Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
City Hall Grounds part 3 page 1-38_ComplianceReport_20130509-112951
Facility ID # 02A - City Hall GroundsReporting: 173 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 05 - Drinking Fountains Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 05.16 - Other - Drinking Fountains See Additional Comments ----Non compliant DF & no WC approach. PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 141 Walkway from Comm. Dev. Bldg. to Ch 33 Bldg. 1Number of Key Notes for Group 05 - Drinking Fountains: Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab.404 .2.4.1; Fig.404. 2.4.1 1133B.2 .4.2; Fig. 11B-26 -CP - Client/Patient Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 15 SE. of Admin. Bldg. Page 1 of 38 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02A - City Hall GroundsReporting: 173 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab.404 .2.4.1; Fig.404. 2.4.1 1133B.2 .4.2; Fig. 11B-26 -48" deep landing on pull side EC - Employee Common Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 54 N. of Comm. Dev. Bldg. 10.07A - Landing - Level and Clear Floor is not level (slope is greater than 2% in some or all directions). OR Floor is not clear within the required maneuvering space. 4.13.6; Fig. 25 305; 404.2.4. 4 1133B.2 .4 -3.3%PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 57 N. of Comm. Dev. Bldg. 10.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab.404 .2.4.1; Fig.404. 2.4.1 1133B.2 .4.2; Fig. 11B-26 -23" clear at strike side.EC - Employee Common Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 59 S. of Comm. Dev. Bldg. 10.07A - Landing - Level and Clear Floor is not level (slope is greater than 2% in some or all directions). OR Floor is not clear within the required maneuvering space. 4.13.6; Fig. 25 305; 404.2.4. 4 1133B.2 .4 -3.2%EC - Employee Common Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 60 S. of Comm. Dev. Bldg. Page 2 of 38 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02A - City Hall GroundsReporting: 173 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab.404 .2.4.1; Fig.404. 2.4.1 1133B.2 .4.2; Fig. 11B-26 -6" strike clearance PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 68 S. of PV Net Bldg. 10.02 - Entrance Sign Accessible entrance is not identified by an ISA.28 CFR 35.163( b)1 216.6 1117B.5 .8.1.2 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 150 Tennis Entrance 10.07A - Landing - Level and Clear Floor is not level (slope is greater than 2% in some or all directions). OR Floor is not clear within the required maneuvering space. 4.13.6; Fig. 25 305; 404.2.4. 4 1133B.2 .4 -8.2% & no strike clearance.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 151 Tennis Entrance 10.08 - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 152 Tennis Entrance 10.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -Door scrapes.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 153 Tennis Entrance Page 3 of 38 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02A - City Hall GroundsReporting: 173 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10Number of Key Notes for Group 10 - Entrances and Exits: Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -3.4% & 4.7%PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 13 SE. of Admin. Bldg. 03B.13 - > 1/2" Changes in Level Curb ramps, ramps, or elevators are not used for changes in level greater than 1/2 inch. (Lifts may only be used in certain limited situations.) 4.5.2 303.4 1124B.2 -5" high step CP - Client/Patient Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 14 SE. of Admin. Bldg. 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -6.0%, 5.5% & 3.4% at turning point. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 16 SE. of Admin. Bldg. 03B.11 - Ramps This portion of an accessible route with a slope greater than 5% does not comply with the requirements for compliant ramps. 4.8.1 405 1133B.5 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 17 SE. of Admin. Bldg. 03B.04 - Width Accessible route of travel is less than 48” wide (note: 48" wide requirement does not apply to doorways or gates). 4.3.3 403.5.1 1133B.7 .1 -47" wide PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 18 W. of Admin. Bldg. 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -3.2%PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 19 W. of Admin. Bldg. Page 4 of 38 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02A - City Hall GroundsReporting: 173 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.21 - Hazardous Vehicular Areas - Detectable Warnings Where a walk crosses or adjoins the vehicular way and the walking surface is not separated by curbs, railings, or other elements between the pedestrian areas and vehicular areas, the boundary between the areas is not defined by a continuous detectable warning at least 36” wide complying with CBC 1121B.3.1 item 8(a). (i.e., the warning surface shall contrast visually with adjoining surfaces, either light on dark or dark on light, and shall differ from adjoining walking surfaces in resiliency or sound on cane contact. Color: yellow conforming to Federal Color No. 33538, Table IV/ Standard No. 595B. Where the color value contrast between the yellow warning and the main walking surface is less than 70 percent, a 1" wide black strip shall separate the yellow warning from the main walking surface.) 4.29.5 705.1 1133B.8 .5 -PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 20 W. of Admin. Bldg. 03B.11 - Ramps This portion of an accessible route with a slope greater than 5% does not comply with the requirements for compliant ramps. 4.8.1 405 1133B.5 -9.5%MS - Maintenance and Storage Only C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 22 W. of Admin. Bldg. 03B.13 - > 1/2" Changes in Level Curb ramps, ramps, or elevators are not used for changes in level greater than 1/2 inch. (Lifts may only be used in certain limited situations.) 4.5.2 303.4 1124B.2 -MS - Maintenance and Storage Only C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 23 W. of Admin. Bldg. Page 5 of 38 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02A - City Hall GroundsReporting: 173 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.21 - Hazardous Vehicular Areas - Detectable Warnings Where a walk crosses or adjoins the vehicular way and the walking surface is not separated by curbs, railings, or other elements between the pedestrian areas and vehicular areas, the boundary between the areas is not defined by a continuous detectable warning at least 36” wide complying with CBC 1121B.3.1 item 8(a). (i.e., the warning surface shall contrast visually with adjoining surfaces, either light on dark or dark on light, and shall differ from adjoining walking surfaces in resiliency or sound on cane contact. Color: yellow conforming to Federal Color No. 33538, Table IV/ Standard No. 595B. Where the color value contrast between the yellow warning and the main walking surface is less than 70 percent, a 1" wide black strip shall separate the yellow warning from the main walking surface.) 4.29.5 705.1 1133B.8 .5 -PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 24 W. of Admin. Bldg. 03B.22 - Other - On-Site Accessible Path of Travel See Additional Comments ----MS - Maintenance and Storage Only C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 25 W. of Admin. Bldg. 03B.12 - > 1/4" Changes in Level Where walkway levels change abruptly, the vertical difference between them exceeds 1/4 inch. Or changes in level between 1/4 inch and 1/2 inch are beveled with a slope greater than 1:2. 4.5.2 303.2; 303.3 1124B.2 -3/4" gap PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 26 N. of Comm. Dev. Bldg. 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -4.6% & 4.4 at mail box PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 28 E. of Admin. Bldg. Page 6 of 38 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02A - City Hall GroundsReporting: 173 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.21 - Hazardous Vehicular Areas - Detectable Warnings Where a walk crosses or adjoins the vehicular way and the walking surface is not separated by curbs, railings, or other elements between the pedestrian areas and vehicular areas, the boundary between the areas is not defined by a continuous detectable warning at least 36” wide complying with CBC 1121B.3.1 item 8(a). (i.e., the warning surface shall contrast visually with adjoining surfaces, either light on dark or dark on light, and shall differ from adjoining walking surfaces in resiliency or sound on cane contact. Color: yellow conforming to Federal Color No. 33538, Table IV/ Standard No. 595B. Where the color value contrast between the yellow warning and the main walking surface is less than 70 percent, a 1" wide black strip shall separate the yellow warning from the main walking surface.) 4.29.5 705.1 1133B.8 .5 -No detectable warning between parking & walkway PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 35 E. of Admin. Bldg. 03B.22 - Other - On-Site Accessible Path of Travel See Additional Comments ----35" wide detectable warnings PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 36 E. of Admin. Bldg. 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -3.3%PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 42 NW. PV Net Bldg. 03B.13 - > 1/2" Changes in Level Curb ramps, ramps, or elevators are not used for changes in level greater than 1/2 inch. (Lifts may only be used in certain limited situations.) 4.5.2 303.4 1124B.2 -5 1/4" to 8" Steps.EW - Employee Work Area C - Partial Barrier to Access 6 - Employee- Only Work Areas (1994 ADAS 4.1.1(3)) 43 W. PV Net Bldg. 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.8% to 3.1%PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 48 W. PV Net Bldg. Page 7 of 38 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02A - City Hall GroundsReporting: 173 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.21 - Hazardous Vehicular Areas - Detectable Warnings Where a walk crosses or adjoins the vehicular way and the walking surface is not separated by curbs, railings, or other elements between the pedestrian areas and vehicular areas, the boundary between the areas is not defined by a continuous detectable warning at least 36” wide complying with CBC 1121B.3.1 item 8(a). (i.e., the warning surface shall contrast visually with adjoining surfaces, either light on dark or dark on light, and shall differ from adjoining walking surfaces in resiliency or sound on cane contact. Color: yellow conforming to Federal Color No. 33538, Table IV/ Standard No. 595B. Where the color value contrast between the yellow warning and the main walking surface is less than 70 percent, a 1" wide black strip shall separate the yellow warning from the main walking surface.) 4.29.5 705.1 1133B.8 .5 -No detectable warning between walkway & vehicular area at flush transition. PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 49 SW. PV Net Bldg. 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.5%PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 50 N. of Comm. Dev. Bldg. 03B.13 - > 1/2" Changes in Level Curb ramps, ramps, or elevators are not used for changes in level greater than 1/2 inch. (Lifts may only be used in certain limited situations.) 4.5.2 303.4 1124B.2 -1 3/8" high between door & landing. EC - Employee Common Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 51 N. of Comm. Dev. Bldg. 03B.22 - Other - On-Site Accessible Path of Travel See Additional Comments ----No compliant access to bench. Bench not accessible EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 55 N. of Comm. Dev. Bldg. Page 8 of 38 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02A - City Hall GroundsReporting: 173 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.1%, 3.3%, 3.5% at transition points. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 56 N. of Comm. Dev. Bldg. 03B.13 - > 1/2" Changes in Level Curb ramps, ramps, or elevators are not used for changes in level greater than 1/2 inch. (Lifts may only be used in certain limited situations.) 4.5.2 303.4 1124B.2 -1 3/4" high.EC - Employee Common Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 58 S. of Comm. Dev. Bldg. 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -3.9%PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 61 SE. of Comm. Dev. Bldg. 03B.22 - Other - On-Site Accessible Path of Travel See Additional Comments ----35" wide domes in lieu of 36" wide. PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 62 SE. of Comm. Dev. Bldg. 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -1.9%, 2.6%, & 2.7%PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 63 SE. of Comm. Dev. Bldg. 03B.10 - Running Slope Slope of the accessible route of travel exceeds 1:20. 4.3.7 403.3 1133B.7 .3 -6.5% RS & no handrails provided. PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 64 SE. of Comm. Dev. Bldg. Page 9 of 38 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02A - City Hall GroundsReporting: 173 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.21 - Hazardous Vehicular Areas - Detectable Warnings Where a walk crosses or adjoins the vehicular way and the walking surface is not separated by curbs, railings, or other elements between the pedestrian areas and vehicular areas, the boundary between the areas is not defined by a continuous detectable warning at least 36” wide complying with CBC 1121B.3.1 item 8(a). (i.e., the warning surface shall contrast visually with adjoining surfaces, either light on dark or dark on light, and shall differ from adjoining walking surfaces in resiliency or sound on cane contact. Color: yellow conforming to Federal Color No. 33538, Table IV/ Standard No. 595B. Where the color value contrast between the yellow warning and the main walking surface is less than 70 percent, a 1" wide black strip shall separate the yellow warning from the main walking surface.) 4.29.5 705.1 1133B.8 .5 -PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 65 SE. of Comm. Dev. Bldg. 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.7%PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 66 SE. of PV Net Bldg. Page 10 of 38 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02A - City Hall GroundsReporting: 173 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.21 - Hazardous Vehicular Areas - Detectable Warnings Where a walk crosses or adjoins the vehicular way and the walking surface is not separated by curbs, railings, or other elements between the pedestrian areas and vehicular areas, the boundary between the areas is not defined by a continuous detectable warning at least 36” wide complying with CBC 1121B.3.1 item 8(a). (i.e., the warning surface shall contrast visually with adjoining surfaces, either light on dark or dark on light, and shall differ from adjoining walking surfaces in resiliency or sound on cane contact. Color: yellow conforming to Federal Color No. 33538, Table IV/ Standard No. 595B. Where the color value contrast between the yellow warning and the main walking surface is less than 70 percent, a 1" wide black strip shall separate the yellow warning from the main walking surface.) 4.29.5 705.1 1133B.8 .5 -PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 67 SE. of PV Net Bldg. 03B.10 - Running Slope Slope of the accessible route of travel exceeds 1:20. 4.3.7 403.3 1133B.7 .3 -13.2%PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 69 S. of PV Net Bldg. 03B.11 - Ramps This portion of an accessible route with a slope greater than 5% does not comply with the requirements for compliant ramps. 4.8.1 405 1133B.5 -No handrails or wheel guide provided. PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 70 S. of PV Net Bldg. Page 11 of 38 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02A - City Hall GroundsReporting: 173 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.21 - Hazardous Vehicular Areas - Detectable Warnings Where a walk crosses or adjoins the vehicular way and the walking surface is not separated by curbs, railings, or other elements between the pedestrian areas and vehicular areas, the boundary between the areas is not defined by a continuous detectable warning at least 36” wide complying with CBC 1121B.3.1 item 8(a). (i.e., the warning surface shall contrast visually with adjoining surfaces, either light on dark or dark on light, and shall differ from adjoining walking surfaces in resiliency or sound on cane contact. Color: yellow conforming to Federal Color No. 33538, Table IV/ Standard No. 595B. Where the color value contrast between the yellow warning and the main walking surface is less than 70 percent, a 1" wide black strip shall separate the yellow warning from the main walking surface.) 4.29.5 705.1 1133B.8 .5 -PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 71 S. of PV Net Bldg. 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -3.1%PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 72 SW. of PV Net Bldg. 03B.10 - Running Slope Slope of the accessible route of travel exceeds 1:20. 4.3.7 403.3 1133B.7 .3 -5.8%PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 73 SW. of PV Net Bldg. 03B.12 - > 1/4" Changes in Level Where walkway levels change abruptly, the vertical difference between them exceeds 1/4 inch. Or changes in level between 1/4 inch and 1/2 inch are beveled with a slope greater than 1:2. 4.5.2 303.2; 303.3 1124B.2 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 74 SW. of PV Net Bldg. Page 12 of 38 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02A - City Hall GroundsReporting: 173 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.8 CS PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 75 N. of PV Net Bldg. 03B.21 - Hazardous Vehicular Areas - Detectable Warnings Where a walk crosses or adjoins the vehicular way and the walking surface is not separated by curbs, railings, or other elements between the pedestrian areas and vehicular areas, the boundary between the areas is not defined by a continuous detectable warning at least 36” wide complying with CBC 1121B.3.1 item 8(a). (i.e., the warning surface shall contrast visually with adjoining surfaces, either light on dark or dark on light, and shall differ from adjoining walking surfaces in resiliency or sound on cane contact. Color: yellow conforming to Federal Color No. 33538, Table IV/ Standard No. 595B. Where the color value contrast between the yellow warning and the main walking surface is less than 70 percent, a 1" wide black strip shall separate the yellow warning from the main walking surface.) 4.29.5 705.1 1133B.8 .5 -0" transition between walkway & Parking. PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 76 N. of PV Net Bldg. 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -8.2%PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 77 NE. of PV Net Bldg. 03B.10 - Running Slope Slope of the accessible route of travel exceeds 1:20. 4.3.7 403.3 1133B.7 .3 -10.8%PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 78 NE. of PV Net Bldg. Page 13 of 38 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02A - City Hall GroundsReporting: 173 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.21 - Hazardous Vehicular Areas - Detectable Warnings Where a walk crosses or adjoins the vehicular way and the walking surface is not separated by curbs, railings, or other elements between the pedestrian areas and vehicular areas, the boundary between the areas is not defined by a continuous detectable warning at least 36” wide complying with CBC 1121B.3.1 item 8(a). (i.e., the warning surface shall contrast visually with adjoining surfaces, either light on dark or dark on light, and shall differ from adjoining walking surfaces in resiliency or sound on cane contact. Color: yellow conforming to Federal Color No. 33538, Table IV/ Standard No. 595B. Where the color value contrast between the yellow warning and the main walking surface is less than 70 percent, a 1" wide black strip shall separate the yellow warning from the main walking surface.) 4.29.5 705.1 1133B.8 .5 -PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 99 N. of Tennis Court 03B.22 - Other - On-Site Accessible Path of Travel See Additional Comments ----60" high Doggy Bags.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 100 N. of Tennis Court 03B.13 - > 1/2" Changes in Level Curb ramps, ramps, or elevators are not used for changes in level greater than 1/2 inch. (Lifts may only be used in certain limited situations.) 4.5.2 303.4 1124B.2 -3/4" high PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 103 Picnic Area S. of PV Net Bldg. 03B.08 - Free Standing Protruding Objects Free standing object(s) mounted on posts with leading edges between 27" and 80” high (such as a sign or telephone) projects more than 12” into the perpendicular route of travel. (Protruding object(s) shall not reduce required clear width of an accessible route.) 4.4.1 307.3 1133B.8 .6.1 -BBQ protrudes > than 4" at 32" high. PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 105 Picnic Area S. of PV Net Bldg. Page 14 of 38 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02A - City Hall GroundsReporting: 173 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.01 - On- site Accessible Route of Travel There is no accessible route within the property line of the site linking an accessible building entrance with site arrival points serving the following, if provided: public transportation stops, accessible parking, passenger loading zones, and public sidewalks. 4.1.2(1) 202.2.1; Advisory 206.2.1 1114B.1 .2; 1127B.1 -20.9% CS & 6.2% RS at grass area. PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 107 Bus Stop to On-site-path of travel 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -3.0%PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 108 W. of PV Net Bldg. 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -7.1% near edge of walkway PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 119 Stairs at PV Net NX Bldg. 03B.13 - > 1/2" Changes in Level Curb ramps, ramps, or elevators are not used for changes in level greater than 1/2 inch. (Lifts may only be used in certain limited situations.) 4.5.2 303.4 1124B.2 -1 1/2" high.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 126 Ramp PV Net NX Bldg. 03B.04 - Width Accessible route of travel is less than 48” wide (note: 48" wide requirement does not apply to doorways or gates). 4.3.3 403.5.1 1133B.7 .1 -40" wide PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 137 Walkway to trail E. of PV Net NX Bldg. 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.2%, 3.9%PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 138 Walkway to trail E. of PV Net NX Bldg. 03B.10 - Running Slope Slope of the accessible route of travel exceeds 1:20. 4.3.7 403.3 1133B.7 .3 -6.6%, 7.0%PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 139 Walkway to trail E. of PV Net NX Bldg. Page 15 of 38 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02A - City Hall GroundsReporting: 173 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.15 - Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Cracks PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 140 Walkway to trail E. of PV Net NX Bldg. 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -3.1% at landing.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 142 Walkway from Comm. Dev. Bldg. to Ch 33 Bldg. 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.8%, 3.3%, 2.9%...PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 143 Walkway from Comm. Dev. Bldg. to Ch 33 Bldg. 03B.15 - Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Cracks PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 144 Walkway from Comm. Dev. Bldg. to Ch 33 Bldg. 03B.21 - Hazardous Vehicular Areas - Detectable Warnings Where a walk crosses or adjoins the vehicular way and the walking surface is not separated by curbs, railings, or other elements between the pedestrian areas and vehicular areas, the boundary between the areas is not defined by a continuous detectable warning at least 36” wide complying with CBC 1121B.3.1 item 8(a). (i.e., the warning surface shall contrast visually with adjoining surfaces, either light on dark or dark on light, and shall differ from adjoining walking surfaces in resiliency or sound on cane contact. Color: yellow conforming to Federal Color No. 33538, Table IV/ Standard No. 595B. Where the color value contrast between the yellow warning and the main walking surface is less than 70 percent, a 1" wide black strip shall separate the yellow warning from the main walking surface.) 4.29.5 705.1 1133B.8 .5 -PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 145 Walkway from Comm. Dev. Bldg. to Ch 33 Bldg. Page 16 of 38 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02A - City Hall GroundsReporting: 173 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.15 - Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Cracks & loose surface PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 146 Tennis Walkway 03B.21 - Hazardous Vehicular Areas - Detectable Warnings Where a walk crosses or adjoins the vehicular way and the walking surface is not separated by curbs, railings, or other elements between the pedestrian areas and vehicular areas, the boundary between the areas is not defined by a continuous detectable warning at least 36” wide complying with CBC 1121B.3.1 item 8(a). (i.e., the warning surface shall contrast visually with adjoining surfaces, either light on dark or dark on light, and shall differ from adjoining walking surfaces in resiliency or sound on cane contact. Color: yellow conforming to Federal Color No. 33538, Table IV/ Standard No. 595B. Where the color value contrast between the yellow warning and the main walking surface is less than 70 percent, a 1" wide black strip shall separate the yellow warning from the main walking surface.) 4.29.5 705.1 1133B.8 .5 -PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 147 Tennis Walkway 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -3.3%, 3.9%, & 4.7%PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 148 Tennis Walkway 03B.12 - > 1/4" Changes in Level Where walkway levels change abruptly, the vertical difference between them exceeds 1/4 inch. Or changes in level between 1/4 inch and 1/2 inch are beveled with a slope greater than 1:2. 4.5.2 303.2; 303.3 1124B.2 -1/4" high PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 149 Tennis Entrance Page 17 of 38 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02A - City Hall GroundsReporting: 173 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.05A - Passing Spaces Where the accessible route of travel is less than 60” wide, passing spaces at least 60” by 60” or intersecting walks, allowing passing at reasonable intervals not exceeding 200’, are not provided. 4.3.4 403.5.3 1133B.7 .1 -30" wide walkway PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 161 N. of Ch 33 Bldg. Picnic Area 03B.10 - Running Slope Slope of the accessible route of travel exceeds 1:20. 4.3.7 403.3 1133B.7 .3 -7.6%PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 162 N. of Ch 33 Bldg. Picnic Area 03B.22 - Other - On-Site Accessible Path of Travel See Additional Comments ----No compliant path of travel to BBQ & Picnic Table PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 163 N. of Ch 33 Bldg. Picnic Area 03B.21 - Hazardous Vehicular Areas - Detectable Warnings Where a walk crosses or adjoins the vehicular way and the walking surface is not separated by curbs, railings, or other elements between the pedestrian areas and vehicular areas, the boundary between the areas is not defined by a continuous detectable warning at least 36” wide complying with CBC 1121B.3.1 item 8(a). (i.e., the warning surface shall contrast visually with adjoining surfaces, either light on dark or dark on light, and shall differ from adjoining walking surfaces in resiliency or sound on cane contact. Color: yellow conforming to Federal Color No. 33538, Table IV/ Standard No. 595B. Where the color value contrast between the yellow warning and the main walking surface is less than 70 percent, a 1" wide black strip shall separate the yellow warning from the main walking surface.) 4.29.5 705.1 1133B.8 .5 -PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 165 N. of Ch 33 Bldg. Picnic Area Page 18 of 38 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02A - City Hall GroundsReporting: 173 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.10 - Running Slope Slope of the accessible route of travel exceeds 1:20. 4.3.7 403.3 1133B.7 .3 -6.1%PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 171 N. Walkway at Ch 33 Bldg. 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.7% & 11.4 from accessible bldg. entrances. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 172 N. Walkway at Ch 33 Bldg. 03B.10 - Running Slope Slope of the accessible route of travel exceeds 1:20. 4.3.7 403.3 1133B.7 .3 -5.9%, 5.2%, 5.9%PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 173 N. of Comm. Dev. Bldg. 68Number of Key Notes for Group 03B - On-Site Path of Travel: Group 01 - Parking Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 01.02 - Number - Accessible Parking Spaces Where parking spaces are provided for self- parking by employees or visitors or both, the required number of accessible parking spaces is not provided. (Note: All or some of the accessible parking spaces may be in a different location if equivalent or greater accessibility is ensured.) (Spaces required: (1 to 25 // 1) (26 to 50 // 2) (51 to 75 // 3) (76 to 100 // 4) (101 to 150 // 5) (151 to 200 // 6) (201 to 300 // 7) (301 to 400 // 8) (401 to 500 // 9) (501 to 1,000 // *) (1,000 and over // **) (*Two percent of total.) (**Twenty plus one for each 100, or fraction over 1,001.) 4.1.2(5) 208.3.1( 2) 1129B.1 ; 1129B.2 ; Table 11B-6 Authorized vehicles only parking lot. PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 21 W. of Admin. Bldg. Page 19 of 38 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02A - City Hall GroundsReporting: 173 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 01 - Parking Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 01.09 - Stall Dimensions Accessible parking spaces, including van spaces, are not at least 9’ wide and 18’ long with a demarcated access aisle. (Two spaces may share a common aisle; parking space width is measured from the center line of the stripe on one side to the center line of the stripe on the other.) 4.6.3 502.2 1129B.3 items 1 & 2 16'-5" long stall.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 29 E. of Admin. Bldg. 01.11 - Car Access Aisle - Dimensions Car access aisle is not at least 5’ wide and 18’ long. (Aisle width is measured from the center line of the stripe on one side to the center line of the stripe on the other.) 4.1.2(5) (a) 502.3.1 1129B.3 item 1 4'-8" wide x 16'-8" long PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 30 E. of Admin. Bldg. 01.13 - Level Surface The accessible parking spaces and access aisles are not level (slope is greater than 2%). 4.6.3 502.4; advisory 502.4 1129B.3 items 3 & 4 3.3%, 1.9%, & 3.8%PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 31 E. of Admin. Bldg. 01.15C - Minimum Fine Sign Accessible parking space has no sign stating "Minimum Fine $250" below the ISA. --1129B.4 PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 32 E. of Admin. Bldg. 01.18 - Pavement Sign A 36” square ISA is not painted on the pavement at the rear of the stall. -502.6 1129B.4 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 33 E. of Admin. Bldg. 01.19C - Tow- away Sign - Contact Information California tow-away sign does not include contact information. --1129B.4 PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 34 E. of Admin. Bldg. Page 20 of 38 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02A - City Hall GroundsReporting: 173 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 01 - Parking Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 01.13 - Level Surface The accessible parking spaces and access aisles are not level (slope is greater than 2%). 4.6.3 502.4; advisory 502.4 1129B.3 items 3 & 4 2.6% to 7.2%PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 37 N. PV Net Bldg. 01.15C - Minimum Fine Sign Accessible parking space has no sign stating "Minimum Fine $250" below the ISA. --1129B.4 PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 38 N. PV Net Bldg. 01.17 - Van Accessible Sign Van accessible space has no sign stating "Van Accessible" below the ISA. 4.6.4 502.6 1129B.4 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 39 N. PV Net Bldg. 01.18 - Pavement Sign A 36” square ISA is not painted on the pavement at the rear of the stall. -502.6 1129B.4 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 40 N. PV Net Bldg. 01.19C - Tow- away Sign - Contact Information California tow-away sign does not include contact information. --1129B.4 PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 41 N. PV Net Bldg. 01.10A - Van Access Aisle - Dimensions Where the parking space is designated as "van accessible," the adjacent access aisle is not at least 8’ wide by 18’ long. (Aisle width is measured from the center line of the stripe on one side to the center line of the stripe on the other.) 4.1.2(5) (b) -1129B.3 item 2 7'-8" wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 120 Parking PV Net NX Bldg. Page 21 of 38 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02A - City Hall GroundsReporting: 173 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 01 - Parking Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 01.13 - Level Surface The accessible parking spaces and access aisles are not level (slope is greater than 2%). 4.6.3 502.4; advisory 502.4 1129B.3 items 3 & 4 2.7% & 3.3%PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 121 Parking PV Net NX Bldg. 01.14 - Surface Access aisle is not stable, firm, and slip resistant. 4.5.1 302 1124B.1 Cracks & deterioration.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 122 Parking PV Net NX Bldg. 01.15C - Minimum Fine Sign Accessible parking space has no sign stating "Minimum Fine $250" below the ISA. --1129B.4 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 123 Parking PV Net NX Bldg. 01.18 - Pavement Sign A 36” square ISA is not painted on the pavement at the rear of the stall. -502.6 1129B.4 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 124 Parking PV Net NX Bldg. 01.19B - Tow- away Sign A California tow-away sign is not posted in a conspicuous place at each entrance to off–street parking lot, or immediately adjacent to and visible from each accessible stall. --1129B.4 PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 125 Parking PV Net NX Bldg. Page 22 of 38 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02A - City Hall GroundsReporting: 173 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 01 - Parking Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 01.02 - Number - Accessible Parking Spaces Where parking spaces are provided for self- parking by employees or visitors or both, the required number of accessible parking spaces is not provided. (Note: All or some of the accessible parking spaces may be in a different location if equivalent or greater accessibility is ensured.) (Spaces required: (1 to 25 // 1) (26 to 50 // 2) (51 to 75 // 3) (76 to 100 // 4) (101 to 150 // 5) (151 to 200 // 6) (201 to 300 // 7) (301 to 400 // 8) (401 to 500 // 9) (501 to 1,000 // *) (1,000 and over // **) (*Two percent of total.) (**Twenty plus one for each 100, or fraction over 1,001.) 4.1.2(5) 208.3.1( 2) 1129B.1 ; 1129B.2 ; Table 11B-6 No accessible parking at reserved area. CP - Client/Patient Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 136 Parking S. of Comm. Dev. Bldg. 01.10A - Van Access Aisle - Dimensions Where the parking space is designated as "van accessible," the adjacent access aisle is not at least 8’ wide by 18’ long. (Aisle width is measured from the center line of the stripe on one side to the center line of the stripe on the other.) 4.1.2(5) (b) -1129B.3 item 2 7'-7" wide PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 166 Parking at Ch 33 Bldg. 01.15C - Minimum Fine Sign Accessible parking space has no sign stating "Minimum Fine $250" below the ISA. --1129B.4 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 167 Parking at Ch 33 Bldg. 01.18 - Pavement Sign A 36” square ISA is not painted on the pavement at the rear of the stall. -502.6 1129B.4 48" x 48"PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 168 Parking at Ch 33 Bldg. 01.19A - Lettering The words “NO PARKING” is not provided in each access aisle, painted in white, 12” high letters. --1129B.3 items 1 & 2 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 169 Parking at Ch 33 Bldg. Page 23 of 38 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02A - City Hall GroundsReporting: 173 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 01 - Parking Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 01.19B - Tow- away Sign A California tow-away sign is not posted in a conspicuous place at each entrance to off–street parking lot, or immediately adjacent to and visible from each accessible stall. --1129B.4 PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 170 Parking at Ch 33 Bldg. 24Number of Key Notes for Group 01 - Parking: Group 30 - Parks Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 30.08 - Maintenance of Accessible Trail - Title II Entity Accessible trail is not in operable working condition. (28 CFR 35.133) --1101B.3 28 CFR 35.133 Landscape on trail.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 1 South Spur Trail 30.10C - Trail Segment - Cross Slope Cross slope of the trail segment exceeds 1:20.---1999 ADAAG- 16.2.7.1 22.5%, 13.5%, 14.2%, & 24.4% PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 2 South Spur Trail 30.10E - Trail Surface The surface of the trail is not firm or stable.---1999 ADAAG- 16.2.1 Loose dirt & landscape.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 3 South Spur Trail 30.08 - Maintenance of Accessible Trail - Title II Entity Accessible trail is not in operable working condition. (28 CFR 35.133) --1101B.3 28 CFR 35.133 Landscape on trail.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 4 Alta Vicente Trail Page 24 of 38 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02A - City Hall GroundsReporting: 173 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 30 - Parks Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 30.10A - Trail Segment - Running Slope Running slope of trail segment in the direction of travel does not comply with the following: a. 5% or less for any distance. b. From 5.1% to 8.33% for 200' maximum. c. From 8.34% to 10% for 30' maximum. d. From 10% to 12% for 10' maximum. ---1999 ADAAG- 16.2.7.2 .1; 16.2.7.2 .2; 16.2.7.2 .3; 16.2.7.2 .4 20%, 29.8%, 22%, 21%, 20.9%, 7.4%, 8.3%, 2.3%... PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 5 Alta Vicente Trail 30.10B - Trail Resting Space Resting space does not comply with 1999 ADAAG Section 16.2.8 (Resting intervals shall be 60" min. in length, shall have a width at least as wide as the trail and have a slope of 5% or less in any direction. The installation of resting spaces is required as follows: Percent slope, maximum length, Rest interval: 0% to 5.0%, No restriction, No restriction; 5.1% to 8.33%, 200', Every 200'; 8.34% to 10%, 30', Every 30'; 10.1% to 12%, 10', Every 10'.) ---1999 ADAAG- 16.2.7.2 ; 16.2.8 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 6 Alta Vicente Trail 30.10C - Trail Segment - Cross Slope Cross slope of the trail segment exceeds 1:20.---1999 ADAAG- 16.2.7.1 12.4%, 5.3%, 20.9%, 11.5%, 16.8%... PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 7 Alta Vicente Trail 30.10D - Clear Tread Width of Trail The clear tread width of the trail is not 36" min., except the width may be reduced to 32" where existing conditions cannot be mitigated. ---1999 ADAAG- 16.2.2 30" clear varies.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 8 Alta Vicente Trail 30.10E - Trail Surface The surface of the trail is not firm or stable.---1999 ADAAG- 16.2.1 Loose dirt & landscape.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 9 Alta Vicente Trail Page 25 of 38 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02A - City Hall GroundsReporting: 173 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 30 - Parks Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 30.11F - Trails - Passing Space Where the width of the trail is less than 60", passing spaces measuring 60" x 60" are not provided at intervals of 1000' maximum. ---1999 ADAAG- 16.2.6 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 10 Alta Vicente Trail 30.11H - Trails - Signs Trail complying with 1999 ADAAG Section 16.2 is not designated with a symbol at the trailhead and at designated access points. OR Signage has been provided but does not indicate the total distance of the accessible segment and the location of the first point of departure from the Section 16.2 requirements. ---1999 ADAAG- 16.2.10 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 11 Alta Vicente Trail 30.30 - Number - Picnic Table Wheelchair Seating Spaces Picnic table does not provide at least one wheelchair seating space. OR Where the table top perimeter exceeds 24 linear feet, the number of wheelchair seating spaces provided does not comply with the following: (Table Top Perimeter // Wheelchair Spaces) (25 LF – 44 LF // 2 spaces) (45 LF – 64 LF // 3 spaces) (65 LF – 84 LF // 4 spaces) (85 LF – 104 LF // 5 spaces) ---1999 ADAAG- 16.5.3 PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 104 Picnic Area S. of PV Net Bldg. 30.34C - Picnic Table - Knee Space Depth Picnic table does not provide at least 19" depth for accessible knee clearance. 4.32.3 305; 306 1122B.3 1999 ADAAG- 16.5.4 17" deep PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 106 Picnic Area S. of PV Net Bldg. 30.34C - Picnic Table - Knee Space Depth Picnic table does not provide at least 19" depth for accessible knee clearance. 4.32.3 305; 306 1122B.3 1999 ADAAG- 16.5.4 PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 164 N. of Ch 33 Bldg. Picnic Area 14Number of Key Notes for Group 30 - Parks: Group 02 - Passenger Loading Zone Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation Page 26 of 38 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02A - City Hall GroundsReporting: 173 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 02 - Passenger Loading Zone Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 02.11A - Bus Stop Pad Size Bus stop pad does not measure 8’ long (measured from the curb or vehicle roadway edge) by 5’ wide (measured parallel to the vehicle roadway). 10.2.1 810.2.2 1121B.1 2'-0" x 24'-9"PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 109 Bus Stop 02.11B - Bus Stop Pad and Accessible Route Bus stop pad is not connected to an accessible route. 10.2.1 810.2.3 1121B.1 No compliant POT to On Site POT. PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 110 Bus Stop 02.12A - Bus Stop Pad Slope Parallel to Roadway Bus stop pad is not at the same slope as the roadway in the direction parallel to the roadway. 10.2.1 810.2.4 1121B.2 .1 4.5% sidewalk & 5.1% road.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 111 Bus Stop 02.12B - Bus Stop Pad Slope Perpendicular to Roadway Bus stop pad slope perpendicular to the roadway exceeds 2%. 10.2.1 810.2.4 1121B.2 .1 4.5%PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 112 Bus Stop 4Number of Key Notes for Group 02 - Passenger Loading Zone: Group 03A - Public Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03A.15 - Other - Pedestrian Accessible Route (Public Right of Way) See Additional Comments ----No compliant access to Trail Park. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 12 Alta Vicente Trail 1Number of Key Notes for Group 03A - Public Path of Travel: Page 27 of 38 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02A - City Hall GroundsReporting: 173 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 07 - Ramps Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 07.02 - Running Slope Slope of the ramp exceeds 8.33% (or the least possible compliant slope). 4.8.2 405.2; Advisory 405.2 1133B.5 .3 -6.9% & 8.7% from parking to switchback landing PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 127 Ramp PV Net NX Bldg. 07.05 - Surface The ramp surface is not stable, firm and slip- resistant. 4.8.6; 4.5 302.1; Advisory 302.1 1124B.1 -8 floor mats PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 128 Ramp PV Net NX Bldg. 07.06 - Clear Width Clear width of the ramp is less than 48“ (handrails may project into the required width a distance of 4-1/2” max.. from each side). 4.8.3 405.5 1133B.5 .2 -46 1/4" between wall & guiderail.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 129 Ramp PV Net NX Bldg. 07.11A - Intermediate Landing - Change of Direction Where there is an intermediate landing, and the ramp changes direction (>30-degree), the landing is less than 72” x 60“. 4.8.4(3) 405.7.4 1133B.5 .4.6 -74" x 70"PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 130 Ramp PV Net NX Bldg. 07.16 - Handrails Slope of the ramp exceeds 5%, and handrails are not provided on each side. (Per CBC 1133B.5.5.1, at exterior door landings, handrails are not required on ramps less than 6” high or 72” long. Handrails are not required on curb ramps or adjacent to fixed seating in assembly areas.) 4.8.5 405.8; 505.2 1133B.5 .5.1 -PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 131 Ramp PV Net NX Bldg. 07.17 - Inside Handrail On dogleg or switchback ramps, the inside handrail is not continuous. 4.8.5(1) 505.3 1133B.5 .5.1 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 132 Ramp PV Net NX Bldg. Page 28 of 38 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02A - City Hall GroundsReporting: 173 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 07 - Ramps Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 07.20 - Height The top of the handrail is not between 34” and 38” above the ramp surface. 4.8.5 (5) 505.4; Advisory 505.4; Fig. 505.4 1133B.5 .5.1 -33" high PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 133 Ramp PV Net NX Bldg. 07.21B - Extensions - Parallel with Floor or Ground Surface At ends of handrails, the handrail extensions is not parallel to the floor or ground surface. 4.8.5 (2) 505.10; 505.10. 1; Fig. 505.10. 1 1133B.5 .5.1 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 134 Ramp PV Net NX Bldg. 07.24 - Clearance The clear space between handrails and walls is not 1-1/2” absolute. (ADA/CBC Standards apply an absolute dimension of 1-1/2”, which provides knuckle clearance while generally disallowing entrapment of the forearm or elbow.) 4.8.5; 4.26.2; Fig. 39 505.5; Fig. 505.5 1133B.5 .5.1 -2 1/8"PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 135 Ramp PV Net NX Bldg. 07.06 - Clear Width Clear width of the ramp is less than 48“ (handrails may project into the required width a distance of 4-1/2” max.. from each side). 4.8.3 405.5 1133B.5 .2 -45" clr.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 154 Ramp at Ch 33 Bldg. 07.07A - Level Landings Landings at the top or bottom of each ramp or each ramp run is not level (slope is greater than 2% in some or all directions). 4.8.4 405.7; 405.7.1 1133B.5 .4.1 -4.3%PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 155 Ramp at Ch 33 Bldg. 07.11A - Intermediate Landing - Change of Direction Where there is an intermediate landing, and the ramp changes direction (>30-degree), the landing is less than 72” x 60“. 4.8.4(3) 405.7.4 1133B.5 .4.6 -73" long 45" wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 156 Ramp at Ch 33 Bldg. Page 29 of 38 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02A - City Hall GroundsReporting: 173 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 07 - Ramps Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 07.14B - Guards Where drop exceeds 30”, a min.. 42” high guard has not been provided as a vertical barrier along the open edges of ramp or landing to prevent persons from falling off the open edge. 4.8.7 405.9; 405.9.2 1013; 1133B.5 .7 -32 3/4" high guards.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 157 Ramp at Ch 33 Bldg. 07.21A - Extensions - Required Length At ends of handrails, less than 12” of handrail extends beyond the top and bottom of the ramp segment. (Top and bottom handrail extensions are important safety features for persons with mobility impairments and must extend in the direction of the ramp run to permit the intended use.) (Per CBC 1133B.5.5.1.1, in existing buildings or facilities, where the extension of the handrail in the direction of the ramp run would create a hazard, the extension on the handrail may be turned 90 degrees to the run of the ramp.) 4.8.5 (2) 505.10; 505.10. 1; Fig. 505.10. 1 1133B.5 .5.1; 1133B.5 .5.1.1 -One provided.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 158 Ramp at Ch 33 Bldg. 07.24 - Clearance The clear space between handrails and walls is not 1-1/2” absolute. (ADA/CBC Standards apply an absolute dimension of 1-1/2”, which provides knuckle clearance while generally disallowing entrapment of the forearm or elbow.) 4.8.5; 4.26.2; Fig. 39 505.5; Fig. 505.5 1133B.5 .5.1 -2 1/8" clr.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 159 Ramp at Ch 33 Bldg. 07.16 - Handrails Slope of the ramp exceeds 5%, and handrails are not provided on each side. (Per CBC 1133B.5.5.1, at exterior door landings, handrails are not required on ramps less than 6” high or 72” long. Handrails are not required on curb ramps or adjacent to fixed seating in assembly areas.) 4.8.5 405.8; 505.2 1133B.5 .5.1 -PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 160 Ramp at Ch 33 Bldg. 16Number of Key Notes for Group 07 - Ramps: Group 08 - Stairs Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation Page 30 of 38 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02A - City Hall GroundsReporting: 173 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 08 - Stairs Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 08.02B - Riser Height The risers are not uniform. OR The risers are not between 4” and 7” in height. 4.9.2 504.2 1009.3; 1133B.4 .5.3 -8" high.EW - Employee Work Area A - Safety Hazard 6 - Employee- Only Work Areas (1994 ADAS 4.1.1(3)) 44 W. PV Net Bldg. 08.03D - Level Landing Landing is not level (slope is greater than 2% in some or all directions). --1009.5. 1 -3.5%EW - Employee Work Area C - Partial Barrier to Access 6 - Employee- Only Work Areas (1994 ADAS 4.1.1(3)) 45 W. PV Net Bldg. 08.05A - Exterior Stairs - Color Strip Contrasting color strips have not been provided. --1133B.4 .4 -EW - Employee Work Area A - Safety Hazard 6 - Employee- Only Work Areas (1994 ADAS 4.1.1(3)) 46 W. PV Net Bldg. 08.07A - Continuous Handrails Continuous handrails are not provided along both sides. 4.9.4 504.6; 505.2 1133B.4 .1.1 -2x Guard w/ no handrails EW - Employee Work Area C - Partial Barrier to Access 6 - Employee- Only Work Areas (1994 ADAS 4.1.1(3)) 47 W. PV Net Bldg. 08.05A - Exterior Stairs - Color Strip Contrasting color strips have not been provided. --1133B.4 .4 -EC - Employee Common Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 52 N. of Comm. Dev. Bldg. 08.07A - Continuous Handrails Continuous handrails are not provided along both sides. 4.9.4 504.6; 505.2 1133B.4 .1.1 -EC - Employee Common Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 53 N. of Comm. Dev. Bldg. 08.02B - Riser Height The risers are not uniform. OR The risers are not between 4” and 7” in height. 4.9.2 504.2 1009.3; 1133B.4 .5.3 -3" & 3 1/2" high PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 101 Picnic Area S. of PV Net Bldg. Page 31 of 38 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02A - City Hall GroundsReporting: 173 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 08 - Stairs Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 08.03A - Tread Depth The treads are not uniform. OR The treads are less than 11” deep measured from riser to riser. 4.9.2 504.2 1009.3; 1133B.4 .5.3 -29"PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 102 Picnic Area S. of PV Net Bldg. 08.02A - Open Risers The risers are not closed.4.9.2 504.3 1133B.4 .5.3 -PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 113 Stairs at PV Net NX Bldg. 08.05A - Exterior Stairs - Color Strip Contrasting color strips have not been provided. --1133B.4 .4 -PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 114 Stairs at PV Net NX Bldg. 08.07A - Continuous Handrails Continuous handrails are not provided along both sides. 4.9.4 504.6; 505.2 1133B.4 .1.1 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 115 Stairs at PV Net NX Bldg. 08.09A - Handrail Extensions - Top Landing At ends of handrails, less than 12” of handrail extends beyond the top nosing. (Top and bottom handrail extensions are important safety features for persons with balance problems and must extend in the direction of the stair run to permit the intended use.) (Per ADA/CBC Standards, in existing buildings and facilities, full extension of handrails at stairs shall not be required in alterations where such extensions would be hazardous or impossible due to plan configuration.) 4.9.4(2) 505.10; 505.10. 2; Fig. 505.10. 2 1133B.4 .2.2 -None PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 116 Stairs at PV Net NX Bldg. Page 32 of 38 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02A - City Hall GroundsReporting: 173 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 08 - Stairs Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 08.09B - Handrail Extensions - Bottom Landing At ends of handrails, less than 12” plus the tread width extends beyond the bottom nosing. (Top and bottom handrail extensions are important safety features for persons with balance problems and must extend in the direction of the stair run to permit the intended use.) (Per ADA/CBC Standards, in existing buildings and facilities, full extension of handrails at stairs shall not be required in alterations where such extensions would be hazardous or impossible due to plan configuration.) 4.9.4(2) 505.10; 505.10. 3; Fig. 505.10. 3 1133B.4 .2.2 -None PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 117 Stairs at PV Net NX Bldg. 08.10B - Clearance The clear space between handrails and walls is not 1-1/2” absolute. (ADA/CBC Standards apply an absolute dimension of 1-1/2”, which provides knuckle clearance while generally disallowing entrapment of the forearm or elbow.) 4.9.5(3) 505.5 1133B.4 .2.5 -2 1/8"PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 118 Stairs at PV Net NX Bldg. 14Number of Key Notes for Group 08 - Stairs: Group 06 - Telephones Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 06.02B - ISA Sign The wheelchair accessible telephone is not identified by the ISA. 4.1.3(17 )(b); 4.30.7(1 ) 703.2.1; Fig. 703.2.1 1117B.5 .8.1 -PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 27 E. of Admin. Bldg. 1Number of Key Notes for Group 06 - Telephones: Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation Page 33 of 38 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02A - City Hall GroundsReporting: 173 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.01 - Toilet Rooms Toilet room does not comply with all applicable ADAAG and CBC accessibility requirements. 4.1.2(6) ; 4.1.3(11 ); 4.22.1 213.2; Advisory 213.2 1115B.1 -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 79 Portable Restroom NE. of PV Net Bldg. 16.04 - Accessible Path of Travel Toilet room is not located on an accessible route of travel. 4.22.1 206.2.4; Advisory 206.2.4 1115B.1 -None provided, 4.6% CS.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 80 Portable Restroom NE. of PV Net Bldg. 16.12 - Other Door Requirements Door does not comply with all applicable ADAAG and CBC accessibility requirements. 4.13 404.1; Advisory 404.1 1133B.2 -From an open position of 70 degrees, the door takes 1 seconds to move to a point 3” from the latch. PV - Public/Visitor Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 81 Portable Restroom NE. of PV Net Bldg. 16.13C - Unisex RR Geometric Symbol Signage - Circle/Triangle Doorway leading to a unisex toilet room is not identified by a 12” circle, 1/4" with a 1/4" thick triangle superimposed and within the circle. OR Circle and triangle are provided, however they are accompanied by words in raised characters and Braille. (ADA and CBC Standards require a separate sign with raised characters and Braille mounted on the wall adjacent to the latch side of the door.) --1115B.6 -None provided PV - Public/Visitor Use D - Minor Code Deviation 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 82 Portable Restroom NE. of PV Net Bldg. 16.15A - Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.30.1 216.2; 703.1; 703.2; 703.5 1117B.5 .1(1) -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 83 Portable Restroom NE. of PV Net Bldg. 16.26A - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -4.6%PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 84 Portable Restroom NE. of PV Net Bldg. Page 34 of 38 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02A - City Hall GroundsReporting: 173 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.27A - 60” Wide Circle or T- Shaped Maneuvering Space The toilet room does not include an unobstructed turning space (a 60” diameter, 27" high circle or T-shaped space). (Note: The clear floor space of fixtures and controls, the accessible path of travel, and the turning space may overlap.) 4.22.3; Fig 3 304.3.2; Fig.304. 3.2; 603.2.1 1115B.3 .1(1); 1115B.3 .2(1) -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 85 Portable Restroom NE. of PV Net Bldg. 16.43 - WC not in Stalls - Front Transfer Space Where the WC is not in a stall, the clear floor space in front of the WC is less than 60" wide by 48" deep. --1115B.4 .1(2) -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 86 Portable Restroom NE. of PV Net Bldg. 16.47A - WC Location from Sidewall The centerline of the WC is not 18” absolute from a wall or partition. 4.22.4 -1115B.4 .1(1) -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 87 Portable Restroom NE. of PV Net Bldg. 16.50 - TP Dispenser - Location - Pre- 2007 CBC Facility Location of the toilet paper dispenser does not comply with the Standard in effect at the time of construction. (The 2001 CBC required toilet tissue dispensers located on the wall within 12" of the front edge of the toilet seat, measured to the centerline of the dispenser; mounted below the grab bar; and centered at a min. height of 19" AFF.) 4.16.6; Fig. 29(b) 604.7; Advisory 604.7; Fig. 604.7 --13"PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 88 Portable Restroom NE. of PV Net Bldg. 16.53 - SC Dispenser Height Mounting height of seat cover dispenser's highest operable part exceeds 40" AFF. 4.22.7; 4.27.3; 4.2.5; 4.2.6 -1115B.8 .3 -45" high PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 89 Portable Restroom NE. of PV Net Bldg. Page 35 of 38 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02A - City Hall GroundsReporting: 173 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.54B - Side Grab Bar Length Side grab bar is less than 42” long. (ADA Standards require the side grab bar for WC's not located in stalls to be 42" long min..; ADA Standards require the side grab bar for WC's located in stalls to be 40" to 42" long min..; CBC Standards require the side grab bar to be 42" long min..) 4.17.6; Figs. 29 & 30 604.5; Advisory 604.5; 604.5.1; Fig. 604.5.1; 609.4 1115B.4 .1(3.1); Fig. 11B-1A -37" long PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 90 Portable Restroom NE. of PV Net Bldg. 16.55A - Side Grab Bar Height Side grab bar is not centered at 33" AFF. (ADA Standards require side grab bars to be centered from 33" to 36" AFF; CBC Standards require side grab bars to be centered at 33" AFF.) 4.17.6; Figs. 29 & 30 604.5; Advisory 604.5; 604.5.2; Fig. 604.5.2; 609.4 1115B.4 .1(3.1); Fig. 11B-1A -34 1/2" high PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 91 Portable Restroom NE. of PV Net Bldg. 16.56 - Grab Bar Wall Clearance The space between the grab bar and the wall is not 1-1/2” absolute. 4.17.6, 4.26.2; Fig. 39 609.3 1115B.7 .1; Fig. 11B-1C -1 5/8" clr.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 92 Portable Restroom NE. of PV Net Bldg. 16.84C - Soap Dispenser - Operating Height Mounting height of soap dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one soap dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one soap dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -46" high PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 93 Portable Restroom NE. of PV Net Bldg. Page 36 of 38 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02A - City Hall GroundsReporting: 173 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.70 - Lavatories Lavatory does not comply with ADAAG and CBC requirements. (ADA Standards require at least one lavatory to be accessible. CBC Standards prior to August 1, 2009 required all lavatories to be accessible. Effective August 1, 2009, amended CBC Standards require at least 5% of lavatories, but not less than one lavatory, to be accessible.) 4.22.6 213.3.4; 606.1 1115B.4 .3 -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 94 Portable Restroom NE. of PV Net Bldg. 16.71 - Lavatory - Rim Height Height of lavatory rim or counter surface exceeds 34” AFF. 4.19.2; Fig. 31 606.3 1115B.4 .3(2); Fig 11B- 1D -39 1/2" high PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 95 Portable Restroom NE. of PV Net Bldg. 16.73 - Lavatory Knee Clearance Lavatory does not provide accessible knee clearance (i.e. at least 27” clearance from the floor to the underside of the lavatory, extending 8” min.. measured from the front edge underneath the lavatory back towards the wall). 4.19.2; Fig. 31 306.3; Fig. 306.3 1115B.4 .3(2); Fig 11B- 1D -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 96 Portable Restroom NE. of PV Net Bldg. 16.84A - Paper Towel Dispenser - Operating Height Mounting height of paper towel dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one paper towel dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one paper towel dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -53" high PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 97 Portable Restroom NE. of PV Net Bldg. Page 37 of 38 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02A - City Hall GroundsReporting: 173 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.84C - Soap Dispenser - Operating Height Mounting height of soap dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one soap dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one soap dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -45" high PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 98 Portable Restroom NE. of PV Net Bldg. 20Number of Key Notes for Group 16 - Toilet Facilities: 173Number of Key Notes for Facility 02A - City Hall Grounds: 173Total Number of Key Notes for All Groups: Page 38 of 38 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA