Loading...
Area 7 Bus Stops_ComplianceReport_20130509-115910Facility ID # Area 7 Bus StopsReporting: 29 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 02 - Passenger Loading Zone Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 02.11B - Bus Stop Pad and Accessible Route Bus stop pad is not connected to an accessible route. 10.2.1 810.2.3 1121B.1 No accessible route to bus stop (planters). PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 1 Palos Verdes Dr. S/ Ocean Trail Dr. (SB) 02.11A - Bus Stop Pad Size Bus stop pad does not measure 8’ long (measured from the curb or vehicle roadway edge) by 5’ wide (measured parallel to the vehicle roadway). 10.2.1 810.2.2 1121B.1 Bus pad 3'-6" long by 5' wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 2 Palos Verdes Dr. S/ Ocean Trail Dr. (SB) 02.12A - Bus Stop Pad Slope Parallel to Roadway Bus stop pad is not at the same slope as the roadway in the direction parallel to the roadway. 10.2.1 810.2.4 1121B.2 .1 3.9% RS at bus pad , 3.8% RS at the road. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 3 Palos Verdes Dr. S/ Ocean Trail Dr. (SB) 02.12B - Bus Stop Pad Slope Perpendicular to Roadway Bus stop pad slope perpendicular to the roadway exceeds 2%. 10.2.1 810.2.4 1121B.2 .1 4.1% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 4 Palos Verdes Dr. S/ Ocean Trail Dr. (SB) 02.11B - Bus Stop Pad and Accessible Route Bus stop pad is not connected to an accessible route. 10.2.1 810.2.3 1121B.1 No accessible route to bus stop (grass). PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 5 Ganado Dr./ Flowerridge Dr. (SB) 02.11A - Bus Stop Pad Size Bus stop pad does not measure 8’ long (measured from the curb or vehicle roadway edge) by 5’ wide (measured parallel to the vehicle roadway). 10.2.1 810.2.2 1121B.1 Bus pad 3'-11" long by 5' wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 6 Ganado Dr./ Flowerridge Dr. (SB) 02.11A - Bus Stop Pad Size Bus stop pad does not measure 8’ long (measured from the curb or vehicle roadway edge) by 5’ wide (measured parallel to the vehicle roadway). 10.2.1 810.2.2 1121B.1 None provided.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 7 Ganado Dr./ Flowerridge Dr. (NB) Page 1 of 5 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # Area 7 Bus StopsReporting: 29 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 02 - Passenger Loading Zone Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 02.11B - Bus Stop Pad and Accessible Route Bus stop pad is not connected to an accessible route. 10.2.1 810.2.3 1121B.1 No accessible route to bus stop. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 8 Ganado Dr./ Flowerridge Dr. (NB) 02.11B - Bus Stop Pad and Accessible Route Bus stop pad is not connected to an accessible route. 10.2.1 810.2.3 1121B.1 No accessible route to bus stop (shrubs). PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 9 Ganado Dr./ Abrazo Dr. (SB) 02.11A - Bus Stop Pad Size Bus stop pad does not measure 8’ long (measured from the curb or vehicle roadway edge) by 5’ wide (measured parallel to the vehicle roadway). 10.2.1 810.2.2 1121B.1 Bus pad 4' long by 5' wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 10 Ganado Dr./ Abrazo Dr. (SB) 02.12A - Bus Stop Pad Slope Parallel to Roadway Bus stop pad is not at the same slope as the roadway in the direction parallel to the roadway. 10.2.1 810.2.4 1121B.2 .1 4.6% RS at bus pad , 5.2% RS at the road. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 11 Ganado Dr./ Abrazo Dr. (SB) 02.12B - Bus Stop Pad Slope Perpendicular to Roadway Bus stop pad slope perpendicular to the roadway exceeds 2%. 10.2.1 810.2.4 1121B.2 .1 2.1% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 12 Ganado Dr./ Abrazo Dr. (SB) 02.11A - Bus Stop Pad Size Bus stop pad does not measure 8’ long (measured from the curb or vehicle roadway edge) by 5’ wide (measured parallel to the vehicle roadway). 10.2.1 810.2.2 1121B.1 3'-10" long by 5' wide Bus pad PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 13 Palos Verdes Dr. E/ Marymount College (NB) 02.11B - Bus Stop Pad and Accessible Route Bus stop pad is not connected to an accessible route. 10.2.1 810.2.3 1121B.1 No accessible route to bus stop (grass). PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 14 Palos Verdes Dr. E/ Marymount College (NB) Page 2 of 5 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # Area 7 Bus StopsReporting: 29 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 02 - Passenger Loading Zone Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 02.12B - Bus Stop Pad Slope Perpendicular to Roadway Bus stop pad slope perpendicular to the roadway exceeds 2%. 10.2.1 810.2.4 1121B.2 .1 7.5% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 15 Palos Verdes Dr. E/ Marymount College (NB) 02.11A - Bus Stop Pad Size Bus stop pad does not measure 8’ long (measured from the curb or vehicle roadway edge) by 5’ wide (measured parallel to the vehicle roadway). 10.2.1 810.2.2 1121B.1 None provided.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 16 Palos Verdes Dr. E/ La Vista Verde Dr. (NB) 02.11B - Bus Stop Pad and Accessible Route Bus stop pad is not connected to an accessible route. 10.2.1 810.2.3 1121B.1 No accessible route to bus stop. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 17 Palos Verdes Dr. E/ La Vista Verde Dr. (NB) 02.11A - Bus Stop Pad Size Bus stop pad does not measure 8’ long (measured from the curb or vehicle roadway edge) by 5’ wide (measured parallel to the vehicle roadway). 10.2.1 810.2.2 1121B.1 None provided.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 18 Palos Verdes Dr. E/ La Vista Verde Dr. (SB) 02.11B - Bus Stop Pad and Accessible Route Bus stop pad is not connected to an accessible route. 10.2.1 810.2.3 1121B.1 No accessible route to bus stop. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 19 Palos Verdes Dr. E/ La Vista Verde Dr. (SB) 02.11A - Bus Stop Pad Size Bus stop pad does not measure 8’ long (measured from the curb or vehicle roadway edge) by 5’ wide (measured parallel to the vehicle roadway). 10.2.1 810.2.2 1121B.1 Not provided.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 20 Ganado Dr. Switchback (SB) 02.11B - Bus Stop Pad and Accessible Route Bus stop pad is not connected to an accessible route. 10.2.1 810.2.3 1121B.1 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 21 Ganado Dr. Switchback (SB) Page 3 of 5 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # Area 7 Bus StopsReporting: 29 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 02 - Passenger Loading Zone Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 02.12A - Bus Stop Pad Slope Parallel to Roadway Bus stop pad is not at the same slope as the roadway in the direction parallel to the roadway. 10.2.1 810.2.4 1121B.2 .1 12% slope parallel to road.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 22 Ganado Dr. Switchback (SB) 02.12B - Bus Stop Pad Slope Perpendicular to Roadway Bus stop pad slope perpendicular to the roadway exceeds 2%. 10.2.1 810.2.4 1121B.2 .1 3.7% slope perpendicular to road. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 23 Ganado Dr. Switchback (SB) 02.11A - Bus Stop Pad Size Bus stop pad does not measure 8’ long (measured from the curb or vehicle roadway edge) by 5’ wide (measured parallel to the vehicle roadway). 10.2.1 810.2.2 1121B.1 Not Provided.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 24 Ganado Dr. Switchback (NB) 02.11B - Bus Stop Pad and Accessible Route Bus stop pad is not connected to an accessible route. 10.2.1 810.2.3 1121B.1 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 25 Ganado Dr. Switchback (NB) 02.11A - Bus Stop Pad Size Bus stop pad does not measure 8’ long (measured from the curb or vehicle roadway edge) by 5’ wide (measured parallel to the vehicle roadway). 10.2.1 810.2.2 1121B.1 Not provided.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 26 Ganado Dr. Switchback (SB) 02.11B - Bus Stop Pad and Accessible Route Bus stop pad is not connected to an accessible route. 10.2.1 810.2.3 1121B.1 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 27 Ganado Dr. Switchback (SB) 02.12A - Bus Stop Pad Slope Parallel to Roadway Bus stop pad is not at the same slope as the roadway in the direction parallel to the roadway. 10.2.1 810.2.4 1121B.2 .1 1.2% slope parallel to road.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 28 Ganado Dr. Switchback (SB) Page 4 of 5 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # Area 7 Bus StopsReporting: 29 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 02 - Passenger Loading Zone Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 02.12B - Bus Stop Pad Slope Perpendicular to Roadway Bus stop pad slope perpendicular to the roadway exceeds 2%. 10.2.1 810.2.4 1121B.2 .1 3.5% slope perpendicular to road. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 29 Ganado Dr. Switchback (SB) 29Number of Key Notes for Group 02 - Passenger Loading Zone: 29Number of Key Notes for Facility Area 7 Bus Stops: 29Total Number of Key Notes for All Groups: Page 5 of 5 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA