Loading...
Eastview Park_ComplianceReport_20130509-113603Facility ID # 05 - Eastview ParkReporting: 120 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 04 - Curb Ramps Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 04.03 - Transition The transition from the curb ramp to the road or gutter is not flush or free of abrupt changes. 4.7.2 406.2; Fig. 406.2 1127B.5 item 3 2005 PROWA G- R301.5. 1 1" lip.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 10 Parking 04.09B - Grooved Border - Location A 12” wide grooved border has not been provided on the level surface of the walkway. --1127B.5 item 6 -On sloped surface.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 11 Parking 04.10 - Detectable Warning Requirement Regardless of slope, the curb ramp does not have a detectable warning. 4.7.7; 4.29.2 705.1; Fig. 705.1 1127B.5 item 7 2005 PROWA G- R303.3. 2 None provided.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 12 Parking 3Number of Key Notes for Group 04 - Curb Ramps: Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -MS - Maintenance and Storage Only E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 81 Maintenance Room 1Number of Key Notes for Group 11 - Doors and Gates: Group 05 - Drinking Fountains Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation Page 1 of 23 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 05 - Eastview ParkReporting: 120 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 05 - Drinking Fountains Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 05.01A - "Hi" Drinking Fountain Requirement Where there is only one drinking fountain area on a floor (e.g.., an area with a drinking fountain or separate drinking fountains), it is accessible to wheelchair users and not to persons who have difficulty bending or stooping (i.e., the required accessibility for persons who have difficulty bending or stooping on each floor has not been provided). 4.1.3(10 )(a); 4.15.1 211.1; 211.2 1115B.4 .6 item 1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 82 Drinking Fountain 05.08A - Wall- Mounted Protruding Objects Wall mounted drinking fountain with leading edges between 27" and 80” from the floor projects more than 4" into the circulation path. 4.4.1 204; 307.2; Advisory 307.2; Fig. 1133B.8 .6.1 -PV - Public/Visitor Use A - Safety Hazard 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 83 Drinking Fountain 2Number of Key Notes for Group 05 - Drinking Fountains: Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Door knob.MS - Maintenance and Storage Only B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 80 Maintenance Room 1Number of Key Notes for Group 10 - Entrances and Exits: Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation Page 2 of 23 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 05 - Eastview ParkReporting: 120 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.22 - Other - On-Site Accessible Path of Travel See Additional Comments ----1" gap.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 9 Parking 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.1% to 4.0% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 13 Concrete Path 03B.10 - Running Slope Slope of the accessible route of travel exceeds 1:20. 4.3.7 403.3 1133B.7 .3 -5.2% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 14 Concrete Path 03B.10 - Running Slope Slope of the accessible route of travel exceeds 1:20. 4.3.7 403.3 1133B.7 .3 -5.7% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 15 Concrete Path 03B.10 - Running Slope Slope of the accessible route of travel exceeds 1:20. 4.3.7 403.3 1133B.7 .3 -5.4% to 5.8% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 16 Concrete Path 03B.10 - Running Slope Slope of the accessible route of travel exceeds 1:20. 4.3.7 403.3 1133B.7 .3 -5.1% to 5.6% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 17 Concrete Path 03B.10 - Running Slope Slope of the accessible route of travel exceeds 1:20. 4.3.7 403.3 1133B.7 .3 -5.6% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 18 Concrete Path Page 3 of 23 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 05 - Eastview ParkReporting: 120 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -3.7% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 19 Concrete Path 03B.10 - Running Slope Slope of the accessible route of travel exceeds 1:20. 4.3.7 403.3 1133B.7 .3 -5.5% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 20 Concrete Path 03B.22 - Other - On-Site Accessible Path of Travel See Additional Comments ----21 1" gaps throughout concrete path. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 21 Concrete Path 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.3% to 9.6% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 22 Sidewalk 03B.10 - Running Slope Slope of the accessible route of travel exceeds 1:20. 4.3.7 403.3 1133B.7 .3 -5.2% to 7.8% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 23 Sidewalk 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.7% to 5.9% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 24 Concrete Path 03B.10 - Running Slope Slope of the accessible route of travel exceeds 1:20. 4.3.7 403.3 1133B.7 .3 -6.3% to 19.6% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 25 Concrete Path Page 4 of 23 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 05 - Eastview ParkReporting: 120 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.5% to 2.8% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 49 Concrete Path 03B.22 - Other - On-Site Accessible Path of Travel See Additional Comments ----1" gap.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 50 Concrete Path 03B.17 - > 4” Abrupt Change in Level Site includes abrupt changes in level adjacent to pedestrian areas exceeding 4” vertical (exceptions: (1) between a walk or sidewalk and an adjacent street or driveway, or (2) where a 6” high warning curb or guardrail is provided to warn of a potential drop off). --1133B.8 .1 -4" - 12" drop from grass area to playground area. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 56 Playground Area 03B.22 - Other - On-Site Accessible Path of Travel See Additional Comments ----1 1/2" gap between concrete and rubber surface. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 89 Playground Area 03B.22 - Other - On-Site Accessible Path of Travel See Additional Comments ----1" gap at 5 locations.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 114 Picnic Table 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.6% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 115 Picnic Table 03B.10 - Running Slope Slope of the accessible route of travel exceeds 1:20. 4.3.7 403.3 1133B.7 .3 -5.2% to 6.5% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 116 Picnic Table Page 5 of 23 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 05 - Eastview ParkReporting: 120 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 21Number of Key Notes for Group 03B - On-Site Path of Travel: Group 01 - Parking Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 01.09 - Stall Dimensions Accessible parking spaces, including van spaces, are not at least 9’ wide and 18’ long with a demarcated access aisle. (Two spaces may share a common aisle; parking space width is measured from the center line of the stripe on one side to the center line of the stripe on the other.) 4.6.3 502.2 1129B.3 items 1 & 2 8'-10" by 18'PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 1 Parking 01.15B - Parking Space Sign Accessible parking space has no reflectorized sign visible from the stall, showing an ISA in white on a blue background. 4.6.4 502.6 1129B.4 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 2 Parking 01.15C - Minimum Fine Sign Accessible parking space has no sign stating "Minimum Fine $250" below the ISA. --1129B.4 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 3 Parking 01.18 - Pavement Sign A 36” square ISA is not painted on the pavement at the rear of the stall. -502.6 1129B.4 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 4 Parking 01.19A - Lettering The words “NO PARKING” is not provided in each access aisle, painted in white, 12” high letters. --1129B.3 items 1 & 2 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 5 Parking Page 6 of 23 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 05 - Eastview ParkReporting: 120 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 01 - Parking Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 01.19B - Tow- away Sign A California tow-away sign is not posted in a conspicuous place at each entrance to off–street parking lot, or immediately adjacent to and visible from each accessible stall. --1129B.4 Non-compliant tow-away sign, the term "Handicapped" is used. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 6 Parking 01.19C - Tow- away Sign - Contact Information California tow-away sign does not include contact information. --1129B.4 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 7 Parking 01.13 - Level Surface The accessible parking spaces and access aisles are not level (slope is greater than 2%). 4.6.3 502.4; advisory 502.4 1129B.3 items 3 & 4 2.6% to 4.2% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 8 Parking 8Number of Key Notes for Group 01 - Parking: Group 30 - Parks Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 30.06E - Outdoor Recreation Access Route (ORAR) Segment - Cross Slope Cross slope of the access route segment exceeds 3.33%. Exception: Cross slopes of 5% maximum are permitted to ensure proper drainage. ---1999 ADAAG- 16.3.7.1 5.1% to 6.9% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 26 Trail 30.06A - Outdoor Recreation Access Route (ORAR) Segment - Running Slope Running slope of access route segment in the direction of travel does not comply with the following: a. 5% or less for any distance. b. From 5.1% to 8.33% for 50' maximum. c. From 8.34% to 10% for 30' maximum. ---1999 ADAAG- 16.3.7.2 .1; 16.3.7.2 .2; 16.3.7.2 .3 5.4% to 8.6% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 27 Trail Page 7 of 23 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 05 - Eastview ParkReporting: 120 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 30 - Parks Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 30.06E - Outdoor Recreation Access Route (ORAR) Segment - Cross Slope Cross slope of the access route segment exceeds 3.33%. Exception: Cross slopes of 5% maximum are permitted to ensure proper drainage. ---1999 ADAAG- 16.3.7.1 3.6% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 28 Trail 30.06E - Outdoor Recreation Access Route (ORAR) Segment - Cross Slope Cross slope of the access route segment exceeds 3.33%. Exception: Cross slopes of 5% maximum are permitted to ensure proper drainage. ---1999 ADAAG- 16.3.7.1 3.4% CS. & 4.1% at two locations. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 29 Trail 30.68 - Other - Parks See Additional Comments ----Trip hazards at 7 locations.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 30 Trail 30.06E - Outdoor Recreation Access Route (ORAR) Segment - Cross Slope Cross slope of the access route segment exceeds 3.33%. Exception: Cross slopes of 5% maximum are permitted to ensure proper drainage. ---1999 ADAAG- 16.3.7.1 3.9% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 31 Trail 30.06A - Outdoor Recreation Access Route (ORAR) Segment - Running Slope Running slope of access route segment in the direction of travel does not comply with the following: a. 5% or less for any distance. b. From 5.1% to 8.33% for 50' maximum. c. From 8.34% to 10% for 30' maximum. ---1999 ADAAG- 16.3.7.2 .1; 16.3.7.2 .2; 16.3.7.2 .3 5.1% to 9.7% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 32 Trail Page 8 of 23 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 05 - Eastview ParkReporting: 120 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 30 - Parks Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 30.06C - Outdoor Recreation Access Route (ORAR) Surface The surface of the access route is not firm or stable. ---1999 ADAAG- 16.3.1 Mulch surface at trail.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 33 Trail 30.06E - Outdoor Recreation Access Route (ORAR) Segment - Cross Slope Cross slope of the access route segment exceeds 3.33%. Exception: Cross slopes of 5% maximum are permitted to ensure proper drainage. ---1999 ADAAG- 16.3.7.1 4.1% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 34 Trail 30.06E - Outdoor Recreation Access Route (ORAR) Segment - Cross Slope Cross slope of the access route segment exceeds 3.33%. Exception: Cross slopes of 5% maximum are permitted to ensure proper drainage. ---1999 ADAAG- 16.3.7.1 4.2% to 4.3% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 35 Trail 30.06A - Outdoor Recreation Access Route (ORAR) Segment - Running Slope Running slope of access route segment in the direction of travel does not comply with the following: a. 5% or less for any distance. b. From 5.1% to 8.33% for 50' maximum. c. From 8.34% to 10% for 30' maximum. ---1999 ADAAG- 16.3.7.2 .1; 16.3.7.2 .2; 16.3.7.2 .3 5.3% to 11.9% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 36 Trail Page 9 of 23 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 05 - Eastview ParkReporting: 120 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 30 - Parks Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 30.06B - Outdoor Recreation Access Route (ORAR) Resting Space Resting space does not comply with 1999 ADAAG Section 16.3.8 (Resting intervals shall be 60" min. in length, shall have a width at least as wide as the access route and have a slope of 3.33% or less in any direction. The installation of resting spaces is required as follows: Percent slope, maximum length, Rest interval: 0% to 5.0%, No restriction, No restriction; 5.1% to 8.33%, 50', Every 50'; 8.34% to 10%, 30', Every 30'.) ---1999 ADAAG- 16.3.8 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 37 Trail 30.68 - Other - Parks See Additional Comments ----2" change in level at walkway/trail merger. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 38 Trail 30.68 - Other - Parks See Additional Comments ----Accessible path of travel to dog waste bags not provided, at three locations. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 39 Trail 30.68 - Other - Parks See Additional Comments ----61" to dog waste bags at two locations. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 40 Trail 30.33 - Tabletop Height Distance from the tabletop to the ground is not between 28" and 34". 4.32.4 902.3 1122B.4 -36" high.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 41 Trail 30.32 - 36" Aisle Width Standard Around the picnic table, there is less than 36" clear space measured from the seat. ---1999 ADAAG- 16.5.5 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 42 Trail Page 10 of 23 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 05 - Eastview ParkReporting: 120 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 30 - Parks Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 30.28 - Picnic Site - Surface Slope The accessible picnic site is located on a surface area with slope greater than 2% in some or all directions.(1999 ADAAG: 3% slope is allowed when necessary for drainage). 4.3.7 403.3 -1999 ADAAG- 16.5.7 6.8% slope, uneven landing.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 43 Trail 30.33 - Tabletop Height Distance from the tabletop to the ground is not between 28" and 34". 4.32.4 902.3 1122B.4 -36" high.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 44 Trail 30.32 - 36" Aisle Width Standard Around the picnic table, there is less than 36" clear space measured from the seat. ---1999 ADAAG- 16.5.5 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 45 Trail 30.28 - Picnic Site - Surface Slope The accessible picnic site is located on a surface area with slope greater than 2% in some or all directions.(1999 ADAAG: 3% slope is allowed when necessary for drainage). 4.3.7 403.3 -1999 ADAAG- 16.5.7 7.0% slope.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 46 Trail 30.47 - Trash & Recycling Receptacles - Location The picnic area does not provide a trash receptacle at the site or on an accessible route to the site. ---1999 ADAAG- 16.8.1 Accessible path of travel to trash and recycling bins not provided. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 47 Trail 30.47 - Trash & Recycling Receptacles - Location The picnic area does not provide a trash receptacle at the site or on an accessible route to the site. ---1999 ADAAG- 16.8.1 Accessible path of travel to trash and recycling bins not provided, at two locations. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 48 Trail 30.32 - 36" Aisle Width Standard Around the picnic table, there is less than 36" clear space measured from the seat. ---1999 ADAAG- 16.5.5 13" aisle around picnic table.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 113 Picnic Table 24Number of Key Notes for Group 30 - Parks: Page 11 of 23 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 05 - Eastview ParkReporting: 120 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 31 - Play Areas Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 31.21 - Transfer Platforms - Height Platforms surfaces are not 11" min. and 24" maximum from the clear ground or floor space. -1008.3. 1.2 -2000 ADAAG- 15.6.5.1 .2 4" high.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 117 Playground Area 31.30B - Play Components - Clear Floor or Ground Space Slope The clear floor or ground space has a slope greater than 2% in some or all directions. -1008.4. 2; 305.2; 305.3 -2000 ADAAG- 15.6.6.2 ; PRC 5410- 5411 2.3% to 4.3% slope.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 118 Playground Area 31.34 - Play Areas - Ground Surfaces Ground surfaces along accessible routes, clear floor or ground spaces, or turning spaces are not compliant. -1008.2. 6 -2000 ADAAG- 15.6.7; PRC 5410- 5411; H&SC 115725 Sand on surface.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 119 Playground Area 31.38 - Other - Play Areas See Additional Comments ----3" - 7" drop along playground area. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 120 Playground Area 4Number of Key Notes for Group 31 - Play Areas: Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation Page 12 of 23 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 05 - Eastview ParkReporting: 120 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.30A - Wall- Mounted Protruding Objects Wall-mounted object(s) with leading edges between 27 and 80” from the floor project more than 4" into the pathway. (Wall mounted objects with leading edges at or below 27” may project any amount as long as the required clear width of an accessible route is not reduced.) 4.4.1 307.2; Fig. 307.2 1133B.8 .6.1 -Hand dryer protrudes 6 1/2" at 41" AFF. PV - Public/Visitor Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 59 Men's Restroom 14.30A - Wall- Mounted Protruding Objects Wall-mounted object(s) with leading edges between 27 and 80” from the floor project more than 4" into the pathway. (Wall mounted objects with leading edges at or below 27” may project any amount as long as the required clear width of an accessible route is not reduced.) 4.4.1 307.2; Fig. 307.2 1133B.8 .6.1 -Hand dryer protrudes 6 1/2" at 41" AFF. PV - Public/Visitor Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 92 Women's Restroom 2Number of Key Notes for Group 14 - Rooms and Spaces: Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -11 LBF., (fire rated door).PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 51 Men's Restroom 16.13A - Men's RR Geometric Symbol Signage - Triangle Doorway leading to a men’s toilet room is not identified by an equilateral triangle 1/4" thick with edges 12” long. OR Equilateral triangle is provided, however it is accompanied by words in raised characters and Braille. (ADA and CBC Standards require a separate sign with raised characters and Braille mounted on the wall adjacent to the latch side of the door.) --1115B.6 -Geometric sign on wrong side of door. Geometric sign has Braille. PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 52 Men's Restroom Page 13 of 23 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 05 - Eastview ParkReporting: 120 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.19B - Mounting Height (Visual/Tactile Signs) Sign is not mounted at 60” o.c. AFF to the centerline of the sign. (If the sign contains pictorial symbols (pictograms) or other non- tactile information, mounting height is measured to the centerline of the tactile characters / Braille portion of the sign.) 4.30.6 703.4.1 1117B.5 .7 -61" high Wall Sign.PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 53 Men's Restroom 16.18A - ISA Accessible toilet room is not identified by an ISA. 4.1.3(16 )(b) 216.8 1117B.5 .1(3) -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 54 Men's Restroom 16.21A - Raised Characters and Braille (Visual/Tactile Signs) The raised characters on this sign are not accompanied by California Grade 2 Braille (i.e., the dots within each cell are domed and spaced 1/10” o.c.) 4.30.4 703.2; 703.3 1117B.5 .5 item 1, 1117B.5 .6 -Braille spacing too narrow.PV - Public/Visitor Use D - Minor Code Deviation 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 55 Men's Restroom 16.26A - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -3.5% slope at drain.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 57 Men's Restroom 16.84B - Electric Hand Dryer - Operating Height Mounting height of electric hand dryer's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one electric hand dryer to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one electric hand dryer to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -44" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 58 Men's Restroom 16.78 - Pipe Insulation at Lavatory Drainpipes and hot water pipes are not insulated to protect against contact. 4.19.4 606.5 1115B.4 .3(4) -PV - Public/Visitor Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 60 Men's Restroom Page 14 of 23 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 05 - Eastview ParkReporting: 120 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.79 - Smooth Surfaces at Lavatory The area below the lavatory is not free of sharp or abrasive surfaces. 4.19.4 606.5 1115B.4 .3(4) -PV - Public/Visitor Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 61 Men's Restroom 16.73 - Lavatory Knee Clearance Lavatory does not provide accessible knee clearance (i.e. at least 27” clearance from the floor to the underside of the lavatory, extending 8” min.. measured from the front edge underneath the lavatory back towards the wall). 4.19.2; Fig. 31 306.3; Fig. 306.3 1115B.4 .3(2); Fig 11B- 1D -26" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 62 Men's Restroom 16.76 - Lavatory - Clearance near Sidewall The centerline of the lavatory is not 18” min.. from the nearest sidewall or partition. --1115B.4 .3(2); Fig 11B- 1D -14 1/2" from side wall.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 63 Men's Restroom 16.36A - Stall Width The stall is less than 60” wide.4.17.3; Fig. 30(a) 604.8.1. 1; Advisory 604.8.1. 1; Fig. 604.8.1. 1 1115B.3 .1(4.1) -57 1/2" wide.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 64 Men's Restroom 16.32A - U- Pulls at Stall Door The stall door does not have U-pulls on both sides. 4.13.9; 4.17.5 309.4; 404.27; 604.8.1. 2 1115B.3 .1(4.4) -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 65 Men's Restroom 16.32B - Single- Action Stall Door Hardware The stall door's locking mechanism is not operable with one hand. OR It is not operable without tight grasping, pinching, or twisting of the wrist. 4.13.9; 4.17.5 309.4; 404.2.7; Advisory 404.2.7 1117B.6 (4) -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 66 Men's Restroom Page 15 of 23 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 05 - Eastview ParkReporting: 120 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.33 - Self- Closing Stall Door The stall door is not self-closing.4.13.10 604.8.1. 2 1115B.3 .1(4.4) -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 67 Men's Restroom 16.47A - WC Location from Sidewall The centerline of the WC is not 18” absolute from a wall or partition. 4.22.4 -1115B.4 .1(1) -18 1/2" from side wall.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 68 Men's Restroom 16.37 - Maneuvering Space - Side Entry Stall Where the stall has a side entry stall door, a 60” square clear space is not provided in front of the WC. 4.17.3; Fig. 30(a) 404.2.4. 1; Table 404.2.4. 1; Fig. 404.2.4. 1 1115B.3 .1(4.2) -57 1/2".PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 69 Men's Restroom 16.49B - WC Flush Controls - Location Flush controls are not located on the wide side of the WC where the clear floor space is provided. 4.16.5 604.6; Advisory 604.6 1115B.4 .1(5); Fig. 11B-1A -Flush above WC.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 70 Men's Restroom 16.53 - SC Dispenser Height Mounting height of seat cover dispenser's highest operable part exceeds 40" AFF. 4.22.7; 4.27.3; 4.2.5; 4.2.6 -1115B.8 .3 -55" AFF behind water closet.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 71 Men's Restroom 16.85A - Clear Floor Space at Dispensers There is no clear floor space at least 30” x 48” in front of the dispenser to allow either a forward or a parallel approach to the dispenser. (Where provided, at least one dispenser of each type shall be accessible.) 4.27.2; 4.2.4 305.3 1117B.6 (2); 1118B.4 -SCD behind WC.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 72 Men's Restroom Page 16 of 23 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 05 - Eastview ParkReporting: 120 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.50 - TP Dispenser - Location - Pre- 2007 CBC Facility Location of the toilet paper dispenser does not comply with the Standard in effect at the time of construction. (The 2001 CBC required toilet tissue dispensers located on the wall within 12" of the front edge of the toilet seat, measured to the centerline of the dispenser; mounted below the grab bar; and centered at a min. height of 19" AFF.) 4.16.6; Fig. 29(b) 604.7; Advisory 604.7; Fig. 604.7 --PTD on transfer side.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 73 Men's Restroom 16.56 - Grab Bar Wall Clearance The space between the grab bar and the wall is not 1-1/2” absolute. 4.17.6, 4.26.2; Fig. 39 609.3 1115B.7 .1; Fig. 11B-1C -1 1/4".PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 74 Men's Restroom 16.55A - Side Grab Bar Height Side grab bar is not centered at 33" AFF. (ADA Standards require side grab bars to be centered from 33" to 36" AFF; CBC Standards require side grab bars to be centered at 33" AFF.) 4.17.6; Figs. 29 & 30 604.5; Advisory 604.5; 604.5.2; Fig. 604.5.2; 609.4 1115B.4 .1(3.1); Fig. 11B-1A -32" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 75 Men's Restroom 16.55B - Back Grab Bar Height - Non- Tank-Type WC At non-tank-type WC, back grab bar is not centered at 33" AFF. (ADA Standards require back grab bars to be centered from 33" to 36" AFF; CBC Standards require back grab bars to be centered at 33" AFF.) 4.17.6; Figs. 29 & 30 604.5; Advisory 604.5; 609.4 1115B.4 .1(3.2); Fig. 11B-1A -32" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 76 Men's Restroom 16.80 - Faucet Operation at Lavatory The faucet is not compliant. (Accessible faucets shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.19.5; 4.27.4 309.4; 606.4 1115B.4 .3(1) -Operating force greater than 5 LBF. PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 77 Men's Restroom Page 17 of 23 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 05 - Eastview ParkReporting: 120 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.81 - Lavatory Faucet Operation - Min. 10 Second Standard Self-closing valve remains open for less than 10 seconds. 4.19.5 606.4 1115B.4 .3(1) -1 second.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 78 Men's Restroom 16.65A - Wall- Hung Urinal - Rim Projection from Wall The wall-hung urinal's elongated rim does not project 14" min.. to 17" max.. from the wall. 4.18.2 605.2; Fig. 605.2(a) 1115B.4 .2(1) -21" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 79 Men's Restroom 16.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -10 LBF., (fire rated door).PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 84 Women's Restroom 16.13B - Women's RR Geometric Symbol Signage - Circle Doorway leading to a women’s toilet room is not identified by a circle, 1/4" thick and 12” in diameter. OR Circle is provided, however it is accompanied by words in raised characters and Braille. (ADA and CBC Standards require a separate sign with raised characters and Braille mounted on the wall adjacent to the latch side of the door.) --1115B.6 -Geometric sign on wrong side of the door. Geometric sign has Braille. PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 85 Women's Restroom 16.19A - Mounting Location (Visual/Tactile Signs) Sign is not mounted on the wall adjacent to the latch side of the door. OR At double leaf doors, the sign is not placed on the nearest adjacent wall. 4.30.6 703.4.2; Fig. 703.4.2 1117B.5 .7 -62" high Wall Sign.PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 86 Women's Restroom 16.18A - ISA Accessible toilet room is not identified by an ISA. 4.1.3(16 )(b) 216.8 1117B.5 .1(3) -No ISA.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 87 Women's Restroom Page 18 of 23 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 05 - Eastview ParkReporting: 120 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.21A - Raised Characters and Braille (Visual/Tactile Signs) The raised characters on this sign are not accompanied by California Grade 2 Braille (i.e., the dots within each cell are domed and spaced 1/10” o.c.) 4.30.4 703.2; 703.3 1117B.5 .5 item 1, 1117B.5 .6 -Braille spacing too narrow.PV - Public/Visitor Use D - Minor Code Deviation 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 88 Women's Restroom 16.26A - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -5% slope at drain.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 90 Women's Restroom 16.84B - Electric Hand Dryer - Operating Height Mounting height of electric hand dryer's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one electric hand dryer to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one electric hand dryer to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -43 1/2" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 91 Women's Restroom 16.78 - Pipe Insulation at Lavatory Drainpipes and hot water pipes are not insulated to protect against contact. 4.19.4 606.5 1115B.4 .3(4) -PV - Public/Visitor Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 93 Women's Restroom 16.79 - Smooth Surfaces at Lavatory The area below the lavatory is not free of sharp or abrasive surfaces. 4.19.4 606.5 1115B.4 .3(4) -PV - Public/Visitor Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 94 Women's Restroom 16.73 - Lavatory Knee Clearance Lavatory does not provide accessible knee clearance (i.e. at least 27” clearance from the floor to the underside of the lavatory, extending 8” min.. measured from the front edge underneath the lavatory back towards the wall). 4.19.2; Fig. 31 306.3; Fig. 306.3 1115B.4 .3(2); Fig 11B- 1D -26" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 95 Women's Restroom Page 19 of 23 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 05 - Eastview ParkReporting: 120 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.76 - Lavatory - Clearance near Sidewall The centerline of the lavatory is not 18” min.. from the nearest sidewall or partition. --1115B.4 .3(2); Fig 11B- 1D -16" from side wall.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 96 Women's Restroom 16.36A - Stall Width The stall is less than 60” wide.4.17.3; Fig. 30(a) 604.8.1. 1; Advisory 604.8.1. 1; Fig. 604.8.1. 1 1115B.3 .1(4.1) -58" wide.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 97 Women's Restroom 16.27A - 60” Wide Circle or T- Shaped Maneuvering Space The toilet room does not include an unobstructed turning space (a 60” diameter, 27" high circle or T-shaped space). (Note: The clear floor space of fixtures and controls, the accessible path of travel, and the turning space may overlap.) 4.22.3; Fig 3 304.3.2; Fig.304. 3.2; 603.2.1 1115B.3 .1(1); 1115B.3 .2(1) -55".PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 98 Women's Restroom 16.32A - U- Pulls at Stall Door The stall door does not have U-pulls on both sides. 4.13.9; 4.17.5 309.4; 404.27; 604.8.1. 2 1115B.3 .1(4.4) -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 99 Women's Restroom 16.32B - Single- Action Stall Door Hardware The stall door's locking mechanism is not operable with one hand. OR It is not operable without tight grasping, pinching, or twisting of the wrist. 4.13.9; 4.17.5 309.4; 404.2.7; Advisory 404.2.7 1117B.6 (4) -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 100 Women's Restroom Page 20 of 23 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 05 - Eastview ParkReporting: 120 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.33 - Self- Closing Stall Door The stall door is not self-closing.4.13.10 604.8.1. 2 1115B.3 .1(4.4) -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 101 Women's Restroom 16.47A - WC Location from Sidewall The centerline of the WC is not 18” absolute from a wall or partition. 4.22.4 -1115B.4 .1(1) -18 1/2" from side wall.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 102 Women's Restroom 16.40 - Stall Door Location - End-Opening Stall In an end-opening stall, the stall door is in front of the WC and not in front of the side transfer space. (ADA/CBC Standards require the door to be located in front of the side transfer space and diagonal to the WC, with a maximum stile width of 4".) 4.17.3; Fig. 30(a) 604.8.1. 2; Fig. 604.8.1. 2 1115B.3 .1(4.3); Fig. 11B-1A -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 103 Women's Restroom 16.49B - WC Flush Controls - Location Flush controls are not located on the wide side of the WC where the clear floor space is provided. 4.16.5 604.6; Advisory 604.6 1115B.4 .1(5); Fig. 11B-1A -Flush controls above WC.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 104 Women's Restroom 16.53 - SC Dispenser Height Mounting height of seat cover dispenser's highest operable part exceeds 40" AFF. 4.22.7; 4.27.3; 4.2.5; 4.2.6 -1115B.8 .3 -55" AFF behind water closet.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 105 Women's Restroom 16.85A - Clear Floor Space at Dispensers There is no clear floor space at least 30” x 48” in front of the dispenser to allow either a forward or a parallel approach to the dispenser. (Where provided, at least one dispenser of each type shall be accessible.) 4.27.2; 4.2.4 305.3 1117B.6 (2); 1118B.4 -SCD behind water closet.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 106 Women's Restroom Page 21 of 23 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 05 - Eastview ParkReporting: 120 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.50 - TP Dispenser - Location - Pre- 2007 CBC Facility Location of the toilet paper dispenser does not comply with the Standard in effect at the time of construction. (The 2001 CBC required toilet tissue dispensers located on the wall within 12" of the front edge of the toilet seat, measured to the centerline of the dispenser; mounted below the grab bar; and centered at a min. height of 19" AFF.) 4.16.6; Fig. 29(b) 604.7; Advisory 604.7; Fig. 604.7 --TPD on transfer side.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 107 Women's Restroom 16.56 - Grab Bar Wall Clearance The space between the grab bar and the wall is not 1-1/2” absolute. 4.17.6, 4.26.2; Fig. 39 609.3 1115B.7 .1; Fig. 11B-1C -1 1/4" clearance.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 108 Women's Restroom 16.55A - Side Grab Bar Height Side grab bar is not centered at 33" AFF. (ADA Standards require side grab bars to be centered from 33" to 36" AFF; CBC Standards require side grab bars to be centered at 33" AFF.) 4.17.6; Figs. 29 & 30 604.5; Advisory 604.5; 604.5.2; Fig. 604.5.2; 609.4 1115B.4 .1(3.1); Fig. 11B-1A -32" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 109 Women's Restroom 16.55B - Back Grab Bar Height - Non- Tank-Type WC At non-tank-type WC, back grab bar is not centered at 33" AFF. (ADA Standards require back grab bars to be centered from 33" to 36" AFF; CBC Standards require back grab bars to be centered at 33" AFF.) 4.17.6; Figs. 29 & 30 604.5; Advisory 604.5; 609.4 1115B.4 .1(3.2); Fig. 11B-1A -32" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 110 Women's Restroom 16.80 - Faucet Operation at Lavatory The faucet is not compliant. (Accessible faucets shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.19.5; 4.27.4 309.4; 606.4 1115B.4 .3(1) -Operating force greater than 5 LBF. PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 111 Women's Restroom Page 22 of 23 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 05 - Eastview ParkReporting: 120 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.81 - Lavatory Faucet Operation - Min. 10 Second Standard Self-closing valve remains open for less than 10 seconds. 4.19.5 606.4 1115B.4 .3(1) -1 second.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 112 Women's Restroom 54Number of Key Notes for Group 16 - Toilet Facilities: 120Number of Key Notes for Facility 05 - Eastview Park: 120Total Number of Key Notes for All Groups: Page 23 of 23 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA