Loading...
Curb Ramps_ComplianceReport_20130509-120113Facility ID # Curb RampsReporting: 118 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 04 - Curb Ramps Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 04.02 - Slope Slope of the curb ramp exceeds 8.33% (or the least possible compliant slope). 4.7.2; 4.8.2 405.2; Advisory 405.2 1127B.5 item 3 2005 PROWA G- R303.2. 1.1; R303.2. 2.1 11.3% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 1 Basswood Ave./Fond Du Lac NW Corner 04.07B - Side Flare Slope (8.33% Max. Requirement) Where the landing at the top of the ramp is less than 48” deep and wheelchair users must use the side flares for access, the flared sides have a slope greater than 8.33% (measured along the curb). Fig. 12(a) 406.3; Fig. 406.3 1127B.5 item 4 -17.2% and 27.8% slope.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 3 Basswood Ave./Fond Du Lac NW Corner 04.05 - Width The width of the curb ramp, not including the flared sides, is less than 48”. 4.7.3 406.1; 405.5 1127B.5 item 2 2005 PROWA G- R303.3. 1 40" wide Curb Ramp.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 4 Basswood Ave./Fond Du Lac NW Corner 04.09A - Grooved Border Requirement Curb ramp does not have a 12” wide grooved border around upper edges of curb ramp and flares to indicate transition from sidewalk to curb ramp. --1127B.5 item 6 -Grooved border @ 12 1/2" wide. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 5 Basswood Ave./Fond Du Lac NW Corner 04.10 - Detectable Warning Requirement Regardless of slope, the curb ramp does not have a detectable warning. 4.7.7; 4.29.2 705.1; Fig. 705.1 1127B.5 item 7 2005 PROWA G- R303.3. 2 Not provided.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 6 Basswood Ave./Fond Du Lac NW Corner 04.03 - Transition The transition from the curb ramp to the road or gutter is not flush or free of abrupt changes. 4.7.2 406.2; Fig. 406.2 1127B.5 item 3 2005 PROWA G- R301.5. 1 1/2" transition.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 10 Basswood Ave./Fond Du Lac NE Corner Page 1 of 21 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # Curb RampsReporting: 118 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 04 - Curb Ramps Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 04.04 - Counter Slope The running slopes of the road, gutter or accessible route adjoining the ramp exceed 5%. 4.7.2 406.2 1127B.5 item 3 2005 PROWA G- R303.3. 5 10.6% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 11 Basswood Ave./Fond Du Lac NE Corner 04.05 - Width The width of the curb ramp, not including the flared sides, is less than 48”. 4.7.3 406.1; 405.5 1127B.5 item 2 2005 PROWA G- R303.3. 1 38" wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 12 Basswood Ave./Fond Du Lac NE Corner 04.07B - Side Flare Slope (8.33% Max. Requirement) Where the landing at the top of the ramp is less than 48” deep and wheelchair users must use the side flares for access, the flared sides have a slope greater than 8.33% (measured along the curb). Fig. 12(a) 406.3; Fig. 406.3 1127B.5 item 4 -11.2% & 31.2%.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 13 Basswood Ave./Fond Du Lac NE Corner 04.10 - Detectable Warning Requirement Regardless of slope, the curb ramp does not have a detectable warning. 4.7.7; 4.29.2 705.1; Fig. 705.1 1127B.5 item 7 2005 PROWA G- R303.3. 2 Not provided.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 14 Basswood Ave./Fond Du Lac NE Corner 04.09A - Grooved Border Requirement Curb ramp does not have a 12” wide grooved border around upper edges of curb ramp and flares to indicate transition from sidewalk to curb ramp. --1127B.5 item 6 -12 1/2" wide.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 17 Basswood Ave./Fond Du Lac NE Corner 04.07B - Side Flare Slope (8.33% Max. Requirement) Where the landing at the top of the ramp is less than 48” deep and wheelchair users must use the side flares for access, the flared sides have a slope greater than 8.33% (measured along the curb). Fig. 12(a) 406.3; Fig. 406.3 1127B.5 item 4 -16.6% & 31.1%.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 18 Basswood Ave./Fond Du Lac SW Corner Page 2 of 21 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # Curb RampsReporting: 118 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 04 - Curb Ramps Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 04.10 - Detectable Warning Requirement Regardless of slope, the curb ramp does not have a detectable warning. 4.7.7; 4.29.2 705.1; Fig. 705.1 1127B.5 item 7 2005 PROWA G- R303.3. 2 Not provided.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 19 Basswood Ave./Fond Du Lac SW Corner 04.02 - Slope Slope of the curb ramp exceeds 8.33% (or the least possible compliant slope). 4.7.2; 4.8.2 405.2; Advisory 405.2 1127B.5 item 3 2005 PROWA G- R303.2. 1.1; R303.2. 2.1 10.8% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 23 Basswood Ave./Fond Du Lac SE Corner 04.03 - Transition The transition from the curb ramp to the road or gutter is not flush or free of abrupt changes. 4.7.2 406.2; Fig. 406.2 1127B.5 item 3 2005 PROWA G- R301.5. 1 1" transition.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 24 Basswood Ave./Fond Du Lac SE Corner 04.05 - Width The width of the curb ramp, not including the flared sides, is less than 48”. 4.7.3 406.1; 405.5 1127B.5 item 2 2005 PROWA G- R303.3. 1 40" wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 25 Basswood Ave./Fond Du Lac SE Corner 04.07B - Side Flare Slope (8.33% Max. Requirement) Where the landing at the top of the ramp is less than 48” deep and wheelchair users must use the side flares for access, the flared sides have a slope greater than 8.33% (measured along the curb). Fig. 12(a) 406.3; Fig. 406.3 1127B.5 item 4 -11.1% & 27.4%.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 26 Basswood Ave./Fond Du Lac SE Corner 04.09A - Grooved Border Requirement Curb ramp does not have a 12” wide grooved border around upper edges of curb ramp and flares to indicate transition from sidewalk to curb ramp. --1127B.5 item 6 -8 1/2" wide.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 27 Basswood Ave./Fond Du Lac SE Corner Page 3 of 21 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # Curb RampsReporting: 118 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 04 - Curb Ramps Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 04.10 - Detectable Warning Requirement Regardless of slope, the curb ramp does not have a detectable warning. 4.7.7; 4.29.2 705.1; Fig. 705.1 1127B.5 item 7 2005 PROWA G- R303.3. 2 Not provided.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 31 Basswood Ave./Fond Du Lac SE Corner 04.02 - Slope Slope of the curb ramp exceeds 8.33% (or the least possible compliant slope). 4.7.2; 4.8.2 405.2; Advisory 405.2 1127B.5 item 3 2005 PROWA G- R303.2. 1.1; R303.2. 2.1 11.8% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 32 Verde Ridge/El Rodeo NW Corner 04.04 - Counter Slope The running slopes of the road, gutter or accessible route adjoining the ramp exceed 5%. 4.7.2 406.2 1127B.5 item 3 2005 PROWA G- R303.3. 5 13% counter slope.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 33 Verde Ridge/El Rodeo NW Corner 04.05 - Width The width of the curb ramp, not including the flared sides, is less than 48”. 4.7.3 406.1; 405.5 1127B.5 item 2 2005 PROWA G- R303.3. 1 45" wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 34 Verde Ridge/El Rodeo NW Corner 04.09A - Grooved Border Requirement Curb ramp does not have a 12” wide grooved border around upper edges of curb ramp and flares to indicate transition from sidewalk to curb ramp. --1127B.5 item 6 -13" wide.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 35 Verde Ridge/El Rodeo NW Corner 04.10 - Detectable Warning Requirement Regardless of slope, the curb ramp does not have a detectable warning. 4.7.7; 4.29.2 705.1; Fig. 705.1 1127B.5 item 7 2005 PROWA G- R303.3. 2 Not provided.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 36 Verde Ridge/El Rodeo NW Corner Page 4 of 21 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # Curb RampsReporting: 118 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 04 - Curb Ramps Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 04.02 - Slope Slope of the curb ramp exceeds 8.33% (or the least possible compliant slope). 4.7.2; 4.8.2 405.2; Advisory 405.2 1127B.5 item 3 2005 PROWA G- R303.2. 1.1; R303.2. 2.1 25.2% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 39 Verde Ridge/El Rodeo NE Corner 04.09A - Grooved Border Requirement Curb ramp does not have a 12” wide grooved border around upper edges of curb ramp and flares to indicate transition from sidewalk to curb ramp. --1127B.5 item 6 -13" wide.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 40 Verde Ridge/El Rodeo NE Corner 04.07B - Side Flare Slope (8.33% Max. Requirement) Where the landing at the top of the ramp is less than 48” deep and wheelchair users must use the side flares for access, the flared sides have a slope greater than 8.33% (measured along the curb). Fig. 12(a) 406.3; Fig. 406.3 1127B.5 item 4 -15% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 42 Locklenna Ln./Seaspray Dr. SW Corner 04.09A - Grooved Border Requirement Curb ramp does not have a 12” wide grooved border around upper edges of curb ramp and flares to indicate transition from sidewalk to curb ramp. --1127B.5 item 6 -13" wide.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 43 Locklenna Ln./Seaspray Dr. SW Corner 04.02 - Slope Slope of the curb ramp exceeds 8.33% (or the least possible compliant slope). 4.7.2; 4.8.2 405.2; Advisory 405.2 1127B.5 item 3 2005 PROWA G- R303.2. 1.1; R303.2. 2.1 11.4% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 45 Locklenna Ln./Seaspray Dr. SE Corner 04.07B - Side Flare Slope (8.33% Max. Requirement) Where the landing at the top of the ramp is less than 48” deep and wheelchair users must use the side flares for access, the flared sides have a slope greater than 8.33% (measured along the curb). Fig. 12(a) 406.3; Fig. 406.3 1127B.5 item 4 -10.4% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 46 Locklenna Ln./Seaspray Dr.SE Corner Page 5 of 21 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # Curb RampsReporting: 118 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 04 - Curb Ramps Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 04.09A - Grooved Border Requirement Curb ramp does not have a 12” wide grooved border around upper edges of curb ramp and flares to indicate transition from sidewalk to curb ramp. --1127B.5 item 6 -13" wide.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 47 Locklenna Ln./Seaspray Dr. SE Corner 04.04 - Counter Slope The running slopes of the road, gutter or accessible route adjoining the ramp exceed 5%. 4.7.2 406.2 1127B.5 item 3 2005 PROWA G- R303.3. 5 6.6% counter slope.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 48 Hawthorne Blvd./Dupree Dr. NE Corner 04.07B - Side Flare Slope (8.33% Max. Requirement) Where the landing at the top of the ramp is less than 48” deep and wheelchair users must use the side flares for access, the flared sides have a slope greater than 8.33% (measured along the curb). Fig. 12(a) 406.3; Fig. 406.3 1127B.5 item 4 -13.2% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 49 Hawthorne Blvd./Dupree Dr. NE Corner 04.03 - Transition The transition from the curb ramp to the road or gutter is not flush or free of abrupt changes. 4.7.2 406.2; Fig. 406.2 1127B.5 item 3 2005 PROWA G- R301.5. 1 1/4" transition.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 51 Hawthorne Blvd./Vallon Dr. NW Corner 04.04 - Counter Slope The running slopes of the road, gutter or accessible route adjoining the ramp exceed 5%. 4.7.2 406.2 1127B.5 item 3 2005 PROWA G- R303.3. 5 12.2% counter slope.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 52 Hawthorne Blvd./Vallon Dr. NW Corner 04.05 - Width The width of the curb ramp, not including the flared sides, is less than 48”. 4.7.3 406.1; 405.5 1127B.5 item 2 2005 PROWA G- R303.3. 1 41" wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 53 Hawthorne Blvd./Vallon Dr. NW Corner Page 6 of 21 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # Curb RampsReporting: 118 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 04 - Curb Ramps Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 04.09A - Grooved Border Requirement Curb ramp does not have a 12” wide grooved border around upper edges of curb ramp and flares to indicate transition from sidewalk to curb ramp. --1127B.5 item 6 -11" & 11 1/2" wide.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 54 Hawthorne Blvd./Vallon Dr. NW Corner 04.07B - Side Flare Slope (8.33% Max. Requirement) Where the landing at the top of the ramp is less than 48” deep and wheelchair users must use the side flares for access, the flared sides have a slope greater than 8.33% (measured along the curb). Fig. 12(a) 406.3; Fig. 406.3 1127B.5 item 4 -27.3% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 55 Hawthorne Blvd./Vallon Dr. NW Corner 04.03 - Transition The transition from the curb ramp to the road or gutter is not flush or free of abrupt changes. 4.7.2 406.2; Fig. 406.2 1127B.5 item 3 2005 PROWA G- R301.5. 1 1/4" transition.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 58 Hawthorne Blvd./Vallon Dr. SW Corner 04.04 - Counter Slope The running slopes of the road, gutter or accessible route adjoining the ramp exceed 5%. 4.7.2 406.2 1127B.5 item 3 2005 PROWA G- R303.3. 5 11.2% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 59 Hawthorne Blvd./Vallon Dr. SW Corner 04.05 - Width The width of the curb ramp, not including the flared sides, is less than 48”. 4.7.3 406.1; 405.5 1127B.5 item 2 2005 PROWA G- R303.3. 1 41" wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 60 Hawthorne Blvd./Vallon Dr. SW Corner 04.07B - Side Flare Slope (8.33% Max. Requirement) Where the landing at the top of the ramp is less than 48” deep and wheelchair users must use the side flares for access, the flared sides have a slope greater than 8.33% (measured along the curb). Fig. 12(a) 406.3; Fig. 406.3 1127B.5 item 4 -22.3% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 61 Hawthorne Blvd./Vallon Dr. SW Corner Page 7 of 21 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # Curb RampsReporting: 118 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 04 - Curb Ramps Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 04.04 - Counter Slope The running slopes of the road, gutter or accessible route adjoining the ramp exceed 5%. 4.7.2 406.2 1127B.5 item 3 2005 PROWA G- R303.3. 5 9.7% counter slope.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 63 Hawthorne Blvd./Vallon Dr. SE Corner 04.09A - Grooved Border Requirement Curb ramp does not have a 12” wide grooved border around upper edges of curb ramp and flares to indicate transition from sidewalk to curb ramp. --1127B.5 item 6 -11" wide.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 64 Hawthorne Blvd./Vallon Dr. SE Corner 04.40 - Other - Curb Ramps and Pedestrian Crossings See Additional Comments ----35" deep landing.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 66 Hawthorne Blvd./Vallon Dr. SE Corner 04.03 - Transition The transition from the curb ramp to the road or gutter is not flush or free of abrupt changes. 4.7.2 406.2; Fig. 406.2 1127B.5 item 3 2005 PROWA G- R301.5. 1 1" transition.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 67 Palos Verdes Dr. South/Barken tine Rd. SW Corner 04.05 - Width The width of the curb ramp, not including the flared sides, is less than 48”. 4.7.3 406.1; 405.5 1127B.5 item 2 2005 PROWA G- R303.3. 1 32" wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 68 Palos Verdes Dr. South/Barken tine Rd. SW Corner 04.40 - Other - Curb Ramps and Pedestrian Crossings See Additional Comments ----Top landing not provided.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 69 Palos Verdes Dr. South/Barken tine Rd. SW Corner Page 8 of 21 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # Curb RampsReporting: 118 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 04 - Curb Ramps Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 04.10 - Detectable Warning Requirement Regardless of slope, the curb ramp does not have a detectable warning. 4.7.7; 4.29.2 705.1; Fig. 705.1 1127B.5 item 7 2005 PROWA G- R303.3. 2 Not provided.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 70 Palos Verdes Dr. South/Barken tine Rd. SW Corner 04.09A - Grooved Border Requirement Curb ramp does not have a 12” wide grooved border around upper edges of curb ramp and flares to indicate transition from sidewalk to curb ramp. --1127B.5 item 6 -Not provided.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 71 Palos Verdes Dr. South/Barken tine Rd. SW Corner 04.05 - Width The width of the curb ramp, not including the flared sides, is less than 48”. 4.7.3 406.1; 405.5 1127B.5 item 2 2005 PROWA G- R303.3. 1 45 1/2" wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 72 Palos Verdes Dr. South/Ocean Trail SW Corner 04.09A - Grooved Border Requirement Curb ramp does not have a 12” wide grooved border around upper edges of curb ramp and flares to indicate transition from sidewalk to curb ramp. --1127B.5 item 6 -Not provided.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 73 Palos Verdes Dr. South/Ocean Trail SW Corner 04.10 - Detectable Warning Requirement Regardless of slope, the curb ramp does not have a detectable warning. 4.7.7; 4.29.2 705.1; Fig. 705.1 1127B.5 item 7 2005 PROWA G- R303.3. 2 Not provided around entire curb ramp. PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 74 Palos Verdes Dr. South/Ocean Trail SW Corner 04.40 - Other - Curb Ramps and Pedestrian Crossings See Additional Comments ----2" change in level at decomposed granite pathway. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 75 Palos Verdes Dr. South/Ocean Trail SW Corner Page 9 of 21 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # Curb RampsReporting: 118 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 04 - Curb Ramps Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 04.02 - Slope Slope of the curb ramp exceeds 8.33% (or the least possible compliant slope). 4.7.2; 4.8.2 405.2; Advisory 405.2 1127B.5 item 3 2005 PROWA G- R303.2. 1.1; R303.2. 2.1 11.9% and 13% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 76 Ganado Dr./Flowerrid ge Dr. N Corner 04.02 - Slope Slope of the curb ramp exceeds 8.33% (or the least possible compliant slope). 4.7.2; 4.8.2 405.2; Advisory 405.2 1127B.5 item 3 2005 PROWA G- R303.2. 1.1; R303.2. 2.1 10.4% and 13.6% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 77 Ganado Dr./Flowerrid ge Dr. S Corner 04.02 - Slope Slope of the curb ramp exceeds 8.33% (or the least possible compliant slope). 4.7.2; 4.8.2 405.2; Advisory 405.2 1127B.5 item 3 2005 PROWA G- R303.2. 1.1; R303.2. 2.1 11.7% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 78 Palos Verdes Dr. East/Crest Rd. E Corner 04.03 - Transition The transition from the curb ramp to the road or gutter is not flush or free of abrupt changes. 4.7.2 406.2; Fig. 406.2 1127B.5 item 3 2005 PROWA G- R301.5. 1 1/2" transition.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 79 Palos Verdes Dr. East/Crest Rd. E Corner 04.04 - Counter Slope The running slopes of the road, gutter or accessible route adjoining the ramp exceed 5%. 4.7.2 406.2 1127B.5 item 3 2005 PROWA G- R303.3. 5 7.9% counter slope.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 80 Palos Verdes Dr. East/Crest Rd. E Corner Page 10 of 21 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # Curb RampsReporting: 118 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 04 - Curb Ramps Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 04.10 - Detectable Warning Requirement Regardless of slope, the curb ramp does not have a detectable warning. 4.7.7; 4.29.2 705.1; Fig. 705.1 1127B.5 item 7 2005 PROWA G- R303.3. 2 Not provided.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 81 Palos Verdes Dr. East/Crest Rd. E Corner 04.40 - Other - Curb Ramps and Pedestrian Crossings See Additional Comments ----2.7% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 82 Palos Verdes Dr. East/Crest Rd. E Corner 04.02 - Slope Slope of the curb ramp exceeds 8.33% (or the least possible compliant slope). 4.7.2; 4.8.2 405.2; Advisory 405.2 1127B.5 item 3 2005 PROWA G- R303.2. 1.1; R303.2. 2.1 12.6% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 83 Palos Verdes Dr. East/Crest Rd. W Corner 04.03 - Transition The transition from the curb ramp to the road or gutter is not flush or free of abrupt changes. 4.7.2 406.2; Fig. 406.2 1127B.5 item 3 2005 PROWA G- R301.5. 1 3/4" transition.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 84 Palos Verdes Dr. East/Crest Rd. W Corner 04.09B - Grooved Border - Location A 12” wide grooved border has not been provided on the level surface of the walkway. --1127B.5 item 6 -Grooves are on sloping area of curb ramp. PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 85 Palos Verdes Dr. East/Crest Rd. W Corner 04.10 - Detectable Warning Requirement Regardless of slope, the curb ramp does not have a detectable warning. 4.7.7; 4.29.2 705.1; Fig. 705.1 1127B.5 item 7 2005 PROWA G- R303.3. 2 Not provided.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 86 Palos Verdes Dr. East/Crest Rd. W Corner Page 11 of 21 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # Curb RampsReporting: 118 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 04 - Curb Ramps Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 04.40 - Other - Curb Ramps and Pedestrian Crossings See Additional Comments ----4.6% CS creates puddle..PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 87 Palos Verdes Dr. East/Crest Rd. W Corner 04.02 - Slope Slope of the curb ramp exceeds 8.33% (or the least possible compliant slope). 4.7.2; 4.8.2 405.2; Advisory 405.2 1127B.5 item 3 2005 PROWA G- R303.2. 1.1; R303.2. 2.1 9.1% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 88 Palos Verdes Dr. East/Via Canada NW Corner 04.03 - Transition The transition from the curb ramp to the road or gutter is not flush or free of abrupt changes. 4.7.2 406.2; Fig. 406.2 1127B.5 item 3 2005 PROWA G- R301.5. 1 3/4" transition.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 89 Palos Verdes Dr. East/Via Canada NW Corner 04.04 - Counter Slope The running slopes of the road, gutter or accessible route adjoining the ramp exceed 5%. 4.7.2 406.2 1127B.5 item 3 2005 PROWA G- R303.3. 5 8.5% counter slope.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 90 Palos Verdes Dr. East/Via Canada NW Corner 04.40 - Other - Curb Ramps and Pedestrian Crossings See Additional Comments ----48" bottom landing.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 91 Palos Verdes Dr. East/Via Canada NW Corner 04.40 - Other - Curb Ramps and Pedestrian Crossings See Additional Comments ----Pond.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 92 Palos Verdes Dr. East/Via Canada NW Corner Page 12 of 21 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # Curb RampsReporting: 118 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 04 - Curb Ramps Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 04.10 - Detectable Warning Requirement Regardless of slope, the curb ramp does not have a detectable warning. 4.7.7; 4.29.2 705.1; Fig. 705.1 1127B.5 item 7 2005 PROWA G- R303.3. 2 Not provided.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 93 Palos Verdes Dr. East/Via Canada NW Corner 04.02 - Slope Slope of the curb ramp exceeds 8.33% (or the least possible compliant slope). 4.7.2; 4.8.2 405.2; Advisory 405.2 1127B.5 item 3 2005 PROWA G- R303.2. 1.1; R303.2. 2.1 14.3% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 94 Palos Verdes Dr. East/Via Canada NE Corner 04.06 - Surface The surface of the curb ramp is not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1127B.5 item 5 2005 PROWA G- R301.5 Loose asphalt.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 95 Palos Verdes Dr. East/Via Canada NE Corner 04.07B - Side Flare Slope (8.33% Max. Requirement) Where the landing at the top of the ramp is less than 48” deep and wheelchair users must use the side flares for access, the flared sides have a slope greater than 8.33% (measured along the curb). Fig. 12(a) 406.3; Fig. 406.3 1127B.5 item 4 -13.6% and 21.6%.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 96 Palos Verdes Dr. East/Via Canada NE Corner 04.09A - Grooved Border Requirement Curb ramp does not have a 12” wide grooved border around upper edges of curb ramp and flares to indicate transition from sidewalk to curb ramp. --1127B.5 item 6 -Not provided.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 97 Palos Verdes Dr. East/Via Canada NE Corner 04.10 - Detectable Warning Requirement Regardless of slope, the curb ramp does not have a detectable warning. 4.7.7; 4.29.2 705.1; Fig. 705.1 1127B.5 item 7 2005 PROWA G- R303.3. 2 Not provided.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 98 Palos Verdes Dr. East/Via Canada NE Corner Page 13 of 21 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # Curb RampsReporting: 118 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 04 - Curb Ramps Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 04.40 - Other - Curb Ramps and Pedestrian Crossings See Additional Comments ----7.9% slope at top landing.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 99 Palos Verdes Dr. East/Via Canada NE Corner 04.03 - Transition The transition from the curb ramp to the road or gutter is not flush or free of abrupt changes. 4.7.2 406.2; Fig. 406.2 1127B.5 item 3 2005 PROWA G- R301.5. 1 1" transition.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 100 Palos Verdes Dr. East/Via Canada SE Corner 04.04 - Counter Slope The running slopes of the road, gutter or accessible route adjoining the ramp exceed 5%. 4.7.2 406.2 1127B.5 item 3 2005 PROWA G- R303.3. 5 7.4% counter slope.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 101 Palos Verdes Dr. East/Via Canada SE Corner 04.06 - Surface The surface of the curb ramp is not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1127B.5 item 5 2005 PROWA G- R301.5 Curb ramp has deteriorated.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 102 Palos Verdes Dr. East/Via Canada SE Corner 04.07B - Side Flare Slope (8.33% Max. Requirement) Where the landing at the top of the ramp is less than 48” deep and wheelchair users must use the side flares for access, the flared sides have a slope greater than 8.33% (measured along the curb). Fig. 12(a) 406.3; Fig. 406.3 1127B.5 item 4 -13.2%.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 103 Palos Verdes Dr. East/Via Canada SE Corner 04.09A - Grooved Border Requirement Curb ramp does not have a 12” wide grooved border around upper edges of curb ramp and flares to indicate transition from sidewalk to curb ramp. --1127B.5 item 6 -Not provided.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 104 Palos Verdes Dr. East/Via Canada SE Corner Page 14 of 21 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # Curb RampsReporting: 118 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 04 - Curb Ramps Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 04.10 - Detectable Warning Requirement Regardless of slope, the curb ramp does not have a detectable warning. 4.7.7; 4.29.2 705.1; Fig. 705.1 1127B.5 item 7 2005 PROWA G- R303.3. 2 Not provided.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 105 Palos Verdes Dr. East/Via Canada SE Corner 04.40 - Other - Curb Ramps and Pedestrian Crossings See Additional Comments ----3.2% slope at top landing.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 106 Palos Verdes Dr. East/Via Canada SE Corner 04.40 - Other - Curb Ramps and Pedestrian Crossings See Additional Comments ----Existing assessment survey by Priority Engineering, Inc. with an estimated Corrective Action cost of $149,349.83 per year. (12 years = $1,792,198) PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 107 Existing Assessment 04.40 - Other - Curb Ramps and Pedestrian Crossings See Additional Comments ----Existing assessment survey by Priority Engineering, Inc. with an estimated Corrective Action cost of $149,349.83 per year. (12 years = $1,792,198) PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 108 Existing Assessment 04.40 - Other - Curb Ramps and Pedestrian Crossings See Additional Comments ----Existing assessment survey by Priority Engineering, Inc. with an estimated Corrective Action cost of $149,349.83 per year. (12 years = $1,792,198) PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 109 Existing Assessment 04.40 - Other - Curb Ramps and Pedestrian Crossings See Additional Comments ----Existing assessment survey by Priority Engineering, Inc. with an estimated Corrective Action cost of $149,349.83 per year. (12 years = $1,792,198) PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 110 Existing Assessment Page 15 of 21 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # Curb RampsReporting: 118 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 04 - Curb Ramps Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 04.40 - Other - Curb Ramps and Pedestrian Crossings See Additional Comments ----Existing assessment survey by Priority Engineering, Inc. with an estimated Corrective Action cost of $149,349.83 per year. (12 years = $1,792,198) PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 111 Existing Assessment 04.40 - Other - Curb Ramps and Pedestrian Crossings See Additional Comments ----Existing assessment survey by Priority Engineering, Inc. with an estimated Corrective Action cost of $149,349.83 per year. (12 years = $1,792,198) PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 112 Existing Assessment 04.40 - Other - Curb Ramps and Pedestrian Crossings See Additional Comments ----Existing assessment survey by Priority Engineering, Inc. with an estimated Corrective Action cost of $149,349.83 per year. (12 years = $1,792,198) PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 113 Existing Assessment 04.40 - Other - Curb Ramps and Pedestrian Crossings See Additional Comments ----Existing assessment survey by Priority Engineering, Inc. with an estimated Corrective Action cost of $149,349.83 per year. (12 years = $1,792,198) PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 114 Existing Assessment 04.40 - Other - Curb Ramps and Pedestrian Crossings See Additional Comments ----Existing assessment survey by Priority Engineering, Inc. with an estimated Corrective Action cost of $149,349.83 per year. (12 years = $1,792,198) PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 115 Existing Assessment 04.40 - Other - Curb Ramps and Pedestrian Crossings See Additional Comments ----Existing assessment survey by Priority Engineering, Inc. with an estimated Corrective Action cost of $149,349.83 per year. (12 years = $1,792,198) PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 116 Existing Assessment Page 16 of 21 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # Curb RampsReporting: 118 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 04 - Curb Ramps Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 04.40 - Other - Curb Ramps and Pedestrian Crossings See Additional Comments ----Existing assessment survey by Priority Engineering, Inc. with an estimated Corrective Action cost of $149,349.83 per year. (12 years = $1,792,198) PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 117 Existing Assessment 04.40 - Other - Curb Ramps and Pedestrian Crossings See Additional Comments ----Existing assessment survey by Priority Engineering, Inc. with an estimated Corrective Action cost of $149,349.83 per year. (12 years = $1,792,198) PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 118 Existing Assessment 97Number of Key Notes for Group 04 - Curb Ramps: Group 03A - Public Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03A.07A - Cross Slope (PAR) Cross slope of the pedestrian access route exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 2005 PROWA G- R301.4. 1 4.9% CS at Curb Ramp PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 2 Basswood Ave./Fond Du Lac NW Corner 03A.08 - Running Slope (PAR) Slope of the pedestrian access route exceeds 1:20. Or slope of the pedestrian access route contained within a street or highway border exceeds the grade of the adjacent roadway. (1:20 requirement does not apply to compliant ramps or where slope of the pedestrian access route contained within a street or highway border does not exceed the grade of the adjacent roadway.) 4.3.7 403.3 1133B.7 .3 2005 PROWA G- R301.4. 2 6% slope.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 7 Basswood Ave./Fond Du Lac NW Corner Page 17 of 21 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # Curb RampsReporting: 118 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03A - Public Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03A.02A - Width Accessible route of travel is less than 48” wide (note: 48" wide requirement does not apply to doorways or gates). 4.3.3 403.5.1 1133B.7 .1 2005 PROWA G- R301.3. 1 32"wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 8 Basswood Ave./Fond Du Lac NW Corner 03A.07A - Cross Slope (PAR) Cross slope of the pedestrian access route exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 2005 PROWA G- R301.4. 1 10.4% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 9 Basswood Ave./Fond Du Lac NE Corner 03A.02A - Width Accessible route of travel is less than 48” wide (note: 48" wide requirement does not apply to doorways or gates). 4.3.3 403.5.1 1133B.7 .1 2005 PROWA G- R301.3. 1 36" wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 15 Basswood Ave./Fond Du Lac NE Corner 03A.08 - Running Slope (PAR) Slope of the pedestrian access route exceeds 1:20. Or slope of the pedestrian access route contained within a street or highway border exceeds the grade of the adjacent roadway. (1:20 requirement does not apply to compliant ramps or where slope of the pedestrian access route contained within a street or highway border does not exceed the grade of the adjacent roadway.) 4.3.7 403.3 1133B.7 .3 2005 PROWA G- R301.4. 2 6.8% CS & 12.3% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 16 Basswood Ave./Fond Du Lac NE Corner 03A.02A - Width Accessible route of travel is less than 48” wide (note: 48" wide requirement does not apply to doorways or gates). 4.3.3 403.5.1 1133B.7 .1 2005 PROWA G- R301.3. 1 34" wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 20 Basswood Ave./Fond Du Lac SW Corner Page 18 of 21 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # Curb RampsReporting: 118 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03A - Public Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03A.07A - Cross Slope (PAR) Cross slope of the pedestrian access route exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 2005 PROWA G- R301.4. 1 2.3% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 21 Basswood Ave./Fond Du Lac SW Corner 03A.07A - Cross Slope (PAR) Cross slope of the pedestrian access route exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 2005 PROWA G- R301.4. 1 7.4% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 22 Basswood Ave./Fond Du Lac SW Corner 03A.02A - Width Accessible route of travel is less than 48” wide (note: 48" wide requirement does not apply to doorways or gates). 4.3.3 403.5.1 1133B.7 .1 2005 PROWA G- R301.3. 1 35" wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 28 Basswood Ave./Fond Du Lac SE Corner 03A.07A - Cross Slope (PAR) Cross slope of the pedestrian access route exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 2005 PROWA G- R301.4. 1 10.8% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 29 Basswood Ave./Fond Du Lac SE Corner 03A.08 - Running Slope (PAR) Slope of the pedestrian access route exceeds 1:20. Or slope of the pedestrian access route contained within a street or highway border exceeds the grade of the adjacent roadway. (1:20 requirement does not apply to compliant ramps or where slope of the pedestrian access route contained within a street or highway border does not exceed the grade of the adjacent roadway.) 4.3.7 403.3 1133B.7 .3 2005 PROWA G- R301.4. 2 4.8% CS & 11.8% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 30 Basswood Ave./Fond Du Lac SE Corner Page 19 of 21 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # Curb RampsReporting: 118 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03A - Public Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03A.07A - Cross Slope (PAR) Cross slope of the pedestrian access route exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 2005 PROWA G- R301.4. 1 8.9% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 37 Verde Ridge/El Rodeo NW Corner 03A.08 - Running Slope (PAR) Slope of the pedestrian access route exceeds 1:20. Or slope of the pedestrian access route contained within a street or highway border exceeds the grade of the adjacent roadway. (1:20 requirement does not apply to compliant ramps or where slope of the pedestrian access route contained within a street or highway border does not exceed the grade of the adjacent roadway.) 4.3.7 403.3 1133B.7 .3 2005 PROWA G- R301.4. 2 2.1% RS at turning area.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 38 Verde Ridge/El Rodeo NW Corner 03A.07A - Cross Slope (PAR) Cross slope of the pedestrian access route exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 2005 PROWA G- R301.4. 1 14.1% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 41 Verde Ridge/El Rodeo NE Corner 03A.07A - Cross Slope (PAR) Cross slope of the pedestrian access route exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 2005 PROWA G- R301.4. 1 6.8% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 44 Locklenna Ln./Seaspray Dr. SW Corner 03A.07A - Cross Slope (PAR) Cross slope of the pedestrian access route exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 2005 PROWA G- R301.4. 1 6.4% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 50 Hawthorne Blvd./Dupree Dr. NE Corner Page 20 of 21 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # Curb RampsReporting: 118 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03A - Public Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03A.07A - Cross Slope (PAR) Cross slope of the pedestrian access route exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 2005 PROWA G- R301.4. 1 12.1% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 56 Hawthorne Blvd./Vallon Dr. NW Corner 03A.08 - Running Slope (PAR) Slope of the pedestrian access route exceeds 1:20. Or slope of the pedestrian access route contained within a street or highway border exceeds the grade of the adjacent roadway. (1:20 requirement does not apply to compliant ramps or where slope of the pedestrian access route contained within a street or highway border does not exceed the grade of the adjacent roadway.) 4.3.7 403.3 1133B.7 .3 2005 PROWA G- R301.4. 2 8.9% RS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 57 Hawthorne Blvd./Vallon Dr. NW Corner 03A.07A - Cross Slope (PAR) Cross slope of the pedestrian access route exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 2005 PROWA G- R301.4. 1 13.7% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 62 Hawthorne Blvd./Vallon Dr. SW Corner 03A.07A - Cross Slope (PAR) Cross slope of the pedestrian access route exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 2005 PROWA G- R301.4. 1 8% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 65 Hawthorne Blvd./Vallon Dr. SE Corner 21Number of Key Notes for Group 03A - Public Path of Travel: 118Number of Key Notes for Facility Curb Ramps: 118Total Number of Key Notes for All Groups: Page 21 of 21 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA