Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Area 5 Bus Stops_ComplianceReport_20130509-115712
Facility ID # Area 5 Bus StopsReporting: 60 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 02 - Passenger Loading Zone Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 02.11A - Bus Stop Pad Size Bus stop pad does not measure 8’ long (measured from the curb or vehicle roadway edge) by 5’ wide (measured parallel to the vehicle roadway). 10.2.1 810.2.2 1121B.1 Bus pad3'-7" long x 5' wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 1 Palos Verdes Dr. W/ Berry Hill Dr. (NB) 02.12A - Bus Stop Pad Slope Parallel to Roadway Bus stop pad is not at the same slope as the roadway in the direction parallel to the roadway. 10.2.1 810.2.4 1121B.2 .1 2.2% RS at bus pad , 2.0% RS at the road. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 2 Palos Verdes Dr. W/ Berry Hill Dr. (NB) 02.12B - Bus Stop Pad Slope Perpendicular to Roadway Bus stop pad slope perpendicular to the roadway exceeds 2%. 10.2.1 810.2.4 1121B.2 .1 2.3% CS at concrete & 4.9% CS at DG. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 3 Palos Verdes Dr. W/ Calle Entradero (SB) 02.11A - Bus Stop Pad Size Bus stop pad does not measure 8’ long (measured from the curb or vehicle roadway edge) by 5’ wide (measured parallel to the vehicle roadway). 10.2.1 810.2.2 1121B.1 Bus pad 6'-5" long x 5' wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 4 Palos Verdes Dr. W/ Calle Entradero (SB) 02.17 - Other - Passenger Loading Zones See Additional Comments ---Bench (16" high seat, 14" deep seat, 14" high back support, 0" WC shoulder alignment). PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 1 - Access into Facilities (28 CFR 36.304(c)(1)) 5 Palos Verdes Dr. W/ Rue Beaupre (NB) 02.11A - Bus Stop Pad Size Bus stop pad does not measure 8’ long (measured from the curb or vehicle roadway edge) by 5’ wide (measured parallel to the vehicle roadway). 10.2.1 810.2.2 1121B.1 Bus pad 6'-1" long by 5' wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 6 Palos Verdes Dr. W/ Rue Beaupre (NB) 02.12B - Bus Stop Pad Slope Perpendicular to Roadway Bus stop pad slope perpendicular to the roadway exceeds 2%. 10.2.1 810.2.4 1121B.2 .1 3.1% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 7 Palos Verdes Dr. W/ Rue Beaupre (NB) Page 1 of 9 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # Area 5 Bus StopsReporting: 60 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 02 - Passenger Loading Zone Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 02.11A - Bus Stop Pad Size Bus stop pad does not measure 8’ long (measured from the curb or vehicle roadway edge) by 5’ wide (measured parallel to the vehicle roadway). 10.2.1 810.2.2 1121B.1 Bus pad 5' long by 5' wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 8 Palos Verdes Dr. W/ Rue Beaupre (SB) 02.12B - Bus Stop Pad Slope Perpendicular to Roadway Bus stop pad slope perpendicular to the roadway exceeds 2%. 10.2.1 810.2.4 1121B.2 .1 4.7% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 9 Palos Verdes Dr. W/ Rue Beaupre (SB) 02.12A - Bus Stop Pad Slope Parallel to Roadway Bus stop pad is not at the same slope as the roadway in the direction parallel to the roadway. 10.2.1 810.2.4 1121B.2 .1 3.0% RS at bus pad , 1.5% RS at the road. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 10 Palos Verdes Dr. W/ Rue Beaupre (SB) 02.17 - Other - Passenger Loading Zones See Additional Comments ---Bench (16" high seat, 11" deep seat, 14 1/2" high back support, hazard condition, no 12" shoulder alignment). PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 1 - Access into Facilities (28 CFR 36.304(c)(1)) 11 Hawthorne Blvd./ Palos Verdes Dr. W (NB) 02.13A - Bus Stop Shelter - Clear Floor Area Clear floor area of 30” by 48” is not completely within the shelter. 10.2.1(2 ) 810.3 1121B.2 .1 No WC space provided within the shelter. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 12 Hawthorne Blvd./ Palos Verdes Dr. W (NB) 02.12B - Bus Stop Pad Slope Perpendicular to Roadway Bus stop pad slope perpendicular to the roadway exceeds 2%. 10.2.1 810.2.4 1121B.2 .1 2.7% to 3.5% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 13 Hawthorne Blvd./ Palos Verdes Dr. W (NB) 02.17 - Other - Passenger Loading Zones See Additional Comments ---Bench (16" high seat, 15 3/4" deep seat, 15" high back support). PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 1 - Access into Facilities (28 CFR 36.304(c)(1)) 14 Palos Verdes Dr. W/ Hawthorne Blvd. (SB) Page 2 of 9 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # Area 5 Bus StopsReporting: 60 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 02 - Passenger Loading Zone Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 02.12B - Bus Stop Pad Slope Perpendicular to Roadway Bus stop pad slope perpendicular to the roadway exceeds 2%. 10.2.1 810.2.4 1121B.2 .1 4.2% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 15 Palos Verdes Dr. W/ Hawthorne Blvd. (SB) 02.11A - Bus Stop Pad Size Bus stop pad does not measure 8’ long (measured from the curb or vehicle roadway edge) by 5’ wide (measured parallel to the vehicle roadway). 10.2.1 810.2.2 1121B.1 Bus pad 6' long by 5' wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 16 Palos Verdes Dr. W/ Hawthorne Blvd. (SB) 02.17 - Other - Passenger Loading Zones See Additional Comments ---Uneven surface.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 17 Palos Verdes Dr. W/ Hawthorne Blvd. (NB) 02.11B - Bus Stop Pad and Accessible Route Bus stop pad is not connected to an accessible route. 10.2.1 810.2.3 1121B.1 No accessible route to bus stop. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 18 Hawthorne Blvd./ City Hall (NB) 02.11A - Bus Stop Pad Size Bus stop pad does not measure 8’ long (measured from the curb or vehicle roadway edge) by 5’ wide (measured parallel to the vehicle roadway). 10.2.1 810.2.2 1121B.1 bus pad 5'-6" long by 5' wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 19 Hawthorne Blvd./ City Hall (NB) 02.12A - Bus Stop Pad Slope Parallel to Roadway Bus stop pad is not at the same slope as the roadway in the direction parallel to the roadway. 10.2.1 810.2.4 1121B.2 .1 2.3% to 6.7% RS at bus pad, 2.4% to 4.9% RS at the road. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 20 Hawthorne Blvd./ City Hall (NB) 02.12B - Bus Stop Pad Slope Perpendicular to Roadway Bus stop pad slope perpendicular to the roadway exceeds 2%. 10.2.1 810.2.4 1121B.2 .1 4.1% to 5.5% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 21 Hawthorne Blvd./ City Hall (NB) Page 3 of 9 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # Area 5 Bus StopsReporting: 60 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 02 - Passenger Loading Zone Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 02.11A - Bus Stop Pad Size Bus stop pad does not measure 8’ long (measured from the curb or vehicle roadway edge) by 5’ wide (measured parallel to the vehicle roadway). 10.2.1 810.2.2 1121B.1 Bus pad 6' long by 5' wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 22 Hawthorne Blvd./ Via Rivera (SB) 02.12B - Bus Stop Pad Slope Perpendicular to Roadway Bus stop pad slope perpendicular to the roadway exceeds 2%. 10.2.1 810.2.4 1121B.2 .1 3.9% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 23 Hawthorne Blvd./ Via Rivera (SB) 02.11B - Bus Stop Pad and Accessible Route Bus stop pad is not connected to an accessible route. 10.2.1 810.2.3 1121B.1 No accessible route to bus stop. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 24 Hawthorne Blvd./ Salvation Army (SB) 02.12A - Bus Stop Pad Slope Parallel to Roadway Bus stop pad is not at the same slope as the roadway in the direction parallel to the roadway. 10.2.1 810.2.4 1121B.2 .1 3.9% to 5.2% RS at bus pad, 7.0% RS at the road. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 25 Hawthorne Blvd./ Salvation Army (SB) 02.12B - Bus Stop Pad Slope Perpendicular to Roadway Bus stop pad slope perpendicular to the roadway exceeds 2%. 10.2.1 810.2.4 1121B.2 .1 3.9% to 4.5% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 26 Hawthorne Blvd./ Salvation Army (SB) 02.11A - Bus Stop Pad Size Bus stop pad does not measure 8’ long (measured from the curb or vehicle roadway edge) by 5’ wide (measured parallel to the vehicle roadway). 10.2.1 810.2.2 1121B.1 Bus pad 6'-6" long by 5' wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 27 Hawthorne Blvd./ Salvation Army (SB) 02.17 - Other - Passenger Loading Zones See Additional Comments ---Bench ( 16 1/2" high seat, 15 1/2" deep seat, 17 1/2" high back support). PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 1 - Access into Facilities (28 CFR 36.304(c)(1)) 28 Hawthorne Blvd./ Salvation Army (NB) Page 4 of 9 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # Area 5 Bus StopsReporting: 60 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 02 - Passenger Loading Zone Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 02.13A - Bus Stop Shelter - Clear Floor Area Clear floor area of 30” by 48” is not completely within the shelter. 10.2.1(2 ) 810.3 1121B.2 .1 No WC space provided within the shelter. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 29 Hawthorne Blvd./ Salvation Army (NB) 02.11B - Bus Stop Pad and Accessible Route Bus stop pad is not connected to an accessible route. 10.2.1 810.2.3 1121B.1 No accessible route to bus pad.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 30 Hawthorne Blvd./ Salvation Army (NB) 02.12B - Bus Stop Pad Slope Perpendicular to Roadway Bus stop pad slope perpendicular to the roadway exceeds 2%. 10.2.1 810.2.4 1121B.2 .1 7.1% to 8.3% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 31 Hawthorne Blvd./ Salvation Army (NB) 02.17 - Other - Passenger Loading Zones See Additional Comments ---Bench ( 16" high seat, 14" deep seat, 15" high back support). PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 1 - Access into Facilities (28 CFR 36.304(c)(1)) 32 Hawthorne Blvd./ Vallon Dr. (NB) 02.12A - Bus Stop Pad Slope Parallel to Roadway Bus stop pad is not at the same slope as the roadway in the direction parallel to the roadway. 10.2.1 810.2.4 1121B.2 .1 7.3% to 10.6 RS at bus pad, 5.6% to 7.0% RS at the road. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 33 Hawthorne Blvd./ Vallon Dr. (NB) 02.12B - Bus Stop Pad Slope Perpendicular to Roadway Bus stop pad slope perpendicular to the roadway exceeds 2%. 10.2.1 810.2.4 1121B.2 .1 3.0% to 5.0% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 34 Hawthorne Blvd./ Vallon Dr. (NB) 02.11A - Bus Stop Pad Size Bus stop pad does not measure 8’ long (measured from the curb or vehicle roadway edge) by 5’ wide (measured parallel to the vehicle roadway). 10.2.1 810.2.2 1121B.1 Bus pad 6' long by 5' wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 35 Hawthorne Blvd./ Vallon Dr. (NB) Page 5 of 9 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # Area 5 Bus StopsReporting: 60 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 02 - Passenger Loading Zone Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 02.11A - Bus Stop Pad Size Bus stop pad does not measure 8’ long (measured from the curb or vehicle roadway edge) by 5’ wide (measured parallel to the vehicle roadway). 10.2.1 810.2.2 1121B.1 Bus pad 7'-5" long by 5' wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 36 Hawthorne Blvd./ Vallon Dr. (SB) 02.12A - Bus Stop Pad Slope Parallel to Roadway Bus stop pad is not at the same slope as the roadway in the direction parallel to the roadway. 10.2.1 810.2.4 1121B.2 .1 9.1% RS at bus pad , 10.4% RS at the road. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 37 Hawthorne Blvd./ Vallon Dr. (SB) 02.12B - Bus Stop Pad Slope Perpendicular to Roadway Bus stop pad slope perpendicular to the roadway exceeds 2%. 10.2.1 810.2.4 1121B.2 .1 4.4% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 38 Hawthorne Blvd./ Vallon Dr. (SB) 02.11A - Bus Stop Pad Size Bus stop pad does not measure 8’ long (measured from the curb or vehicle roadway edge) by 5’ wide (measured parallel to the vehicle roadway). 10.2.1 810.2.2 1121B.1 Bus pad 5' long by 5' wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 39 Hawthorne Blvd./ Dupre Dr. (SB) 02.12A - Bus Stop Pad Slope Parallel to Roadway Bus stop pad is not at the same slope as the roadway in the direction parallel to the roadway. 10.2.1 810.2.4 1121B.2 .1 8% RS at bus pad , 10.8% RS at the road. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 40 Hawthorne Blvd./ Dupre Dr. (SB) 02.17 - Other - Passenger Loading Zones See Additional Comments ---Bench (16" high seat, 14" deep seat, 14 1/2" high back support). PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 1 - Access into Facilities (28 CFR 36.304(c)(1)) 41 Hawthorne Blvd./ Dupre Dr. (NB) 02.13A - Bus Stop Shelter - Clear Floor Area Clear floor area of 30” by 48” is not completely within the shelter. 10.2.1(2 ) 810.3 1121B.2 .1 No WC space provided within the shelter. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 42 Hawthorne Blvd./ Dupre Dr. (NB) Page 6 of 9 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # Area 5 Bus StopsReporting: 60 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 02 - Passenger Loading Zone Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 02.12A - Bus Stop Pad Slope Parallel to Roadway Bus stop pad is not at the same slope as the roadway in the direction parallel to the roadway. 10.2.1 810.2.4 1121B.2 .1 7.7% to 9.4 RS at bus pad, 6.5% to 7.4% RS at the road. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 43 Hawthorne Blvd./ Dupre Dr. (NB) 02.12B - Bus Stop Pad Slope Perpendicular to Roadway Bus stop pad slope perpendicular to the roadway exceeds 2%. 10.2.1 810.2.4 1121B.2 .1 3.4% to 3.6% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 44 Hawthorne Blvd./ Dupre Dr. (NB) 02.17 - Other - Passenger Loading Zones See Additional Comments ---Bench (16" high seat, 13 1/2" deep seat, 14 1/2" high back support). PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 1 - Access into Facilities (28 CFR 36.304(c)(1)) 45 Hawthorne Blvd./ Los Verdes Dr. (NB) 02.13A - Bus Stop Shelter - Clear Floor Area Clear floor area of 30” by 48” is not completely within the shelter. 10.2.1(2 ) 810.3 1121B.2 .1 No WC space provided within the shelter. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 46 Hawthorne Blvd./ Los Verdes Dr. (NB) 02.11B - Bus Stop Pad and Accessible Route Bus stop pad is not connected to an accessible route. 10.2.1 810.2.3 1121B.1 No accessible route to bus stop. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 47 Hawthorne Blvd./ Los Verdes Dr. (NB) 02.11A - Bus Stop Pad Size Bus stop pad does not measure 8’ long (measured from the curb or vehicle roadway edge) by 5’ wide (measured parallel to the vehicle roadway). 10.2.1 810.2.2 1121B.1 Bus pad 6' long by 5' wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 48 Hawthorne Blvd./ Los Verdes Dr. (NB) 02.12A - Bus Stop Pad Slope Parallel to Roadway Bus stop pad is not at the same slope as the roadway in the direction parallel to the roadway. 10.2.1 810.2.4 1121B.2 .1 4.7% to 5.7% RS at bus pad, 5.1% to 5.7% RS at the road. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 49 Hawthorne Blvd./ Los Verdes Dr. (NB) Page 7 of 9 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # Area 5 Bus StopsReporting: 60 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 02 - Passenger Loading Zone Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 02.11A - Bus Stop Pad Size Bus stop pad does not measure 8’ long (measured from the curb or vehicle roadway edge) by 5’ wide (measured parallel to the vehicle roadway). 10.2.1 810.2.2 1121B.1 Bus pad 3'-11" long by 5' wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 50 Hawthorne Blvd./ Los Verdes Dr. (SB) 02.12B - Bus Stop Pad Slope Perpendicular to Roadway Bus stop pad slope perpendicular to the roadway exceeds 2%. 10.2.1 810.2.4 1121B.2 .1 4.5% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 51 Hawthorne Blvd./ Los Verdes Dr. (SB) 02.11B - Bus Stop Pad and Accessible Route Bus stop pad is not connected to an accessible route. 10.2.1 810.2.3 1121B.1 No accessible route to bus stop. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 52 Hawthorne Blvd./ Los Verdes Dr. (SB) 02.12A - Bus Stop Pad Slope Parallel to Roadway Bus stop pad is not at the same slope as the roadway in the direction parallel to the roadway. 10.2.1 810.2.4 1121B.2 .1 6.1% RS at bus pad, 6.2% RS at the road. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 53 Hawthorne Blvd./ Crest Rd. (SB) 02.12B - Bus Stop Pad Slope Perpendicular to Roadway Bus stop pad slope perpendicular to the roadway exceeds 2%. 10.2.1 810.2.4 1121B.2 .1 2.4% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 54 Hawthorne Blvd./ Crest Rd. (SB) 02.11A - Bus Stop Pad Size Bus stop pad does not measure 8’ long (measured from the curb or vehicle roadway edge) by 5’ wide (measured parallel to the vehicle roadway). 10.2.1 810.2.2 1121B.1 Bus pad 4' long by 5' wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 55 Hawthorne Blvd./ Crest Rd. (SB) 02.11A - Bus Stop Pad Size Bus stop pad does not measure 8’ long (measured from the curb or vehicle roadway edge) by 5’ wide (measured parallel to the vehicle roadway). 10.2.1 810.2.2 1121B.1 Bus pad 5'-7" long by 5' wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 56 Crest Rd./ Hawthorne Blvd. (EB) Page 8 of 9 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # Area 5 Bus StopsReporting: 60 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 02 - Passenger Loading Zone Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 02.12B - Bus Stop Pad Slope Perpendicular to Roadway Bus stop pad slope perpendicular to the roadway exceeds 2%. 10.2.1 810.2.4 1121B.2 .1 5.0% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 57 Crest Rd./ Hawthorne Blvd. (EB) 02.17 - Other - Passenger Loading Zones See Additional Comments ---Bench (16" high seat, 14" deep seat, 15" high back support). PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 1 - Access into Facilities (28 CFR 36.304(c)(1)) 58 Hawthorne Blvd./ Crest Rd. (NB) 02.13A - Bus Stop Shelter - Clear Floor Area Clear floor area of 30” by 48” is not completely within the shelter. 10.2.1(2 ) 810.3 1121B.2 .1 No WC space provided within the shelter. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 59 Hawthorne Blvd./ Crest Rd. (NB) 02.17 - Other - Passenger Loading Zones See Additional Comments ---2.2% to 2.3% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 60 Hawthorne Blvd./ Crest Rd. (NB) 60Number of Key Notes for Group 02 - Passenger Loading Zone: 60Number of Key Notes for Facility Area 5 Bus Stops: 60Total Number of Key Notes for All Groups: Page 9 of 9 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA