change and ramp condition with 21.4% RS for 16" long segment. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 43 Sidewalk 03A.05A - Wall- Mounted Protruding Objects Wall-mounted object(s) with leading edges between 27" and 80” from the floor projects more than 4" into the pathway. (Wall mounted objects with leading edges at or below 27” may project any amount as long as the required clear width of the accessible route of travel is maintained). 4.4.1 307.2 1133B.8 .6.1 2005 PROWA G- R401.2 Shrub maintenance.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 44 Sidewalk 03A.09 - > 1/4" Changes in Level Where walkway levels change abruptly, the vertical difference between them exceed 1/4 inch. OR Changes in level between 1/4 inch and 1/2 inch are beveled with a slope greater than 1:2. 4.5.2 303.2; 303.3 1124B.2 2005 PROWA G- R301.5. 2 1/2" level change.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 45 Sidewalk 03A.07A - Cross Slope (PAR) Cross slope of the pedestrian access route exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 2005 PROWA G- R301.4. 1 2.2% to 3.6% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 46 Sidewalk 03A.08 - Running Slope (PAR) Slope of the pedestrian access route exceeds 1:20. Or slope of the pedestrian access route contained within a street or highway border exceeds the grade of the adjacent roadway. (1:20 requirement does not apply to compliant ramps or where slope of the pedestrian access route contained within a street or highway border does not exceed the grade of the adjacent roadway.) 4.3.7 403.3 1133B.7 .3 2005 PROWA G- R301.4. 2 10.2% to 14.2% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 47 Sidewalk Page 89 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03A - Public Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03A.09 - > 1/4" Changes in Level Where walkway levels change abruptly, the vertical difference between them exceed 1/4 inch. OR Changes in level between 1/4 inch and 1/2 inch are beveled with a slope greater than 1:2. 4.5.2 303.2; 303.3 1124B.2 2005 PROWA G- R301.5. 2 2" level change at transition point from sidewalk to driveway. PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 48 Sidewalk 03A.09 - > 1/4" Changes in Level Where walkway levels change abruptly, the vertical difference between them exceed 1/4 inch. OR Changes in level between 1/4 inch and 1/2 inch are beveled with a slope greater than 1:2. 4.5.2 303.2; 303.3 1124B.2 2005 PROWA G- R301.5. 2 1/2" to 1 1/2" level change.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 49 Sidewalk 03A.07A - Cross Slope (PAR) Cross slope of the pedestrian access route exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 2005 PROWA G- R301.4. 1 2.2% to 7.9% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 50 Sidewalk 03A.07B - Cross Slope - Driveway (PAR) Cross slope of the pedestrian access route in a driveway exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 2005 PROWA G- R301.4. 1 11.3%.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 195 School Grounds 37Number of Key Notes for Group 03A - Public Path of Travel: Group 07 - Ramps Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 07.01A - Ramps This portion of an accessible route with a slope greater than 5% does not comply with the requirements for compliant ramps. 4.8.1 402.2; Advisory 402.2 1133B.5 .1 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 157 Basketball Courts Page 90 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 07 - Ramps Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 07.29 - Other - Ramps See Additional Comments ----3/4" level change at transition from concrete to asphalt. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 158 Basketball Courts 07.02 - Running Slope Slope of the ramp exceeds 8.33% (or the least possible compliant slope). 4.8.2 405.2; Advisory 405.2 1133B.5 .3 -12.4%.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 159 Basketball Courts 07.07A - Level Landings Landings at the top or bottom of each ramp or each ramp run is not level (slope is greater than 2% in some or all directions). 4.8.4 405.7; 405.7.1 1133B.5 .4.1 -6.0% at top landing.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 160 Basketball Courts 07.03 - Maximum Rise The rise for any continuous run exceeds 30” high. 4.8.2 405.6 1133B.5 .4.1 -Greater than 30" with no intermediate landings. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 161 Basketball Courts 07.16 - Handrails Slope of the ramp exceeds 5%, and handrails are not provided on each side. (Per CBC 1133B.5.5.1, at exterior door landings, handrails are not required on ramps less than 6” high or 72” long. Handrails are not required on curb ramps or adjacent to fixed seating in assembly areas.) 4.8.5 405.8; 505.2 1133B.5 .5.1 -None provided.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 162 Basketball Courts 6Number of Key Notes for Group 07 - Ramps: Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation Page 91 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -79" to door frame and closer.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 217 Classroom G 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -65" to heating/cooling control.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 218 Classroom G 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -67" to thermostat.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 219 Classroom G 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -60" to light switch.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 220 Classroom G Page 92 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -76" to gas switch.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 221 Classroom G 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -75" to playground light switch.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 222 Classroom G 14.37 - Kitchen Sink Sink does not provide accessible knee clearance (i.e. at least 27” high, 30” wide, and 19” deep). 4.24.3 305; 306; 606.2 1115B.4 .7(2); 1122B.4 -No knee space.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 223 Classroom G 14.34 - Electrical/Commu nications Receptacles - Mounting Height Electrical/communications receptacle is not located between 15” min.. and 48” max.. AFF. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 308.2.1; Fig. 308.2.1; 308.3.1; Fig. 308.3.1; 309.3 1117B.6 (5.2) -14" high receptacle.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 227 Classroom G 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -79" to door frame and closer.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 236 Classroom G Page 93 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -79" to door frame and closer.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 244 Classroom H 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -65" to heating/cooling control.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 247 Classroom H 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -60" to light switch.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 248 Classroom H 14.37 - Kitchen Sink Sink does not provide accessible knee clearance (i.e. at least 27” high, 30” wide, and 19” deep). 4.24.3 305; 306; 606.2 1115B.4 .7(2); 1122B.4 -No knee space.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 249 Classroom H 14.21B - 36" Width Standard The accessible route of travel is not at least 36” wide where the occupancy load is < 10. (For a depth of 24" max.., clear opening width may be reduced to 32" min..) (Doorways are compliant when the door, open 90 degrees, affords a clear opening width of at least 32”.) 4.3.3; Fig. 7(a)(b) 403.5.1; Fig. 403.5.1 1133B.3 .1 -Furniture.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 251 Classroom H Page 94 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -79" to door frame and closer.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 257 Classroom H 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -79" to door frame and closer.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 266 Classroom 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -60" to light switch.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 268 Classroom 14.37 - Kitchen Sink Sink does not provide accessible knee clearance (i.e. at least 27” high, 30” wide, and 19” deep). 4.24.3 305; 306; 606.2 1115B.4 .7(2); 1122B.4 -No knee space.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 270 Classroom 14.21B - 36" Width Standard The accessible route of travel is not at least 36” wide where the occupancy load is < 10. (For a depth of 24" max.., clear opening width may be reduced to 32" min..) (Doorways are compliant when the door, open 90 degrees, affords a clear opening width of at least 32”.) 4.3.3; Fig. 7(a)(b) 403.5.1; Fig. 403.5.1 1133B.3 .1 -Furniture.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 271 Classroom 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -79" to headroom and closer.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 278 Classroom Page 95 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -79" to door frame and closer.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 283 Classroom K 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -79" to door frame and closer.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 296 Classroom K 14.34 - Electrical/Commu nications Receptacles - Mounting Height Electrical/communications receptacle is not located between 15” min.. and 48” max.. AFF. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 308.2.1; Fig. 308.2.1; 308.3.1; Fig. 308.3.1; 309.3 1117B.6 (5.2) -14" high receptacle.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 299 Classroom K 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -65" to thermostat.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 300 Classroom K 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -60" to light switch.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 301 Classroom K Page 96 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -58" to alarm.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 302 Classroom K 14.37 - Kitchen Sink Sink does not provide accessible knee clearance (i.e. at least 27” high, 30” wide, and 19” deep). 4.24.3 305; 306; 606.2 1115B.4 .7(2); 1122B.4 -No knee space.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 305 Classroom K 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -79" to door frame and closer.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 313 Classroom J 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 323 Classroom J 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -65" to heating/ cooling control.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 324 Classroom J Page 97 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -69" to thermostat.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 325 Classroom J 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -54 1/2" to alarm.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 326 Classroom J 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -60" to light switch.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 327 Classroom J 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -65" to gas switch.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 328 Classroom J Page 98 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.34 - Electrical/Commu nications Receptacles - Mounting Height Electrical/communications receptacle is not located between 15” min.. and 48” max.. AFF. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 308.2.1; Fig. 308.2.1; 308.3.1; Fig. 308.3.1; 309.3 1117B.6 (5.2) -14" high receptacle.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 329 Classroom J 14.37 - Kitchen Sink Sink does not provide accessible knee clearance (i.e. at least 27” high, 30” wide, and 19” deep). 4.24.3 305; 306; 606.2 1115B.4 .7(2); 1122B.4 -No knee space.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 330 Classroom J 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -79" to door frame and closer.GS - General Student Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 338 Montessori Classroom 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -79" to door frame and closer.GS - General Student Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 345 Montessori Classroom 14.36B - Kitchen Counter/Sink Height Where provided in public or common use areas, countertops and sinks are not mounted at 34” AFF. max..(Common use areas are those interior and exterior rooms, spaces, or elements that are made available for the use of a restricted group of people (for example, the occupants of an office building, or the guests of such occupants). 4.24.2 212.3; 606.3 1115B.4 .7(2); 1122B.4 -30 1/2" high, 24" maximum for kindergarten. GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 346 Montessori Classroom 14.37 - Kitchen Sink Sink does not provide accessible knee clearance (i.e. at least 27” high, 30” wide, and 19” deep). 4.24.3 305; 306; 606.2 1115B.4 .7(2); 1122B.4 -No knee space.GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 347 Montessori Classroom Page 99 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Loose floor mats.GS - General Student Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 348 Montessori Classroom 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -59" to light switch.GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 349 Montessori Classroom 14.26 - Floor Material Changes Where floor materials change, the vertical difference between them is not compliant. (Vertical difference shall be < 1/4". Changes in level between 1/4 inch and 1/2 inch shall be beveled with a slope no greater than 1:2.) 4.1.3(5) ; 4.5.2 303.2; 303.3 1124B.1 -3/4" level change tile to carpet.GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 350 Montessori Classroom 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -59" to gas switch.GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 352 Montessori Classroom 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -55" to phone.GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 353 Montessori Classroom Page 100 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -66" to thermostat.GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 354 Montessori Classroom 14.02 - Accessible Route Accessible routes of travel do not connect the room or space to an accessible entrance within the building or facility. 4.1.3(1) ; 4.3.2(3) 206.2.4; Advisory 206.2.4 1114B.1 .2 -7" step from door landing to patio. GS - General Student Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 356 Montessori Classroom 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -79" to door frame and closer.GS - General Student Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 366 Classroom F 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -79" to door frame and closer.GS - General Student Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 378 Classroom F 14.26 - Floor Material Changes Where floor materials change, the vertical difference between them is not compliant. (Vertical difference shall be < 1/4". Changes in level between 1/4 inch and 1/2 inch shall be beveled with a slope no greater than 1:2.) 4.1.3(5) ; 4.5.2 303.2; 303.3 1124B.1 -3/4" level change from tile to carpet. GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 379 Classroom F Page 101 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.36B - Kitchen Counter/Sink Height Where provided in public or common use areas, countertops and sinks are not mounted at 34” AFF. max..(Common use areas are those interior and exterior rooms, spaces, or elements that are made available for the use of a restricted group of people (for example, the occupants of an office building, or the guests of such occupants). 4.24.2 212.3; 606.3 1115B.4 .7(2); 1122B.4 -30 1/2" high, 24" maximum for kindergarten. GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 380 Classroom F 14.37 - Kitchen Sink Sink does not provide accessible knee clearance (i.e. at least 27” high, 30” wide, and 19” deep). 4.24.3 305; 306; 606.2 1115B.4 .7(2); 1122B.4 -No knee space.GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 381 Classroom F 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -67" high cupboard, projects 16" from wall. GS - General Student Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 382 Classroom F 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Loose floor mats.GS - General Student Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 383 Classroom F 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -58" to phone.GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 386 Classroom F 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -60" to diaper dispenser.GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 387 Classroom F Page 102 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.34 - Electrical/Commu nications Receptacles - Mounting Height Electrical/communications receptacle is not located between 15” min.. and 48” max.. AFF. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 308.2.1; Fig. 308.2.1; 308.3.1; Fig. 308.3.1; 309.3 1117B.6 (5.2) -60" to light switch.GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 388 Classroom F 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -69 3/4" to door frame.GS - General Student Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 394 Classroom F 14.02 - Accessible Route Accessible routes of travel do not connect the room or space to an accessible entrance within the building or facility. 4.1.3(1) ; 4.3.2(3) 206.2.4; Advisory 206.2.4 1114B.1 .2 -5" level change from door threshold to patio. GS - General Student Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 401 Classroom F 14.02 - Accessible Route Accessible routes of travel do not connect the room or space to an accessible entrance within the building or facility. 4.1.3(1) ; 4.3.2(3) 206.2.4; Advisory 206.2.4 1114B.1 .2 -7" level change from door to patio. GS - General Student Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 403 Classroom E 14.36B - Kitchen Counter/Sink Height Where provided in public or common use areas, countertops and sinks are not mounted at 34” AFF. max..(Common use areas are those interior and exterior rooms, spaces, or elements that are made available for the use of a restricted group of people (for example, the occupants of an office building, or the guests of such occupants). 4.24.2 212.3; 606.3 1115B.4 .7(2); 1122B.4 -30" high, 24" maximum for kindergarten. GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 410 Classroom E 14.37 - Kitchen Sink Sink does not provide accessible knee clearance (i.e. at least 27” high, 30” wide, and 19” deep). 4.24.3 305; 306; 606.2 1115B.4 .7(2); 1122B.4 -No knee space.GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 411 Classroom E Page 103 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -56" to phone.GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 412 Classroom E 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -65 1/2" to heating/ cooling control. GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 413 Classroom E 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -68" to thermostat.GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 414 Classroom E 14.34 - Electrical/Commu nications Receptacles - Mounting Height Electrical/communications receptacle is not located between 15” min.. and 48” max.. AFF. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 308.2.1; Fig. 308.2.1; 308.3.1; Fig. 308.3.1; 309.3 1117B.6 (5.2) -60" to light switch.GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 415 Classroom E Page 104 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Loose floor mats.GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 417 Classroom E 14.02 - Accessible Route Accessible routes of travel do not connect the room or space to an accessible entrance within the building or facility. 4.1.3(1) ; 4.3.2(3) 206.2.4; Advisory 206.2.4 1114B.1 .2 -7" level change from door to patio. GS - General Student Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 419 Classroom E 14.26 - Floor Material Changes Where floor materials change, the vertical difference between them is not compliant. (Vertical difference shall be < 1/4". Changes in level between 1/4 inch and 1/2 inch shall be beveled with a slope no greater than 1:2.) 4.1.3(5) ; 4.5.2 303.2; 303.3 1124B.1 -5/8" level change from tile to carpet. GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 426 Classroom E 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -66" to thermostat.GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 429 Classroom E - Restrooms 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -71" to door frame.GS - General Student Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 437 Classroom E - Restrooms 14.37 - Kitchen Sink Sink does not provide accessible knee clearance (i.e. at least 27” high, 30” wide, and 19” deep). 4.24.3 305; 306; 606.2 1115B.4 .7(2); 1122B.4 -No knee space.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 440 Office Page 105 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -60" to light switch.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 441 Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Card swipe at 64" high over obstruction. PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 443 Office 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Loose floor mats.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 444 Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -65" to heating/cooling control.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 445 Office Page 106 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -62" to alarm.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 446 Office 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -79" to door frame and closer.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 463 Office 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -79" to door frame.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 471 Office 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -79" to door frame.GS - General Student Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 480 Classroom E 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -GS - General Student Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 483 Classroom E 14.26 - Floor Material Changes Where floor materials change, the vertical difference between them is not compliant. (Vertical difference shall be < 1/4". Changes in level between 1/4 inch and 1/2 inch shall be beveled with a slope no greater than 1:2.) 4.1.3(5) ; 4.5.2 303.2; 303.3 1124B.1 -5/8" level change from tile to carpet. GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 484 Classroom E Page 107 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -79" to door frame.GS - General Student Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 489 Classroom E 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Loose floor mat.GS - General Student Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 490 Classroom E 14.26 - Floor Material Changes Where floor materials change, the vertical difference between them is not compliant. (Vertical difference shall be < 1/4". Changes in level between 1/4 inch and 1/2 inch shall be beveled with a slope no greater than 1:2.) 4.1.3(5) ; 4.5.2 303.2; 303.3 1124B.1 -5/8" level change from tile to carpet. GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 492 Classroom E 14.22 - U-Turn Where the accessible route of travel makes a U- turn around an obstacle which is less than 48” wide, the pathway width does not increase to at least 42” on the approaches or 48” in the turn. 4.3.3; Fig. 7(b) 403.5.2; Fig. 403.5.2 Fig 11B- 5E -38" on approach, 37" at turn.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 502 Men's Restroom 14.34 - Electrical/Commu nications Receptacles - Mounting Height Electrical/communications receptacle is not located between 15” min.. and 48” max.. AFF. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 308.2.1; Fig. 308.2.1; 308.3.1; Fig. 308.3.1; 309.3 1117B.6 (5.2) -12" to outlet.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 527 Men's Restroom 14.22 - U-Turn Where the accessible route of travel makes a U- turn around an obstacle which is less than 48” wide, the pathway width does not increase to at least 42” on the approaches or 48” in the turn. 4.3.3; Fig. 7(b) 403.5.2; Fig. 403.5.2 Fig 11B- 5E -36" at turn, 39 1/2" at approach. PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 538 Women's Restroom Page 108 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.34 - Electrical/Commu nications Receptacles - Mounting Height Electrical/communications receptacle is not located between 15” min.. and 48” max.. AFF. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 308.2.1; Fig. 308.2.1; 308.3.1; Fig. 308.3.1; 309.3 1117B.6 (5.2) -12" outlet.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 564 Women's Restroom 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -79" to door frame.GS - General Student Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 571 Classroom A 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -79" to door frame.GS - General Student Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 579 Classroom A 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Loose floor mats.GS - General Student Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 595 Classroom A 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -76" high thermostat.GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 598 Classroom A 14.26 - Floor Material Changes Where floor materials change, the vertical difference between them is not compliant. (Vertical difference shall be < 1/4". Changes in level between 1/4 inch and 1/2 inch shall be beveled with a slope no greater than 1:2.) 4.1.3(5) ; 4.5.2 303.2; 303.3 1124B.1 -3/4" level change from tile to carpet. GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 599 Classroom A Page 109 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -65" to heating/ cooling control.GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 600 Classroom A 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -62" light switch.GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 602 Classroom A 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -70" to alarm panel.GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 605 Classroom A 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Wall cabinet not within reach range. GS - General Student Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 606 Classroom A - Restroom Page 110 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Loose floor mat.GS - General Student Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 610 Classroom A - Restroom 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -74" to closer.GS - General Student Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 632 Children's Restroom 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -74" to closer.EC - Employee Common Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 652 Faculty Restroom 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -14" high receptacle.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 662 Multi- purpose Room 14.37 - Kitchen Sink Sink does not provide accessible knee clearance (i.e. at least 27” high, 30” wide, and 19” deep). 4.24.3 305; 306; 606.2 1115B.4 .7(2); 1122B.4 -No knee space.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 663 Multi- purpose Room 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -65" to heating/ cooling controls. PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 665 Multi- purpose Room Page 111 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -79" to electrical switch.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 666 Multi- purpose Room 14.30A - Wall- Mounted Protruding Objects Wall-mounted object(s) with leading edges between 27 and 80” from the floor project more than 4" into the pathway. (Wall mounted objects with leading edges at or below 27” may project any amount as long as the required clear width of an accessible route is not reduced.) 4.4.1 307.2; Fig. 307.2 1133B.8 .6.1 -5" protrusion a t 71" high.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 667 Multi- purpose Room 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -88" to pull screen.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 669 Multi- purpose Room 14.30A - Wall- Mounted Protruding Objects Wall-mounted object(s) with leading edges between 27 and 80” from the floor project more than 4" into the pathway. (Wall mounted objects with leading edges at or below 27” may project any amount as long as the required clear width of an accessible route is not reduced.) 4.4.1 307.2; Fig. 307.2 1133B.8 .6.1 -FE protrudes 6" at 48" high.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 671 Multi- purpose Room Page 112 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -60" to outlet.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 672 Multi- purpose Room 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -63" to thermostat.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 673 Multi- purpose Room 14.28 - Fixed/Built-in Seating, Tables or Counters At fixed or built-in seating, tables, or counters in public or common employee areas, less than 5% of the provided seating spaces are wheelchair accessible and have a 30” by 48” clear space which overlaps an accessible route of travel. (Wheelchair accessible seating spaces are between 28" - 34" high and with knee space measuring at least 27" high, 30" wide, and 19" deep.) (These elements include study carrels and student laboratory stations.) 4.1.3(18 ); 4.32.1; 4.32.4 226.1; Advisory 226.1; 305; 306; 902.2 1122B.1 -36" high.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 676 Multi- purpose Room 14.29C - Counter - Knee Space Depth Where seating for persons in wheelchairs is provided at table or counter, knee space is less than 19" deep. 4.32.3 306.3.2; Fig. 306.3 1122B.3 ; Fig. 11B-13 -7 1/2".PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 677 Multi- purpose Room Page 113 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.36A - Counter Height Where provided in public or common use areas, countertops are not between 28" - 34” high. (Common use areas are those interior and exterior rooms, spaces, or elements that are made available for the use of a restricted group of people (for example, the occupants of an office building, or the guests of such occupants). 4.32.4 902.3 1122B.4 -36" high.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 682 Kitchen 14.36B - Kitchen Counter/Sink Height Where provided in public or common use areas, countertops and sinks are not mounted at 34” AFF. max..(Common use areas are those interior and exterior rooms, spaces, or elements that are made available for the use of a restricted group of people (for example, the occupants of an office building, or the guests of such occupants). 4.24.2 212.3; 606.3 1115B.4 .7(2); 1122B.4 -36" high.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 683 Kitchen 14.37 - Kitchen Sink Sink does not provide accessible knee clearance (i.e. at least 27” high, 30” wide, and 19” deep). 4.24.3 305; 306; 606.2 1115B.4 .7(2); 1122B.4 -EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 684 Kitchen 14.50 - Other - Rooms and Spaces See Additional Comments ----Roll-up gate over counter at 37" high, 19 LBF Operating force. EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 687 Kitchen 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -First Aid Kit at 65" high.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 715 Office Page 114 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -60" alarm.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 728 Discovery Room 14.34 - Electrical/Commu nications Receptacles - Mounting Height Electrical/communications receptacle is not located between 15” min.. and 48” max.. AFF. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 308.2.1; Fig. 308.2.1; 308.3.1; Fig. 308.3.1; 309.3 1117B.6 (5.2) -57" high receptacle.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 729 Discovery Room 14.34 - Electrical/Commu nications Receptacles - Mounting Height Electrical/communications receptacle is not located between 15” min.. and 48” max.. AFF. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 308.2.1; Fig. 308.2.1; 308.3.1; Fig. 308.3.1; 309.3 1117B.6 (5.2) -13" high receptacle.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 730 Discovery Room 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -67" vending machine.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 732 Office Page 115 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Fire alarm switch at 53" high.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 733 Office 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 734 Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -64" thermostat.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 735 Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -66" key box.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 736 Office Page 116 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -55" light switch.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 737 Office 14.28 - Fixed/Built-in Seating, Tables or Counters At fixed or built-in seating, tables, or counters in public or common employee areas, less than 5% of the provided seating spaces are wheelchair accessible and have a 30” by 48” clear space which overlaps an accessible route of travel. (Wheelchair accessible seating spaces are between 28" - 34" high and with knee space measuring at least 27" high, 30" wide, and 19" deep.) (These elements include study carrels and student laboratory stations.) 4.1.3(18 ); 4.32.1; 4.32.4 226.1; Advisory 226.1; 305; 306; 902.2 1122B.1 -Desk not accessible to public.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 739 Office 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -79" to door frame.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 747 Office 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -79" to door frame.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 756 Discovery Room 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -79" to door frame.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 765 Multi- purpose Room Page 117 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -79" to door frame.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 774 Multi- purpose Room 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -79" to door frame.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 785 Multi- purpose Room 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -79" to door frame.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 796 Multi- purpose Room 133Number of Key Notes for Group 14 - Rooms and Spaces: Group 08 - Stairs Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 08.15 - Landing Size Landing depth in the direction of travel is not at least equal to the width of the stairway. --1009.4 -Top and bottom landings 4'-10" x 48". Intermediate landings 4'- 10" x 44". PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 62 Top Stairs 08.03D - Level Landing Landing is not level (slope is greater than 2% in some or all directions). --1009.5. 1 -3.3% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 63 Top Stairs 08.05A - Exterior Stairs - Color Strip Contrasting color strips have not been provided. --1133B.4 .4 -No stripes.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 64 Top Stairs Page 118 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 08 - Stairs Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 08.10A - Profile of Handrails The diameter of the handrail is not between 1- 1/4” and 1-1/2” in cross-sectional nomin.al dimension. OR The shape does not provide an equivalent gripping surface (equivalent gripping surfaces are 4” to 6-1/4” in perimeter, and 2- 1/4" max.. in any direction). (Note: Standard pipe sizes designated by the industry as 1-1/4” to 1-1/2” are acceptable). 4.9.4; 4.26.2 505.7.1; 505.7.2; Fig. 505.7.2 1133B.4 .2.6 -2".PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 65 Top Stairs 08.02B - Riser Height The risers are not uniform. OR The risers are not between 4” and 7” in height. 4.9.2 504.2 1009.3; 1133B.4 .5.3 -7 3/8" high.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 66 Top Stairs 08.03C - Tread Slope The treads have a slope steeper than 2%.-504.4 [Excepti on] 1009.5. 1 -2.2% to 3.7% slope.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 67 Top Stairs 08.07A - Continuous Handrails Continuous handrails are not provided along both sides. 4.9.4 504.6; 505.2 1133B.4 .1.1 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 68 Top Stairs 08.03D - Level Landing Landing is not level (slope is greater than 2% in some or all directions). --1009.5. 1 -Intermediate landings - 3.7% RS.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 69 Top Stairs 08.18 - Other - Stairs See Additional Comments ----Damaged stair surface.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 70 Top Stairs Page 119 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 08 - Stairs Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 08.09B - Handrail Extensions - Bottom Landing At ends of handrails, less than 12” plus the tread width extends beyond the bottom nosing. (Top and bottom handrail extensions are important safety features for persons with balance problems and must extend in the direction of the stair run to permit the intended use.) (Per ADA/CBC Standards, in existing buildings and facilities, full extension of handrails at stairs shall not be required in alterations where such extensions would be hazardous or impossible due to plan configuration.) 4.9.4(2) 505.10; 505.10. 3; Fig. 505.10. 3 1133B.4 .2.2 -None provided.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 71 Top Stairs 08.09A - Handrail Extensions - Top Landing At ends of handrails, less than 12” of handrail extends beyond the top nosing. (Top and bottom handrail extensions are important safety features for persons with balance problems and must extend in the direction of the stair run to permit the intended use.) (Per ADA/CBC Standards, in existing buildings and facilities, full extension of handrails at stairs shall not be required in alterations where such extensions would be hazardous or impossible due to plan configuration.) 4.9.4(2) 505.10; 505.10. 2; Fig. 505.10. 2 1133B.4 .2.2 -None provided.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 82 Middle Stairs 08.10A - Profile of Handrails The diameter of the handrail is not between 1- 1/4” and 1-1/2” in cross-sectional nomin.al dimension. OR The shape does not provide an equivalent gripping surface (equivalent gripping surfaces are 4” to 6-1/4” in perimeter, and 2- 1/4" max.. in any direction). (Note: Standard pipe sizes designated by the industry as 1-1/4” to 1-1/2” are acceptable). 4.9.4; 4.26.2 505.7.1; 505.7.2; Fig. 505.7.2 1133B.4 .2.6 -2".PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 83 Middle Stairs 08.07A - Continuous Handrails Continuous handrails are not provided along both sides. 4.9.4 504.6; 505.2 1133B.4 .1.1 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 84 Middle Stairs Page 120 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 08 - Stairs Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 08.05A - Exterior Stairs - Color Strip Contrasting color strips have not been provided. --1133B.4 .4 -PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 85 Middle Stairs 08.09E - Handrails - Height above Stair Nosings The tops of handrails are not between 34” and 38” above the stair nosings. 4.9.4(5) 505.4; Advisory 505.4; Fig. 505.4 1133B.4 .2.1 -29" high.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 86 Middle Stairs 08.03A - Tread Depth The treads are not uniform. OR The treads are less than 11” deep measured from riser to riser. 4.9.2 504.2 1009.3; 1133B.4 .5.3 -11" to 14".PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 87 Middle Stairs 08.02B - Riser Height The risers are not uniform. OR The risers are not between 4” and 7” in height. 4.9.2 504.2 1009.3; 1133B.4 .5.3 -6 1/2" to 7" high.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 88 Middle Stairs 08.03B - Tread Surface The tread surfaces are not stable, firm and slip- resistant. -504.4; Advisory 504.4 1133B.4 .5.1 -Uneven tread surface.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 89 Middle Stairs 08.03D - Level Landing Landing is not level (slope is greater than 2% in some or all directions). --1009.5. 1 -5.7% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 90 Middle Stairs Page 121 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 08 - Stairs Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 08.09B - Handrail Extensions - Bottom Landing At ends of handrails, less than 12” plus the tread width extends beyond the bottom nosing. (Top and bottom handrail extensions are important safety features for persons with balance problems and must extend in the direction of the stair run to permit the intended use.) (Per ADA/CBC Standards, in existing buildings and facilities, full extension of handrails at stairs shall not be required in alterations where such extensions would be hazardous or impossible due to plan configuration.) 4.9.4(2) 505.10; 505.10. 3; Fig. 505.10. 3 1133B.4 .2.2 -None provided.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 91 Middle Stairs 08.09A - Handrail Extensions - Top Landing At ends of handrails, less than 12” of handrail extends beyond the top nosing. (Top and bottom handrail extensions are important safety features for persons with balance problems and must extend in the direction of the stair run to permit the intended use.) (Per ADA/CBC Standards, in existing buildings and facilities, full extension of handrails at stairs shall not be required in alterations where such extensions would be hazardous or impossible due to plan configuration.) 4.9.4(2) 505.10; 505.10. 2; Fig. 505.10. 2 1133B.4 .2.2 -None provided.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 111 Bottom Stairs 08.09B - Handrail Extensions - Bottom Landing At ends of handrails, less than 12” plus the tread width extends beyond the bottom nosing. (Top and bottom handrail extensions are important safety features for persons with balance problems and must extend in the direction of the stair run to permit the intended use.) (Per ADA/CBC Standards, in existing buildings and facilities, full extension of handrails at stairs shall not be required in alterations where such extensions would be hazardous or impossible due to plan configuration.) 4.9.4(2) 505.10; 505.10. 3; Fig. 505.10. 3 1133B.4 .2.2 -None provided.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 112 Bottom Stairs Page 122 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 08 - Stairs Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 08.03D - Level Landing Landing is not level (slope is greater than 2% in some or all directions). --1009.5. 1 -3.3% RS, uneven landing.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 113 Bottom Stairs 08.05A - Exterior Stairs - Color Strip Contrasting color strips have not been provided. --1133B.4 .4 -None provided.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 114 Bottom Stairs 08.03C - Tread Slope The treads have a slope steeper than 2%.-504.4 [Excepti on] 1009.5. 1 -Uneven tread slope.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 115 Bottom Stairs 08.03A - Tread Depth The treads are not uniform. OR The treads are less than 11” deep measured from riser to riser. 4.9.2 504.2 1009.3; 1133B.4 .5.3 -10 1/2" to 11 1/2".PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 116 Bottom Stairs 08.02B - Riser Height The risers are not uniform. OR The risers are not between 4” and 7” in height. 4.9.2 504.2 1009.3; 1133B.4 .5.3 -6 1/2" to 7".PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 117 Bottom Stairs 08.10A - Profile of Handrails The diameter of the handrail is not between 1- 1/4” and 1-1/2” in cross-sectional nomin.al dimension. OR The shape does not provide an equivalent gripping surface (equivalent gripping surfaces are 4” to 6-1/4” in perimeter, and 2- 1/4" max.. in any direction). (Note: Standard pipe sizes designated by the industry as 1-1/4” to 1-1/2” are acceptable). 4.9.4; 4.26.2 505.7.1; 505.7.2; Fig. 505.7.2 1133B.4 .2.6 -2".PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 118 Bottom Stairs Page 123 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 08 - Stairs Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 08.02B - Riser Height The risers are not uniform. OR The risers are not between 4” and 7” in height. 4.9.2 504.2 1009.3; 1133B.4 .5.3 -5 1/2" to 6 1/4" high.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 135 Stairs 08.03E - Drainage Design of outside stairs and their approaches allows water to accumulate on walking surfaces. 4.9.6 504.7 1133B.4 .5.1 -Drain ditch runs along landings at 4 locations. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 136 Stairs 08.03D - Level Landing Landing is not level (slope is greater than 2% in some or all directions). --1009.5. 1 -2.7% to 12.9% RS at intermediate and bottom landings. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 137 Stairs 08.09B - Handrail Extensions - Bottom Landing At ends of handrails, less than 12” plus the tread width extends beyond the bottom nosing. (Top and bottom handrail extensions are important safety features for persons with balance problems and must extend in the direction of the stair run to permit the intended use.) (Per ADA/CBC Standards, in existing buildings and facilities, full extension of handrails at stairs shall not be required in alterations where such extensions would be hazardous or impossible due to plan configuration.) 4.9.4(2) 505.10; 505.10. 3; Fig. 505.10. 3 1133B.4 .2.2 -None provided.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 138 Stairs 08.05A - Exterior Stairs - Color Strip Contrasting color strips have not been provided. --1133B.4 .4 -PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 139 Stairs 08.07A - Continuous Handrails Continuous handrails are not provided along both sides. 4.9.4 504.6; 505.2 1133B.4 .1.1 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 140 Stairs Page 124 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 08 - Stairs Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 08.09A - Handrail Extensions - Top Landing At ends of handrails, less than 12” of handrail extends beyond the top nosing. (Top and bottom handrail extensions are important safety features for persons with balance problems and must extend in the direction of the stair run to permit the intended use.) (Per ADA/CBC Standards, in existing buildings and facilities, full extension of handrails at stairs shall not be required in alterations where such extensions would be hazardous or impossible due to plan configuration.) 4.9.4(2) 505.10; 505.10. 2; Fig. 505.10. 2 1133B.4 .2.2 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 141 Stairs 08.15 - Landing Size Landing depth in the direction of travel is not at least equal to the width of the stairway. --1009.4 -Intermediate landings 66" wide x 58" deep. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 142 Stairs 08.18 - Other - Stairs See Additional Comments ----Bad stair condition.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 143 Stairs 37Number of Key Notes for Group 08 - Stairs: Group 06 - Telephones Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 06.02B - ISA Sign The wheelchair accessible telephone is not identified by the ISA. 4.1.3(17 )(b); 4.30.7(1 ) 703.2.1; Fig. 703.2.1 1117B.5 .8.1 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 130 School Grounds Page 125 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 06 - Telephones Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 06.08 - Wall- Mounted Protruding Objects Wall-mounted telephone(s) with leading edges between 27" and 80” from the floor projects more than 4" into the circulation path. (Wall mounted telephones or their enclosures with leading edges at or below 27” may project any amount as long as the required clear width of an accessible route is not reduced.) 4.31.4; 4.4.1 204; 307.2; Advisory 307.2; Fig. 307.2 1133B.8 .6.1 -PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 131 School Grounds 2Number of Key Notes for Group 06 - Telephones: Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.84A - Paper Towel Dispenser - Operating Height Mounting height of paper towel dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one paper towel dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one paper towel dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -53" high.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 224 Classroom G 16.84A - Paper Towel Dispenser - Operating Height Mounting height of paper towel dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one paper towel dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one paper towel dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -53" high.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 303 Classroom K Page 126 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.84C - Soap Dispenser - Operating Height Mounting height of soap dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one soap dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one soap dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -41" high.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 304 Classroom K 16.84C - Soap Dispenser - Operating Height Mounting height of soap dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one soap dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one soap dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -42" high.GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 384 Classroom F 16.84A - Paper Towel Dispenser - Operating Height Mounting height of paper towel dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one paper towel dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one paper towel dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -42" high.GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 385 Classroom F 16.71 - Lavatory - Rim Height Height of lavatory rim or counter surface exceeds 34” AFF. 4.19.2; Fig. 31 606.3 1115B.4 .3(2); Fig 11B- 1D -25 1/2" high, 24" maximum allowed for kindergarten. GS - General Student Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 427 Classroom E - Restrooms Page 127 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.73 - Lavatory Knee Clearance Lavatory does not provide accessible knee clearance (i.e. at least 27” clearance from the floor to the underside of the lavatory, extending 8” min.. measured from the front edge underneath the lavatory back towards the wall). 4.19.2; Fig. 31 306.3; Fig. 306.3 1115B.4 .3(2); Fig 11B- 1D -No knee space.GS - General Student Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 428 Classroom E - Restrooms 16.47A - WC Location from Sidewall The centerline of the WC is not 18” absolute from a wall or partition. 4.22.4 -1115B.4 .1(1) -18 1/2" from sidewall, 12" allowed for kindergarten. GS - General Student Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 430 Classroom E - Restrooms 16.48 - WC Seat Height The top of the WC seat is not between 17” and 19” AFF. 4.16.3; Fig. 29(b) 604.4 1115B.4 .1(4); Fig. 11B-1A -GS - General Student Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 431 Classroom E - Restrooms 16.36A - Stall Width The stall is less than 60” wide.4.17.3; Fig. 30(a) 604.8.1. 1; Advisory 604.8.1. 1; Fig. 604.8.1. 1 1115B.3 .1(4.1) -51 1/4" wide.GS - General Student Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 432 Classroom E - Restrooms 16.56 - Grab Bar Wall Clearance The space between the grab bar and the wall is not 1-1/2” absolute. 4.17.6, 4.26.2; Fig. 39 609.3 1115B.7 .1; Fig. 11B-1C -1 3/8".GS - General Student Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 433 Classroom E - Restrooms 16.55A - Side Grab Bar Height Side grab bar is not centered at 33" AFF. (ADA Standards require side grab bars to be centered from 33" to 36" AFF; CBC Standards require side grab bars to be centered at 33" AFF.) 4.17.6; Figs. 29 & 30 604.5; Advisory 604.5; 604.5.2; Fig. 604.5.2; 609.4 1115B.4 .1(3.1); Fig. 11B-1A -31 1/2" high, 20" to 22" allowed for kindergarten. GS - General Student Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 434 Classroom E - Restrooms Page 128 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.55B - Back Grab Bar Height - Non- Tank-Type WC At non-tank-type WC, back grab bar is not centered at 33" AFF. (ADA Standards require back grab bars to be centered from 33" to 36" AFF; CBC Standards require back grab bars to be centered at 33" AFF.) 4.17.6; Figs. 29 & 30 604.5; Advisory 604.5; 609.4 1115B.4 .1(3.2); Fig. 11B-1A -31 1/2" high, 20" to 22" allowed for kindergarten. GS - General Student Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 435 Classroom E - Restrooms 16.13C - Unisex RR Geometric Symbol Signage - Circle/Triangle Doorway leading to a unisex toilet room is not identified by a 12” circle, 1/4" with a 1/4" thick triangle superimposed and within the circle. OR Circle and triangle are provided, however they are accompanied by words in raised characters and Braille. (ADA and CBC Standards require a separate sign with raised characters and Braille mounted on the wall adjacent to the latch side of the door.) --1115B.6 -GS - General Student Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 438 Classroom E - Restrooms 16.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand. OR They are not operable without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob.GS - General Student Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 448 Classroom E- Restrooms 16.13C - Unisex RR Geometric Symbol Signage - Circle/Triangle Doorway leading to a unisex toilet room is not identified by a 12” circle, 1/4" with a 1/4" thick triangle superimposed and within the circle. OR Circle and triangle are provided, however they are accompanied by words in raised characters and Braille. (ADA and CBC Standards require a separate sign with raised characters and Braille mounted on the wall adjacent to the latch side of the door.) --1115B.6 -GS - General Student Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 449 Classroom E- Restrooms Page 129 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.09A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6 404.2.4. 1; Table 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2; Fig. 11B-26 -6 1/2" on pull strike side due to furniture. GS - General Student Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 450 Classroom E- Restrooms 16.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -10 LBF., (fire rated door).PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 493 Men's Restroom 16.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand. OR They are not operable without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 494 Men's Restroom 16.13A - Men's RR Geometric Symbol Signage - Triangle Doorway leading to a men’s toilet room is not identified by an equilateral triangle 1/4" thick with edges 12” long. OR Equilateral triangle is provided, however it is accompanied by words in raised characters and Braille. (ADA and CBC Standards require a separate sign with raised characters and Braille mounted on the wall adjacent to the latch side of the door.) --1115B.6 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 495 Men's Restroom Page 130 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.15B - Room/Space Identification Signs (Visual/Tactile Signs) Sign designating the permanent room or space does not comply with ADAAG and CBC requirements for tactile signs. 4.30.1 216.2; Advisory 216.2; 703.1; 703.2; 703.5. 1117B.5 .1(1) -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 496 Men's Restroom 16.18A - ISA Accessible toilet room is not identified by an ISA. 4.1.3(16 )(b) 216.8 1117B.5 .1(3) -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 497 Men's Restroom 16.19B - Mounting Height (Visual/Tactile Signs) Sign is not mounted at 60” o.c. AFF to the centerline of the sign. (If the sign contains pictorial symbols (pictograms) or other non- tactile information, mounting height is measured to the centerline of the tactile characters / Braille portion of the sign.) 4.30.6 703.4.1 1117B.5 .7 -83" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 498 Men's Restroom 16.19A - Mounting Location (Visual/Tactile Signs) Sign is not mounted on the wall adjacent to the latch side of the door. OR At double leaf doors, the sign is not placed on the nearest adjacent wall. 4.30.6 703.4.2; Fig. 703.4.2 1117B.5 .7 -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 499 Men's Restroom Page 131 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.09A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6 404.2.4. 1; Table 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2; Fig. 11B-26 -38" deep door landing on push side. PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 500 Men's Restroom 16.12 - Other Door Requirements Door does not comply with all applicable ADAAG and CBC accessibility requirements. 4.13 404.1; Advisory 404.1 1133B.2 -Compound threshold.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 501 Men's Restroom 16.82B - Mirror Height - Max. 35" AFF Standard Mirror not above accessible lavatory or countertop is mounted so the bottom edge of the reflective surface is not 35” max.. AFF. (Effective August 1, 2009, where mirrors are provided at locations other than lavatories or countertops, amended CBC Standards require at least one to be accessible.) -213.3.5; 606.3; Advisory 603.3 1115B.8 .1 -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 504 Men's Restroom 16.84F - Diaper Changing Table - Operating Height Mounting height of diaper changing table's highest operable part exceeds 40" AFF. (Where provided, at least one shall be accessible.) 4.27.3 308; 309 --56" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 505 Men's Restroom 16.84G - Diaper Changing Table - Table Surface Height Height of diaper changing table surface is not between 28" to 34” AFF. (Where provided, at least one shall be accessible.) 4.1.3(18 ), 4.32.4 308; 309 1122B.1 , 1122B.4 -38" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 506 Men's Restroom Page 132 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.84A - Paper Towel Dispenser - Operating Height Mounting height of paper towel dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one paper towel dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one paper towel dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -54" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 507 Men's Restroom 16.84C - Soap Dispenser - Operating Height Mounting height of soap dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one soap dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one soap dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -41" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 508 Men's Restroom 16.72 - Lavatory Apron Clearance Lavatory does not provide accessible apron clearance (i.e. at least 29” clearance from the floor to the bottom of the apron). 4.19.2; Fig. 31 606.3 1115B.4 .3(2); Fig 11B- 1D -27 3/4" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 509 Men's Restroom 16.73 - Lavatory Knee Clearance Lavatory does not provide accessible knee clearance (i.e. at least 27” clearance from the floor to the underside of the lavatory, extending 8” min.. measured from the front edge underneath the lavatory back towards the wall). 4.19.2; Fig. 31 306.3; Fig. 306.3 1115B.4 .3(2); Fig 11B- 1D -25" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 510 Men's Restroom 16.78 - Pipe Insulation at Lavatory Drainpipes and hot water pipes are not insulated to protect against contact. 4.19.4 606.5 1115B.4 .3(4) -PV - Public/Visitor Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 511 Men's Restroom Page 133 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.79 - Smooth Surfaces at Lavatory The area below the lavatory is not free of sharp or abrasive surfaces. 4.19.4 606.5 1115B.4 .3(4) -PV - Public/Visitor Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 512 Men's Restroom 16.80 - Faucet Operation at Lavatory The faucet is not compliant. (Accessible faucets shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.19.5; 4.27.4 309.4; 606.4 1115B.4 .3(1) -Knob.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 513 Men's Restroom 16.62A_04AG - Semi-Ambulant Stall A semi-ambulant stall is not provided, in addition to the 60” wide standard stall, where 6 or more toilet stalls are provided, or where a combination of 6 or more urinals and water closets are provided. 4.22.4 213.3.1; Advisory 213.3.1; 604.8.2; Fig. 604.8.2 1115B.3 .1(5) -5 urinals and 3 stalls, 0 semi- ambulant stalls. PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 514 Men's Restroom 16.64A - Urinals An accessible urinal has not been provided where urinals are provided. (If urinals are provided, ADA Standards require at least one accessible urinal.) 4.22.5 213.3.3; 605.1; Advisory 605.1 1115B.4 .2 -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 515 Men's Restroom 16.88 - Other - Toilet Facilities See Additional Comments ----4" step to urinals.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 516 Men's Restroom 16.32A - U- Pulls at Stall Door The stall door does not have U-pulls on both sides. 4.13.9; 4.17.5 309.4; 404.27; 604.8.1. 2 1115B.3 .1(4.4) -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 517 Men's Restroom Page 134 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.32B - Single- Action Stall Door Hardware The stall door's locking mechanism is not operable with one hand. OR It is not operable without tight grasping, pinching, or twisting of the wrist. 4.13.9; 4.17.5 309.4; 404.2.7; Advisory 404.2.7 1117B.6 (4) -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 518 Men's Restroom 16.34 - Strike Side Clearance at Stall Door Where the stall door opens out at the end of an aisle, there is less than 18” of maneuvering space at the latch side of the stall door. 4.17.5; 4.13.6; Fig. 25 404.2.4. 1; Tab.404 .2.4.1; Fig.404. 2.4.1 1133B.2 .4.3; Figs. 11B-26B -3" strike clearance.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 519 Men's Restroom 16.36A - Stall Width The stall is less than 60” wide.4.17.3; Fig. 30(a) 604.8.1. 1; Advisory 604.8.1. 1; Fig. 604.8.1. 1 1115B.3 .1(4.1) -44" wide.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 520 Men's Restroom 16.39B - Maneuvering Space - In- Swinging End- Opening Door Where the stall has an in-swinging end-opening stall door, the clear space in front of the WC is less than 60" wide by 60" deep. 4.17.3; Fig. 30(b) 404.2.4. 1; Table 404.2.4. 1; Fig. 404.2.4. 1 1115B.3 .1(4.2) -44" x 30".PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 521 Men's Restroom 16.47A - WC Location from Sidewall The centerline of the WC is not 18” absolute from a wall or partition. 4.22.4 -1115B.4 .1(1) -15".PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 522 Men's Restroom Page 135 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.50_07CBC - TP Dispenser - Location Location of the toilet paper dispenser is not compliant. (Effective January 1, 2008, CBC Standards require toilet tissue dispensers located on the wall within 12" of the front edge of the toilet seat, mounted below the grab bar, centered at a min. height of 19" AFF, and 36" maximum to the dispenser's far edge from the rear wall; there is no requirement to retroactively alter existing toilet paper dispensers when installed in compliance with CBC Standards in effect at the time of original construction.) 4.16.6; Fig. 29(b) 604.7; Advisory 604.7; Fig. 604.7 1115B.8 .4; Fig. 11B-1A -4" from WC and 33" from finish floor. PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 523 Men's Restroom 16.54B - Side Grab Bar Length Side grab bar is less than 42” long. (ADA Standards require the side grab bar for WC's not located in stalls to be 42" long min..; ADA Standards require the side grab bar for WC's located in stalls to be 40" to 42" long min..; CBC Standards require the side grab bar to be 42" long min..) 4.17.6; Figs. 29 & 30 604.5; Advisory 604.5; 604.5.1; Fig. 604.5.1; 609.4 1115B.4 .1(3.1); Fig. 11B-1A -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 524 Men's Restroom 16.54A - Grab Bar Grab bar is not provided.4.17.6; Figs. 29 & 30 604.5; Advisory 604.5; 609.4 1115B.4 .1(3.1) & (3.2); Fig. 11B-1A -None provided.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 525 Men's Restroom 16.55A - Side Grab Bar Height Side grab bar is not centered at 33" AFF. (ADA Standards require side grab bars to be centered from 33" to 36" AFF; CBC Standards require side grab bars to be centered at 33" AFF.) 4.17.6; Figs. 29 & 30 604.5; Advisory 604.5; 604.5.2; Fig. 604.5.2; 609.4 1115B.4 .1(3.1); Fig. 11B-1A -27" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 526 Men's Restroom Page 136 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.09A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6 404.2.4. 1; Table 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2; Fig. 11B-26 -2" on push side, 37" deep landing on push side. PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 530 Women's Restroom 16.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand. OR They are not operable without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 531 Women's Restroom 16.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -11 LBF., (fire rated door).PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 532 Women's Restroom 16.13B - Women's RR Geometric Symbol Signage - Circle Doorway leading to a women’s toilet room is not identified by a circle, 1/4" thick and 12” in diameter. OR Circle is provided, however it is accompanied by words in raised characters and Braille. (ADA and CBC Standards require a separate sign with raised characters and Braille mounted on the wall adjacent to the latch side of the door.) --1115B.6 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 533 Women's Restroom Page 137 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.15B - Room/Space Identification Signs (Visual/Tactile Signs) Sign designating the permanent room or space does not comply with ADAAG and CBC requirements for tactile signs. 4.30.1 216.2; Advisory 216.2; 703.1; 703.2; 703.5. 1117B.5 .1(1) -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 534 Women's Restroom 16.18A - ISA Accessible toilet room is not identified by an ISA. 4.1.3(16 )(b) 216.8 1117B.5 .1(3) -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 535 Women's Restroom 16.19B - Mounting Height (Visual/Tactile Signs) Sign is not mounted at 60” o.c. AFF to the centerline of the sign. (If the sign contains pictorial symbols (pictograms) or other non- tactile information, mounting height is measured to the centerline of the tactile characters / Braille portion of the sign.) 4.30.6 703.4.1 1117B.5 .7 -83" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 536 Women's Restroom 16.12 - Other Door Requirements Door does not comply with all applicable ADAAG and CBC accessibility requirements. 4.13 404.1; Advisory 404.1 1133B.2 -Compound threshold.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 537 Women's Restroom 16.82B - Mirror Height - Max. 35" AFF Standard Mirror not above accessible lavatory or countertop is mounted so the bottom edge of the reflective surface is not 35” max.. AFF. (Effective August 1, 2009, where mirrors are provided at locations other than lavatories or countertops, amended CBC Standards require at least one to be accessible.) -213.3.5; 606.3; Advisory 603.3 1115B.8 .1 -41 3/4" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 539 Women's Restroom Page 138 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.84D - Sanitary Napkin/Feminine Hygiene Dispenser - Operating Height Mounting height of sanitary napkin/femin.ine hygiene dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one sanitary napkin/femin.ine hygiene dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one sanitary napkin/femin.ine hygiene dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -44" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 540 Women's Restroom 16.84A - Paper Towel Dispenser - Operating Height Mounting height of paper towel dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one paper towel dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one paper towel dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -55" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 541 Women's Restroom 16.84C - Soap Dispenser - Operating Height Mounting height of soap dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one soap dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one soap dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -41" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 542 Women's Restroom Page 139 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.84G - Diaper Changing Table - Table Surface Height Height of diaper changing table surface is not between 28" to 34” AFF. (Where provided, at least one shall be accessible.) 4.1.3(18 ), 4.32.4 308; 309 1122B.1 , 1122B.4 -39 1/2" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 543 Women's Restroom 16.84F - Diaper Changing Table - Operating Height Mounting height of diaper changing table's highest operable part exceeds 40" AFF. (Where provided, at least one shall be accessible.) 4.27.3 308; 309 --56" to linens.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 544 Women's Restroom 16.72 - Lavatory Apron Clearance Lavatory does not provide accessible apron clearance (i.e. at least 29” clearance from the floor to the bottom of the apron). 4.19.2; Fig. 31 606.3 1115B.4 .3(2); Fig 11B- 1D -28 3/8" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 546 Women's Restroom 16.73 - Lavatory Knee Clearance Lavatory does not provide accessible knee clearance (i.e. at least 27” clearance from the floor to the underside of the lavatory, extending 8” min.. measured from the front edge underneath the lavatory back towards the wall). 4.19.2; Fig. 31 306.3; Fig. 306.3 1115B.4 .3(2); Fig 11B- 1D -25" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 547 Women's Restroom 16.78 - Pipe Insulation at Lavatory Drainpipes and hot water pipes are not insulated to protect against contact. 4.19.4 606.5 1115B.4 .3(4) -PV - Public/Visitor Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 548 Women's Restroom 16.79 - Smooth Surfaces at Lavatory The area below the lavatory is not free of sharp or abrasive surfaces. 4.19.4 606.5 1115B.4 .3(4) -PV - Public/Visitor Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 549 Women's Restroom 16.80 - Faucet Operation at Lavatory The faucet is not compliant. (Accessible faucets shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.19.5; 4.27.4 309.4; 606.4 1115B.4 .3(1) -Knob.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 550 Women's Restroom Page 140 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.32A - U- Pulls at Stall Door The stall door does not have U-pulls on both sides. 4.13.9; 4.17.5 309.4; 404.27; 604.8.1. 2 1115B.3 .1(4.4) -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 551 Women's Restroom 16.33 - Self- Closing Stall Door The stall door is not self-closing.4.13.10 604.8.1. 2 1115B.3 .1(4.4) -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 552 Women's Restroom 16.34 - Strike Side Clearance at Stall Door Where the stall door opens out at the end of an aisle, there is less than 18” of maneuvering space at the latch side of the stall door. 4.17.5; 4.13.6; Fig. 25 404.2.4. 1; Tab.404 .2.4.1; Fig.404. 2.4.1 1133B.2 .4.3; Figs. 11B-26B -10 1/4".PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 553 Women's Restroom 16.47A - WC Location from Sidewall The centerline of the WC is not 18” absolute from a wall or partition. 4.22.4 -1115B.4 .1(1) -17 3/8".PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 554 Women's Restroom 16.48 - WC Seat Height The top of the WC seat is not between 17” and 19” AFF. 4.16.3; Fig. 29(b) 604.4 1115B.4 .1(4); Fig. 11B-1A -16 1/2".PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 555 Women's Restroom 16.49B - WC Flush Controls - Location Flush controls are not located on the wide side of the WC where the clear floor space is provided. 4.16.5 604.6; Advisory 604.6 1115B.4 .1(5); Fig. 11B-1A -Not located on transfer side.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 556 Women's Restroom Page 141 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.50_07CBC - TP Dispenser - Location Location of the toilet paper dispenser is not compliant. (Effective January 1, 2008, CBC Standards require toilet tissue dispensers located on the wall within 12" of the front edge of the toilet seat, mounted below the grab bar, centered at a min. height of 19" AFF, and 36" maximum to the dispenser's far edge from the rear wall; there is no requirement to retroactively alter existing toilet paper dispensers when installed in compliance with CBC Standards in effect at the time of original construction.) 4.16.6; Fig. 29(b) 604.7; Advisory 604.7; Fig. 604.7 1115B.8 .4; Fig. 11B-1A -5" from WC and 36" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 557 Women's Restroom 16.54B - Side Grab Bar Length Side grab bar is less than 42” long. (ADA Standards require the side grab bar for WC's not located in stalls to be 42" long min..; ADA Standards require the side grab bar for WC's located in stalls to be 40" to 42" long min..; CBC Standards require the side grab bar to be 42" long min..) 4.17.6; Figs. 29 & 30 604.5; Advisory 604.5; 604.5.1; Fig. 604.5.1; 609.4 1115B.4 .1(3.1); Fig. 11B-1A -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 558 Women's Restroom 16.54A - Grab Bar Grab bar is not provided.4.17.6; Figs. 29 & 30 604.5; Advisory 604.5; 609.4 1115B.4 .1(3.1) & (3.2); Fig. 11B-1A -No back grab bar provided.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 559 Women's Restroom 16.55A - Side Grab Bar Height Side grab bar is not centered at 33" AFF. (ADA Standards require side grab bars to be centered from 33" to 36" AFF; CBC Standards require side grab bars to be centered at 33" AFF.) 4.17.6; Figs. 29 & 30 604.5; Advisory 604.5; 604.5.2; Fig. 604.5.2; 609.4 1115B.4 .1(3.1); Fig. 11B-1A -27" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 560 Women's Restroom Page 142 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.39A - Maneuvering Space in Front of WC - End- Opening Door Where the stall has an end-opening stall door, the clear space in front of the WC is less than 60" wide by 48" deep. 4.17.3; Fig. 30(b) 404.2.4. 1; Table 404.2.4. 1; Fig. 404.2.4. 1 1115B.4 .1(2); Fig. 11B-1A -27" from WC.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 561 Women's Restroom 16.83 - Coat Hook - Height Where a coat hook is provided In an accessible stall, height of coat hook exceeds 48” AFF. 4.2.5 213.3.7; 308; 603.4 1117B.8 -64" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 562 Women's Restroom 16.19A - Mounting Location (Visual/Tactile Signs) Sign is not mounted on the wall adjacent to the latch side of the door. OR At double leaf doors, the sign is not placed on the nearest adjacent wall. 4.30.6 703.4.2; Fig. 703.4.2 1117B.5 .7 -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 563 Women's Restroom 16.88 - Other - Toilet Facilities See Additional Comments ----24 3/8" high to sink, 24" maximum allowed for kindergarten. GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 596 Classroom A 16.82A - Mirror Height - Max. 40" AFF Standard Mirror above accessible lavatory or countertop is mounted so the bottom edge of the reflective surface is not 40” max.. AFF. (ADA Standards require at least one mirror to be accessible; CBC Standards prior to August 1, 2009 required all mirrors to be accessible. Effective August 1, 2009, amended CBC Standards require all mirrors above accessible lavatories or countertops to be accessible.) 4.19.6; Fig. 31 213.3.5; 603.3; Advisory 603.3 1115B.8 .1 -32 3/8" high mirror, 32" maximum allowed for kindergarten. GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 597 Classroom A 16.88 - Other - Toilet Facilities See Additional Comments ----Lavatory 26 1/2" high, 24" maximum allowed for kindergarten. GS - General Student Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 607 Classroom A - Restroom Page 143 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.84G - Diaper Changing Table - Table Surface Height Height of diaper changing table surface is not between 28" to 34” AFF. (Where provided, at least one shall be accessible.) 4.1.3(18 ), 4.32.4 308; 309 1122B.1 , 1122B.4 -36" high.GS - General Student Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 608 Classroom A - Restroom 16.01 - Toilet Rooms Toilet room does not comply with all applicable ADAAG and CBC accessibility requirements. 4.1.2(6) ; 4.1.3(11 ); 4.22.1 213.2; Advisory 213.2 1115B.1 -No accessible restroom.GS - General Student Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 609 Classroom A - Restroom 16.13C - Unisex RR Geometric Symbol Signage - Circle/Triangle Doorway leading to a unisex toilet room is not identified by a 12” circle, 1/4" with a 1/4" thick triangle superimposed and within the circle. OR Circle and triangle are provided, however they are accompanied by words in raised characters and Braille. (ADA and CBC Standards require a separate sign with raised characters and Braille mounted on the wall adjacent to the latch side of the door.) --1115B.6 -GS - General Student Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 611 Classroom A - Restroom 16.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -6 LBF.GS - General Student Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 613 Children's Restroom 16.01 - Toilet Rooms Toilet room does not comply with all applicable ADAAG and CBC accessibility requirements. 4.1.2(6) ; 4.1.3(11 ); 4.22.1 213.2; Advisory 213.2 1115B.1 -GS - General Student Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 614 Children's Restroom 16.07 - Clear Door Opening When the door is open 90 degrees, clear opening width is less than 32” measured between the face of the door and the doorstop on the latch side. 4.13.5 404.2.3 1133B.1 .1.1.1; 1133B.2 .2 -23" wide.GS - General Student Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 615 Children's Restroom Page 144 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.09A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6 404.2.4. 1; Table 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2; Fig. 11B-26 -34" deep door landing on pull side. GS - General Student Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 616 Children's Restroom 16.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand. OR They are not operable without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob.GS - General Student Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 617 Children's Restroom 16.12 - Other Door Requirements Door does not comply with all applicable ADAAG and CBC accessibility requirements. 4.13 404.1; Advisory 404.1 1133B.2 -Compound threshold.GS - General Student Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 618 Children's Restroom 16.12 - Other Door Requirements Door does not comply with all applicable ADAAG and CBC accessibility requirements. 4.13 404.1; Advisory 404.1 1133B.2 -2.3 seconds door sweep.GS - General Student Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 619 Children's Restroom Page 145 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.13C - Unisex RR Geometric Symbol Signage - Circle/Triangle Doorway leading to a unisex toilet room is not identified by a 12” circle, 1/4" with a 1/4" thick triangle superimposed and within the circle. OR Circle and triangle are provided, however they are accompanied by words in raised characters and Braille. (ADA and CBC Standards require a separate sign with raised characters and Braille mounted on the wall adjacent to the latch side of the door.) --1115B.6 -GS - General Student Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 620 Children's Restroom 16.15B - Room/Space Identification Signs (Visual/Tactile Signs) Sign designating the permanent room or space does not comply with ADAAG and CBC requirements for tactile signs. 4.30.1 216.2; Advisory 216.2; 703.1; 703.2; 703.5. 1117B.5 .1(1) -GS - General Student Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 621 Children's Restroom 16.18A - ISA Accessible toilet room is not identified by an ISA. 4.1.3(16 )(b) 216.8 1117B.5 .1(3) -GS - General Student Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 622 Children's Restroom 16.12 - Other Door Requirements Door does not comply with all applicable ADAAG and CBC accessibility requirements. 4.13 404.1; Advisory 404.1 1133B.2 -2.3% RS at door landing.GS - General Student Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 624 Children's Restroom Page 146 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.50_07CBC - TP Dispenser - Location Location of the toilet paper dispenser is not compliant. (Effective January 1, 2008, CBC Standards require toilet tissue dispensers located on the wall within 12" of the front edge of the toilet seat, mounted below the grab bar, centered at a min. height of 19" AFF, and 36" maximum to the dispenser's far edge from the rear wall; there is no requirement to retroactively alter existing toilet paper dispensers when installed in compliance with CBC Standards in effect at the time of original construction.) 4.16.6; Fig. 29(b) 604.7; Advisory 604.7; Fig. 604.7 1115B.8 .4; Fig. 11B-1A -38" high.GS - General Student Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 625 Children's Restroom 16.88 - Other - Toilet Facilities See Additional Comments ----45" high PTD, 44" maximum allowed for kindergarten. GS - General Student Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 626 Children's Restroom 16.88 - Other - Toilet Facilities See Additional Comments ----17" high seat, 11" to 12" allowed for kindergarten. GS - General Student Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 627 Children's Restroom 16.88 - Other - Toilet Facilities See Additional Comments ----15 1/2" to WC, 12" allowed for kindergarten. GS - General Student Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 628 Children's Restroom 16.88 - Other - Toilet Facilities See Additional Comments ----46" high mirror, 32" maximum allowed for kindergarten. GS - General Student Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 629 Children's Restroom 16.88 - Other - Toilet Facilities See Additional Comments ----Lavatory height 31 1/2", 24" maximum allowed for kindergarten. GS - General Student Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 630 Children's Restroom Page 147 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.78 - Pipe Insulation at Lavatory Drainpipes and hot water pipes are not insulated to protect against contact. 4.19.4 606.5 1115B.4 .3(4) -GS - General Student Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 631 Children's Restroom 16.01 - Toilet Rooms Toilet room does not comply with all applicable ADAAG and CBC accessibility requirements. 4.1.2(6) ; 4.1.3(11 ); 4.22.1 213.2; Advisory 213.2 1115B.1 -EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 633 Faculty Restroom 16.07 - Clear Door Opening When the door is open 90 degrees, clear opening width is less than 32” measured between the face of the door and the doorstop on the latch side. 4.13.5 404.2.3 1133B.1 .1.1.1; 1133B.2 .2 -23" wide.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 634 Faculty Restroom 16.09A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6 404.2.4. 1; Table 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2; Fig. 11B-26 -35" deep door landing on pull side. EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 635 Faculty Restroom 16.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand. OR They are not operable without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 636 Faculty Restroom Page 148 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.12 - Other Door Requirements Door does not comply with all applicable ADAAG and CBC accessibility requirements. 4.13 404.1; Advisory 404.1 1133B.2 -6.2% RS at door landing.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 637 Faculty Restroom 16.12 - Other Door Requirements Door does not comply with all applicable ADAAG and CBC accessibility requirements. 4.13 404.1; Advisory 404.1 1133B.2 -Door stop.EC - Employee Common Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 638 Faculty Restroom 16.13C - Unisex RR Geometric Symbol Signage - Circle/Triangle Doorway leading to a unisex toilet room is not identified by a 12” circle, 1/4" with a 1/4" thick triangle superimposed and within the circle. OR Circle and triangle are provided, however they are accompanied by words in raised characters and Braille. (ADA and CBC Standards require a separate sign with raised characters and Braille mounted on the wall adjacent to the latch side of the door.) --1115B.6 -EC - Employee Common Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 639 Faculty Restroom 16.15A - Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.30.1 216.2; 703.1; 703.2; 703.5 1117B.5 .1(1) -EC - Employee Common Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 640 Faculty Restroom 16.18A - ISA Accessible toilet room is not identified by an ISA. 4.1.3(16 )(b) 216.8 1117B.5 .1(3) -EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 641 Faculty Restroom 16.27A - 60” Wide Circle or T- Shaped Maneuvering Space The toilet room does not include an unobstructed turning space (a 60” diameter, 27" high circle or T-shaped space). (Note: The clear floor space of fixtures and controls, the accessible path of travel, and the turning space may overlap.) 4.22.3; Fig 3 304.3.2; Fig.304. 3.2; 603.2.1 1115B.3 .1(1); 1115B.3 .2(1) -EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 642 Faculty Restroom Page 149 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.47A - WC Location from Sidewall The centerline of the WC is not 18” absolute from a wall or partition. 4.22.4 -1115B.4 .1(1) -13 1/2".EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 643 Faculty Restroom 16.48 - WC Seat Height The top of the WC seat is not between 17” and 19” AFF. 4.16.3; Fig. 29(b) 604.4 1115B.4 .1(4); Fig. 11B-1A -15 1/2" high.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 644 Faculty Restroom 16.49B - WC Flush Controls - Location Flush controls are not located on the wide side of the WC where the clear floor space is provided. 4.16.5 604.6; Advisory 604.6 1115B.4 .1(5); Fig. 11B-1A -EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 645 Faculty Restroom 16.82A - Mirror Height - Max. 40" AFF Standard Mirror above accessible lavatory or countertop is mounted so the bottom edge of the reflective surface is not 40” max.. AFF. (ADA Standards require at least one mirror to be accessible; CBC Standards prior to August 1, 2009 required all mirrors to be accessible. Effective August 1, 2009, amended CBC Standards require all mirrors above accessible lavatories or countertops to be accessible.) 4.19.6; Fig. 31 213.3.5; 603.3; Advisory 603.3 1115B.8 .1 -45".EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 646 Faculty Restroom 16.72 - Lavatory Apron Clearance Lavatory does not provide accessible apron clearance (i.e. at least 29” clearance from the floor to the bottom of the apron). 4.19.2; Fig. 31 606.3 1115B.4 .3(2); Fig 11B- 1D -27 1/2".EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 647 Faculty Restroom 16.73 - Lavatory Knee Clearance Lavatory does not provide accessible knee clearance (i.e. at least 27” clearance from the floor to the underside of the lavatory, extending 8” min.. measured from the front edge underneath the lavatory back towards the wall). 4.19.2; Fig. 31 306.3; Fig. 306.3 1115B.4 .3(2); Fig 11B- 1D -26".EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 648 Faculty Restroom Page 150 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.78 - Pipe Insulation at Lavatory Drainpipes and hot water pipes are not insulated to protect against contact. 4.19.4 606.5 1115B.4 .3(4) -EC - Employee Common Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 649 Faculty Restroom 16.12 - Other Door Requirements Door does not comply with all applicable ADAAG and CBC accessibility requirements. 4.13 404.1; Advisory 404.1 1133B.2 -Compound threshold.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 651 Faculty Restroom 16.88 - Other - Toilet Facilities See Additional Comments ----Loose floor mat.EC - Employee Common Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 653 Faculty Restroom 16.84A - Paper Towel Dispenser - Operating Height Mounting height of paper towel dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one paper towel dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one paper towel dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -51" high.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 664 Multi- purpose Room 16.84A - Paper Towel Dispenser - Operating Height Mounting height of paper towel dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one paper towel dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one paper towel dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -50" high.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 685 Kitchen Page 151 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.01 - Toilet Rooms Toilet room does not comply with all applicable ADAAG and CBC accessibility requirements. 4.1.2(6) ; 4.1.3(11 ); 4.22.1 213.2; Advisory 213.2 1115B.1 -EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 690 Staff Restroom 16.07 - Clear Door Opening When the door is open 90 degrees, clear opening width is less than 32” measured between the face of the door and the doorstop on the latch side. 4.13.5 404.2.3 1133B.1 .1.1.1; 1133B.2 .2 -24" wide.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 691 Staff Restroom 16.08A - Door Swing The door swing intrudes into the clear floor space of one or more fixtures. 4.22.2 603.2.3; Advisory 603.2.3 1115B.3 .1 item 2; 1115B.3 .2 item 2; 1115B.5 -EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 692 Staff Restroom 16.09A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6 404.2.4. 1; Table 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2; Fig. 11B-26 -47" deep landing on pull side, 6" strike side. EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 693 Staff Restroom Page 152 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.13C - Unisex RR Geometric Symbol Signage - Circle/Triangle Doorway leading to a unisex toilet room is not identified by a 12” circle, 1/4" with a 1/4" thick triangle superimposed and within the circle. OR Circle and triangle are provided, however they are accompanied by words in raised characters and Braille. (ADA and CBC Standards require a separate sign with raised characters and Braille mounted on the wall adjacent to the latch side of the door.) --1115B.6 -EC - Employee Common Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 694 Staff Restroom 16.15A - Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.30.1 216.2; 703.1; 703.2; 703.5 1117B.5 .1(1) -EC - Employee Common Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 695 Staff Restroom 16.18A - ISA Accessible toilet room is not identified by an ISA. 4.1.3(16 )(b) 216.8 1117B.5 .1(3) -EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 696 Staff Restroom 16.84A - Paper Towel Dispenser - Operating Height Mounting height of paper towel dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one paper towel dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one paper towel dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -51" high.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 697 Staff Restroom Page 153 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.84C - Soap Dispenser - Operating Height Mounting height of soap dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one soap dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one soap dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -52" high.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 698 Staff Restroom 16.82A - Mirror Height - Max. 40" AFF Standard Mirror above accessible lavatory or countertop is mounted so the bottom edge of the reflective surface is not 40” max.. AFF. (ADA Standards require at least one mirror to be accessible; CBC Standards prior to August 1, 2009 required all mirrors to be accessible. Effective August 1, 2009, amended CBC Standards require all mirrors above accessible lavatories or countertops to be accessible.) 4.19.6; Fig. 31 213.3.5; 603.3; Advisory 603.3 1115B.8 .1 -49 1/2" high.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 699 Staff Restroom 16.72 - Lavatory Apron Clearance Lavatory does not provide accessible apron clearance (i.e. at least 29” clearance from the floor to the bottom of the apron). 4.19.2; Fig. 31 606.3 1115B.4 .3(2); Fig 11B- 1D -28".EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 700 Staff Restroom 16.73 - Lavatory Knee Clearance Lavatory does not provide accessible knee clearance (i.e. at least 27” clearance from the floor to the underside of the lavatory, extending 8” min.. measured from the front edge underneath the lavatory back towards the wall). 4.19.2; Fig. 31 306.3; Fig. 306.3 1115B.4 .3(2); Fig 11B- 1D -25".EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 701 Staff Restroom 16.78 - Pipe Insulation at Lavatory Drainpipes and hot water pipes are not insulated to protect against contact. 4.19.4 606.5 1115B.4 .3(4) -EC - Employee Common Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 702 Staff Restroom Page 154 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.79 - Smooth Surfaces at Lavatory The area below the lavatory is not free of sharp or abrasive surfaces. 4.19.4 606.5 1115B.4 .3(4) -EC - Employee Common Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 703 Staff Restroom 16.47A - WC Location from Sidewall The centerline of the WC is not 18” absolute from a wall or partition. 4.22.4 -1115B.4 .1(1) -26".EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 704 Staff Restroom 16.48 - WC Seat Height The top of the WC seat is not between 17” and 19” AFF. 4.16.3; Fig. 29(b) 604.4 1115B.4 .1(4); Fig. 11B-1A -15 1/2" high.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 705 Staff Restroom 16.54A - Grab Bar Grab bar is not provided.4.17.6; Figs. 29 & 30 604.5; Advisory 604.5; 609.4 1115B.4 .1(3.1) & (3.2); Fig. 11B-1A -None provided.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 706 Staff Restroom 16.53 - SC Dispenser Height Mounting height of seat cover dispenser's highest operable part exceeds 40" AFF. 4.22.7; 4.27.3; 4.2.5; 4.2.6 -1115B.8 .3 -55".EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 707 Staff Restroom 16.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand. OR They are not operable without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Knob.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 709 Staff Restroom 145Number of Key Notes for Group 16 - Toilet Facilities: 797Number of Key Notes for Facility 08 - Ladera Linda Park & Community Center: Page 155 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 08 - Ladera Linda Park & Community CenterReporting: 797 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment 797Total Number of Key Notes for All Groups: Page 156 of 156 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA