Loading...
Area 4 Bus Stops_ComplianceReport_20130509-115546Facility ID # Area 4 Bus StopsReporting: 18 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 02 - Passenger Loading Zone Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 02.12B - Bus Stop Pad Slope Perpendicular to Roadway Bus stop pad slope perpendicular to the roadway exceeds 2%. 10.2.1 810.2.4 1121B.2 .1 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 1 Crest Rd./ Mela Ln. (EB) 02.17 - Other - Passenger Loading Zones See Additional Comments ---Bench (16" high seat, 13" deep seat, 15" high back support). PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 1 - Access into Facilities (28 CFR 36.304(c)(1)) 2 Crest Rd./ Mela Ln. (WB) 02.11A - Bus Stop Pad Size Bus stop pad does not measure 8’ long (measured from the curb or vehicle roadway edge) by 5’ wide (measured parallel to the vehicle roadway). 10.2.1 810.2.2 1121B.1 Bus pad 7' long x 5' wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 3 Crest Rd./ Mela Ln. (WB) 02.17 - Other - Passenger Loading Zones See Additional Comments ---2.3% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 4 Crest Rd./ Mela Ln. (WB) 02.12A - Bus Stop Pad Slope Parallel to Roadway Bus stop pad is not at the same slope as the roadway in the direction parallel to the roadway. 10.2.1 810.2.4 1121B.2 .1 3.2% RS at bus pad, 2.7% RS at road. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 5 Crest Rd./ Mela Ln. (WB) 02.11A - Bus Stop Pad Size Bus stop pad does not measure 8’ long (measured from the curb or vehicle roadway edge) by 5’ wide (measured parallel to the vehicle roadway). 10.2.1 810.2.2 1121B.1 Bus pad 7'-2" long x 5' wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 6 Crenshaw Blvd./ Crestridge Rd. (NB) 02.12A - Bus Stop Pad Slope Parallel to Roadway Bus stop pad is not at the same slope as the roadway in the direction parallel to the roadway. 10.2.1 810.2.4 1121B.2 .1 8.8% RS at bus pad , 7.2% RS at the road. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 7 Crenshaw Blvd./ Crestridge Rd. (NB) Page 1 of 3 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # Area 4 Bus StopsReporting: 18 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 02 - Passenger Loading Zone Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 02.17 - Other - Passenger Loading Zones See Additional Comments ---Bench (16" high seat, 14" deep seat, 14" high back support). PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 1 - Access into Facilities (28 CFR 36.304(c)(1)) 8 Crenshaw Blvd./ Crestridge Rd. (SB) 02.11A - Bus Stop Pad Size Bus stop pad does not measure 8’ long (measured from the curb or vehicle roadway edge) by 5’ wide (measured parallel to the vehicle roadway). 10.2.1 810.2.2 1121B.1 Bus pad 4'-11" long x 5' wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 9 Crenshaw Blvd./ Crestridge Rd. (SB) 02.12A - Bus Stop Pad Slope Parallel to Roadway Bus stop pad is not at the same slope as the roadway in the direction parallel to the roadway. 10.2.1 810.2.4 1121B.2 .1 6.2% RS at bus pad, 4.1% RS at the road. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 10 Crenshaw Blvd./ Crestridge Rd. (SB) 02.12B - Bus Stop Pad Slope Perpendicular to Roadway Bus stop pad slope perpendicular to the roadway exceeds 2%. 10.2.1 810.2.4 1121B.2 .1 2.5% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 11 Crest Rd./ Whitley Collins Dr. (WB) 02.12A - Bus Stop Pad Slope Parallel to Roadway Bus stop pad is not at the same slope as the roadway in the direction parallel to the roadway. 10.2.1 810.2.4 1121B.2 .1 2.0% RS at bus pad , 1.7% RS at the road. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 12 Crest Rd./ Whitley Collins Dr. (EB) 02.12B - Bus Stop Pad Slope Perpendicular to Roadway Bus stop pad slope perpendicular to the roadway exceeds 2%. 10.2.1 810.2.4 1121B.2 .1 3.0% to 3.3% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 13 Crest Rd./ Whitley Collins Dr. (EB) 02.12B - Bus Stop Pad Slope Perpendicular to Roadway Bus stop pad slope perpendicular to the roadway exceeds 2%. 10.2.1 810.2.4 1121B.2 .1 6.9% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 14 Crest Rd./ Highridge Rd. (WB) Page 2 of 3 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # Area 4 Bus StopsReporting: 18 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 02 - Passenger Loading Zone Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 02.11A - Bus Stop Pad Size Bus stop pad does not measure 8’ long (measured from the curb or vehicle roadway edge) by 5’ wide (measured parallel to the vehicle roadway). 10.2.1 810.2.2 1121B.1 Bus pad 4'-1" long by 5' wide.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 15 Highridge R./ Scotwood Dr. (NB) 02.12A - Bus Stop Pad Slope Parallel to Roadway Bus stop pad is not at the same slope as the roadway in the direction parallel to the roadway. 10.2.1 810.2.4 1121B.2 .1 6.3% RS at bus pad, 5.5% RS at the road. PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 16 Highridge R./ Scotwood Dr. (NB) 02.11A - Bus Stop Pad Size Bus stop pad does not measure 8’ long (measured from the curb or vehicle roadway edge) by 5’ wide (measured parallel to the vehicle roadway). 10.2.1 810.2.2 1121B.1 Bus pad 4' long by 5' wide .PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 17 Highridge R./ Whitley Collins Dr. (NB) 02.12B - Bus Stop Pad Slope Perpendicular to Roadway Bus stop pad slope perpendicular to the roadway exceeds 2%. 10.2.1 810.2.4 1121B.2 .1 3.3% CS.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 18 Highridge R./ Whitley Collins Dr. (NB) 18Number of Key Notes for Group 02 - Passenger Loading Zone: 18Number of Key Notes for Facility Area 4 Bus Stops: 18Total Number of Key Notes for All Groups: Page 3 of 3 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA