Loading...
City Hall Buildings Part 3 Page 1-160_ComplianceReport_20130509-113435Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 20 - Alarms Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 20.02 - Toilet, Bathroom, or Shower Room - Visual Alarms Visual alarms are not provided at public or common use toilet, bathroom, or shower room. 4.28.1 215.1; Advisory 215.1; 702.1 907.9.1. 1 -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 97 Comm. Dev. - Public Restroom 20.02 - Toilet, Bathroom, or Shower Room - Visual Alarms Visual alarms are not provided at public or common use toilet, bathroom, or shower room. 4.28.1 215.1; Advisory 215.1; 702.1 907.9.1. 1 -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 99 Comm. Dev. - Men's Staff Restroom 20.03 - General Use Areas - Visual Alarms Visual alarms are not provided at public use area(s) of the building such as waiting areas, assembly areas, meeting rooms, corridors, stairways, hallways, and lobbies. (Visual alarms are not required in enclosed exit stairways, exterior exit stairs and exterior exit ramps.) 4.28.1 215.1; Advisory 215.1; 702.1 907.9.1. 1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 120 Comm. Dev. - Vestibule 20.02 - Toilet, Bathroom, or Shower Room - Visual Alarms Visual alarms are not provided at public or common use toilet, bathroom, or shower room. 4.28.1 215.1; Advisory 215.1; 702.1 907.9.1. 1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 121 Comm. Dev. - Women's Staff Restroom 20.04 - Common Use Areas - Visual Alarms Visual alarms are not provided in common use area(s) of the building such as meeting and conference rooms, open office space, classrooms, cafeterias, filing and photocopy rooms, employee break rooms, dressing, examination, and treatment rooms, and similar spaces that are not used solely as employee work areas. 4.28.1 215.2; 702.1 907.9.1. 1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 143 Comm. Dev. - Lobby Page 1 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 20 - Alarms Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 20.04 - Common Use Areas - Visual Alarms Visual alarms are not provided in common use area(s) of the building such as meeting and conference rooms, open office space, classrooms, cafeterias, filing and photocopy rooms, employee break rooms, dressing, examination, and treatment rooms, and similar spaces that are not used solely as employee work areas. 4.28.1 215.2; 702.1 907.9.1. 1 -EC - Employee Common Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 147 Comm. Dev. - Office 20.04 - Common Use Areas - Visual Alarms Visual alarms are not provided in common use area(s) of the building such as meeting and conference rooms, open office space, classrooms, cafeterias, filing and photocopy rooms, employee break rooms, dressing, examination, and treatment rooms, and similar spaces that are not used solely as employee work areas. 4.28.1 215.2; 702.1 907.9.1. 1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 162 Comm. Dev. - Cashier 20.03 - General Use Areas - Visual Alarms Visual alarms are not provided at public use area(s) of the building such as waiting areas, assembly areas, meeting rooms, corridors, stairways, hallways, and lobbies. (Visual alarms are not required in enclosed exit stairways, exterior exit stairs and exterior exit ramps.) 4.28.1 215.1; Advisory 215.1; 702.1 907.9.1. 1 -EC - Employee Common Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 165 Comm. Dev. - Hallway 20.04 - Common Use Areas - Visual Alarms Visual alarms are not provided in common use area(s) of the building such as meeting and conference rooms, open office space, classrooms, cafeterias, filing and photocopy rooms, employee break rooms, dressing, examination, and treatment rooms, and similar spaces that are not used solely as employee work areas. 4.28.1 215.2; 702.1 907.9.1. 1 -EC - Employee Common Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 169 Comm. Dev. - Office Page 2 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 20 - Alarms Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 20.04 - Common Use Areas - Visual Alarms Visual alarms are not provided in common use area(s) of the building such as meeting and conference rooms, open office space, classrooms, cafeterias, filing and photocopy rooms, employee break rooms, dressing, examination, and treatment rooms, and similar spaces that are not used solely as employee work areas. 4.28.1 215.2; 702.1 907.9.1. 1 -EC - Employee Common Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 175 Comm. Dev. - Office 20.03 - General Use Areas - Visual Alarms Visual alarms are not provided at public use area(s) of the building such as waiting areas, assembly areas, meeting rooms, corridors, stairways, hallways, and lobbies. (Visual alarms are not required in enclosed exit stairways, exterior exit stairs and exterior exit ramps.) 4.28.1 215.1; Advisory 215.1; 702.1 907.9.1. 1 -EC - Employee Common Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 202 Comm. Dev. - Open Office 20.04 - Common Use Areas - Visual Alarms Visual alarms are not provided in common use area(s) of the building such as meeting and conference rooms, open office space, classrooms, cafeterias, filing and photocopy rooms, employee break rooms, dressing, examination, and treatment rooms, and similar spaces that are not used solely as employee work areas. 4.28.1 215.2; 702.1 907.9.1. 1 -EC - Employee Common Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 212 Comm. Dev. - Open Office 20.04 - Common Use Areas - Visual Alarms Visual alarms are not provided in common use area(s) of the building such as meeting and conference rooms, open office space, classrooms, cafeterias, filing and photocopy rooms, employee break rooms, dressing, examination, and treatment rooms, and similar spaces that are not used solely as employee work areas. 4.28.1 215.2; 702.1 907.9.1. 1 -EC - Employee Common Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 217 Comm. Dev. - Break Room Page 3 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 20 - Alarms Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 20.03 - General Use Areas - Visual Alarms Visual alarms are not provided at public use area(s) of the building such as waiting areas, assembly areas, meeting rooms, corridors, stairways, hallways, and lobbies. (Visual alarms are not required in enclosed exit stairways, exterior exit stairs and exterior exit ramps.) 4.28.1 215.1; Advisory 215.1; 702.1 907.9.1. 1 -EC - Employee Common Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 219 Comm. Dev. - Hallway 20.16B - Surface-Mounted Fire Extinguisher - Mounting Height Where fire extinguishers are surface-mounted, mounting height of the extinguisher is not compliant. (Compliant surface-mounted extinguisher is 48” AFF maximum, as measured to the highest operable part, or in existing buildings, when the extinguisher is 54” AFF and parallel approach is provided) 4.27.3 308.2.1; Fig. 308.2.1; 308.3.1; Fig. 308.3.1 1118B.4 (1); 1118B.5 ; 1118B.6 -52" AFF.EC - Employee Common Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 220 Comm. Dev. - Hallway 20.04 - Common Use Areas - Visual Alarms Visual alarms are not provided in common use area(s) of the building such as meeting and conference rooms, open office space, classrooms, cafeterias, filing and photocopy rooms, employee break rooms, dressing, examination, and treatment rooms, and similar spaces that are not used solely as employee work areas. 4.28.1 215.2; 702.1 907.9.1. 1 -EC - Employee Common Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 222 Comm. Dev. - Office 20.04 - Common Use Areas - Visual Alarms Visual alarms are not provided in common use area(s) of the building such as meeting and conference rooms, open office space, classrooms, cafeterias, filing and photocopy rooms, employee break rooms, dressing, examination, and treatment rooms, and similar spaces that are not used solely as employee work areas. 4.28.1 215.2; 702.1 907.9.1. 1 -EC - Employee Common Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 241 Comm. Dev. - Conference Rm Page 4 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 20 - Alarms Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 20.04 - Common Use Areas - Visual Alarms Visual alarms are not provided in common use area(s) of the building such as meeting and conference rooms, open office space, classrooms, cafeterias, filing and photocopy rooms, employee break rooms, dressing, examination, and treatment rooms, and similar spaces that are not used solely as employee work areas. 4.28.1 215.2; 702.1 907.9.1. 1 -EC - Employee Common Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 248 Comm. Dev. - Copy Rm 20.16B - Surface-Mounted Fire Extinguisher - Mounting Height Where fire extinguishers are surface-mounted, mounting height of the extinguisher is not compliant. (Compliant surface-mounted extinguisher is 48” AFF maximum, as measured to the highest operable part, or in existing buildings, when the extinguisher is 54” AFF and parallel approach is provided) 4.27.3 308.2.1; Fig. 308.2.1; 308.3.1; Fig. 308.3.1 1118B.4 (1); 1118B.5 ; 1118B.6 -64" high GS - General Student Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 343 Admin. - East Stairwell 20.16B - Surface-Mounted Fire Extinguisher - Mounting Height Where fire extinguishers are surface-mounted, mounting height of the extinguisher is not compliant. (Compliant surface-mounted extinguisher is 48” AFF maximum, as measured to the highest operable part, or in existing buildings, when the extinguisher is 54” AFF and parallel approach is provided) 4.27.3 308.2.1; Fig. 308.2.1; 308.3.1; Fig. 308.3.1 1118B.4 (1); 1118B.5 ; 1118B.6 -61" AFF.EC - Employee Common Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 422 Admin. - Hallway 20.16B - Surface-Mounted Fire Extinguisher - Mounting Height Where fire extinguishers are surface-mounted, mounting height of the extinguisher is not compliant. (Compliant surface-mounted extinguisher is 48” AFF maximum, as measured to the highest operable part, or in existing buildings, when the extinguisher is 54” AFF and parallel approach is provided) 4.27.3 308.2.1; Fig. 308.2.1; 308.3.1; Fig. 308.3.1 1118B.4 (1); 1118B.5 ; 1118B.6 -61" high.EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 507 Admin. S. Corridor Page 5 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 20 - Alarms Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 20.16B - Surface-Mounted Fire Extinguisher - Mounting Height Where fire extinguishers are surface-mounted, mounting height of the extinguisher is not compliant. (Compliant surface-mounted extinguisher is 48” AFF maximum, as measured to the highest operable part, or in existing buildings, when the extinguisher is 54” AFF and parallel approach is provided) 4.27.3 308.2.1; Fig. 308.2.1; 308.3.1; Fig. 308.3.1 1118B.4 (1); 1118B.5 ; 1118B.6 -60" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 531 Admin. - Open Office 20.16B - Surface-Mounted Fire Extinguisher - Mounting Height Where fire extinguishers are surface-mounted, mounting height of the extinguisher is not compliant. (Compliant surface-mounted extinguisher is 48” AFF maximum, as measured to the highest operable part, or in existing buildings, when the extinguisher is 54” AFF and parallel approach is provided) 4.27.3 308.2.1; Fig. 308.2.1; 308.3.1; Fig. 308.3.1 1118B.4 (1); 1118B.5 ; 1118B.6 -59" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 594 Admin. - Stair Well 20.16B - Surface-Mounted Fire Extinguisher - Mounting Height Where fire extinguishers are surface-mounted, mounting height of the extinguisher is not compliant. (Compliant surface-mounted extinguisher is 48” AFF maximum, as measured to the highest operable part, or in existing buildings, when the extinguisher is 54” AFF and parallel approach is provided) 4.27.3 308.2.1; Fig. 308.2.1; 308.3.1; Fig. 308.3.1 1118B.4 (1); 1118B.5 ; 1118B.6 -61" AFF.EC - Employee Common Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 652 Admin. - Hallway 20.16B - Surface-Mounted Fire Extinguisher - Mounting Height Where fire extinguishers are surface-mounted, mounting height of the extinguisher is not compliant. (Compliant surface-mounted extinguisher is 48” AFF maximum, as measured to the highest operable part, or in existing buildings, when the extinguisher is 54” AFF and parallel approach is provided) 4.27.3 308.2.1; Fig. 308.2.1; 308.3.1; Fig. 308.3.1 1118B.4 (1); 1118B.5 ; 1118B.6 -59" AFF.EC - Employee Common Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 722 Admin. - Hallway 25Number of Key Notes for Group 20 - Alarms: Group 17 - Bathing and Shower Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation Page 6 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 17 - Bathing and Shower Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 17.01 - Accessible Bathing or Showering Facilities Where facilities for bathing or showering are provided, less than 1% of these facilities are accessible. 4.23.1; 4.23.8 213.3.6 1115B.2 -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 60 Ch. 33 - Restroom 17.01 - Accessible Bathing or Showering Facilities Where facilities for bathing or showering are provided, less than 1% of these facilities are accessible. 4.23.1; 4.23.8 213.3.6 1115B.2 -Non compliant shower EC - Employee Common Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 449 Admin. - Unisex Restrm. 2Number of Key Notes for Group 17 - Bathing and Shower Facilities: Group 15B - Conference and Meeting Rooms Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 15B.19 - Assistive Listening Systems (ALS) For assembly areas without fixed seats (e.g.. conference or meeting rooms), a permanently installed assistive listening system or a portable assistive listening system, including an adequate number of electrical outlets or other supplementary wiring necessary to support a portable ALS, has not been provided. (A permanently installed ALS is required where (1) the assembly area accommodates 50 or more persons or has an audio-amplification system and (2) it has fixed seats.) (If portable assistive- listening systems are used for conference or meeting rooms, the system may serve more than one room.) 4.1.3(19 )(b) 219.2; 219.3; Tab. 219.3 1104B.2 item 6 -EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 240 Comm. Dev. - Conference Rm Page 7 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 15B - Conference and Meeting Rooms Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 15B.19 - Assistive Listening Systems (ALS) For assembly areas without fixed seats (e.g.. conference or meeting rooms), a permanently installed assistive listening system or a portable assistive listening system, including an adequate number of electrical outlets or other supplementary wiring necessary to support a portable ALS, has not been provided. (A permanently installed ALS is required where (1) the assembly area accommodates 50 or more persons or has an audio-amplification system and (2) it has fixed seats.) (If portable assistive- listening systems are used for conference or meeting rooms, the system may serve more than one room.) 4.1.3(19 )(b) 219.2; 219.3; Tab. 219.3 1104B.2 item 6 -GS - General Student Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 325 Admin. - Conf. 15B.19 - Assistive Listening Systems (ALS) For assembly areas without fixed seats (e.g.. conference or meeting rooms), a permanently installed assistive listening system or a portable assistive listening system, including an adequate number of electrical outlets or other supplementary wiring necessary to support a portable ALS, has not been provided. (A permanently installed ALS is required where (1) the assembly area accommodates 50 or more persons or has an audio-amplification system and (2) it has fixed seats.) (If portable assistive- listening systems are used for conference or meeting rooms, the system may serve more than one room.) 4.1.3(19 )(b) 219.2; 219.3; Tab. 219.3 1104B.2 item 6 -EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 493 Admin. Conference Rm. Page 8 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 15B - Conference and Meeting Rooms Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 15B.19 - Assistive Listening Systems (ALS) For assembly areas without fixed seats (e.g.. conference or meeting rooms), a permanently installed assistive listening system or a portable assistive listening system, including an adequate number of electrical outlets or other supplementary wiring necessary to support a portable ALS, has not been provided. (A permanently installed ALS is required where (1) the assembly area accommodates 50 or more persons or has an audio-amplification system and (2) it has fixed seats.) (If portable assistive- listening systems are used for conference or meeting rooms, the system may serve more than one room.) 4.1.3(19 )(b) 219.2; 219.3; Tab. 219.3 1104B.2 item 6 -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 514 Admin. - Conference Room 15B.18B - 36" Width Standard The accessible route of travel is less than 36” wide where the occupancy load is < 10. (For a depth of 24" max.., clear opening width may be reduced to 32" min..) (Doorways are compliant when the door, open 90 degrees, affords a clear opening width of at least 32”.) 4.3.3 403.5.1 1133B.3 .1 -21", 22", 27 1/2", & 30 1/2" clear. PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 516 Admin. - Conference Room 15B.19 - Assistive Listening Systems (ALS) For assembly areas without fixed seats (e.g.. conference or meeting rooms), a permanently installed assistive listening system or a portable assistive listening system, including an adequate number of electrical outlets or other supplementary wiring necessary to support a portable ALS, has not been provided. (A permanently installed ALS is required where (1) the assembly area accommodates 50 or more persons or has an audio-amplification system and (2) it has fixed seats.) (If portable assistive- listening systems are used for conference or meeting rooms, the system may serve more than one room.) 4.1.3(19 )(b) 219.2; 219.3; Tab. 219.3 1104B.2 item 6 -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 605 Admin. - Conference Room Page 9 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 15B - Conference and Meeting Rooms Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 6Number of Key Notes for Group 15B - Conference and Meeting Rooms: Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.12 - Hardware Mounting Height Mounting height of all operating hardware is not 30” min.. or 44” max.., as measured to the highest operable part. (1994 ADA Standards permit a max.. height of 48"; CBC Standards permit a range of 30” min.. to 44” max..) 4.13.9 -1133B.2 .5.2 -59 1/2" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 5 Ch. 33 - Office 11.12 - Hardware Mounting Height Mounting height of all operating hardware is not 30” min.. or 44” max.., as measured to the highest operable part. (1994 ADA Standards permit a max.. height of 48"; CBC Standards permit a range of 30” min.. to 44” max..) 4.13.9 -1133B.2 .5.2 -Number pad at 44 1/2" AFF, Deadbolt at 49 1/2" AFF & latch at 58". PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 6 Ch. 33 - Office 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Door knob.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 16 Ch. 33 - Sound Stage 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 17 Ch. 33 - Sound Stage 11.10B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -5/8" change in level.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 18 Ch. 33 - Sound Stage Page 10 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.05A - Clear Opening - Single- Leaf Door When the door is open 90 degrees, clear opening width is not at least 32” measured between the face of the door and the doorstop on the latch side. 4.13.5 404.2.3 1133B.1 .1.1.1; 1133B.2 .2 -27 1/2" clear opening.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 22 Ch. 33 - Sound Stage 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Door knob.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 23 Ch. 33 - Sound Stage 11.21A - Required Exit Route Sign At exit access door from an interior room or area that is required to have a visual exit sign, there is no tactile and CA Braille exit sign with the words “EXIT ROUTE” mounted on the wall adjacent to the latch side of the door. (Visual exit signs are required when two or more exits are required. Generally, all occupants shall have access to two exits from a floor (CBC Table 1019.1). Exceptions: a) Single story building with maximum occupant load of 49 and less than 75 ft travel distance to exit (CBC Table 1019.2), and b) Two story building with maximum occupant load of 30 occupants per floor and maximum travel distance of 75 ft to exit. (CBC Table 1019.2). Two exit access doors are required from an office tenant space when the occupant load exceeds 49.) 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 4 -PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 24 Ch. 33 - Sound Stage 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Door knob.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 29 Ch. 33 - Storage Page 11 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Door knob & twist-type locking mechanism. PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 31 Ch. 33 - Control Room 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -12 1/2" pull side.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 32 Ch. 33 - Control Room 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 34 Ch. 33 - Control Room Page 12 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -1 3/4" pull side & 43" landing at pull side. PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 39 Ch. 33 - Control Room 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Door knob & twist-type locking mechanism. PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 40 Ch. 33 - Control Room 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 41 Ch. 33 - Control Room 11.04 - Gates Gate does not comply with all applicable ADAAG and CBC accessibility requirements for doors. (ADAAG and CBC accessibility requirements for doors apply to gates, including ticket gates.) 4.13.3 404.2; 404.3 1133B.1 .1.1.4 -Bottom of swing gate is 16 1/4" AFF. EC - Employee Common Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 140 Comm. Dev. - Planning Dept. Counter Page 13 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.15A - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -Bottom of vent grill at 2 1/2" AFF. EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 144 Comm. Dev. - Server Room 11.12 - Hardware Mounting Height Mounting height of all operating hardware is not 30” min.. or 44” max.., as measured to the highest operable part. (1994 ADA Standards permit a max.. height of 48"; CBC Standards permit a range of 30” min.. to 44” max..) 4.13.9 -1133B.2 .5.2 -Lock at 45 1/2" AFF.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 145 Comm. Dev. - Server Room 11.10B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -3/4" change in level.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 149 Comm. Dev. - Office 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -4" at pull side, non-fixed furniture. EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 150 Comm. Dev. - Office Page 14 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -EC - Employee Common Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 151 Comm. Dev. - Office 11.04 - Gates Gate does not comply with all applicable ADAAG and CBC accessibility requirements for doors. (ADAAG and CBC accessibility requirements for doors apply to gates, including ticket gates.) 4.13.3 404.2; 404.3 1133B.1 .1.1.4 -Bottom of swing gate at 16 1/4" AFF. EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 157 Comm. Dev. - Open Office 11.17B - Room/Space Identification Signs (Visual/Tactile Signs) Sign designating the permanent room or space does not comply with ADAAG and CBC requirements for tactile signs. 4.1.2(7) ; 4.30.1, 4, 5, 6 216.2; 703.1; 703.2; 703.5 1117B.5 .2, 3, 5, 6, 7 -PV - Public/Visitor Use D - Minor Code Deviation 1 - Access into Facilities (28 CFR 36.304(c)(1)) 158 Comm. Dev. - Cashier 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -Non-fixed furniture encroaches swing gate landing. EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 160 Comm. Dev. - Cashier Page 15 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.17B - Room/Space Identification Signs (Visual/Tactile Signs) Sign designating the permanent room or space does not comply with ADAAG and CBC requirements for tactile signs. 4.1.2(7) ; 4.30.1, 4, 5, 6 216.2; 703.1; 703.2; 703.5 1117B.5 .2, 3, 5, 6, 7 -PV - Public/Visitor Use D - Minor Code Deviation 2 - Program Areas (28 CFR 36.304(c)(2)) 166 Comm. Dev. - Office 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -53" door landing at pull side, non-fixed furniture. EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 167 Comm. Dev. - Office 11.17B - Room/Space Identification Signs (Visual/Tactile Signs) Sign designating the permanent room or space does not comply with ADAAG and CBC requirements for tactile signs. 4.1.2(7) ; 4.30.1, 4, 5, 6 216.2; 703.1; 703.2; 703.5 1117B.5 .2, 3, 5, 6, 7 -PV - Public/Visitor Use D - Minor Code Deviation 2 - Program Areas (28 CFR 36.304(c)(2)) 171 Comm. Dev. - Office Page 16 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -12" pull side, non-fixed furniture. EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 173 Comm. Dev. - Office 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 180 Comm. Dev. - Office 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -Non-fixed furniture encroaches pull side door landing. EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 181 Comm. Dev. - Office Page 17 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Twist-type lock.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 182 Comm. Dev. - Office 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 185 Comm. Dev. - Office 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -Non-fixed furniture encroaches door landing at pull side. EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 186 Comm. Dev. - Office 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 189 Comm. Dev. - Office Page 18 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -3" maneuvering space at pull side, wall. EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 190 Comm. Dev. - Office 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Twist-type lock.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 191 Comm. Dev. - Office 11.17B - Room/Space Identification Signs (Visual/Tactile Signs) Sign designating the permanent room or space does not comply with ADAAG and CBC requirements for tactile signs. 4.1.2(7) ; 4.30.1, 4, 5, 6 216.2; 703.1; 703.2; 703.5 1117B.5 .2, 3, 5, 6, 7 -EW - Employee Work Area D - Minor Code Deviation 2 - Program Areas (28 CFR 36.304(c)(2)) 194 Admin. - Office Page 19 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -9 1/4" pull side, CMU wall.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 204 Comm. Dev. - Office 11.05A - Clear Opening - Single- Leaf Door When the door is open 90 degrees, clear opening width is not at least 32” measured between the face of the door and the doorstop on the latch side. 4.13.5 404.2.3 1133B.1 .1.1.1; 1133B.2 .2 -26" clear.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 205 Comm. Dev. - Office 11.15A - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -8 1/2".EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 206 Comm. Dev. - Office 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Twist-type lock.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 207 Comm. Dev. - Office Page 20 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.12 - Hardware Mounting Height Mounting height of all operating hardware is not 30” min.. or 44” max.., as measured to the highest operable part. (1994 ADA Standards permit a max.. height of 48"; CBC Standards permit a range of 30” min.. to 44” max..) 4.13.9 -1133B.2 .5.2 -Twist-type lock at 48" AFF.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 208 Comm. Dev. - Office 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -EW - Employee Work Area E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 210 Comm. Dev. - Office 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -51" door landing at pull side, non-fixed furniture. EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 214 Comm. Dev. - Office 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 215 Comm. Dev. - Office Page 21 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -EC - Employee Common Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 216 Comm. Dev. - Office 11.07A - Landing - Level and Clear Floor is not level (slope is greater than 2% in some or all directions). OR Floor is not clear within the required maneuvering space. 4.13.6; Fig. 25 305; 404.2.4. 4 1133B.2 .4 -Non-fixed furniture encroaches door landing at pull side. EC - Employee Common Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 223 Comm. Dev. - Office 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -2 3/4" maneuvering space at pull side. EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 224 Comm. Dev. - Office 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Twist-type lock.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 226 Comm. Dev. - Office Page 22 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.15B_04AG - Vision Lights Door, gate, or adjacent sidelight, containing one or more vision lights, does not include at least one vision light mounted with the bottom edge of the glazed panel at 43" max.. AFF. (Exception: Vision lights with the lowest part more than 66" AFF.) -404.2.1 1 --60" AFF.EC - Employee Common Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 234 Comm. Dev. - Conference Rm 11.12 - Hardware Mounting Height Mounting height of all operating hardware is not 30” min.. or 44” max.., as measured to the highest operable part. (1994 ADA Standards permit a max.. height of 48"; CBC Standards permit a range of 30” min.. to 44” max..) 4.13.9 -1133B.2 .5.2 -75" to latch.EC - Employee Common Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 235 Comm. Dev. - Conference Rm 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -EC - Employee Common Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 237 Comm. Dev. - Conference Rm 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -11" maneuvering space at pull side, non-fixed furniture. EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 239 Comm. Dev. - Conference Rm Page 23 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -0" maneuvering space at pull side, copy machine. EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 244 Comm. Dev. - Copy Rm 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 245 Comm. Dev. - Copy Rm 11.23A - Mounting Location (Visual/Tactile Signs) Sign is not mounted on the wall adjacent to the latch side of the door. OR At double leaf doors, the sign is not placed on the nearest adjacent wall. 4.30.6 703.4.2 1117B.5 .7 -Mounted on door EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 249 Admin. - Office 11.15B_04AG - Vision Lights Door, gate, or adjacent sidelight, containing one or more vision lights, does not include at least one vision light mounted with the bottom edge of the glazed panel at 43" max.. AFF. (Exception: Vision lights with the lowest part more than 66" AFF.) -404.2.1 1 --54" AFF.EC - Employee Common Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 259 Comm. Dev. - Copy Rm Page 24 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.12 - Hardware Mounting Height Mounting height of all operating hardware is not 30” min.. or 44” max.., as measured to the highest operable part. (1994 ADA Standards permit a max.. height of 48"; CBC Standards permit a range of 30” min.. to 44” max..) 4.13.9 -1133B.2 .5.2 -Latch lock at 75" AFF.EC - Employee Common Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 261 Comm. Dev. - Copy Rm 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -42 1/2" deep landing at pull side MS - Maintenance and Storage Only C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 272 Admin. - Central Stairwell 11.04 - Gates Gate does not comply with all applicable ADAAG and CBC accessibility requirements for doors. (ADAAG and CBC accessibility requirements for doors apply to gates, including ticket gates.) 4.13.3 404.2; 404.3 1133B.1 .1.1.4 -18" wide gate & 26 3/4" toe space. EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 274 Admin. - Open Office 11.17B - Room/Space Identification Signs (Visual/Tactile Signs) Sign designating the permanent room or space does not comply with ADAAG and CBC requirements for tactile signs. 4.1.2(7) ; 4.30.1, 4, 5, 6 216.2; 703.1; 703.2; 703.5 1117B.5 .2, 3, 5, 6, 7 -EW - Employee Work Area D - Minor Code Deviation 2 - Program Areas (28 CFR 36.304(c)(2)) 279 Admin. - Office 11.23A - Mounting Location (Visual/Tactile Signs) Sign is not mounted on the wall adjacent to the latch side of the door. OR At double leaf doors, the sign is not placed on the nearest adjacent wall. 4.30.6 703.4.2 1117B.5 .7 -EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 280 Admin. - Office Page 25 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.17B - Room/Space Identification Signs (Visual/Tactile Signs) Sign designating the permanent room or space does not comply with ADAAG and CBC requirements for tactile signs. 4.1.2(7) ; 4.30.1, 4, 5, 6 216.2; 703.1; 703.2; 703.5 1117B.5 .2, 3, 5, 6, 7 -EW - Employee Work Area D - Minor Code Deviation 2 - Program Areas (28 CFR 36.304(c)(2)) 283 Admin. - Office 11.23A - Mounting Location (Visual/Tactile Signs) Sign is not mounted on the wall adjacent to the latch side of the door. OR At double leaf doors, the sign is not placed on the nearest adjacent wall. 4.30.6 703.4.2 1117B.5 .7 -EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 284 Admin. - Office 11.17B - Room/Space Identification Signs (Visual/Tactile Signs) Sign designating the permanent room or space does not comply with ADAAG and CBC requirements for tactile signs. 4.1.2(7) ; 4.30.1, 4, 5, 6 216.2; 703.1; 703.2; 703.5 1117B.5 .2, 3, 5, 6, 7 -EW - Employee Work Area D - Minor Code Deviation 2 - Program Areas (28 CFR 36.304(c)(2)) 287 Admin. - Office 11.23A - Mounting Location (Visual/Tactile Signs) Sign is not mounted on the wall adjacent to the latch side of the door. OR At double leaf doors, the sign is not placed on the nearest adjacent wall. 4.30.6 703.4.2 1117B.5 .7 -EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 288 Admin. - Office 11.17B - Room/Space Identification Signs (Visual/Tactile Signs) Sign designating the permanent room or space does not comply with ADAAG and CBC requirements for tactile signs. 4.1.2(7) ; 4.30.1, 4, 5, 6 216.2; 703.1; 703.2; 703.5 1117B.5 .2, 3, 5, 6, 7 -EW - Employee Work Area D - Minor Code Deviation 2 - Program Areas (28 CFR 36.304(c)(2)) 291 Admin. - Office Page 26 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.23A - Mounting Location (Visual/Tactile Signs) Sign is not mounted on the wall adjacent to the latch side of the door. OR At double leaf doors, the sign is not placed on the nearest adjacent wall. 4.30.6 703.4.2 1117B.5 .7 -EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 292 Admin. - Office 11.17B - Room/Space Identification Signs (Visual/Tactile Signs) Sign designating the permanent room or space does not comply with ADAAG and CBC requirements for tactile signs. 4.1.2(7) ; 4.30.1, 4, 5, 6 216.2; 703.1; 703.2; 703.5 1117B.5 .2, 3, 5, 6, 7 -EW - Employee Work Area D - Minor Code Deviation 2 - Program Areas (28 CFR 36.304(c)(2)) 295 Admin. - Office 11.23A - Mounting Location (Visual/Tactile Signs) Sign is not mounted on the wall adjacent to the latch side of the door. OR At double leaf doors, the sign is not placed on the nearest adjacent wall. 4.30.6 703.4.2 1117B.5 .7 -EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 296 Admin. - Office 11.15A - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -Door stop EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 299 Admin. - Office 11.17B - Room/Space Identification Signs (Visual/Tactile Signs) Sign designating the permanent room or space does not comply with ADAAG and CBC requirements for tactile signs. 4.1.2(7) ; 4.30.1, 4, 5, 6 216.2; 703.1; 703.2; 703.5 1117B.5 .2, 3, 5, 6, 7 -EW - Employee Work Area D - Minor Code Deviation 2 - Program Areas (28 CFR 36.304(c)(2)) 300 Admin. - Office Page 27 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.23A - Mounting Location (Visual/Tactile Signs) Sign is not mounted on the wall adjacent to the latch side of the door. OR At double leaf doors, the sign is not placed on the nearest adjacent wall. 4.30.6 703.4.2 1117B.5 .7 -EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 301 Admin. - Office 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 304 Admin. - Office 11.17B - Room/Space Identification Signs (Visual/Tactile Signs) Sign designating the permanent room or space does not comply with ADAAG and CBC requirements for tactile signs. 4.1.2(7) ; 4.30.1, 4, 5, 6 216.2; 703.1; 703.2; 703.5 1117B.5 .2, 3, 5, 6, 7 -EW - Employee Work Area D - Minor Code Deviation 2 - Program Areas (28 CFR 36.304(c)(2)) 305 Admin. - Office 11.23A - Mounting Location (Visual/Tactile Signs) Sign is not mounted on the wall adjacent to the latch side of the door. OR At double leaf doors, the sign is not placed on the nearest adjacent wall. 4.30.6 703.4.2 1117B.5 .7 -EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 306 Admin. - Office 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 309 Admin. - Office Page 28 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.17B - Room/Space Identification Signs (Visual/Tactile Signs) Sign designating the permanent room or space does not comply with ADAAG and CBC requirements for tactile signs. 4.1.2(7) ; 4.30.1, 4, 5, 6 216.2; 703.1; 703.2; 703.5 1117B.5 .2, 3, 5, 6, 7 -EW - Employee Work Area D - Minor Code Deviation 2 - Program Areas (28 CFR 36.304(c)(2)) 310 Admin. - Office 11.23A - Mounting Location (Visual/Tactile Signs) Sign is not mounted on the wall adjacent to the latch side of the door. OR At double leaf doors, the sign is not placed on the nearest adjacent wall. 4.30.6 703.4.2 1117B.5 .7 -EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 311 Admin. - Office 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -4" push side EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 314 Admin. - Conf. 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 315 Admin. - Conf. Page 29 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.13B - Hardware Operating Effort The force required to activate handles, pulls, latches, locks, and other operable parts of door exceeds 5 lbs. 4.27.4 309.4 1117B.6 item 4 -EW - Employee Work Area B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 316 Admin. - Conf. 11.14 - Closers Door closer is not adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3” from the latch (measured to the leading edge of the door). 4.13.10 404.2.8. 1 1133B.2 .5.1 -EW - Employee Work Area B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 317 Admin. - Conf. 11.15A - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 318 Admin. - Conf. 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -MS - Maintenance and Storage Only C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 320 Admin. - Conf. 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -MS - Maintenance and Storage Only C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 324 Admin. - Conf. Page 30 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.13A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -7 lb.GS - General Student Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 328 Admin. - East Stairwell 11.15A - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -Door stop GS - General Student Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 329 Admin. - East Stairwell 11.15B_04AG - Vision Lights Door, gate, or adjacent sidelight, containing one or more vision lights, does not include at least one vision light mounted with the bottom edge of the glazed panel at 43" max.. AFF. (Exception: Vision lights with the lowest part more than 66" AFF.) -404.2.1 1 --59 3/4" high GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 330 Admin. - East Stairwell 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -GS - General Student Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 331 Admin - East Stairwell 11.20A - Exit Enclosure / Passageway - Required Exit Route Sign At exit access door that leads to a grade-level exterior exit by means of an exit enclosure that does not utilize a stair or ramp, or by means of an exit passageway, there is no tactile and CA Braille exit sign with the words “EXIT ROUTE” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 3 -GS - General Student Use D - Minor Code Deviation 2 - Program Areas (28 CFR 36.304(c)(2)) 332 Admin. - East Stairwell Page 31 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -MS - Maintenance and Storage Only C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 335 Admin. - East Stairwell 11.13A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -GS - General Student Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 339 Admin. - East exit doors 11.14 - Closers Door closer is not adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3” from the latch (measured to the leading edge of the door). 4.13.10 404.2.8. 1 1133B.2 .5.1 -2.5 secs.GS - General Student Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 340 Admin. - East exit doors 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -MS - Maintenance and Storage Only C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 344 Admin. - East Stairwell 11.13A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -12 LBF.EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 354 Admin. - Hallway Page 32 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.21A - Required Exit Route Sign At exit access door from an interior room or area that is required to have a visual exit sign, there is no tactile and CA Braille exit sign with the words “EXIT ROUTE” mounted on the wall adjacent to the latch side of the door. (Visual exit signs are required when two or more exits are required. Generally, all occupants shall have access to two exits from a floor (CBC Table 1019.1). Exceptions: a) Single story building with maximum occupant load of 49 and less than 75 ft travel distance to exit (CBC Table 1019.2), and b) Two story building with maximum occupant load of 30 occupants per floor and maximum travel distance of 75 ft to exit. (CBC Table 1019.2). Two exit access doors are required from an office tenant space when the occupant load exceeds 49.) 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 4 -EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 355 Admin. - Hallway 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Twist-type locking mechanism.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 356 Admin. - Hallway Page 33 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -42 1/2" landing at push side, 51 1/2" landing at pull side. EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 359 Admin. - Stairwell 11.13A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -6 LBF.EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 360 Admin. - Stairwell 11.12 - Hardware Mounting Height Mounting height of all operating hardware is not 30” min.. or 44” max.., as measured to the highest operable part. (1994 ADA Standards permit a max.. height of 48"; CBC Standards permit a range of 30” min.. to 44” max..) 4.13.9 -1133B.2 .5.2 -Key pad at 47 3/4" AFF.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 361 Admin. - Stairwell 11.17B - Room/Space Identification Signs (Visual/Tactile Signs) Sign designating the permanent room or space does not comply with ADAAG and CBC requirements for tactile signs. 4.1.2(7) ; 4.30.1, 4, 5, 6 216.2; 703.1; 703.2; 703.5 1117B.5 .2, 3, 5, 6, 7 -PV - Public/Visitor Use D - Minor Code Deviation 2 - Program Areas (28 CFR 36.304(c)(2)) 373 Admin. - Office Page 34 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.23A - Mounting Location (Visual/Tactile Signs) Sign is not mounted on the wall adjacent to the latch side of the door. OR At double leaf doors, the sign is not placed on the nearest adjacent wall. 4.30.6 703.4.2 1117B.5 .7 -On door.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 374 Admin. - Office 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Door knob.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 375 Admin. - Office 11.15A - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -Door stop.EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 411 Admin. - Women's Restroom 11.30 - Other - Doors and Gates See Additional Comments ----Door knob.EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 425 Admin. - Storage 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -EC - Employee Common Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 426 Admin. - Storage Page 35 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -14" to non-fixed shelving, pull side. EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 428 Admin. - Storage 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -9 3/4" pull side MS - Maintenance and Storage Only C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 429 Admin. - Storage Page 36 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -6" at push side EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 452 Admin. - Hallway 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Lock on lever.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 453 Admin. - Hallway 11.13A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -9 Lb EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 454 Admin. - Hallway 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 456 Admin. - Office Page 37 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.17B - Room/Space Identification Signs (Visual/Tactile Signs) Sign designating the permanent room or space does not comply with ADAAG and CBC requirements for tactile signs. 4.1.2(7) ; 4.30.1, 4, 5, 6 216.2; 703.1; 703.2; 703.5 1117B.5 .2, 3, 5, 6, 7 -EW - Employee Work Area D - Minor Code Deviation 2 - Program Areas (28 CFR 36.304(c)(2)) 457 Admin. - Office 11.23A - Mounting Location (Visual/Tactile Signs) Sign is not mounted on the wall adjacent to the latch side of the door. OR At double leaf doors, the sign is not placed on the nearest adjacent wall. 4.30.6 703.4.2 1117B.5 .7 -EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 458 Admin. - Office 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -5" pull side, pipes EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 462 Admin. - S. Stairwell 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -knob EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 463 Admin. - S. Stairwell Page 38 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.13A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -6 Lb EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 464 Admin. - S. Stairwell 11.14 - Closers Door closer is not adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3” from the latch (measured to the leading edge of the door). 4.13.10 404.2.8. 1 1133B.2 .5.1 -2 sec.EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 465 Admin. - S. Stairwell 11.15A - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 466 Admin. - S. Stairwell 11.15B_04AG - Vision Lights Door, gate, or adjacent sidelight, containing one or more vision lights, does not include at least one vision light mounted with the bottom edge of the glazed panel at 43" max.. AFF. (Exception: Vision lights with the lowest part more than 66" AFF.) -404.2.1 1 --59" high EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 467 Admin. - S. Stairwell 11.10B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -3/4" high EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 469 Admin. - S. Stairwell 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -MS - Maintenance and Storage Only C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 470 Admin. - Private Rm. Page 39 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.14 - Closers Door closer is not adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3” from the latch (measured to the leading edge of the door). 4.13.10 404.2.8. 1 1133B.2 .5.1 -2.4 sec.EC - Employee Common Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 479 Admin. - S. Stairwell Exit Doors 11.12 - Hardware Mounting Height Mounting height of all operating hardware is not 30” min.. or 44” max.., as measured to the highest operable part. (1994 ADA Standards permit a max.. height of 48"; CBC Standards permit a range of 30” min.. to 44” max..) 4.13.9 -1133B.2 .5.2 -47" high push pad EC - Employee Common Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 480 Admin. - S. Stairwell Exit Doors 11.15A - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 490 Admin. Conference Rm. 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -EC - Employee Common Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 494 Admin. Conference Rm. 11.17B - Room/Space Identification Signs (Visual/Tactile Signs) Sign designating the permanent room or space does not comply with ADAAG and CBC requirements for tactile signs. 4.1.2(7) ; 4.30.1, 4, 5, 6 216.2; 703.1; 703.2; 703.5 1117B.5 .2, 3, 5, 6, 7 -EW - Employee Work Area D - Minor Code Deviation 2 - Program Areas (28 CFR 36.304(c)(2)) 498 Admin. Office 11.23A - Mounting Location (Visual/Tactile Signs) Sign is not mounted on the wall adjacent to the latch side of the door. OR At double leaf doors, the sign is not placed on the nearest adjacent wall. 4.30.6 703.4.2 1117B.5 .7 -EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 499 Admin. Office Page 40 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -knob EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 500 Admin. Office 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Twist-type locking mechanism.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 511 Admin. - Conference Room 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -48" to large conference table at pull side. EC - Employee Common Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 515 Admin. - Conference Room Page 41 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -10" maneuvering space, guard rail. PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 520 Admin. - Elevator Platform 11.13A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -10 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 521 Admin. - Elevator Platform 11.14 - Closers Door closer is not adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3” from the latch (measured to the leading edge of the door). 4.13.10 404.2.8. 1 1133B.2 .5.1 -1.8 second closer.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 522 Admin. - Elevator Platform 11.09 - Door Swings - Doors in Series Doors in a series do not swing in the same direction. OR The doors do not swing away from each other. (2004 ADAAG permits doors to swing towards each other when the clear space between doors is at least 48” plus the width of both doors swinging into the space.) 4.13.7; Fig. 26 404.2.6 Fig. 404.2.6 1133B.2 .4.4 -22 1/2" between doors opening toward one another. PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 524 Admin. - Elevator Platform Page 42 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Door knob.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 529 Admin. - Open Office 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 539 Admin. - Office 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 543 Admin. - Office 11.15A - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -Door stop.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 559 Admin. - Men's Restroom 11.15A - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -Door stop.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 576 Admin. - Women's Restroom Page 43 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Door knob and lock.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 581 Admin. - Storage Room 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -11 1/2" push side, wall.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 582 Admin. - Stairwell 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Door knob.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 583 Admin. - Stairwell 11.15A - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -Door stop.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 584 Admin. - Stairwell Page 44 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.15B_04AG - Vision Lights Door, gate, or adjacent sidelight, containing one or more vision lights, does not include at least one vision light mounted with the bottom edge of the glazed panel at 43" max.. AFF. (Exception: Vision lights with the lowest part more than 66" AFF.) -404.2.1 1 --61" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 585 Admin. - Stairwell 11.13A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -6 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 586 Admin. - Stairwell 11.14 - Closers Door closer is not adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3” from the latch (measured to the leading edge of the door). 4.13.10 404.2.8. 1 1133B.2 .5.1 -2.5 second closer.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 587 Admin. - Stairwell 11.19A - Required Exit Stairway Sign At exit door, identified with an illuminated EXIT sign, leading to an exit stairway, there is no tactile and CA Braille exit sign with the words “EXIT STAIRS UP/DOWN” mounted on the wall adjacent to the latch side of the stairway door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 2 -PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 588 Admin. - Stairwell 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -5" at push and pull side.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 590 Admin. - Hallway Page 45 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.13A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -6 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 591 Admin. - Hallway 11.12 - Hardware Mounting Height Mounting height of all operating hardware is not 30” min.. or 44” max.., as measured to the highest operable part. (1994 ADA Standards permit a max.. height of 48"; CBC Standards permit a range of 30” min.. to 44” max..) 4.13.9 -1133B.2 .5.2 -Keypad at 46" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 592 Admin. - Hallway 11.13B - Hardware Operating Effort The force required to activate handles, pulls, latches, locks, and other operable parts of door exceeds 5 lbs. 4.27.4 309.4 1117B.6 item 4 -7 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 593 Admin. - Hallway 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 602 Admin. - Conference Room 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 607 Admin. - Office 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Door knob.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 613 Admin. - Office Page 46 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.17B - Room/Space Identification Signs (Visual/Tactile Signs) Sign designating the permanent room or space does not comply with ADAAG and CBC requirements for tactile signs. 4.1.2(7) ; 4.30.1, 4, 5, 6 216.2; 703.1; 703.2; 703.5 1117B.5 .2, 3, 5, 6, 7 -PV - Public/Visitor Use D - Minor Code Deviation 2 - Program Areas (28 CFR 36.304(c)(2)) 614 Admin. - Office 11.23A - Mounting Location (Visual/Tactile Signs) Sign is not mounted on the wall adjacent to the latch side of the door. OR At double leaf doors, the sign is not placed on the nearest adjacent wall. 4.30.6 703.4.2 1117B.5 .7 -Mounted on door.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 615 Admin. - Office 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Door knob and twist-type locking mechanism. EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 623 Admin. - Office 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 624 Admin. - Office 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 626 Admin. - Office Page 47 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -2 1/2" pull side, non-fixed furniture. EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 628 Admin. - Office 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 630 Admin. - Office 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -12" pull side, wall.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 633 Admin. - Office Page 48 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Twist-type locking mechanism.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 638 Admin. - Office 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 639 Admin. - Office 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -EC - Employee Common Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 644 Admin. - Supply Room 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -40" deep landing at pull side, non-fixed furniture. EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 646 Admin. - Supply Room Page 49 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -2 1/2" pull side, non-fixed furniture. EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 651 Admin. - Office 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Thumb latch.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 654 Admin. - Stairwell 11.15A - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -Door stop.EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 655 Admin. - Stairwell 11.13A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -10 LBF.EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 656 Admin. - Stairwell Page 50 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.13B - Hardware Operating Effort The force required to activate handles, pulls, latches, locks, and other operable parts of door exceeds 5 lbs. 4.27.4 309.4 1117B.6 item 4 -7 LBF.EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 657 Admin. - Stairwell 11.10B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -Change in elevation between 1/2" & 3/4" AFF. EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 659 Admin. - Stairwell 11.19A - Required Exit Stairway Sign At exit door, identified with an illuminated EXIT sign, leading to an exit stairway, there is no tactile and CA Braille exit sign with the words “EXIT STAIRS UP/DOWN” mounted on the wall adjacent to the latch side of the stairway door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 2 -EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 660 Admin. - Stairwell 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Door knob.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 661 Admin. - Hallway 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 664 Admin. - Office Page 51 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -Non-fixed furniture encroaches door maneuvering space. PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 665 Admin. - Office 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Twist-type lock.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 668 Admin. - Office 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Accessible hardware not provided. EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 677 Admin. - Office 11.15A - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -Door stop.EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 704 Admin. - Unisex Restroom Page 52 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.15A - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -Vent at 4 1/2" AFF.EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 706 Admin. - Server Room 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 707 Admin. - Office 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Twist-type locking mechanism.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 708 Admin. - Office 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -7" to non-fixed furniture, pull side. EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 710 Admin. - Office Page 53 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 714 Admin. - Office 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Twist-type locking mechanism.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 716 Admin. - Office 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -11" to non-fixed furniture, pull side. EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 717 Admin. - Office 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Twist-type locking mechanism.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 726 Admin. - Office Page 54 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.15A - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -Door stop.EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 727 Admin. - Office 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 728 Admin. - Office 11.15A - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -Door stop.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 734 Admin. - Stairwell 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -10" to wall, push side.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 735 Admin. - Stairwell Page 55 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.13A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -12 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 737 Admin. - Stairwell 11.15B_04AG - Vision Lights Door, gate, or adjacent sidelight, containing one or more vision lights, does not include at least one vision light mounted with the bottom edge of the glazed panel at 43" max.. AFF. (Exception: Vision lights with the lowest part more than 66" AFF.) -404.2.1 1 --59 3/4" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 738 Admin. - Stairwell 11.19A - Required Exit Stairway Sign At exit door, identified with an illuminated EXIT sign, leading to an exit stairway, there is no tactile and CA Braille exit sign with the words “EXIT STAIRS UP/DOWN” mounted on the wall adjacent to the latch side of the stairway door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 2 -PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 739 Admin. - Stairwell 11.10B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -3/4" change in level.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 740 Admin. - Stairwell 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Twist-type locking mechanism.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 742 Admin. - Office 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 743 Admin. - Office Page 56 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 199Number of Key Notes for Group 11 - Doors and Gates: Group 18 - Dressing, Fitting and Locker Rooms Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 18.05B - Fixed Bench Size Fixed bench is not 24" wide and 48" long.4.35.4 903.3 1117B.8 -15"x37" bench EC - Employee Common Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 450 Admin. - Unisex Restrm. 1Number of Key Notes for Group 18 - Dressing, Fitting and Locker Rooms: Group 13 - Elevators Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 13.04A - Call Buttons - Mounting Height The hallway call buttons are not centered at 42” above the floor. 4.10.3 308; 407.2.1. 1 1116B.1 .10 -42 1/4" high at 1st flr. & 41 1/2" at 2nd flr. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 267 Admin. - Elevator 13.05B - Call Buttons - Internal Illumination The hall call buttons are not internally illuminated with a white light over the entire surface of the button. --1116B.1 .10 -illuminated w/ red light PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 268 Admin. - Elevator 13.08 - Visible Hall Signals Visible signals are not provided. OR They are provided, however they are: mounted so that the centerline is less than 72” AFF; less than 2- 1/2” in the smallest dimension; or, not visible from the vicinity of the hall call button. 4.10.4(1 )(2) 407.2.2. 2 1116B.1 .13; Fig. 11B-40C -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 269 Admin. - Elevator Page 57 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 13 - Elevators Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 13.10 - Door Jamb Signs - Braille California Grade 2 Braille is not placed below the corresponding raised characters or symbols. 4.30.4 703.3 1116B.1 .14; 1117B.5 .6 -Braille space to wide at 1st & 2nd floor PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 270 Admin. - Elevator 13.16A - Handrail There is no handrail installed at 32” AFF (+/-1”). --1116B.1 .11 -31" AFF.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 271 Admin. - Elevator 5Number of Key Notes for Group 13 - Elevators: Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.02 - Entrance Sign Accessible entrance is not identified by an ISA.28 CFR 35.163( b)1 216.6 1117B.5 .8.1.2 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 1 Ch. 33 - Office 10.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab.404 .2.4.1; Fig.404. 2.4.1 1133B.2 .4.2; Fig. 11B-26 -4" non-fixed desk, pull side.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 2 Ch. 33 - Office Page 58 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.09A - > 1/4" Changes in Level - Threshold Where threshold is 1/4" min.. to 1/2" max.. in height, change in level is not beveled at 1:2 or less. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 3 Ch. 33 - Office 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 4 Ch. 33 - Office 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 26 Ch. 33 - Back Door 10.11B - Hardware Operating Effort The force required to activate handles, pulls, latches, locks, and other operable parts of door exceeds 5 lbs. 4.27.4 309.4 1117B.6 item 4 -10 & 16 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 27 Ch. 33 - Back Door 10.08 - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -Panic rods obstruct kick plate area. PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 28 Ch. 33 - Back Door 10.05 - Clear Door Opening When the door is open 90 degrees, clear opening width is not at least 32” measured between the face of the door and the doorstop on the latch side. 4.13.5 404.2.3; Fig. 404.2.3 1133B.1 .1.1.1; 1133B.2 .2 -28" clear opening.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 68 Ch. 33 - Storage Page 59 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.08 - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -Door stops and latch at kick plate area. PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 69 Ch. 33 - Storage 10.09B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -1" change in level.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 70 Ch. 33 - Storage 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 73 Comm. Dev. - Entrance 10.16 - Other - Building Entrances and Exits See Additional Comments ----Motorized door actuator not functioning. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 74 Comm. Dev. - Vestibule 10.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -6 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 75 Comm. Dev. - Vestibule 10.11B - Hardware Operating Effort The force required to activate handles, pulls, latches, locks, and other operable parts of door exceeds 5 lbs. 4.27.4 309.4 1117B.6 item 4 -15 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 76 Comm. Dev. - Vestibule Page 60 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.08 - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -Door stop.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 77 Comm. Dev. - Vestibule 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -EC - Employee Common Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 195 Comm. Dev. - Back Door 10.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -7 LBF.EC - Employee Common Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 196 Comm. Dev. - Back Door 10.11B - Hardware Operating Effort The force required to activate handles, pulls, latches, locks, and other operable parts of door exceeds 5 lbs. 4.27.4 309.4 1117B.6 item 4 -11 LBF.EC - Employee Common Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 198 Comm. Dev. - Back Door 10.08 - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -Door stop.EC - Employee Common Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 199 Comm. Dev. - Back Door 10.02 - Entrance Sign Accessible entrance is not identified by an ISA.28 CFR 35.163( b)1 216.6 1117B.5 .8.1.2 -EC - Employee Common Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 200 Comm. Dev. - Back Door Page 61 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -EC - Employee Common Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 229 Comm. Dev. - Conference Rm 10.02 - Entrance Sign Accessible entrance is not identified by an ISA.28 CFR 35.163( b)1 216.6 1117B.5 .8.1.2 -EC - Employee Common Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 230 Comm. Dev. - Conference Rm 10.11B - Hardware Operating Effort The force required to activate handles, pulls, latches, locks, and other operable parts of door exceeds 5 lbs. 4.27.4 309.4 1117B.6 item 4 -16 LBF.EC - Employee Common Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 231 Comm. Dev. - Conference Rm 10.05 - Clear Door Opening When the door is open 90 degrees, clear opening width is not at least 32” measured between the face of the door and the doorstop on the latch side. 4.13.5 404.2.3; Fig. 404.2.3 1133B.1 .1.1.1; 1133B.2 .2 -28" clear.EC - Employee Common Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 232 Comm. Dev. - Conference Rm 10.08 - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -Door stop.EC - Employee Common Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 233 Comm. Dev. - Conference Rm 10.08 - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -Latch.EC - Employee Common Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 236 Comm. Dev. - Conference Rm Page 62 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.02 - Entrance Sign Accessible entrance is not identified by an ISA.28 CFR 35.163( b)1 216.6 1117B.5 .8.1.2 -EC - Employee Common Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 250 Comm. Dev. - Copy Rm 10.05 - Clear Door Opening When the door is open 90 degrees, clear opening width is not at least 32” measured between the face of the door and the doorstop on the latch side. 4.13.5 404.2.3; Fig. 404.2.3 1133B.1 .1.1.1; 1133B.2 .2 -28" clear.EC - Employee Common Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 251 Comm. Dev. - Copy Rm 10.08 - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -Door stop.EC - Employee Common Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 253 Comm. Dev. - Copy Rm 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Thumb latch.EC - Employee Common Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 255 Comm. Dev. - Copy Rm 10.11B - Hardware Operating Effort The force required to activate handles, pulls, latches, locks, and other operable parts of door exceeds 5 lbs. 4.27.4 309.4 1117B.6 item 4 -6 LBF.EC - Employee Common Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 256 Comm. Dev. - Copy Rm 10.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -9 LBF.EC - Employee Common Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 257 Comm. Dev. - Copy Rm Page 63 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -EC - Employee Common Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 258 Comm. Dev. - Copy Rm 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Pinching latch lock.EC - Employee Common Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 260 Comm. Dev. - Copy Rm 10.02 - Entrance Sign Accessible entrance is not identified by an ISA.28 CFR 35.163( b)1 216.6 1117B.5 .8.1.2 -GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 336 Admin. - East exit doors 10.07A - Landing - Level and Clear Floor is not level (slope is greater than 2% in some or all directions). OR Floor is not clear within the required maneuvering space. 4.13.6; Fig. 25 305; 404.2.4. 4 1133B.2 .4 -3.0% @ threshold & 2.7% at landing GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 337 Admin. - East exit doors 10.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -10 lbs.GS - General Student Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 338 Admin. - East exit doors 10.02 - Entrance Sign Accessible entrance is not identified by an ISA.28 CFR 35.163( b)1 216.6 1117B.5 .8.1.2 -EC - Employee Common Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 473 Admin. - S. Stairwell Exit Doors Page 64 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.09B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -1 1/2" high EC - Employee Common Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 475 Admin. - S. Stairwell Exit Doors 10.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -8 Lb. x2 EC - Employee Common Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 476 Admin. - S. Stairwell Exit Doors 10.11B - Hardware Operating Effort The force required to activate handles, pulls, latches, locks, and other operable parts of door exceeds 5 lbs. 4.27.4 309.4 1117B.6 item 4 -8 Lb. x 2 EC - Employee Common Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 477 Admin. - S. Stairwell Exit Doors 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -EC - Employee Common Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 478 Admin. - S. Stairwell Exit Doors 42Number of Key Notes for Group 10 - Entrances and Exits: Group 12A - Interior Accessible Route Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 12A.03 - U-Turn Where the accessible route of travel makes a U- turn around an obstacle which is less than 48” wide, the pathway width does not increase to at least 42” on the approaches or 48” in the turn. Fig. 7(b) 403.5.2; Fig. 403.5.2 (a) Fig 11B- 5E -Non-fixed furniture does not provide adequate "U-Turn" space. EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 161 Comm. Dev. - Cashier 1Number of Key Notes for Group 12A - Interior Accessible Route: Page 65 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 77 3/4" AFF.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 7 Ch. 33 - Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Coat hook at 72" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 8 Ch. 33 - Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Security alarm at 57 1/4" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 9 Ch. 33 - Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -3 power outlets and 1 data port at 12" AFF. PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 10 Ch. 33 - Office 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Floor mat.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 11 Ch. 33 - Office Page 66 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 79 1/2" AFF.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 12 Ch. 33 - Back Room 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Mat.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 13 Ch. 33 - Back Room 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -3 power outlets and 1 data port at 11" AFF. PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 14 Ch. 33 - Back Room 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Coat hook at 69" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 15 Ch. 33 - Back Room 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 79 1/2" AFF.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 19 Ch. 33 - Sound Stage Page 67 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Thermostat at 62 1/2" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 20 Ch. 33 - Sound Stage 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Floor mat.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 21 Ch. 33 - Sound Stage 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -Twist-type thermostat.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 25 Ch. 33 - Back Door 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 79 7/8" AFF.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 30 Ch. 33 - Storage 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 79 1/4" AFF.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 33 Ch. 33 - Control Room 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -6 power outlets at 6" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 35 Ch. 33 - Control Room Page 68 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.21B - 36" Width Standard The accessible route of travel is not at least 36” wide where the occupancy load is < 10. (For a depth of 24" max.., clear opening width may be reduced to 32" min..) (Doorways are compliant when the door, open 90 degrees, affords a clear opening width of at least 32”.) 4.3.3; Fig. 7(a)(b) 403.5.1; Fig. 403.5.1 1133B.3 .1 -24" clearance due to non-fixed furniture. PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 36 Ch. 33 - Control Room 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -2 shelves at 57" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 37 Ch. 33 - Control Room 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Observation window sill at 46 1/2" AFF. PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 38 Ch. 33 - Control Room 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Coat hook at 63" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 42 Ch. 33 - Control Room 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 79 3/4" AFF.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 43 Ch. 33 - Control Room Page 69 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 77" AFF & Closer at 71" AFF. PV - Public/Visitor Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 47 Ch. 33 - Restroom 14.30A - Wall- Mounted Protruding Objects Wall-mounted object(s) with leading edges between 27 and 80” from the floor project more than 4" into the pathway. (Wall mounted objects with leading edges at or below 27” may project any amount as long as the required clear width of an accessible route is not reduced.) 4.4.1 307.2; Fig. 307.2 1133B.8 .6.1 -PTD protrudes 10" at 45" AFF.PV - Public/Visitor Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 58 Ch. 33 - Restroom 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 78 1/2" AFF.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 71 Ch. 33 - Storage 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Unsecured floor mat.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 72 Comm. Dev. - Entrance 14.30A - Wall- Mounted Protruding Objects Wall-mounted object(s) with leading edges between 27 and 80” from the floor project more than 4" into the pathway. (Wall mounted objects with leading edges at or below 27” may project any amount as long as the required clear width of an accessible route is not reduced.) 4.4.1 307.2; Fig. 307.2 1133B.8 .6.1 -Feminine napkin dispenser protrudes 6 3/4" at 29 3/4" AFF. PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 138 Comm. Dev. - Women's Staff Restroom 14.29C - Counter - Knee Space Depth Where seating for persons in wheelchairs is provided at table or counter, knee space is less than 19" deep. 4.32.3 306.3.2; Fig. 306.3 1122B.3 ; Fig. 11B-13 -3/4" knee depth at employee side. PV - Public/Visitor Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 141 Comm. Dev. - Planning Dept. Counter Page 70 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Security pad at 59 1/2" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 142 Comm. Dev. - Lobby 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 76 3/4" AFF.EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 146 Comm. Dev. - Office 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Floor mats.EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 148 Comm. Dev. - Office 14.29A - Counter - Knee Space Height Where seating for persons in wheelchairs is provided at table or counter, knee space is less than 27” high. 4.32.3 306.3.1; Fig. 306.3 1122B.3 ; Fig. 11B-13 -41 3/4" to top of counter at computer stations. EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 152 Comm. Dev. - Computer Station 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Floor mat.EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 153 Comm. Dev. - Computer Station 14.29C - Counter - Knee Space Depth Where seating for persons in wheelchairs is provided at table or counter, knee space is less than 19" deep. 4.32.3 306.3.2; Fig. 306.3 1122B.3 ; Fig. 11B-13 -1/2" knee depth at employee side. EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 154 Comm. Dev. - Open Office Page 71 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.21B - 36" Width Standard The accessible route of travel is not at least 36” wide where the occupancy load is < 10. (For a depth of 24" max.., clear opening width may be reduced to 32" min..) (Doorways are compliant when the door, open 90 degrees, affords a clear opening width of at least 32”.) 4.3.3; Fig. 7(a)(b) 403.5.1; Fig. 403.5.1 1133B.3 .1 -35 1/2" non-fixed furniture.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 155 Comm. Dev. - Open Office 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Floor mat.EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 156 Comm. Dev. - Open Office 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Floor mat.EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 163 Comm. Dev. - Open Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Key lockbox at 58" AFF.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 164 Comm. Dev. - Hallway 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Floor mat.EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 168 Comm. Dev. - Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Power outlets at less than 15" AFF. EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 170 Comm. Dev. - Office Page 72 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 79 3/4" AFF.EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 172 Comm. Dev. - Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Coat hook at 67" AFF.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 174 Comm. Dev. - Office 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Floor mat.EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 176 Comm. Dev. - Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -4 power outlets and 1 data port between 12" & 14" AFF. EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 177 Comm. Dev. - Office 14.30A - Wall- Mounted Protruding Objects Wall-mounted object(s) with leading edges between 27 and 80” from the floor project more than 4" into the pathway. (Wall mounted objects with leading edges at or below 27” may project any amount as long as the required clear width of an accessible route is not reduced.) 4.4.1 307.2; Fig. 307.2 1133B.8 .6.1 -Shelf-type desk protrudes 13 1/2" at 28 3/4" AFF. EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 178 Comm. Dev. - Office Page 73 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.29A - Counter - Knee Space Height Where seating for persons in wheelchairs is provided at table or counter, knee space is less than 27” high. 4.32.3 306.3.1; Fig. 306.3 1122B.3 ; Fig. 11B-13 -Knee space at 26 3/4".EW - Employee Work Area B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 179 Comm. Dev. - Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Coat hook at 72" AFF.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 183 Comm. Dev. - Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Power outlet at 13 1/2" AFF.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 184 Comm. Dev. - Office 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Floor mat.EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 187 Comm. Dev. - Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Coat hook at 69 1/2" AFF.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 188 Comm. Dev. - Office Page 74 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Floor mat.EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 192 Comm. Dev. - Office 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 79 1/2" AFF.EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 193 Comm. Dev. - Office 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Floor mat.EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 197 Comm. Dev. - Back Door 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Light switch at 62" AFF.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 201 Comm. Dev. - Back Door 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 76 3/4" AFF.EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 203 Comm. Dev. - Office 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Floor mat.EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 209 Comm. Dev. - Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Coat hook at 75" AFF.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 211 Comm. Dev. - Office Page 75 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 77 1/4" AFF.EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 213 Comm. Dev. - Office 14.37 - Kitchen Sink Sink does not provide accessible knee clearance (i.e. at least 27” high, 30” wide, and 19” deep). 4.24.3 305; 306; 606.2 1115B.4 .7(2); 1122B.4 -EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 218 Comm. Dev. - Break Room 14.30A - Wall- Mounted Protruding Objects Wall-mounted object(s) with leading edges between 27 and 80” from the floor project more than 4" into the pathway. (Wall mounted objects with leading edges at or below 27” may project any amount as long as the required clear width of an accessible route is not reduced.) 4.4.1 307.2; Fig. 307.2 1133B.8 .6.1 -Fire extinguisher protrudes 4 3/4" at 39 1/4" AFF. EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 221 Comm. Dev. - Hallway 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 79" AFF.EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 225 Comm. Dev. - Office 14.21B - 36" Width Standard The accessible route of travel is not at least 36” wide where the occupancy load is < 10. (For a depth of 24" max.., clear opening width may be reduced to 32" min..) (Doorways are compliant when the door, open 90 degrees, affords a clear opening width of at least 32”.) 4.3.3; Fig. 7(a)(b) 403.5.1; Fig. 403.5.1 1133B.3 .1 -33" clear.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 227 Comm. Dev. - Office 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Floor mat.EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 228 Comm. Dev. - Office 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 79" AFF.EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 238 Comm. Dev. - Conference Rm Page 76 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.21A - 44" Width Standard The accessible route of travel is not at least 44” wide where the occupancy load is ≥ 10. (For a depth of 24" max.., clear opening width may be reduced to 32" min..) (Doorways are compliant when the door, open 90 degrees, affords a clear opening width of at least 32”.) 4.3.3; Fig. 7(a)(b) 403.5.1; Fig. 403.5.1 1133B.3 .1 -21" clear around conference table and chairs. EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 242 Comm. Dev. - Conference Rm 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 79 1/8" AFF.EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 243 Comm. Dev. - Copy Rm 14.28 - Fixed/Built-in Seating, Tables or Counters At fixed or built-in seating, tables, or counters in public or common employee areas, less than 5% of the provided seating spaces are wheelchair accessible and have a 30” by 48” clear space which overlaps an accessible route of travel. (Wheelchair accessible seating spaces are between 28" - 34" high and with knee space measuring at least 27" high, 30" wide, and 19" deep.) (These elements include study carrels and student laboratory stations.) 4.1.3(18 ); 4.32.1; 4.32.4 226.1; Advisory 226.1; 305; 306; 902.2 1122B.1 -42 1/2" to counter top, 0" knee space. EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 246 Comm. Dev. - Copy Rm 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -First aid kit at 73" AFF.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 247 Comm. Dev. - Copy Rm 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -77 1/2" at door EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 252 Admin. - Office Page 77 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -2 data, 1 power strip.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 254 Admin. - Office 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Floor mat.EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 262 Comm. Dev. - Copy Rm 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -2 floor mats PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 263 Admin. - Reception 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -2 twist type thermostat EW - Employee Work Area B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 264 Admin. - Reception 14.28 - Fixed/Built-in Seating, Tables or Counters At fixed or built-in seating, tables, or counters in public or common employee areas, less than 5% of the provided seating spaces are wheelchair accessible and have a 30” by 48” clear space which overlaps an accessible route of travel. (Wheelchair accessible seating spaces are between 28" - 34" high and with knee space measuring at least 27" high, 30" wide, and 19" deep.) (These elements include study carrels and student laboratory stations.) 4.1.3(18 ); 4.32.1; 4.32.4 226.1; Advisory 226.1; 305; 306; 902.2 1122B.1 -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 265 Admin. - Reception Page 78 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -68" high brochures.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 266 Admin. - Reception 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -78 1/2" at door MS - Maintenance and Storage Only A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 273 Admin. - Central Stairwell 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -Twist type thermostat EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 275 Admin. - Open Office 14.28 - Fixed/Built-in Seating, Tables or Counters At fixed or built-in seating, tables, or counters in public or common employee areas, less than 5% of the provided seating spaces are wheelchair accessible and have a 30” by 48” clear space which overlaps an accessible route of travel. (Wheelchair accessible seating spaces are between 28" - 34" high and with knee space measuring at least 27" high, 30" wide, and 19" deep.) (These elements include study carrels and student laboratory stations.) 4.1.3(18 ); 4.32.1; 4.32.4 226.1; Advisory 226.1; 305; 306; 902.2 1122B.1 -EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 276 Admin. - Open Office 14.29B - Counter - Knee Space Width Where seating for persons in wheelchairs is provided at table or counter, knee space is less than 30" wide. 4.32.3 306.3.5; Fig. 306.3 1122B.3 ; Fig. 11B-13 -20" wide EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 277 Admin. - Open Office Page 79 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -12" high outlets EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 278 Admin. - Open Office 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 281 Admin. - Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 282 Admin. - Office 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 285 Admin. - Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 286 Admin. - Office Page 80 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 289 Admin. - Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 290 Admin. - Office 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 293 Admin. - Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 294 Admin. - Office 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 297 Admin. - Office Page 81 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -3 outlets.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 298 Admin. - Office 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 302 Admin. - Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -3 outlets EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 303 Admin. - Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -3 outlet & 3 Data, 1 thermostat EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 307 Admin. - Office 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 308 Admin. - Office Page 82 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -3 outlet & 3 data EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 312 Admin. - Office 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 313 Admin. - Office 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -79" high at door EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 319 Admin. - Conf. 14.30A - Wall- Mounted Protruding Objects Wall-mounted object(s) with leading edges between 27 and 80” from the floor project more than 4" into the pathway. (Wall mounted objects with leading edges at or below 27” may project any amount as long as the required clear width of an accessible route is not reduced.) 4.4.1 307.2; Fig. 307.2 1133B.8 .6.1 -16" deep at 31" high audio equipment EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 321 Admin. - Conf. 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -5 outlets, 4 data, 3 audio EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 322 Admin. - Conf. Page 83 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -twist type thermostat EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 323 Admin. - Conf. 14.30A - Wall- Mounted Protruding Objects Wall-mounted object(s) with leading edges between 27 and 80” from the floor project more than 4" into the pathway. (Wall mounted objects with leading edges at or below 27” may project any amount as long as the required clear width of an accessible route is not reduced.) 4.4.1 307.2; Fig. 307.2 1133B.8 .6.1 -4" at 53" high LCD screen GS - General Student Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 326 Admin. - Conf. 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 327 Admin. - Conf. 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -79" at door GS - General Student Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 333 Admin. - East Stairwell 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -78 1/2" at door MS - Maintenance and Storage Only A - Safety Hazard 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 334 Admin. - East Stairwell 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -2 floor mats GS - General Student Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 341 Admin. - East exit doors Page 84 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -78 1/2" at doors GS - General Student Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 342 Admin. - East exit doors 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -78 1/2" at door MS - Maintenance and Storage Only A - Safety Hazard 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 345 Admin - East Stairwell 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -First aid kit at 65" AFF & infection control kit at 78" AFF. EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 357 Admin. - Hallway 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Security pad at 61 1/2" AFF.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 358 Admin. - Hallway 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 78 3/4" AFF.EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 362 Admin. - Stairwell 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 77 1/2" AFF.EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 372 Admin. - Office Page 85 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -5 power outlets.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 376 Admin. - Office 14.30A - Wall- Mounted Protruding Objects Wall-mounted object(s) with leading edges between 27 and 80” from the floor project more than 4" into the pathway. (Wall mounted objects with leading edges at or below 27” may project any amount as long as the required clear width of an accessible route is not reduced.) 4.4.1 307.2; Fig. 307.2 1133B.8 .6.1 -P.T.D. protrudes 5"EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 393 Admin. - Men's Restroom 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 77 1/2" AFF.EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 395 Admin. - Men's Restroom 14.27 - > 1/2" Changes in Level Ramps or elevators are not used for changes in level greater than 1/2". (Lifts may only be used in certain limited situations.) 4.1.3(5) ; 4.5.2 303.4; 406 1124B.2 -3/4" change in level,EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 413 Admin. - Women's Restroom 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 77 1/2" AFF.EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 414 Admin. - Women's Restroom 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 420 Admin. - Hallway Page 86 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Floor mat.EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 421 Admin. - Hallway 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -4 power outlets at 13" AFF.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 423 Admin. - Hallway 14.02 - Accessible Route Accessible routes of travel do not connect the room or space to an accessible entrance within the building or facility. 4.1.3(1) ; 4.3.2(3) 206.2.4; Advisory 206.2.4 1114B.1 .2 -5 3/4" change in level.EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 424 Admin. - Storage 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 77 1/4" AFF.EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 427 Admin. - Storage 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -77 1/2" at door MS - Maintenance and Storage Only A - Safety Hazard 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 430 Admin. - Storage 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -2 mats EC - Employee Common Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 447 Admin. - Unisex Restrm. Page 87 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -53" high power switch EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 448 Admin. - Unisex Restrm. 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -77 1/2" at door EC - Employee Common Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 451 Admin. - Unisex Restrm. 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -77 1/2" at door EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 455 Admin. - Hallway 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 459 Admin. - Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -1 outlet, 1 power strip, & 57" high thermostat. EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 460 Admin. - Office 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -EW - Employee Work Area B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 461 Admin. - Office Page 88 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -77 1/2" high EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 468 Admin. - S. Stairwell 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -65 3/4" high Security Pad.EC - Employee Common Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 471 Admin. - S. Stairwell Exit Doors 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Floor Mat EC - Employee Common Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 472 Admin. - S. Stairwell Exit Doors 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -78 1/4" at door EC - Employee Common Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 474 Admin. - S. Stairwell Exit Doors 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Floor mat EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 491 Admin. Conference Rm. 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -4 outlets EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 492 Admin. Conference Rm. Page 89 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -77 1/2" at door EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 495 Admin. Conference Rm. 14.30A - Wall- Mounted Protruding Objects Wall-mounted object(s) with leading edges between 27 and 80” from the floor project more than 4" into the pathway. (Wall mounted objects with leading edges at or below 27” may project any amount as long as the required clear width of an accessible route is not reduced.) 4.4.1 307.2; Fig. 307.2 1133B.8 .6.1 -11 1/4" at 47 1/2" high Blueprint hanger EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 496 Admin. S. Corridor 14.33 - Electrical Switches The grip of the operating handle of electrical controls or switches intended to be used by occupants of the room or area is not centered at 48" above the floor or working platform. (This requirement applies to controls for lighting and receptacle outlets, appliances, and cooling, heating and ventilating equipment.) 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 308.2.1; Fig. 308.2.1; 308.3.1; Fig. 308.3.1; 309.3 1117B.6 (5.1) -Thermostat twist type.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 497 Admin. Office 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -3 floor mats EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 501 Admin. Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -3 outlets EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 502 Admin. Office Page 90 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -53" high panel EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 503 Admin. Office 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -77 1/2" at door EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 504 Admin. Receptionist 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 77 1/2" AFF.EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 505 Admin. - Hallway 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -2 outlets.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 506 Admin. S. Corridor 14.30A - Wall- Mounted Protruding Objects Wall-mounted object(s) with leading edges between 27 and 80” from the floor project more than 4" into the pathway. (Wall mounted objects with leading edges at or below 27” may project any amount as long as the required clear width of an accessible route is not reduced.) 4.4.1 307.2; Fig. 307.2 1133B.8 .6.1 -Shelf-type desk protrudes 31" at 29 1/2" AFF. EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 508 Admin. - Office Page 91 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -1 power outlet at 13 1/2" AFF.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 509 Admin. - Office 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 77 1/2" AFF.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 510 Admin. - Conference Room 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -1 power outlet, 2 data ports.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 512 Admin. - Conference Room 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -Twist-type thermostat.EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 513 Admin. - Conference Room 14.36A - Counter Height Where provided in public or common use areas, countertops are not between 28" - 34” high. (Common use areas are those interior and exterior rooms, spaces, or elements that are made available for the use of a restricted group of people (for example, the occupants of an office building, or the guests of such occupants). 4.32.4 902.3 1122B.4 -Counter top at 38" AFF.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 517 Admin. - Copy Room Page 92 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -Twist-type thermostat.EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 518 Admin. - Copy Room 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Storage box at 67" AFF & mail bin at 60" AFF. EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 519 Admin. - Copy Room 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 78" AFF.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 523 Admin. - Elevator Platform 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -4 power outlets and 7 data ports at less than 15" AFF. EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 525 Admin. - Open Office 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -Twist-type thermostat.EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 526 Admin. - Open Office 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Floor mat.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 527 Admin. - Open Office Page 93 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 79" AFF.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 528 Admin. - Open Office 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 79" AFF.EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 530 Admin. - Open Office 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -Twist-type thermostat.EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 532 Admin. - Open Office 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Floor mat.EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 533 Admin. - Open Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -5 power outlets at less than 15" AFF. EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 534 Admin. - Open Office 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -Twist-type thermostat.EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 535 Admin. - Open Office Page 94 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Coat hook above required reach range limit. EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 536 Admin. - Open Office 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Floor mat.EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 537 Admin. - Open Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Power outlet at 14" AFF.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 538 Admin. - Open Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -1 power outlet, 1 data port at 11" AFF. EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 540 Admin. - Office 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 541 Admin. - Office Page 95 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Key lock box at 64" AFF, mail box at 62" AFF. EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 542 Admin. - Hallway 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -Twist-type thermostat.EW - Employee Work Area B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 544 Admin. - Office 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 79 1/2" AFF.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 545 Admin. - Office 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 79 1/2" AFF.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 561 Admin. - Men's Restroom 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 79 1/2" AFF.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 578 Admin. - Women's Restroom 14.27 - > 1/2" Changes in Level Ramps or elevators are not used for changes in level greater than 1/2". (Lifts may only be used in certain limited situations.) 4.1.3(5) ; 4.5.2 303.4; 406 1124B.2 -1/2" change in level from carpet to vinyl flooring. PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 579 Admin. - Women's Restroom 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 78 1/2" AFF.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 589 Admin. - Stairwell Page 96 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.21B - 36" Width Standard The accessible route of travel is not at least 36” wide where the occupancy load is < 10. (For a depth of 24" max.., clear opening width may be reduced to 32" min..) (Doorways are compliant when the door, open 90 degrees, affords a clear opening width of at least 32”.) 4.3.3; Fig. 7(a)(b) 403.5.1; Fig. 403.5.1 1133B.3 .1 -31 1/2" clear, non-fixed partitions. EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 595 Admin. - Break Room 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -Twist-type thermostat.EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 596 Admin. - Break Room 14.37 - Kitchen Sink Sink does not provide accessible knee clearance (i.e. at least 27” high, 30” wide, and 19” deep). 4.24.3 305; 306; 606.2 1115B.4 .7(2); 1122B.4 -Knee space not provided.EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 597 Admin. - Break Room 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -2 power outlets, 1 data port at less than 15" AFF. EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 599 Admin. - Break Room 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Vending machine coin slot at 67" AFF. EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 600 Admin. - Break Room Page 97 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 79 1/4" AFF.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 601 Admin. - Conference Room 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -Twist-type thermostat.EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 603 Admin. - Conference Room 14.30A - Wall- Mounted Protruding Objects Wall-mounted object(s) with leading edges between 27 and 80” from the floor project more than 4" into the pathway. (Wall mounted objects with leading edges at or below 27” may project any amount as long as the required clear width of an accessible route is not reduced.) 4.4.1 307.2; Fig. 307.2 1133B.8 .6.1 -Flat screen TV protrudes at 54" AFF. PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 604 Admin. - Conference Room 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -6 power outlets, 3 data ports.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 606 Admin. - Conference Room 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 79 1/2" AFF.EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 608 Admin. - Office Page 98 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -1 power outlet, 2 data ports.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 609 Admin. - Office 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -Twist-type thermostat.EW - Employee Work Area B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 610 Admin. - Office 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Floor mat.EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 611 Admin. - Office 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 79 1/4" AFF.EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 612 Admin. - Office 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 79 5/8" AFF.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 616 Admin. - Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -4 power outlets, 1 data port.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 617 Admin. - Office Page 99 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Coat hook at 65" AFF.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 618 Admin. - Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -4 power outlets, 1 data port at 11" AFF. EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 619 Admin. - Office 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Floor mat.EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 620 Admin. - Office 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -Twist-type thermostat.EW - Employee Work Area B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 621 Admin. - Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Coat hook.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 622 Admin. - Office Page 100 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 79" AFF.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 625 Admin. - Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -2 power outlets, 1 data port.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 627 Admin. - Office 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 79 1/4" AFF.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 629 Admin. - Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -3 power outlets.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 631 Admin. - Office 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 79 1/4" AFF.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 632 Admin. - Office 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -Twist-type thermostat.EW - Employee Work Area B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 634 Admin. - Office Page 101 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Floor mat.EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 635 Admin. - Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Coat hook at 71" AFF.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 636 Admin. - Office 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 79 1/2" AFF.EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 637 Admin. - Office 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 79 1/4" AFF.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 640 Admin. - Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -6 power outlets, 3 data ports.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 641 Admin. - Office 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -Twist-type thermostat.EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 642 Admin. - Office Page 102 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Floor mat.EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 643 Admin. - Office 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 79 1/4" AFF.EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 645 Admin. - Supply Room 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 77" AFF.EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 647 Admin. - Copy Room 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -First aid kit at 66 1/2" AFF and infection control kit at 77 1/2" AFF. EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 648 Admin. - Copy Room 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -2 power outlets at 11" AFF.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 649 Admin. - Copy Room Page 103 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Phone at 61 1/2" AFF behind obstruction and alarm key pad at 64" AFF. EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 650 Admin. - Copy Room 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Security pad at 61" AFF.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 653 Admin. - Hallway 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 77 1/2" AFF.EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 658 Admin. - Stairwell 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 79" AFF.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 662 Admin. - Hallway 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -2 power outlets at 11" AFF.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 663 Admin. - Hallway Page 104 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 78 3/8" AFF.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 666 Admin. - Office 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 77" AFF.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 667 Admin. - Office 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -Twist-type thermostat.EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 669 Admin. - Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -3 power outlets, 3 data ports.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 670 Admin. - Office 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Floor mat.EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 671 Admin. - Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Coat hook at 70" AFF.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 672 Admin. - Office Page 105 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 79" AFF.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 673 Admin. - Hallway 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 76 3/4" AFF.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 674 Admin. - Office 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -Twist-type thermostat.EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 675 Admin. - Office 14.02 - Accessible Route Accessible routes of travel do not connect the room or space to an accessible entrance within the building or facility. 4.1.3(1) ; 4.3.2(3) 206.2.4; Advisory 206.2.4 1114B.1 .2 -6" change in level between office and storage room. EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 676 Admin. - Office 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Floor mat.EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 678 Admin. - Office 14.36B - Kitchen Counter/Sink Height Where provided in public or common use areas, countertops and sinks are not mounted at 34” AFF. max..(Common use areas are those interior and exterior rooms, spaces, or elements that are made available for the use of a restricted group of people (for example, the occupants of an office building, or the guests of such occupants). 4.24.2 212.3; 606.3 1115B.4 .7(2); 1122B.4 -Counter top at 36" AFF.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 679 Admin. - Break Room 14.37 - Kitchen Sink Sink does not provide accessible knee clearance (i.e. at least 27” high, 30” wide, and 19” deep). 4.24.3 305; 306; 606.2 1115B.4 .7(2); 1122B.4 -Knee space not provided.EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 680 Admin. - Break Room Page 106 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -Non-compliant faucet controls.EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 681 Admin. - Break Room 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Microwave at 64 1/2" AFF.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 683 Admin. - Break Room 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -Non-compliant controls at stove. EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 684 Admin. - Break Room 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Upper cabinets at 72" AFF.EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 685 Admin. - Break Room 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 79 1/2" AFF.EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 686 Admin. - Unisex Restroom 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -Lights above mirror require grasping to power on. EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 703 Admin. - Unisex Restroom Page 107 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 77 1/4" AFF.EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 705 Admin. - Server Room 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Coat hook at 67" AFF.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 709 Admin. - Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -2 power outlets.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 711 Admin. - Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Dry erase board at 51 1/2" AFF. EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 712 Admin. - Office 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 76 3/4" AFF.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 713 Admin. - Office Page 108 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 77" AFF.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 715 Admin. - Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -1 power outlet at 6 1/2" AFF.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 718 Admin. - Office 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Floor mat.EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 719 Admin. - Office 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -Twist-type thermostat.EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 720 Admin. - Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -3 power outlets at 9 1/2" AFF.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 721 Admin. - Hallway Page 109 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Bottom of board at 54 1/2" AFF. EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 723 Admin. - Hallway 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Coat hook at 71" AFF.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 724 Admin. - Office 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 76 3/4" AFF.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 725 Admin. - Office 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -Twist-type thermostat.EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 729 Admin. - Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Thermostat at 58" AFF behind obstruction. EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 730 Admin. - Office Page 110 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -3 power outlets, 1 data port at 7" AFF. EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 731 Admin. - Office 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Floor mat.EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 732 Admin. - Office 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 77 1/4" AFF.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 733 Admin. - Stairwell 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Floor mat.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 736 Admin. - Stairwell 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -1 power outlet at 7" AFF.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 741 Admin. - Stairwell 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 77" AFF.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 744 Admin. - Office Page 111 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -3 power outlets at 7" AFF.EW - Employee Work Area C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 745 Admin. - Office 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -Twist-type thermostat.EW - Employee Work Area B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 746 Admin. - Office 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 76 1/2" AFF.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 747 Admin. - Office 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Floor mat.EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 748 Admin. - Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -3 power outlets, 1 data port at 9" AFF. EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 749 Admin. - Office 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -Twist-type thermostat.EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 750 Admin. - Office Page 112 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Thermostat at 60" AFF.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 751 Admin. - Office 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -Door jamb at 76 1/2" AFF.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 752 Admin. - Office 14.23B - Floor Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Floor mat.EW - Employee Work Area A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 753 Admin. - Office 265Number of Key Notes for Group 14 - Rooms and Spaces: Group 08 - Stairs Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 08.04B - Interior Stairs - Color Strip Standards Contrasting color strips are not compliant. (At interior stairs, CBC Standards require a solid contrasting color strip 2” wide parallel to and not more than 1” away from the nosing on the upper approach and the lower tread of the stairway. The strip shall be of material that is at least as slip resistant as the other treads of the stair.) --1133B.4 .4 -43" x 4 EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 346 Admin. - East Stair Page 113 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 08 - Stairs Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 08.09A - Handrail Extensions - Top Landing At ends of handrails, less than 12” of handrail extends beyond the top nosing. (Top and bottom handrail extensions are important safety features for persons with balance problems and must extend in the direction of the stair run to permit the intended use.) (Per ADA/CBC Standards, in existing buildings and facilities, full extension of handrails at stairs shall not be required in alterations where such extensions would be hazardous or impossible due to plan configuration.) 4.9.4(2) 505.10; 505.10. 2; Fig. 505.10. 2 1133B.4 .2.2 -EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 347 Admin. - East Stair 08.09B - Handrail Extensions - Bottom Landing At ends of handrails, less than 12” plus the tread width extends beyond the bottom nosing. (Top and bottom handrail extensions are important safety features for persons with balance problems and must extend in the direction of the stair run to permit the intended use.) (Per ADA/CBC Standards, in existing buildings and facilities, full extension of handrails at stairs shall not be required in alterations where such extensions would be hazardous or impossible due to plan configuration.) 4.9.4(2) 505.10; 505.10. 3; Fig. 505.10. 3 1133B.4 .2.2 -EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 348 Admin. - East Stair 08.09E - Handrails - Height above Stair Nosings The tops of handrails are not between 34” and 38” above the stair nosings. 4.9.4(5) 505.4; Advisory 505.4; Fig. 505.4 1133B.4 .2.1 -EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 349 Admin. - East Stair Page 114 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 08 - Stairs Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 08.10A - Profile of Handrails The diameter of the handrail is not between 1- 1/4” and 1-1/2” in cross-sectional nomin.al dimension. OR The shape does not provide an equivalent gripping surface (equivalent gripping surfaces are 4” to 6-1/4” in perimeter, and 2- 1/4" max.. in any direction). (Note: Standard pipe sizes designated by the industry as 1-1/4” to 1-1/2” are acceptable). 4.9.4; 4.26.2 505.7.1; 505.7.2; Fig. 505.7.2 1133B.4 .2.6 -2" dia.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 350 Admin. - East Stair 08.10B - Clearance The clear space between handrails and walls is not 1-1/2” absolute. (ADA/CBC Standards apply an absolute dimension of 1-1/2”, which provides knuckle clearance while generally disallowing entrapment of the forearm or elbow.) 4.9.5(3) 505.5 1133B.4 .2.5 -2" clr.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 351 Admin. - East Stair 08.11A - 48" Stairway Width Standard Stairway serving an area of rescue assistance is less than 48” wide between handrails. 4.3.11.3 -1007.3; 1007.6 -35" wide.EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 352 Admin. - East Stair 08.13A - Guards Where drop exceeds 30”, a min.. 42” high guard has not been provided as a vertical barrier along the open edges of ramp or landing to prevent persons from falling off the open edge. 4.8.7 505.1; 505.1 Advisory 1013; 1133B.5 .7 -EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 353 Admin. - East Stair 08.04B - Interior Stairs - Color Strip Standards Contrasting color strips are not compliant. (At interior stairs, CBC Standards require a solid contrasting color strip 2” wide parallel to and not more than 1” away from the nosing on the upper approach and the lower tread of the stairway. The strip shall be of material that is at least as slip resistant as the other treads of the stair.) --1133B.4 .4 -46" X 4.EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 363 Admin. - Stairwell Page 115 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 08 - Stairs Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 08.09A - Handrail Extensions - Top Landing At ends of handrails, less than 12” of handrail extends beyond the top nosing. (Top and bottom handrail extensions are important safety features for persons with balance problems and must extend in the direction of the stair run to permit the intended use.) (Per ADA/CBC Standards, in existing buildings and facilities, full extension of handrails at stairs shall not be required in alterations where such extensions would be hazardous or impossible due to plan configuration.) 4.9.4(2) 505.10; 505.10. 2; Fig. 505.10. 2 1133B.4 .2.2 -Extensions not provided.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 364 Admin. - Stairwell 08.09B - Handrail Extensions - Bottom Landing At ends of handrails, less than 12” plus the tread width extends beyond the bottom nosing. (Top and bottom handrail extensions are important safety features for persons with balance problems and must extend in the direction of the stair run to permit the intended use.) (Per ADA/CBC Standards, in existing buildings and facilities, full extension of handrails at stairs shall not be required in alterations where such extensions would be hazardous or impossible due to plan configuration.) 4.9.4(2) 505.10; 505.10. 3; Fig. 505.10. 3 1133B.4 .2.2 -Extensions not provided.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 365 Admin. - Stairwell 08.10A - Profile of Handrails The diameter of the handrail is not between 1- 1/4” and 1-1/2” in cross-sectional nomin.al dimension. OR The shape does not provide an equivalent gripping surface (equivalent gripping surfaces are 4” to 6-1/4” in perimeter, and 2- 1/4" max.. in any direction). (Note: Standard pipe sizes designated by the industry as 1-1/4” to 1-1/2” are acceptable). 4.9.4; 4.26.2 505.7.1; 505.7.2; Fig. 505.7.2 1133B.4 .2.6 -1 3/4" diameter.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 366 Admin. - Stairwell Page 116 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 08 - Stairs Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 08.10B - Clearance The clear space between handrails and walls is not 1-1/2” absolute. (ADA/CBC Standards apply an absolute dimension of 1-1/2”, which provides knuckle clearance while generally disallowing entrapment of the forearm or elbow.) 4.9.5(3) 505.5 1133B.4 .2.5 -2" clear.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 367 Admin. - Stairwell 08.11A - 48" Stairway Width Standard Stairway serving an area of rescue assistance is less than 48” wide between handrails. 4.3.11.3 -1007.3; 1007.6 -39 3/4" clear.EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 368 Admin. - Stairwell 08.13A - Guards Where drop exceeds 30”, a min.. 42” high guard has not been provided as a vertical barrier along the open edges of ramp or landing to prevent persons from falling off the open edge. 4.8.7 505.1; 505.1 Advisory 1013; 1133B.5 .7 -Not provided.EC - Employee Common Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 369 Admin. - Stairwell 08.09E - Handrails - Height above Stair Nosings The tops of handrails are not between 34” and 38” above the stair nosings. 4.9.4(5) 505.4; Advisory 505.4; Fig. 505.4 1133B.4 .2.1 -32" above nosing.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 370 Admin. - Stairwell 08.15 - Landing Size Landing depth in the direction of travel is not at least equal to the width of the stairway. --1009.4 -42 1/2" bottom landing.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 371 Admin. - Stairwell 08.04A - Interior Stairs - Color Strip Contrasting color strips have not been provided. --1133B.4 .4 -EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 415 Admin. - Stairs 08.07A - Continuous Handrails Continuous handrails are not provided along both sides. 4.9.4 504.6; 505.2 1133B.4 .1.1 -Not provided on both sides.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 416 Admin. - Stairs Page 117 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 08 - Stairs Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 08.09A - Handrail Extensions - Top Landing At ends of handrails, less than 12” of handrail extends beyond the top nosing. (Top and bottom handrail extensions are important safety features for persons with balance problems and must extend in the direction of the stair run to permit the intended use.) (Per ADA/CBC Standards, in existing buildings and facilities, full extension of handrails at stairs shall not be required in alterations where such extensions would be hazardous or impossible due to plan configuration.) 4.9.4(2) 505.10; 505.10. 2; Fig. 505.10. 2 1133B.4 .2.2 -Not provided.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 417 Admin. - Stairs 08.09B - Handrail Extensions - Bottom Landing At ends of handrails, less than 12” plus the tread width extends beyond the bottom nosing. (Top and bottom handrail extensions are important safety features for persons with balance problems and must extend in the direction of the stair run to permit the intended use.) (Per ADA/CBC Standards, in existing buildings and facilities, full extension of handrails at stairs shall not be required in alterations where such extensions would be hazardous or impossible due to plan configuration.) 4.9.4(2) 505.10; 505.10. 3; Fig. 505.10. 3 1133B.4 .2.2 -Not provided.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 418 Admin. - Stairs 08.10B - Clearance The clear space between handrails and walls is not 1-1/2” absolute. (ADA/CBC Standards apply an absolute dimension of 1-1/2”, which provides knuckle clearance while generally disallowing entrapment of the forearm or elbow.) 4.9.5(3) 505.5 1133B.4 .2.5 -1 3/4" clear.EC - Employee Common Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 419 Admin. - Stairs Page 118 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 08 - Stairs Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 08.04B - Interior Stairs - Color Strip Standards Contrasting color strips are not compliant. (At interior stairs, CBC Standards require a solid contrasting color strip 2” wide parallel to and not more than 1” away from the nosing on the upper approach and the lower tread of the stairway. The strip shall be of material that is at least as slip resistant as the other treads of the stair.) --1133B.4 .4 -EC - Employee Common Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 481 Admin. - S. Stairwell 08.07A - Continuous Handrails Continuous handrails are not provided along both sides. 4.9.4 504.6; 505.2 1133B.4 .1.1 -EC - Employee Common Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 482 Admin. - S. Stairwell 08.09A - Handrail Extensions - Top Landing At ends of handrails, less than 12” of handrail extends beyond the top nosing. (Top and bottom handrail extensions are important safety features for persons with balance problems and must extend in the direction of the stair run to permit the intended use.) (Per ADA/CBC Standards, in existing buildings and facilities, full extension of handrails at stairs shall not be required in alterations where such extensions would be hazardous or impossible due to plan configuration.) 4.9.4(2) 505.10; 505.10. 2; Fig. 505.10. 2 1133B.4 .2.2 -None provided EC - Employee Common Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 483 Admin. - S. Stairwell 08.09B - Handrail Extensions - Bottom Landing At ends of handrails, less than 12” plus the tread width extends beyond the bottom nosing. (Top and bottom handrail extensions are important safety features for persons with balance problems and must extend in the direction of the stair run to permit the intended use.) (Per ADA/CBC Standards, in existing buildings and facilities, full extension of handrails at stairs shall not be required in alterations where such extensions would be hazardous or impossible due to plan configuration.) 4.9.4(2) 505.10; 505.10. 3; Fig. 505.10. 3 1133B.4 .2.2 -None provided EC - Employee Common Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 484 Admin. - S. Stairwell Page 119 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 08 - Stairs Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 08.10A - Profile of Handrails The diameter of the handrail is not between 1- 1/4” and 1-1/2” in cross-sectional nomin.al dimension. OR The shape does not provide an equivalent gripping surface (equivalent gripping surfaces are 4” to 6-1/4” in perimeter, and 2- 1/4" max.. in any direction). (Note: Standard pipe sizes designated by the industry as 1-1/4” to 1-1/2” are acceptable). 4.9.4; 4.26.2 505.7.1; 505.7.2; Fig. 505.7.2 1133B.4 .2.6 -1 3/4" dia EC - Employee Common Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 485 Admin. - S. Stairwell 08.10B - Clearance The clear space between handrails and walls is not 1-1/2” absolute. (ADA/CBC Standards apply an absolute dimension of 1-1/2”, which provides knuckle clearance while generally disallowing entrapment of the forearm or elbow.) 4.9.5(3) 505.5 1133B.4 .2.5 -2 1/8" clr EC - Employee Common Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 486 Admin. - S. Stairwell 08.11A - 48" Stairway Width Standard Stairway serving an area of rescue assistance is less than 48” wide between handrails. 4.3.11.3 -1007.3; 1007.6 -34 3/4" high EC - Employee Common Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 487 Admin. - S. Stairwell 08.13A - Guards Where drop exceeds 30”, a min.. 42” high guard has not been provided as a vertical barrier along the open edges of ramp or landing to prevent persons from falling off the open edge. 4.8.7 505.1; 505.1 Advisory 1013; 1133B.5 .7 -EC - Employee Common Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 488 Admin. - S. Stairwell 08.09E - Handrails - Height above Stair Nosings The tops of handrails are not between 34” and 38” above the stair nosings. 4.9.4(5) 505.4; Advisory 505.4; Fig. 505.4 1133B.4 .2.1 -29 1/2" high EC - Employee Common Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 489 Admin. - S. Stairwell 31Number of Key Notes for Group 08 - Stairs: Group 12B - Tenant Lobbies and Reception Areas Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation Page 120 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 12B - Tenant Lobbies and Reception Areas Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 12B.11C - Counter - Knee Space Depth Where seating for persons in wheelchairs is provided at table or counter, knee space is not at least 19" deep. 4.32.3 305; 306 1122B.3 -4 1/2" knee depth.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 139 Comm. Dev. - Planning Dept. Counter 12B.11C - Counter - Knee Space Depth Where seating for persons in wheelchairs is provided at table or counter, knee space is not at least 19" deep. 4.32.3 305; 306 1122B.3 -6 1/2" knee depth.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 159 Comm. Dev. - Cashier 2Number of Key Notes for Group 12B - Tenant Lobbies and Reception Areas: Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.09A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6 404.2.4. 1; Table 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2; Fig. 11B-26 -9" to counter at pull side.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 44 Ch. 33 - Restroom Page 121 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand. OR They are not operable without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Door knob & twist-type locking mechanisms. PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 45 Ch. 33 - Restroom 16.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -22 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 46 Ch. 33 - Restroom 16.13C - Unisex RR Geometric Symbol Signage - Circle/Triangle Doorway leading to a unisex toilet room is not identified by a 12” circle, 1/4" with a 1/4" thick triangle superimposed and within the circle. OR Circle and triangle are provided, however they are accompanied by words in raised characters and Braille. (ADA and CBC Standards require a separate sign with raised characters and Braille mounted on the wall adjacent to the latch side of the door.) --1115B.6 -PV - Public/Visitor Use D - Minor Code Deviation 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 48 Ch. 33 - Restroom 16.15A - Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.30.1 216.2; 703.1; 703.2; 703.5 1117B.5 .1(1) -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 49 Ch. 33 - Restroom 16.18A - ISA Accessible toilet room is not identified by an ISA. 4.1.3(16 )(b) 216.8 1117B.5 .1(3) -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 50 Ch. 33 - Restroom Page 122 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.27A - 60” Wide Circle or T- Shaped Maneuvering Space The toilet room does not include an unobstructed turning space (a 60” diameter, 27" high circle or T-shaped space). (Note: The clear floor space of fixtures and controls, the accessible path of travel, and the turning space may overlap.) 4.22.3; Fig 3 304.3.2; Fig.304. 3.2; 603.2.1 1115B.3 .1(1); 1115B.3 .2(1) -42" diameter circle provided.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 51 Ch. 33 - Restroom 16.01 - Toilet Rooms Toilet room does not comply with all applicable ADAAG and CBC accessibility requirements. 4.1.2(6) ; 4.1.3(11 ); 4.22.1 213.2; Advisory 213.2 1115B.1 -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 52 Ch. 33 - Restroom 16.69 - Width Between Screens at Urinal - Min. 36" Standard Where urinal screens are provided and they extend more than 24” beyond the front edge of the urinal rim, there is less than 36” between the two panels. 4.18.3; Fig. 4(e) -1115B.4 .2(3); 1118B.4 (1); Fig. 11B-5A -32" wide.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 53 Ch. 33 - Restroom 16.65D - Urinal Flush Controls - Height Height of urinal flush controls exceeds 44" AFF.4.18.4 605.4; 604.6; Advisory 604.6 1115B.4 .2(2) -46" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 54 Ch. 33 - Restroom 16.70 - Lavatories Lavatory does not comply with ADAAG and CBC requirements. (ADA Standards require at least one lavatory to be accessible. CBC Standards prior to August 1, 2009 required all lavatories to be accessible. Effective August 1, 2009, amended CBC Standards require at least 5% of lavatories, but not less than one lavatory, to be accessible.) 4.22.6 213.3.4; 606.1 1115B.4 .3 -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 55 Ch. 33 - Restroom Page 123 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.82A - Mirror Height - Max. 40" AFF Standard Mirror above accessible lavatory or countertop is mounted so the bottom edge of the reflective surface is not 40” max.. AFF. (ADA Standards require at least one mirror to be accessible; CBC Standards prior to August 1, 2009 required all mirrors to be accessible. Effective August 1, 2009, amended CBC Standards require all mirrors above accessible lavatories or countertops to be accessible.) 4.19.6; Fig. 31 213.3.5; 603.3; Advisory 603.3 1115B.8 .1 -51 1/2" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 56 Ch. 33 - Restroom 16.84A - Paper Towel Dispenser - Operating Height Mounting height of paper towel dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one paper towel dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one paper towel dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -45" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 57 Ch. 33 - Restroom 16.83 - Coat Hook - Height Where a coat hook is provided In an accessible stall, height of coat hook exceeds 48” AFF. 4.2.5 213.3.7; 308; 603.4 1117B.8 -74" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 59 Ch. 33 - Restroom Page 124 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.09A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6 404.2.4. 1; Table 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2; Fig. 11B-26 -35 1/2" landing at latch approach, pull side. PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 61 Ch. 33 - Restroom 16.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -11 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 62 Ch. 33 - Restroom 16.88 - Other - Toilet Facilities See Additional Comments ----Door cannot open 90 degrees.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 63 Ch. 33 - Restroom 16.88 - Other - Toilet Facilities See Additional Comments ----9" high kick plate and door stop at kick plate area. PV - Public/Visitor Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 64 Ch. 33 - Restroom Page 125 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.13C - Unisex RR Geometric Symbol Signage - Circle/Triangle Doorway leading to a unisex toilet room is not identified by a 12” circle, 1/4" with a 1/4" thick triangle superimposed and within the circle. OR Circle and triangle are provided, however they are accompanied by words in raised characters and Braille. (ADA and CBC Standards require a separate sign with raised characters and Braille mounted on the wall adjacent to the latch side of the door.) --1115B.6 -PV - Public/Visitor Use D - Minor Code Deviation 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 65 Ch. 33 - Restroom 16.15A - Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.30.1 216.2; 703.1; 703.2; 703.5 1117B.5 .1(1) -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 66 Ch. 33 - Restroom 16.18A - ISA Accessible toilet room is not identified by an ISA. 4.1.3(16 )(b) 216.8 1117B.5 .1(3) -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 67 Ch. 33 - Restroom 16.08A - Door Swing The door swing intrudes into the clear floor space of one or more fixtures. 4.22.2 603.2.3; Advisory 603.2.3 1115B.3 .1 item 2; 1115B.3 .2 item 2; 1115B.5 -Door swing encroaches lavatory clear floor space. PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 78 Comm. Dev. - Public Restroom 16.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -11 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 79 Comm. Dev. - Public Restroom Page 126 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.13C - Unisex RR Geometric Symbol Signage - Circle/Triangle Doorway leading to a unisex toilet room is not identified by a 12” circle, 1/4" with a 1/4" thick triangle superimposed and within the circle. OR Circle and triangle are provided, however they are accompanied by words in raised characters and Braille. (ADA and CBC Standards require a separate sign with raised characters and Braille mounted on the wall adjacent to the latch side of the door.) --1115B.6 -Braille on door sign.PV - Public/Visitor Use D - Minor Code Deviation 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 80 Comm. Dev. - Public Restroom 16.15A - Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.30.1 216.2; 703.1; 703.2; 703.5 1117B.5 .1(1) -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 81 Comm. Dev. - Public Restroom 16.18A - ISA Accessible toilet room is not identified by an ISA. 4.1.3(16 )(b) 216.8 1117B.5 .1(3) -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 82 Comm. Dev. - Public Restroom 16.27A - 60” Wide Circle or T- Shaped Maneuvering Space The toilet room does not include an unobstructed turning space (a 60” diameter, 27" high circle or T-shaped space). (Note: The clear floor space of fixtures and controls, the accessible path of travel, and the turning space may overlap.) 4.22.3; Fig 3 304.3.2; Fig.304. 3.2; 603.2.1 1115B.3 .1(1); 1115B.3 .2(1) -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 83 Comm. Dev. - Public Restroom 16.88 - Other - Toilet Facilities See Additional Comments ----Threshold.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 84 Comm. Dev. - Public Restroom Page 127 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.42 - 28" Wide Standard - Side Transfer Space Where the WC is not in a stall and there is another fixture alongside the toilet, the clear floor space is less than 28” wide. --1115B.4 .1(1); Fig. 11B-1A -17 1/4" clear.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 85 Comm. Dev. - Public Restroom 16.49B - WC Flush Controls - Location Flush controls are not located on the wide side of the WC where the clear floor space is provided. 4.16.5 604.6; Advisory 604.6 1115B.4 .1(5); Fig. 11B-1A -Not on wide side.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 86 Comm. Dev. - Public Restroom 16.50 - TP Dispenser - Location - Pre- 2007 CBC Facility Location of the toilet paper dispenser does not comply with the Standard in effect at the time of construction. (The 2001 CBC required toilet tissue dispensers located on the wall within 12" of the front edge of the toilet seat, measured to the centerline of the dispenser; mounted below the grab bar; and centered at a min. height of 19" AFF.) 4.16.6; Fig. 29(b) 604.7; Advisory 604.7; Fig. 604.7 --44 1/2" from back wall.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 87 Comm. Dev. - Public Restroom 16.55A - Side Grab Bar Height Side grab bar is not centered at 33" AFF. (ADA Standards require side grab bars to be centered from 33" to 36" AFF; CBC Standards require side grab bars to be centered at 33" AFF.) 4.17.6; Figs. 29 & 30 604.5; Advisory 604.5; 604.5.2; Fig. 604.5.2; 609.4 1115B.4 .1(3.1); Fig. 11B-1A -35" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 88 Comm. Dev. - Public Restroom 16.56 - Grab Bar Wall Clearance The space between the grab bar and the wall is not 1-1/2” absolute. 4.17.6, 4.26.2; Fig. 39 609.3 1115B.7 .1; Fig. 11B-1C -1 5/8" clear.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 89 Comm. Dev. - Public Restroom Page 128 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.59 - Side Grab Bar At WC providing front transfer, the side grab bar location is not compliant. (CBC Standards require the side grab bar to extend at least 54” min.. beyond the back wall while the other end is 12” max.. from the back wall. CBC also requires the grab bar's front end to be positioned 24” min.. in front of the WC.) 4.17.6; Figs. 29 & 30 Fig. 604.5.1 1115B.4 .1(3.1); Fig. 11B-1A -50 1/2".PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 90 Comm. Dev. - Public Restroom 16.72 - Lavatory Apron Clearance Lavatory does not provide accessible apron clearance (i.e. at least 29” clearance from the floor to the bottom of the apron). 4.19.2; Fig. 31 606.3 1115B.4 .3(2); Fig 11B- 1D -28 1/2" clear.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 91 Comm. Dev. - Public Restroom 16.73 - Lavatory Knee Clearance Lavatory does not provide accessible knee clearance (i.e. at least 27” clearance from the floor to the underside of the lavatory, extending 8” min.. measured from the front edge underneath the lavatory back towards the wall). 4.19.2; Fig. 31 306.3; Fig. 306.3 1115B.4 .3(2); Fig 11B- 1D -26 1/4" clear.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 92 Comm. Dev. - Public Restroom 16.76 - Lavatory - Clearance near Sidewall The centerline of the lavatory is not 18” min.. from the nearest sidewall or partition. --1115B.4 .3(2); Fig 11B- 1D -16" from side wall.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 93 Comm. Dev. - Public Restroom 16.82A - Mirror Height - Max. 40" AFF Standard Mirror above accessible lavatory or countertop is mounted so the bottom edge of the reflective surface is not 40” max.. AFF. (ADA Standards require at least one mirror to be accessible; CBC Standards prior to August 1, 2009 required all mirrors to be accessible. Effective August 1, 2009, amended CBC Standards require all mirrors above accessible lavatories or countertops to be accessible.) 4.19.6; Fig. 31 213.3.5; 603.3; Advisory 603.3 1115B.8 .1 -40 3/4" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 94 Comm. Dev. - Public Restroom Page 129 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.84A - Paper Towel Dispenser - Operating Height Mounting height of paper towel dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one paper towel dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one paper towel dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -40 1/2" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 95 Comm. Dev. - Public Restroom 16.84C - Soap Dispenser - Operating Height Mounting height of soap dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one soap dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one soap dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -40 1/2" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 96 Comm. Dev. - Public Restroom 16.84D - Sanitary Napkin/Feminine Hygiene Dispenser - Operating Height Mounting height of sanitary napkin/femin.ine hygiene dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one sanitary napkin/femin.ine hygiene dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one sanitary napkin/femin.ine hygiene dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -46" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 98 Comm. Dev. - Public Restroom Page 130 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.09A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6 404.2.4. 1; Table 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2; Fig. 11B-26 -13" pull side, lavatory.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 100 Comm. Dev. - Men's Staff Restroom 16.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -7 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 101 Comm. Dev. - Men's Staff Restroom 16.13A - Men's RR Geometric Symbol Signage - Triangle Doorway leading to a men’s toilet room is not identified by an equilateral triangle 1/4" thick with edges 12” long. OR Equilateral triangle is provided, however it is accompanied by words in raised characters and Braille. (ADA and CBC Standards require a separate sign with raised characters and Braille mounted on the wall adjacent to the latch side of the door.) --1115B.6 -Braille on sign.PV - Public/Visitor Use D - Minor Code Deviation 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 102 Comm. Dev. - Men's Staff Restroom 16.15A - Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.30.1 216.2; 703.1; 703.2; 703.5 1117B.5 .1(1) -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 103 Comm. Dev. - Men's Staff Restroom Page 131 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.18A - ISA Accessible toilet room is not identified by an ISA. 4.1.3(16 )(b) 216.8 1117B.5 .1(3) -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 104 Comm. Dev. - Men's Staff Restroom 16.27A - 60” Wide Circle or T- Shaped Maneuvering Space The toilet room does not include an unobstructed turning space (a 60” diameter, 27" high circle or T-shaped space). (Note: The clear floor space of fixtures and controls, the accessible path of travel, and the turning space may overlap.) 4.22.3; Fig 3 304.3.2; Fig.304. 3.2; 603.2.1 1115B.3 .1(1); 1115B.3 .2(1) -49" clear.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 105 Comm. Dev. - Men's Staff Restroom 16.42 - 28" Wide Standard - Side Transfer Space Where the WC is not in a stall and there is another fixture alongside the toilet, the clear floor space is less than 28” wide. --1115B.4 .1(1); Fig. 11B-1A -16" to wall.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 106 Comm. Dev. - Men's Staff Restroom 16.47A - WC Location from Sidewall The centerline of the WC is not 18” absolute from a wall or partition. 4.22.4 -1115B.4 .1(1) -18 1/2" from side wall.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 107 Comm. Dev. - Men's Staff Restroom 16.50 - TP Dispenser - Location - Pre- 2007 CBC Facility Location of the toilet paper dispenser does not comply with the Standard in effect at the time of construction. (The 2001 CBC required toilet tissue dispensers located on the wall within 12" of the front edge of the toilet seat, measured to the centerline of the dispenser; mounted below the grab bar; and centered at a min. height of 19" AFF.) 4.16.6; Fig. 29(b) 604.7; Advisory 604.7; Fig. 604.7 --41" from back wall.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 108 Comm. Dev. - Men's Staff Restroom Page 132 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.55A - Side Grab Bar Height Side grab bar is not centered at 33" AFF. (ADA Standards require side grab bars to be centered from 33" to 36" AFF; CBC Standards require side grab bars to be centered at 33" AFF.) 4.17.6; Figs. 29 & 30 604.5; Advisory 604.5; 604.5.2; Fig. 604.5.2; 609.4 1115B.4 .1(3.1); Fig. 11B-1A -35 1/4" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 109 Comm. Dev. - Men's Staff Restroom 16.56 - Grab Bar Wall Clearance The space between the grab bar and the wall is not 1-1/2” absolute. 4.17.6, 4.26.2; Fig. 39 609.3 1115B.7 .1; Fig. 11B-1C -1 3/4" clear.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 110 Comm. Dev. - Men's Staff Restroom 16.59 - Side Grab Bar At WC providing front transfer, the side grab bar location is not compliant. (CBC Standards require the side grab bar to extend at least 54” min.. beyond the back wall while the other end is 12” max.. from the back wall. CBC also requires the grab bar's front end to be positioned 24” min.. in front of the WC.) 4.17.6; Figs. 29 & 30 Fig. 604.5.1 1115B.4 .1(3.1); Fig. 11B-1A -51 1/2".PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 111 Comm. Dev. - Men's Staff Restroom 16.49B - WC Flush Controls - Location Flush controls are not located on the wide side of the WC where the clear floor space is provided. 4.16.5 604.6; Advisory 604.6 1115B.4 .1(5); Fig. 11B-1A -Not on wide side.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 112 Comm. Dev. - Men's Staff Restroom 16.72 - Lavatory Apron Clearance Lavatory does not provide accessible apron clearance (i.e. at least 29” clearance from the floor to the bottom of the apron). 4.19.2; Fig. 31 606.3 1115B.4 .3(2); Fig 11B- 1D -27 3/4" clear.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 113 Comm. Dev. - Men's Staff Restroom 16.73 - Lavatory Knee Clearance Lavatory does not provide accessible knee clearance (i.e. at least 27” clearance from the floor to the underside of the lavatory, extending 8” min.. measured from the front edge underneath the lavatory back towards the wall). 4.19.2; Fig. 31 306.3; Fig. 306.3 1115B.4 .3(2); Fig 11B- 1D -25 1/2" clear.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 114 Comm. Dev. - Men's Staff Restroom Page 133 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.75 - Clear Floor Space at Lavatory There is no clear floor space at least 30” x 48” in front of the lavatory (extending a maximum of 19” underneath the lavatory) to allow a forward approach. 4.19.3; 4.2.4 606.2 1115B.4 .3(3); Fig 11B- 1D -Door swing encroaches clear floor space. PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 115 Comm. Dev. - Men's Staff Restroom 16.76 - Lavatory - Clearance near Sidewall The centerline of the lavatory is not 18” min.. from the nearest sidewall or partition. --1115B.4 .3(2); Fig 11B- 1D -17" from side wall.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 116 Comm. Dev. - Men's Staff Restroom 16.82A - Mirror Height - Max. 40" AFF Standard Mirror above accessible lavatory or countertop is mounted so the bottom edge of the reflective surface is not 40” max.. AFF. (ADA Standards require at least one mirror to be accessible; CBC Standards prior to August 1, 2009 required all mirrors to be accessible. Effective August 1, 2009, amended CBC Standards require all mirrors above accessible lavatories or countertops to be accessible.) 4.19.6; Fig. 31 213.3.5; 603.3; Advisory 603.3 1115B.8 .1 -40 1/4" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 117 Comm. Dev. - Men's Staff Restroom 16.84C - Soap Dispenser - Operating Height Mounting height of soap dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one soap dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one soap dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -41" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 118 Comm. Dev. - Men's Staff Restroom Page 134 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.84A - Paper Towel Dispenser - Operating Height Mounting height of paper towel dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one paper towel dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one paper towel dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -40 1/2" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 119 Comm. Dev. - Men's Staff Restroom 16.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand. OR They are not operable without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Locking mechanism.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 122 Comm. Dev. - Women's Staff Restroom 16.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -11 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 123 Comm. Dev. - Women's Staff Restroom 16.13B - Women's RR Geometric Symbol Signage - Circle Doorway leading to a women’s toilet room is not identified by a circle, 1/4" thick and 12” in diameter. OR Circle is provided, however it is accompanied by words in raised characters and Braille. (ADA and CBC Standards require a separate sign with raised characters and Braille mounted on the wall adjacent to the latch side of the door.) --1115B.6 -Braille on sign.PV - Public/Visitor Use D - Minor Code Deviation 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 124 Comm. Dev. - Women's Staff Restroom Page 135 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.14A - Mounting Height - Geometric Symbol Signage The geometric symbol is not centered on the door leaf. OR The symbol is not mounted at a height of 60” AFF. --1115B.6 -65" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 125 Comm. Dev. - Women's Staff Restroom 16.15A - Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.30.1 216.2; 703.1; 703.2; 703.5 1117B.5 .1(1) -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 126 Comm. Dev. - Women's Staff Restroom 16.18A - ISA Accessible toilet room is not identified by an ISA. 4.1.3(16 )(b) 216.8 1117B.5 .1(3) -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 127 Comm. Dev. - Women's Staff Restroom 16.42 - 28" Wide Standard - Side Transfer Space Where the WC is not in a stall and there is another fixture alongside the toilet, the clear floor space is less than 28” wide. --1115B.4 .1(1); Fig. 11B-1A -16" to waste bin.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 128 Comm. Dev. - Women's Staff Restroom 16.47A - WC Location from Sidewall The centerline of the WC is not 18” absolute from a wall or partition. 4.22.4 -1115B.4 .1(1) -21" from side wall.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 129 Comm. Dev. - Women's Staff Restroom 16.49B - WC Flush Controls - Location Flush controls are not located on the wide side of the WC where the clear floor space is provided. 4.16.5 604.6; Advisory 604.6 1115B.4 .1(5); Fig. 11B-1A -Not on wide side.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 130 Comm. Dev. - Women's Staff Restroom Page 136 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.50 - TP Dispenser - Location - Pre- 2007 CBC Facility Location of the toilet paper dispenser does not comply with the Standard in effect at the time of construction. (The 2001 CBC required toilet tissue dispensers located on the wall within 12" of the front edge of the toilet seat, measured to the centerline of the dispenser; mounted below the grab bar; and centered at a min. height of 19" AFF.) 4.16.6; Fig. 29(b) 604.7; Advisory 604.7; Fig. 604.7 --44" from back wall.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 131 Comm. Dev. - Women's Staff Restroom 16.56 - Grab Bar Wall Clearance The space between the grab bar and the wall is not 1-1/2” absolute. 4.17.6, 4.26.2; Fig. 39 609.3 1115B.7 .1; Fig. 11B-1C -1 5/8" clear.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 132 Comm. Dev. - Women's Staff Restroom 16.59 - Side Grab Bar At WC providing front transfer, the side grab bar location is not compliant. (CBC Standards require the side grab bar to extend at least 54” min.. beyond the back wall while the other end is 12” max.. from the back wall. CBC also requires the grab bar's front end to be positioned 24” min.. in front of the WC.) 4.17.6; Figs. 29 & 30 Fig. 604.5.1 1115B.4 .1(3.1); Fig. 11B-1A -52 1/4".PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 133 Comm. Dev. - Women's Staff Restroom 16.71 - Lavatory - Rim Height Height of lavatory rim or counter surface exceeds 34” AFF. 4.19.2; Fig. 31 606.3 1115B.4 .3(2); Fig 11B- 1D -34 3/8" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 134 Comm. Dev. - Women's Staff Restroom Page 137 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.82A - Mirror Height - Max. 40" AFF Standard Mirror above accessible lavatory or countertop is mounted so the bottom edge of the reflective surface is not 40” max.. AFF. (ADA Standards require at least one mirror to be accessible; CBC Standards prior to August 1, 2009 required all mirrors to be accessible. Effective August 1, 2009, amended CBC Standards require all mirrors above accessible lavatories or countertops to be accessible.) 4.19.6; Fig. 31 213.3.5; 603.3; Advisory 603.3 1115B.8 .1 -42" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 135 Comm. Dev. - Women's Staff Restroom 16.84C - Soap Dispenser - Operating Height Mounting height of soap dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one soap dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one soap dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -41 3/8" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 136 Comm. Dev. - Women's Staff Restroom 16.84A - Paper Towel Dispenser - Operating Height Mounting height of paper towel dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one paper towel dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one paper towel dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -42" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 137 Comm. Dev. - Women's Staff Restroom 16.04 - Accessible Path of Travel Toilet room is not located on an accessible route of travel. 4.22.1 206.2.4; Advisory 206.2.4 1115B.1 -EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 377 Admin. - Men's Restroom Page 138 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand. OR They are not operable without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Twist-type locking mechanism.EC - Employee Common Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 378 Admin. - Men's Restroom 16.13A - Men's RR Geometric Symbol Signage - Triangle Doorway leading to a men’s toilet room is not identified by an equilateral triangle 1/4" thick with edges 12” long. OR Equilateral triangle is provided, however it is accompanied by words in raised characters and Braille. (ADA and CBC Standards require a separate sign with raised characters and Braille mounted on the wall adjacent to the latch side of the door.) --1115B.6 -EC - Employee Common Use D - Minor Code Deviation 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 379 Admin. - Men's Restroom 16.15A - Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.30.1 216.2; 703.1; 703.2; 703.5 1117B.5 .1(1) -EC - Employee Common Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 380 Admin. - Men's Restroom 16.18A - ISA Accessible toilet room is not identified by an ISA. 4.1.3(16 )(b) 216.8 1117B.5 .1(3) -EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 381 Admin. - Men's Restroom 16.27A - 60” Wide Circle or T- Shaped Maneuvering Space The toilet room does not include an unobstructed turning space (a 60” diameter, 27" high circle or T-shaped space). (Note: The clear floor space of fixtures and controls, the accessible path of travel, and the turning space may overlap.) 4.22.3; Fig 3 304.3.2; Fig.304. 3.2; 603.2.1 1115B.3 .1(1); 1115B.3 .2(1) -51" diameter.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 382 Admin. - Men's Restroom Page 139 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.42 - 28" Wide Standard - Side Transfer Space Where the WC is not in a stall and there is another fixture alongside the toilet, the clear floor space is less than 28” wide. --1115B.4 .1(1); Fig. 11B-1A -25" clear.EC - Employee Common Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 383 Admin. - Men's Restroom 16.47A - WC Location from Sidewall The centerline of the WC is not 18” absolute from a wall or partition. 4.22.4 -1115B.4 .1(1) -17 1/2" from side wall.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 384 Admin. - Men's Restroom 16.48 - WC Seat Height The top of the WC seat is not between 17” and 19” AFF. 4.16.3; Fig. 29(b) 604.4 1115B.4 .1(4); Fig. 11B-1A -15" AFF.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 385 Admin. - Men's Restroom 16.53 - SC Dispenser Height Mounting height of seat cover dispenser's highest operable part exceeds 40" AFF. 4.22.7; 4.27.3; 4.2.5; 4.2.6 -1115B.8 .3 -43" AFF.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 386 Admin. - Men's Restroom 16.54A - Grab Bar Grab bar is not provided.4.17.6; Figs. 29 & 30 604.5; Advisory 604.5; 609.4 1115B.4 .1(3.1) & (3.2); Fig. 11B-1A -EC - Employee Common Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 387 Admin. - Men's Restroom 16.50 - TP Dispenser - Location - Pre- 2007 CBC Facility Location of the toilet paper dispenser does not comply with the Standard in effect at the time of construction. (The 2001 CBC required toilet tissue dispensers located on the wall within 12" of the front edge of the toilet seat, measured to the centerline of the dispenser; mounted below the grab bar; and centered at a min. height of 19" AFF.) 4.16.6; Fig. 29(b) 604.7; Advisory 604.7; Fig. 604.7 --20" & 51"EC - Employee Common Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 388 Admin. - Men's Restroom Page 140 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.70 - Lavatories Lavatory does not comply with ADAAG and CBC requirements. (ADA Standards require at least one lavatory to be accessible. CBC Standards prior to August 1, 2009 required all lavatories to be accessible. Effective August 1, 2009, amended CBC Standards require at least 5% of lavatories, but not less than one lavatory, to be accessible.) 4.22.6 213.3.4; 606.1 1115B.4 .3 -Knee space not provided.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 389 Admin. - Men's Restroom 16.80 - Faucet Operation at Lavatory The faucet is not compliant. (Accessible faucets shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.19.5; 4.27.4 309.4; 606.4 1115B.4 .3(1) -Twist-type faucet control.EC - Employee Common Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 390 Admin. - Men's Restroom 16.82A - Mirror Height - Max. 40" AFF Standard Mirror above accessible lavatory or countertop is mounted so the bottom edge of the reflective surface is not 40” max.. AFF. (ADA Standards require at least one mirror to be accessible; CBC Standards prior to August 1, 2009 required all mirrors to be accessible. Effective August 1, 2009, amended CBC Standards require all mirrors above accessible lavatories or countertops to be accessible.) 4.19.6; Fig. 31 213.3.5; 603.3; Advisory 603.3 1115B.8 .1 -56 1/2" AFF.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 391 Admin. - Men's Restroom 16.84A - Paper Towel Dispenser - Operating Height Mounting height of paper towel dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one paper towel dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one paper towel dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -53" AFF.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 392 Admin. - Men's Restroom Page 141 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.83 - Coat Hook - Height Where a coat hook is provided In an accessible stall, height of coat hook exceeds 48” AFF. 4.2.5 213.3.7; 308; 603.4 1117B.8 -75" AFF.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 394 Admin. - Men's Restroom 16.04 - Accessible Path of Travel Toilet room is not located on an accessible route of travel. 4.22.1 206.2.4; Advisory 206.2.4 1115B.1 -EC - Employee Common Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 396 Admin. - Women's Restroom 16.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand. OR They are not operable without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Twist-type locking mechanism.EC - Employee Common Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 397 Admin. - Women's Restroom 16.13B - Women's RR Geometric Symbol Signage - Circle Doorway leading to a women’s toilet room is not identified by a circle, 1/4" thick and 12” in diameter. OR Circle is provided, however it is accompanied by words in raised characters and Braille. (ADA and CBC Standards require a separate sign with raised characters and Braille mounted on the wall adjacent to the latch side of the door.) --1115B.6 -EC - Employee Common Use D - Minor Code Deviation 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 398 Admin. - Women's Restroom 16.15B - Room/Space Identification Signs (Visual/Tactile Signs) Sign designating the permanent room or space does not comply with ADAAG and CBC requirements for tactile signs. 4.30.1 216.2; Advisory 216.2; 703.1; 703.2; 703.5. 1117B.5 .1(1) -EC - Employee Common Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 399 Admin. - Women's Restroom Page 142 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.18A - ISA Accessible toilet room is not identified by an ISA. 4.1.3(16 )(b) 216.8 1117B.5 .1(3) -EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 400 Admin. - Women's Restroom 16.09A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6 404.2.4. 1; Table 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2; Fig. 11B-26 -8" to lavatory, pull side.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 401 Admin. - Women's Restroom 16.47A - WC Location from Sidewall The centerline of the WC is not 18” absolute from a wall or partition. 4.22.4 -1115B.4 .1(1) -20" from side wall.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 402 Admin. - Women's Restroom 16.48 - WC Seat Height The top of the WC seat is not between 17” and 19” AFF. 4.16.3; Fig. 29(b) 604.4 1115B.4 .1(4); Fig. 11B-1A -15 1/2" AFF.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 403 Admin. - Women's Restroom 16.53 - SC Dispenser Height Mounting height of seat cover dispenser's highest operable part exceeds 40" AFF. 4.22.7; 4.27.3; 4.2.5; 4.2.6 -1115B.8 .3 -44" AFF.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 404 Admin. - Women's Restroom Page 143 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.54A - Grab Bar Grab bar is not provided.4.17.6; Figs. 29 & 30 604.5; Advisory 604.5; 609.4 1115B.4 .1(3.1) & (3.2); Fig. 11B-1A -EC - Employee Common Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 405 Admin. - Women's Restroom 16.50 - TP Dispenser - Location - Pre- 2007 CBC Facility Location of the toilet paper dispenser does not comply with the Standard in effect at the time of construction. (The 2001 CBC required toilet tissue dispensers located on the wall within 12" of the front edge of the toilet seat, measured to the centerline of the dispenser; mounted below the grab bar; and centered at a min. height of 19" AFF.) 4.16.6; Fig. 29(b) 604.7; Advisory 604.7; Fig. 604.7 --37" from back wall.EC - Employee Common Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 406 Admin. - Women's Restroom 16.70 - Lavatories Lavatory does not comply with ADAAG and CBC requirements. (ADA Standards require at least one lavatory to be accessible. CBC Standards prior to August 1, 2009 required all lavatories to be accessible. Effective August 1, 2009, amended CBC Standards require at least 5% of lavatories, but not less than one lavatory, to be accessible.) 4.22.6 213.3.4; 606.1 1115B.4 .3 -Knee space not provided.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 407 Admin. - Women's Restroom 16.82A - Mirror Height - Max. 40" AFF Standard Mirror above accessible lavatory or countertop is mounted so the bottom edge of the reflective surface is not 40” max.. AFF. (ADA Standards require at least one mirror to be accessible; CBC Standards prior to August 1, 2009 required all mirrors to be accessible. Effective August 1, 2009, amended CBC Standards require all mirrors above accessible lavatories or countertops to be accessible.) 4.19.6; Fig. 31 213.3.5; 603.3; Advisory 603.3 1115B.8 .1 -54" AFF.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 408 Admin. - Women's Restroom Page 144 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.84A - Paper Towel Dispenser - Operating Height Mounting height of paper towel dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one paper towel dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one paper towel dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -52" AFF.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 409 Admin. - Women's Restroom 16.84C - Soap Dispenser - Operating Height Mounting height of soap dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one soap dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one soap dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -41" AFF.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 410 Admin. - Women's Restroom 16.83 - Coat Hook - Height Where a coat hook is provided In an accessible stall, height of coat hook exceeds 48” AFF. 4.2.5 213.3.7; 308; 603.4 1117B.8 -64" AFF.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 412 Admin. - Women's Restroom 16.01 - Toilet Rooms Toilet room does not comply with all applicable ADAAG and CBC accessibility requirements. 4.1.2(6) ; 4.1.3(11 ); 4.22.1 213.2; Advisory 213.2 1115B.1 -No accessible stall.EC - Employee Common Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 431 Admin. - Unisex Restrm. Page 145 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.09A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6 404.2.4. 1; Table 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2; Fig. 11B-26 -53 1/2" Latch pull side EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 432 Admin. - Unisex Restrm. 16.13C - Unisex RR Geometric Symbol Signage - Circle/Triangle Doorway leading to a unisex toilet room is not identified by a 12” circle, 1/4" with a 1/4" thick triangle superimposed and within the circle. OR Circle and triangle are provided, however they are accompanied by words in raised characters and Braille. (ADA and CBC Standards require a separate sign with raised characters and Braille mounted on the wall adjacent to the latch side of the door.) --1115B.6 -EC - Employee Common Use D - Minor Code Deviation 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 433 Admin. - Unisex Restrm. 16.15A - Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.30.1 216.2; 703.1; 703.2; 703.5 1117B.5 .1(1) -EC - Employee Common Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 434 Admin. - Unisex Restrm. 16.18A - ISA Accessible toilet room is not identified by an ISA. 4.1.3(16 )(b) 216.8 1117B.5 .1(3) -EC - Employee Common Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 435 Admin. - Unisex Restrm. Page 146 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.27A - 60” Wide Circle or T- Shaped Maneuvering Space The toilet room does not include an unobstructed turning space (a 60” diameter, 27" high circle or T-shaped space). (Note: The clear floor space of fixtures and controls, the accessible path of travel, and the turning space may overlap.) 4.22.3; Fig 3 304.3.2; Fig.304. 3.2; 603.2.1 1115B.3 .1(1); 1115B.3 .2(1) -EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 436 Admin. - Unisex Restrm. 16.72 - Lavatory Apron Clearance Lavatory does not provide accessible apron clearance (i.e. at least 29” clearance from the floor to the bottom of the apron). 4.19.2; Fig. 31 606.3 1115B.4 .3(2); Fig 11B- 1D -27 1/2" high EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 437 Admin. - Unisex Restrm. 16.73 - Lavatory Knee Clearance Lavatory does not provide accessible knee clearance (i.e. at least 27” clearance from the floor to the underside of the lavatory, extending 8” min.. measured from the front edge underneath the lavatory back towards the wall). 4.19.2; Fig. 31 306.3; Fig. 306.3 1115B.4 .3(2); Fig 11B- 1D -25 1/4" high EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 438 Admin. - Unisex Restrm. 16.78 - Pipe Insulation at Lavatory Drainpipes and hot water pipes are not insulated to protect against contact. 4.19.4 606.5 1115B.4 .3(4) -EC - Employee Common Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 439 Admin. - Unisex Restrm. 16.80 - Faucet Operation at Lavatory The faucet is not compliant. (Accessible faucets shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.19.5; 4.27.4 309.4; 606.4 1115B.4 .3(1) -EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 440 Admin. - Unisex Restrm. Page 147 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.82A - Mirror Height - Max. 40" AFF Standard Mirror above accessible lavatory or countertop is mounted so the bottom edge of the reflective surface is not 40” max.. AFF. (ADA Standards require at least one mirror to be accessible; CBC Standards prior to August 1, 2009 required all mirrors to be accessible. Effective August 1, 2009, amended CBC Standards require all mirrors above accessible lavatories or countertops to be accessible.) 4.19.6; Fig. 31 213.3.5; 603.3; Advisory 603.3 1115B.8 .1 -52 1/2" high EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 441 Admin. - Unisex Restrm. 16.83 - Coat Hook - Height Where a coat hook is provided In an accessible stall, height of coat hook exceeds 48” AFF. 4.2.5 213.3.7; 308; 603.4 1117B.8 -57" high EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 442 Admin. - Unisex Restrm. 16.84A - Paper Towel Dispenser - Operating Height Mounting height of paper towel dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one paper towel dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one paper towel dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -44" high EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 443 Admin. - Unisex Restrm. 16.84C - Soap Dispenser - Operating Height Mounting height of soap dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one soap dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one soap dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -41" high EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 444 Admin. - Unisex Restrm. Page 148 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.66 - Clear Floor Space at Urinal There is no clear floor space at least 30” x 48” to allow a forward approach to the urinal. 4.18.3 605.3; 305.3 1115B.4 .2(3); 1118B.4 (1); Fig. 11B-5A -43" deep clr floor space EC - Employee Common Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 445 Admin. - Unisex Restrm. 16.65D - Urinal Flush Controls - Height Height of urinal flush controls exceeds 44" AFF.4.18.4 605.4; 604.6; Advisory 604.6 1115B.4 .2(2) -52" high EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 446 Admin. - Unisex Restrm. 16.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand. OR They are not operable without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Twist-type locking mechanism.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 546 Admin. - Men's Restroom 16.13A - Men's RR Geometric Symbol Signage - Triangle Doorway leading to a men’s toilet room is not identified by an equilateral triangle 1/4" thick with edges 12” long. OR Equilateral triangle is provided, however it is accompanied by words in raised characters and Braille. (ADA and CBC Standards require a separate sign with raised characters and Braille mounted on the wall adjacent to the latch side of the door.) --1115B.6 -PV - Public/Visitor Use D - Minor Code Deviation 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 547 Admin. - Men's Restroom 16.15A - Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.30.1 216.2; 703.1; 703.2; 703.5 1117B.5 .1(1) -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 548 Admin. - Men's Restroom 16.18A - ISA Accessible toilet room is not identified by an ISA. 4.1.3(16 )(b) 216.8 1117B.5 .1(3) -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 549 Admin. - Men's Restroom Page 149 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.47A - WC Location from Sidewall The centerline of the WC is not 18” absolute from a wall or partition. 4.22.4 -1115B.4 .1(1) -19 3/4" from side wall.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 550 Admin. - Men's Restroom 16.48 - WC Seat Height The top of the WC seat is not between 17” and 19” AFF. 4.16.3; Fig. 29(b) 604.4 1115B.4 .1(4); Fig. 11B-1A -15 1/2" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 551 Admin. - Men's Restroom 16.53 - SC Dispenser Height Mounting height of seat cover dispenser's highest operable part exceeds 40" AFF. 4.22.7; 4.27.3; 4.2.5; 4.2.6 -1115B.8 .3 -46" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 552 Admin. - Men's Restroom 16.54A - Grab Bar Grab bar is not provided.4.17.6; Figs. 29 & 30 604.5; Advisory 604.5; 609.4 1115B.4 .1(3.1) & (3.2); Fig. 11B-1A -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 553 Admin. - Men's Restroom 16.50 - TP Dispenser - Location - Pre- 2007 CBC Facility Location of the toilet paper dispenser does not comply with the Standard in effect at the time of construction. (The 2001 CBC required toilet tissue dispensers located on the wall within 12" of the front edge of the toilet seat, measured to the centerline of the dispenser; mounted below the grab bar; and centered at a min. height of 19" AFF.) 4.16.6; Fig. 29(b) 604.7; Advisory 604.7; Fig. 604.7 --39" from back wall.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 554 Admin. - Men's Restroom Page 150 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.70 - Lavatories Lavatory does not comply with ADAAG and CBC requirements. (ADA Standards require at least one lavatory to be accessible. CBC Standards prior to August 1, 2009 required all lavatories to be accessible. Effective August 1, 2009, amended CBC Standards require at least 5% of lavatories, but not less than one lavatory, to be accessible.) 4.22.6 213.3.4; 606.1 1115B.4 .3 -Knee space not provided.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 555 Admin. - Men's Restroom 16.80 - Faucet Operation at Lavatory The faucet is not compliant. (Accessible faucets shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.19.5; 4.27.4 309.4; 606.4 1115B.4 .3(1) -Twist-type faucet controls.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 556 Admin. - Men's Restroom 16.82A - Mirror Height - Max. 40" AFF Standard Mirror above accessible lavatory or countertop is mounted so the bottom edge of the reflective surface is not 40” max.. AFF. (ADA Standards require at least one mirror to be accessible; CBC Standards prior to August 1, 2009 required all mirrors to be accessible. Effective August 1, 2009, amended CBC Standards require all mirrors above accessible lavatories or countertops to be accessible.) 4.19.6; Fig. 31 213.3.5; 603.3; Advisory 603.3 1115B.8 .1 -46" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 557 Admin. - Men's Restroom 16.84A - Paper Towel Dispenser - Operating Height Mounting height of paper towel dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one paper towel dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one paper towel dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -49" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 558 Admin. - Men's Restroom Page 151 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.83 - Coat Hook - Height Where a coat hook is provided In an accessible stall, height of coat hook exceeds 48” AFF. 4.2.5 213.3.7; 308; 603.4 1117B.8 -Coat hook at 65" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 560 Admin. - Men's Restroom 16.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand. OR They are not operable without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Twist-type locking mechanism.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 562 Admin. - Women's Restroom 16.13B - Women's RR Geometric Symbol Signage - Circle Doorway leading to a women’s toilet room is not identified by a circle, 1/4" thick and 12” in diameter. OR Circle is provided, however it is accompanied by words in raised characters and Braille. (ADA and CBC Standards require a separate sign with raised characters and Braille mounted on the wall adjacent to the latch side of the door.) --1115B.6 -PV - Public/Visitor Use D - Minor Code Deviation 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 563 Admin. - Women's Restroom 16.15A - Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.30.1 216.2; 703.1; 703.2; 703.5 1117B.5 .1(1) -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 564 Admin. - Women's Restroom 16.18A - ISA Accessible toilet room is not identified by an ISA. 4.1.3(16 )(b) 216.8 1117B.5 .1(3) -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 565 Admin. - Women's Restroom 16.47A - WC Location from Sidewall The centerline of the WC is not 18” absolute from a wall or partition. 4.22.4 -1115B.4 .1(1) -19" from side wall.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 566 Admin. - Women's Restroom Page 152 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.48 - WC Seat Height The top of the WC seat is not between 17” and 19” AFF. 4.16.3; Fig. 29(b) 604.4 1115B.4 .1(4); Fig. 11B-1A -15 1/2" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 567 Admin. - Women's Restroom 16.53 - SC Dispenser Height Mounting height of seat cover dispenser's highest operable part exceeds 40" AFF. 4.22.7; 4.27.3; 4.2.5; 4.2.6 -1115B.8 .3 -46" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 568 Admin. - Women's Restroom 16.54A - Grab Bar Grab bar is not provided.4.17.6; Figs. 29 & 30 604.5; Advisory 604.5; 609.4 1115B.4 .1(3.1) & (3.2); Fig. 11B-1A -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 569 Admin. - Women's Restroom 16.49B - WC Flush Controls - Location Flush controls are not located on the wide side of the WC where the clear floor space is provided. 4.16.5 604.6; Advisory 604.6 1115B.4 .1(5); Fig. 11B-1A -Flush valve not on wide side.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 570 Admin. - Women's Restroom 16.50 - TP Dispenser - Location - Pre- 2007 CBC Facility Location of the toilet paper dispenser does not comply with the Standard in effect at the time of construction. (The 2001 CBC required toilet tissue dispensers located on the wall within 12" of the front edge of the toilet seat, measured to the centerline of the dispenser; mounted below the grab bar; and centered at a min. height of 19" AFF.) 4.16.6; Fig. 29(b) 604.7; Advisory 604.7; Fig. 604.7 --39" from back wall.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 571 Admin. - Women's Restroom Page 153 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.70 - Lavatories Lavatory does not comply with ADAAG and CBC requirements. (ADA Standards require at least one lavatory to be accessible. CBC Standards prior to August 1, 2009 required all lavatories to be accessible. Effective August 1, 2009, amended CBC Standards require at least 5% of lavatories, but not less than one lavatory, to be accessible.) 4.22.6 213.3.4; 606.1 1115B.4 .3 -Knee space not provided.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 572 Admin. - Women's Restroom 16.80 - Faucet Operation at Lavatory The faucet is not compliant. (Accessible faucets shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.19.5; 4.27.4 309.4; 606.4 1115B.4 .3(1) -Twist-type faucet controls.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 573 Admin. - Women's Restroom 16.82A - Mirror Height - Max. 40" AFF Standard Mirror above accessible lavatory or countertop is mounted so the bottom edge of the reflective surface is not 40” max.. AFF. (ADA Standards require at least one mirror to be accessible; CBC Standards prior to August 1, 2009 required all mirrors to be accessible. Effective August 1, 2009, amended CBC Standards require all mirrors above accessible lavatories or countertops to be accessible.) 4.19.6; Fig. 31 213.3.5; 603.3; Advisory 603.3 1115B.8 .1 -46" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 574 Admin. - Women's Restroom 16.84A - Paper Towel Dispenser - Operating Height Mounting height of paper towel dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one paper towel dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one paper towel dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -49" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 575 Admin. - Women's Restroom Page 154 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.83 - Coat Hook - Height Where a coat hook is provided In an accessible stall, height of coat hook exceeds 48” AFF. 4.2.5 213.3.7; 308; 603.4 1117B.8 -65" AFF.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 577 Admin. - Women's Restroom 16.27A - 60” Wide Circle or T- Shaped Maneuvering Space The toilet room does not include an unobstructed turning space (a 60” diameter, 27" high circle or T-shaped space). (Note: The clear floor space of fixtures and controls, the accessible path of travel, and the turning space may overlap.) 4.22.3; Fig 3 304.3.2; Fig.304. 3.2; 603.2.1 1115B.3 .1(1); 1115B.3 .2(1) -Approx. 40" diameter circle.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 580 Admin. - Women's Restroom 16.84A - Paper Towel Dispenser - Operating Height Mounting height of paper towel dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one paper towel dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one paper towel dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -54" AFF.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 598 Admin. - Break Room 16.84A - Paper Towel Dispenser - Operating Height Mounting height of paper towel dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one paper towel dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one paper towel dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -51" AFF.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 682 Admin. - Break Room Page 155 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.09A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6 404.2.4. 1; Table 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2; Fig. 11B-26 -7" to CMU wall at pull side, & 47" landing at pull side. EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 687 Admin. - Unisex Restroom 16.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand. OR They are not operable without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Twist-type locking mechanism.EC - Employee Common Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 688 Admin. - Unisex Restroom 16.13C - Unisex RR Geometric Symbol Signage - Circle/Triangle Doorway leading to a unisex toilet room is not identified by a 12” circle, 1/4" with a 1/4" thick triangle superimposed and within the circle. OR Circle and triangle are provided, however they are accompanied by words in raised characters and Braille. (ADA and CBC Standards require a separate sign with raised characters and Braille mounted on the wall adjacent to the latch side of the door.) --1115B.6 -EC - Employee Common Use D - Minor Code Deviation 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 689 Admin. - Unisex Restroom 16.15A - Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.30.1 216.2; 703.1; 703.2; 703.5 1117B.5 .1(1) -EC - Employee Common Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 690 Admin. - Unisex Restroom Page 156 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.18A - ISA Accessible toilet room is not identified by an ISA. 4.1.3(16 )(b) 216.8 1117B.5 .1(3) -EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 691 Admin. - Unisex Restroom 16.41 - 32" Wide Standard - Side Transfer Space The clear space from a wall at one side of the WC is less than 32” wide. --1115B.4 .1(1); Fig. 11B-1B -18" to non-fixed furniture.EC - Employee Common Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 692 Admin. - Unisex Restroom 16.48 - WC Seat Height The top of the WC seat is not between 17” and 19” AFF. 4.16.3; Fig. 29(b) 604.4 1115B.4 .1(4); Fig. 11B-1A -16" AFF.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 693 Admin. - Unisex Restroom 16.50 - TP Dispenser - Location - Pre- 2007 CBC Facility Location of the toilet paper dispenser does not comply with the Standard in effect at the time of construction. (The 2001 CBC required toilet tissue dispensers located on the wall within 12" of the front edge of the toilet seat, measured to the centerline of the dispenser; mounted below the grab bar; and centered at a min. height of 19" AFF.) 4.16.6; Fig. 29(b) 604.7; Advisory 604.7; Fig. 604.7 --40 1/2" from back wall.EC - Employee Common Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 694 Admin. - Unisex Restroom 16.53 - SC Dispenser Height Mounting height of seat cover dispenser's highest operable part exceeds 40" AFF. 4.22.7; 4.27.3; 4.2.5; 4.2.6 -1115B.8 .3 -56" AFF.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 695 Admin. - Unisex Restroom 16.54A - Grab Bar Grab bar is not provided.4.17.6; Figs. 29 & 30 604.5; Advisory 604.5; 609.4 1115B.4 .1(3.1) & (3.2); Fig. 11B-1A -Rear grab bar not provided.EC - Employee Common Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 696 Admin. - Unisex Restroom Page 157 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.54B - Side Grab Bar Length Side grab bar is less than 42” long. (ADA Standards require the side grab bar for WC's not located in stalls to be 42" long min..; ADA Standards require the side grab bar for WC's located in stalls to be 40" to 42" long min..; CBC Standards require the side grab bar to be 42" long min..) 4.17.6; Figs. 29 & 30 604.5; Advisory 604.5; 604.5.1; Fig. 604.5.1; 609.4 1115B.4 .1(3.1); Fig. 11B-1A -37" long.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 697 Admin. - Unisex Restroom 16.55A - Side Grab Bar Height Side grab bar is not centered at 33" AFF. (ADA Standards require side grab bars to be centered from 33" to 36" AFF; CBC Standards require side grab bars to be centered at 33" AFF.) 4.17.6; Figs. 29 & 30 604.5; Advisory 604.5; 604.5.2; Fig. 604.5.2; 609.4 1115B.4 .1(3.1); Fig. 11B-1A -29" AFF.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 698 Admin. - Unisex Restroom 16.70 - Lavatories Lavatory does not comply with ADAAG and CBC requirements. (ADA Standards require at least one lavatory to be accessible. CBC Standards prior to August 1, 2009 required all lavatories to be accessible. Effective August 1, 2009, amended CBC Standards require at least 5% of lavatories, but not less than one lavatory, to be accessible.) 4.22.6 213.3.4; 606.1 1115B.4 .3 -EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 699 Admin. - Unisex Restroom 16.80 - Faucet Operation at Lavatory The faucet is not compliant. (Accessible faucets shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.19.5; 4.27.4 309.4; 606.4 1115B.4 .3(1) -EC - Employee Common Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 700 Admin. - Unisex Restroom Page 158 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 02B - City Hall BuildingsReporting: 753 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.82A - Mirror Height - Max. 40" AFF Standard Mirror above accessible lavatory or countertop is mounted so the bottom edge of the reflective surface is not 40” max.. AFF. (ADA Standards require at least one mirror to be accessible; CBC Standards prior to August 1, 2009 required all mirrors to be accessible. Effective August 1, 2009, amended CBC Standards require all mirrors above accessible lavatories or countertops to be accessible.) 4.19.6; Fig. 31 213.3.5; 603.3; Advisory 603.3 1115B.8 .1 -52 1/2" AFF.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 701 Admin. - Unisex Restroom 16.84A - Paper Towel Dispenser - Operating Height Mounting height of paper towel dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one paper towel dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one paper towel dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -52 1/2" AFF.EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 702 Admin. - Unisex Restroom 174Number of Key Notes for Group 16 - Toilet Facilities: 753Number of Key Notes for Facility 02B - City Hall Buildings: 753Total Number of Key Notes for All Groups: Page 159 of 159 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA