Loading...
Abalone Cove Shoreline Park_ComplianceReport_20130509-112834Facility ID # 01 - Abalone Cove Shoreline ParkReporting: 200 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 17 - Bathing and Shower Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 17.01 - Accessible Bathing or Showering Facilities Where facilities for bathing or showering are provided, less than 1% of these facilities are accessible. 4.23.1; 4.23.8 213.3.6 1115B.2 -Twist type controls & no P.O.T.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 117 Shower at Beach 17.01 - Accessible Bathing or Showering Facilities Where facilities for bathing or showering are provided, less than 1% of these facilities are accessible. 4.23.1; 4.23.8 213.3.6 1115B.2 -EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 178 Lifeguard Sanitary Room 2Number of Key Notes for Group 17 - Bathing and Shower Facilities: Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 30 Concession Entry 11.15B_04AG - Vision Lights Door, gate, or adjacent sidelight, containing one or more vision lights, does not include at least one vision light mounted with the bottom edge of the glazed panel at 43" max.. AFF. (Exception: Vision lights with the lowest part more than 66" AFF.) -404.2.1 1 --PV - Public/Visitor Use E - Non- Mandated Access Improveme nt 1 - Access into Facilities (28 CFR 36.304(c)(1)) 31 Concession Entry 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Deadbolt & sliding latch.EW - Employee Work Area C - Partial Barrier to Access 6 - Employee- Only Work Areas (1994 ADAS 4.1.1(3)) 32 Concession - Office Page 1 of 39 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 01 - Abalone Cove Shoreline ParkReporting: 200 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.17B - Room/Space Identification Signs (Visual/Tactile Signs) Sign designating the permanent room or space does not comply with ADAAG and CBC requirements for tactile signs. 4.1.2(7) ; 4.30.1, 4, 5, 6 216.2; 703.1; 703.2; 703.5 1117B.5 .2, 3, 5, 6, 7 -EW - Employee Work Area D - Minor Code Deviation 6 - Employee- Only Work Areas (1994 ADAS 4.1.1(3)) 33 Concession - Office 11.23A - Mounting Location (Visual/Tactile Signs) Sign is not mounted on the wall adjacent to the latch side of the door. OR At double leaf doors, the sign is not placed on the nearest adjacent wall. 4.30.6 703.4.2 1117B.5 .7 -EW - Employee Work Area C - Partial Barrier to Access 6 - Employee- Only Work Areas (1994 ADAS 4.1.1(3)) 34 Concession - Office 11.15A - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -Door stop.EC - Employee Common Use C - Partial Barrier to Access 6 - Employee- Only Work Areas (1994 ADAS 4.1.1(3)) 41 Storage 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -EC - Employee Common Use E - Non- Mandated Access Improveme nt 6 - Employee- Only Work Areas (1994 ADAS 4.1.1(3)) 42 Storage Page 2 of 39 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 01 - Abalone Cove Shoreline ParkReporting: 200 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab. 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2 Fig. 11B-26 -Non-fixed furniture.EC - Employee Common Use C - Partial Barrier to Access 6 - Employee- Only Work Areas (1994 ADAS 4.1.1(3)) 44 Storage 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -EW - Employee Work Area E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 54 Concession Bldg. 11.04 - Gates Gate does not comply with all applicable ADAAG and CBC accessibility requirements for doors. (ADAAG and CBC accessibility requirements for doors apply to gates, including ticket gates.) 4.13.3 404.2; 404.3 1133B.1 .1.1.4 -CP - Client/Patient Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 118 West Gate at Nursery School 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Rope handle.GS - General Student Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 119 Stage at Play Yard 11.10B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -5" high & step condition.GS - General Student Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 120 Stage at Play Yard Page 3 of 39 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 01 - Abalone Cove Shoreline ParkReporting: 200 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.04 - Gates Gate does not comply with all applicable ADAAG and CBC accessibility requirements for doors. (ADAAG and CBC accessibility requirements for doors apply to gates, including ticket gates.) 4.13.3 404.2; 404.3 1133B.1 .1.1.4 -CP - Client/Patient Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 122 North Gate at Nursery School 11.04 - Gates Gate does not comply with all applicable ADAAG and CBC accessibility requirements for doors. (ADAAG and CBC accessibility requirements for doors apply to gates, including ticket gates.) 4.13.3 404.2; 404.3 1133B.1 .1.1.4 -Sliding gate.CP - Client/Patient Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 129 North Gate at Nursery School 11.04 - Gates Gate does not comply with all applicable ADAAG and CBC accessibility requirements for doors. (ADAAG and CBC accessibility requirements for doors apply to gates, including ticket gates.) 4.13.3 404.2; 404.3 1133B.1 .1.1.4 -> than 1/2" transition from playground to sand. CP - Client/Patient Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 131 South of Nursery School 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -GS - General Student Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 142 All Purpose Room 11.05A - Clear Opening - Single- Leaf Door When the door is open 90 degrees, clear opening width is not at least 32” measured between the face of the door and the doorstop on the latch side. 4.13.5 404.2.3 1133B.1 .1.1.1; 1133B.2 .2 -30" clear.GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 155 Hall to All Purpose Room 11.05A - Clear Opening - Single- Leaf Door When the door is open 90 degrees, clear opening width is not at least 32” measured between the face of the door and the doorstop on the latch side. 4.13.5 404.2.3 1133B.1 .1.1.1; 1133B.2 .2 -29 1/2" clear.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 156 Kitchen Page 4 of 39 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 01 - Abalone Cove Shoreline ParkReporting: 200 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 11 - Doors and Gates Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 11.11 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Lock.EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 157 Kitchen 11.12 - Hardware Mounting Height Mounting height of all operating hardware is not 30” min.. or 44” max.., as measured to the highest operable part. (1994 ADA Standards permit a max.. height of 48"; CBC Standards permit a range of 30” min.. to 44” max..) 4.13.9 -1133B.2 .5.2 -57" high.EC - Employee Common Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 158 Kitchen 11.17A - Recommendation: Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.1.2(7) 216.2; 703.1; 703.2; 703.5 1117B.5 .1 item 1 -EC - Employee Common Use E - Non- Mandated Access Improveme nt 2 - Program Areas (28 CFR 36.304(c)(2)) 159 Kitchen 21Number of Key Notes for Group 11 - Doors and Gates: Group 18 - Dressing, Fitting and Locker Rooms Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 18.01 - Dressing, Fitting, and Locker Rooms Dressing, fitting, or locker room does not comply with all applicable CBC and ADAAG accessibility requirements. 4.1.3 (21); 4.35.1 222.1 1117B.8 -EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 179 Lifeguard Sanitary Room 18.05A - Fixed Bench Requirement Fixed bench is not provided.4.35.4 803.4 1117B.8 -EC - Employee Common Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 180 Lifeguard Sanitary Room 2Number of Key Notes for Group 18 - Dressing, Fitting and Locker Rooms: Page 5 of 39 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 01 - Abalone Cove Shoreline ParkReporting: 200 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 05 - Drinking Fountains Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 05.01A - "Hi" Drinking Fountain Requirement Where there is only one drinking fountain area on a floor (e.g.., an area with a drinking fountain or separate drinking fountains), it is accessible to wheelchair users and not to persons who have difficulty bending or stooping (i.e., the required accessibility for persons who have difficulty bending or stooping on each floor has not been provided). 4.1.3(10 )(a); 4.15.1 211.1; 211.2 1115B.4 .6 item 1 -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 55 Concession Bldg. 05.05A - Knee Space Height Drinking fountain provides less than 27” high accessible knee clearance between the bottom of the apron and the floor. 4.15.5(1 ); Figs. 27(a) and (b) 306.3; Fig. 306.3 1115B.4 .6 item 2 -22" high.PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 56 Concession Bldg. 05.05C - Knee Space Depth Drinking fountain provides less than 8" deep accessible knee clearance between the bottom of the apron and the floor, the depth measured from the front edge of the drinking fountain back towards the wall or post. 4.15.5(1 ); Figs. 27(a) and (b) 306.3; Figs. 306.3 1115B.4 .6 item 2 -4"PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 57 Concession Bldg. 05.09A - Spout Height for Wheelchair Users The spout outlet is higher than 36” from the floor. 4.15.2 602.4; 602.6; Advisory 602.6 1115B.4 .6 item 4 -38" high.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 58 Concession Bldg. 4Number of Key Notes for Group 05 - Drinking Fountains: Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.02 - Entrance Sign Accessible entrance is not identified by an ISA.28 CFR 35.163( b)1 216.6 1117B.5 .8.1.2 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 25 Concession Entry Page 6 of 39 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 01 - Abalone Cove Shoreline ParkReporting: 200 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.07A - Landing - Level and Clear Floor is not level (slope is greater than 2% in some or all directions). OR Floor is not clear within the required maneuvering space. 4.13.6; Fig. 25 305; 404.2.4. 4 1133B.2 .4 -PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 26 Concession Entry 10.08 - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 27 Concession Entry 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 28 Concession Entry 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 29 Concession Entry 10.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab.404 .2.4.1; Fig.404. 2.4.1 1133B.2 .4.2; Fig. 11B-26 -40" CLR. @ pull side landing.EC - Employee Common Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 47 Storage Page 7 of 39 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 01 - Abalone Cove Shoreline ParkReporting: 200 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.08 - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -Door stop.EC - Employee Common Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 48 Storage 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -EC - Employee Common Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 49 Storage 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -EC - Employee Common Use D - Minor Code Deviation 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 50 Storage 10.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab.404 .2.4.1; Fig.404. 2.4.1 1133B.2 .4.2; Fig. 11B-26 -4" clear at pull side. Drinking fountain encroachment. EW - Employee Work Area C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 53 Concession Bldg. Page 8 of 39 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 01 - Abalone Cove Shoreline ParkReporting: 200 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -> than 30 LBF. sliding gate.CP - Client/Patient Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 128 North Gate at Nursery School 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -CP - Client/Patient Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 132 South of Nursery School 10.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -25 LBF.CP - Client/Patient Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 133 South of Nursery School 10.02 - Entrance Sign Accessible entrance is not identified by an ISA.28 CFR 35.163( b)1 216.6 1117B.5 .8.1.2 -GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 134 All Purpose Room 10.05 - Clear Door Opening When the door is open 90 degrees, clear opening width is not at least 32” measured between the face of the door and the doorstop on the latch side. 4.13.5 404.2.3; Fig. 404.2.3 1133B.1 .1.1.1; 1133B.2 .2 -27" clear.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 135 All Purpose Room Page 9 of 39 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 01 - Abalone Cove Shoreline ParkReporting: 200 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.06A - Door Maneuvering Space Door that is not automatic or power-assisted does not have compliant maneuvering space relative to the direction of approach as shown in CBC Fig. 11B-26. (Approach // Side // Width // Depth) (Front // Pull // D + 24” * // 60”) (Front // Push // D + 0” ** // 48”) (Latch // Pull // D + 24” // 60”) (Latch // Push // D + 24” // 44” ***) (Hinge // Pull // D + 36” // 60”) (Hinge // Push // 54” **** // 44” *****) (* D + 18” at interior doors.) (** D + 12” if door has both a latch and a closer.) (*** 48” if door has closer.) (**** Measured from latch toward hinge.) (***** 48” if door has both a latch and a closer.) 4.13.6; Fig. 25 404.2.4. 1; Tab.404 .2.4.1; Fig.404. 2.4.1 1133B.2 .4.2; Fig. 11B-26 -4" at pull side.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 136 All Purpose Room 10.07A - Landing - Level and Clear Floor is not level (slope is greater than 2% in some or all directions). OR Floor is not clear within the required maneuvering space. 4.13.6; Fig. 25 305; 404.2.4. 4 1133B.2 .4 -4.5%GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 137 All Purpose Room 10.08 - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -Door stop.GS - General Student Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 138 All Purpose Room 10.09B - Threshold - Height The threshold at doorway exceeds 1/2” in height. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -1 3/4" high.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 139 All Purpose Room Page 10 of 39 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 01 - Abalone Cove Shoreline ParkReporting: 200 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -GS - General Student Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 140 All Purpose Room 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -GS - General Student Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 141 All Purpose Room 10.09A - > 1/4" Changes in Level - Threshold Where threshold is 1/4" min.. to 1/2" max.. in height, change in level is not beveled at 1:2 or less. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -> 1/4" abrupt.EW - Employee Work Area C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 162 North Exit Door 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Lock.EW - Employee Work Area B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 163 North Exit Door 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -EW - Employee Work Area C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 164 North Exit Door 10.08 - Kick Plate Bottom 10” of door does not have a smooth, uninterrupted surface on the push side to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition. (This requirement does not apply to automatic and sliding doors.) -404.2.1 0 1133B.2 .6 -EW - Employee Work Area A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 165 Patio Door Page 11 of 39 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 01 - Abalone Cove Shoreline ParkReporting: 200 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 10 - Entrances and Exits Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 10.09A - > 1/4" Changes in Level - Threshold Where threshold is 1/4" min.. to 1/2" max.. in height, change in level is not beveled at 1:2 or less. 4.13.8 303.3; Advisory 303.3; Fig. 303.3 1133B.2 .4.1 -EW - Employee Work Area C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 166 Patio Door 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -Lock.EW - Employee Work Area B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 167 Patio Door 10.07A - Landing - Level and Clear Floor is not level (slope is greater than 2% in some or all directions). OR Floor is not clear within the required maneuvering space. 4.13.6; Fig. 25 305; 404.2.4. 4 1133B.2 .4 -9.9%EW - Employee Work Area C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 168 Patio Door 10.05 - Clear Door Opening When the door is open 90 degrees, clear opening width is not at least 32” measured between the face of the door and the doorstop on the latch side. 4.13.5 404.2.3; Fig. 404.2.3 1133B.1 .1.1.1; 1133B.2 .2 -30" clear.EC - Employee Common Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 181 Lifeguard Sanitary Room 10.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand and without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -EC - Employee Common Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 182 Lifeguard Sanitary Room 10.13A - Required Exit Door Sign At grade level exterior exit door, there is no tactile and CA Braille exit sign with the word “EXIT” mounted on the wall adjacent to the latch side of the door. 4.1.3(16 ); 4.30.1 216.4; 703.2; 703.3; 703.4 1011.3 item 1 -EC - Employee Common Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 183 Lifeguard Sanitary Room 31Number of Key Notes for Group 10 - Entrances and Exits: Page 12 of 39 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 01 - Abalone Cove Shoreline ParkReporting: 200 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.03 - Facilities Connected Accessible routes of travel do not connect all accessible buildings, facilities, elements and spaces on the same site with one another. 4.1.2(2) (a) 206.2.2; Advisory 206.2.2 1114B.1 .2; 1127B.1 -P.O.T no connection to park.EC - Employee Common Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 51 N. Path leading to storage Rm. 03B.04 - Width Accessible route of travel is less than 48” wide (note: 48" wide requirement does not apply to doorways or gates). 4.3.3 403.5.1 1133B.7 .1 -40" wide walkway.EC - Employee Common Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 52 N. Path leading to storage Rm. 03B.04 - Width Accessible route of travel is less than 48” wide (note: 48" wide requirement does not apply to doorways or gates). 4.3.3 403.5.1 1133B.7 .1 -36" walkway.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 59 Near Concession Bldg. 03B.22 - Other - On-Site Accessible Path of Travel See Additional Comments ----Vending machine on P.O.T.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 60 Near Concession Bldg. 03B.03 - Facilities Connected Accessible routes of travel do not connect all accessible buildings, facilities, elements and spaces on the same site with one another. 4.1.2(2) (a) 206.2.2; Advisory 206.2.2 1114B.1 .2; 1127B.1 -No P.O.T. from parking to play ground to nursery school. PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 123 Playground 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -9.5%GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 124 East of Shade Structure Page 13 of 39 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 01 - Abalone Cove Shoreline ParkReporting: 200 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 03B - On-Site Path of Travel Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 03B.15 - Surface Accessible route surfaces are not stable, firm and slip-resistant. 4.5.1 302.1; Advisory 302.1 1124B.1 -Loose gravel.GS - General Student Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 125 East of Shade Structure 03B.13 - > 1/2" Changes in Level Curb ramps, ramps, or elevators are not used for changes in level greater than 1/2 inch. (Lifts may only be used in certain limited situations.) 4.5.2 303.4 1124B.2 -> 1/2" at utility cover.GS - General Student Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 126 East of Shade Structure 03B.09 - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.3%CP - Client/Patient Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 130 West of Nursery School 9Number of Key Notes for Group 03B - On-Site Path of Travel: Group 01 - Parking Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 01.02 - Number - Accessible Parking Spaces Where parking spaces are provided for self- parking by employees or visitors or both, the required number of accessible parking spaces is not provided. (Note: All or some of the accessible parking spaces may be in a different location if equivalent or greater accessibility is ensured.) (Spaces required: (1 to 25 // 1) (26 to 50 // 2) (51 to 75 // 3) (76 to 100 // 4) (101 to 150 // 5) (151 to 200 // 6) (201 to 300 // 7) (301 to 400 // 8) (401 to 500 // 9) (501 to 1,000 // *) (1,000 and over // **) (*Two percent of total.) (**Twenty plus one for each 100, or fraction over 1,001.) 4.1.2(5) 208.3.1( 2) 1129B.1 ; 1129B.2 ; Table 11B-6 Non marked stalls, two ISA Signs at central entrance. PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 1 Parking Lot Page 14 of 39 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 01 - Abalone Cove Shoreline ParkReporting: 200 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 01 - Parking Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 01.04 - Van Accessible Spaces Lot does not provides the required number of designated "van accessible" parking spaces (one in every eight accessible parking spaces; one in every six per 2004 ADAAG). 4.1.2(5) (b); 4.6.4 208.2.4 1129B.3 item 2, 1129B.4 PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 2 Parking Lot 01.09 - Stall Dimensions Accessible parking spaces, including van spaces, are not at least 9’ wide and 18’ long with a demarcated access aisle. (Two spaces may share a common aisle; parking space width is measured from the center line of the stripe on one side to the center line of the stripe on the other.) 4.6.3 502.2 1129B.3 items 1 & 2 Not demarcated, none provided. PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 3 Parking Lot 01.11 - Car Access Aisle - Dimensions Car access aisle is not at least 5’ wide and 18’ long. (Aisle width is measured from the center line of the stripe on one side to the center line of the stripe on the other.) 4.1.2(5) (a) 502.3.1 1129B.3 item 1 Not demarcated, none provided. PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 4 Parking Lot 01.14 - Surface Access aisle is not stable, firm, and slip resistant. 4.5.1 302 1124B.1 Gravel.PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 5 Parking Lot 01.15A - Access Aisle and Accessible Route Access aisle do not connects directly to an accessible route of travel. 4.3 502.3 1129B.1 None provided.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 6 Parking Lot 01.15B - Parking Space Sign Accessible parking space has no reflectorized sign visible from the stall, showing an ISA in white on a blue background. 4.6.4 502.6 1129B.4 PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 7 Parking Lot Page 15 of 39 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 01 - Abalone Cove Shoreline ParkReporting: 200 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 01 - Parking Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 01.15C - Minimum Fine Sign Accessible parking space has no sign stating "Minimum Fine $250" below the ISA. --1129B.4 PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 8 Parking Lot 01.18 - Pavement Sign A 36” square ISA is not painted on the pavement at the rear of the stall. -502.6 1129B.4 PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 9 Parking Lot 01.19B - Tow- away Sign A California tow-away sign is not posted in a conspicuous place at each entrance to off–street parking lot, or immediately adjacent to and visible from each accessible stall. --1129B.4 PV - Public/Visitor Use B - Severe or Complete Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 10 Parking Lot 01.23 - Other - Parking See Additional Comments ---14 1/2" high Parking Sign.PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 11 Parking Lot 01.02 - Number - Accessible Parking Spaces Where parking spaces are provided for self- parking by employees or visitors or both, the required number of accessible parking spaces is not provided. (Note: All or some of the accessible parking spaces may be in a different location if equivalent or greater accessibility is ensured.) (Spaces required: (1 to 25 // 1) (26 to 50 // 2) (51 to 75 // 3) (76 to 100 // 4) (101 to 150 // 5) (151 to 200 // 6) (201 to 300 // 7) (301 to 400 // 8) (401 to 500 // 9) (501 to 1,000 // *) (1,000 and over // **) (*Two percent of total.) (**Twenty plus one for each 100, or fraction over 1,001.) 4.1.2(5) 208.3.1( 2) 1129B.1 ; 1129B.2 ; Table 11B-6 No demarcated parking (7 cars allowed to park according to nursery school staff). CP - Client/Patient Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 112 Parking Lot at Nursery School Page 16 of 39 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 01 - Abalone Cove Shoreline ParkReporting: 200 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 01 - Parking Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 01.04 - Van Accessible Spaces Lot does not provides the required number of designated "van accessible" parking spaces (one in every eight accessible parking spaces; one in every six per 2004 ADAAG). 4.1.2(5) (b); 4.6.4 208.2.4 1129B.3 item 2, 1129B.4 None provided, no demarcated parking. CP - Client/Patient Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 113 Parking Lot at Nursery School 01.13 - Level Surface The accessible parking spaces and access aisles are not level (slope is greater than 2%). 4.6.3 502.4; advisory 502.4 1129B.3 items 3 & 4 Deteriorating surface, slope @ 4.7% CP - Client/Patient Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 114 Parking Lot at Nursery School 14Number of Key Notes for Group 01 - Parking: Group 30 - Parks Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 30.04 - Accessible Route - Facilities Connected Accessible routes of travel do not connect all accessible buildings, facilities, elements and spaces on the same site with one another. 4.1.2(2) (a) 206.2.2; Advisory 206.2.2 1114B.1 .2; 1127B.1 -No P.O.T. from restrooms to accessible parking & to route entrances.. PV - Public/Visitor Use A - Safety Hazard 1 - Access into Facilities (28 CFR 36.304(c)(1)) 12 Facility to park routes 30.05 - Accessible Route - Width Accessible route of travel is less than 48” wide (note: 48" wide requirement does not apply to doorways or gates). 4.3.3 403.5.1 1133B.7 .1 -26 1/2" clear between posts.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 13 East Route entrance 30.06C - Outdoor Recreation Access Route (ORAR) Surface The surface of the access route is not firm or stable. ---1999 ADAAG- 16.3.1 Loose gravel, and grass.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 14 East Route Page 17 of 39 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 01 - Abalone Cove Shoreline ParkReporting: 200 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 30 - Parks Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 30.06E - Outdoor Recreation Access Route (ORAR) Segment - Cross Slope Cross slope of the access route segment exceeds 3.33%. Exception: Cross slopes of 5% maximum are permitted to ensure proper drainage. ---1999 ADAAG- 16.3.7.1 Varies 3.0% to 6.4%PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 15 East Route 30.06B - Outdoor Recreation Access Route (ORAR) Resting Space Resting space does not comply with 1999 ADAAG Section 16.3.8 (Resting intervals shall be 60" min. in length, shall have a width at least as wide as the access route and have a slope of 3.33% or less in any direction. The installation of resting spaces is required as follows: Percent slope, maximum length, Rest interval: 0% to 5.0%, No restriction, No restriction; 5.1% to 8.33%, 50', Every 50'; 8.34% to 10%, 30', Every 30'.) ---1999 ADAAG- 16.3.8 Grass on P.O.T.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 16 Perimeter Route 30.06C - Outdoor Recreation Access Route (ORAR) Surface The surface of the access route is not firm or stable. ---1999 ADAAG- 16.3.1 Loose dirt, erosion, and grass on trail. PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 17 Perimeter Route 30.06E - Outdoor Recreation Access Route (ORAR) Segment - Cross Slope Cross slope of the access route segment exceeds 3.33%. Exception: Cross slopes of 5% maximum are permitted to ensure proper drainage. ---1999 ADAAG- 16.3.7.1 Varies 4.1% to 31%PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 18 Perimeter Route 30.28 - Picnic Site - Surface Slope The accessible picnic site is located on a surface area with slope greater than 2% in some or all directions.(1999 ADAAG: 3% slope is allowed when necessary for drainage). 4.3.7 403.3 -1999 ADAAG- 16.5.7 PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 19 Near South Route Page 18 of 39 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 01 - Abalone Cove Shoreline ParkReporting: 200 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 30 - Parks Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 30.34C - Picnic Table - Knee Space Depth Picnic table does not provide at least 19" depth for accessible knee clearance. 4.32.3 305; 306 1122B.3 1999 ADAAG- 16.5.4 14 1/2" deep.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 20 Near South Route 30.06A - Outdoor Recreation Access Route (ORAR) Segment - Running Slope Running slope of access route segment in the direction of travel does not comply with the following: a. 5% or less for any distance. b. From 5.1% to 8.33% for 50' maximum. c. From 8.34% to 10% for 30' maximum. ---1999 ADAAG- 16.3.7.2 .1; 16.3.7.2 .2; 16.3.7.2 .3 11.1%PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 21 Central Route 30.06C - Outdoor Recreation Access Route (ORAR) Surface The surface of the access route is not firm or stable. ---1999 ADAAG- 16.3.1 Loose dirt, erosion, & grass on trail. PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 22 Central Route 30.06E - Outdoor Recreation Access Route (ORAR) Segment - Cross Slope Cross slope of the access route segment exceeds 3.33%. Exception: Cross slopes of 5% maximum are permitted to ensure proper drainage. ---1999 ADAAG- 16.3.7.1 4.8%PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 23 Central Route 30.05 - Accessible Route - Width Accessible route of travel is less than 48” wide (note: 48" wide requirement does not apply to doorways or gates). 4.3.3 403.5.1 1133B.7 .1 -35" clear width.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 24 West Route entrance 30.11E - Trails - Tread Obstacles Tread obstacles such as roots or rocks are higher than 2". Exception: obstacles may be up to 3" high where the running slope and cross slope are 5% or less. ---1999 ADAAG- 16.2.5 2" to 3" rocks.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 184 Chapel View Trail Page 19 of 39 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 01 - Abalone Cove Shoreline ParkReporting: 200 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 30 - Parks Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 30.10A - Trail Segment - Running Slope Running slope of trail segment in the direction of travel does not comply with the following: a. 5% or less for any distance. b. From 5.1% to 8.33% for 200' maximum. c. From 8.34% to 10% for 30' maximum. d. From 10% to 12% for 10' maximum. ---1999 ADAAG- 16.2.7.2 .1; 16.2.7.2 .2; 16.2.7.2 .3; 16.2.7.2 .4 15.1% to 27.2%.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 185 Chapel View Trail 30.10C - Trail Segment - Cross Slope Cross slope of the trail segment exceeds 1:20.---1999 ADAAG- 16.2.7.1 5.8% to 21.1%PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 186 Chapel View Trail 30.11H - Trails - Signs Trail complying with 1999 ADAAG Section 16.2 is not designated with a symbol at the trailhead and at designated access points. OR Signage has been provided but does not indicate the total distance of the accessible segment and the location of the first point of departure from the Section 16.2 requirements. ---1999 ADAAG- 16.2.10 PV - Public/Visitor Use D - Minor Code Deviation 2 - Program Areas (28 CFR 36.304(c)(2)) 187 Chapel View Trail 30.10E - Trail Surface The surface of the trail is not firm or stable.---1999 ADAAG- 16.2.1 Loose rocks.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 188 Chapel View Trail 30.10A - Trail Segment - Running Slope Running slope of trail segment in the direction of travel does not comply with the following: a. 5% or less for any distance. b. From 5.1% to 8.33% for 200' maximum. c. From 8.34% to 10% for 30' maximum. d. From 10% to 12% for 10' maximum. ---1999 ADAAG- 16.2.7.2 .1; 16.2.7.2 .2; 16.2.7.2 .3; 16.2.7.2 .4 14.9% to 23%..PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 189 Abalone Cove Trail Page 20 of 39 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 01 - Abalone Cove Shoreline ParkReporting: 200 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 30 - Parks Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 30.10B - Trail Resting Space Resting space does not comply with 1999 ADAAG Section 16.2.8 (Resting intervals shall be 60" min. in length, shall have a width at least as wide as the trail and have a slope of 5% or less in any direction. The installation of resting spaces is required as follows: Percent slope, maximum length, Rest interval: 0% to 5.0%, No restriction, No restriction; 5.1% to 8.33%, 200', Every 200'; 8.34% to 10%, 30', Every 30'; 10.1% to 12%, 10', Every 10'.) ---1999 ADAAG- 16.2.7.2 ; 16.2.8 PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 190 Abalone Cove Trail 30.10C - Trail Segment - Cross Slope Cross slope of the trail segment exceeds 1:20.---1999 ADAAG- 16.2.7.1 9.6% to 15.8%PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 191 Abalone Cove Trail 30.10E - Trail Surface The surface of the trail is not firm or stable.---1999 ADAAG- 16.2.1 Loose rocks, 2 1/2" high roots, pipes, & erosion. PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 192 Abalone Cove Trail 30.11H - Trails - Signs Trail complying with 1999 ADAAG Section 16.2 is not designated with a symbol at the trailhead and at designated access points. OR Signage has been provided but does not indicate the total distance of the accessible segment and the location of the first point of departure from the Section 16.2 requirements. ---1999 ADAAG- 16.2.10 PV - Public/Visitor Use D - Minor Code Deviation 2 - Program Areas (28 CFR 36.304(c)(2)) 193 Abalone Cove Trail 30.04 - Accessible Route - Facilities Connected Accessible routes of travel do not connect all accessible buildings, facilities, elements and spaces on the same site with one another. 4.1.2(2) (a) 206.2.2; Advisory 206.2.2 1114B.1 .2; 1127B.1 -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 194 Beach School Trail Page 21 of 39 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 01 - Abalone Cove Shoreline ParkReporting: 200 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 30 - Parks Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 30.10A - Trail Segment - Running Slope Running slope of trail segment in the direction of travel does not comply with the following: a. 5% or less for any distance. b. From 5.1% to 8.33% for 200' maximum. c. From 8.34% to 10% for 30' maximum. d. From 10% to 12% for 10' maximum. ---1999 ADAAG- 16.2.7.2 .1; 16.2.7.2 .2; 16.2.7.2 .3; 16.2.7.2 .4 18% to 51%.PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 195 Abalone Cove Trail 30.10C - Trail Segment - Cross Slope Cross slope of the trail segment exceeds 1:20.---1999 ADAAG- 16.2.7.1 6% to 27%PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 196 Abalone Cove Trail 30.10E - Trail Surface The surface of the trail is not firm or stable.---1999 ADAAG- 16.2.1 Loose gravel, cracks.PV - Public/Visitor Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 197 Abalone Cove Trail 30.11H - Trails - Signs Trail complying with 1999 ADAAG Section 16.2 is not designated with a symbol at the trailhead and at designated access points. OR Signage has been provided but does not indicate the total distance of the accessible segment and the location of the first point of departure from the Section 16.2 requirements. ---1999 ADAAG- 16.2.10 PV - Public/Visitor Use D - Minor Code Deviation 2 - Program Areas (28 CFR 36.304(c)(2)) 198 Abalone Cove Trail 30.24 - Picnic Table - Accessible Route Picnic table is not accessible. OR Picnic table is not connected to an outdoor recreation access route. --1127B.1 ; 1132B.2 1999 ADAAG- 16.5.1.1 PV - Public/Visitor Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 199 East of Nursery School 30.29 - Picnic Site Surface Picnic tables and benches are not on a firm and stable surface. ---1999 ADAAG- 16.5.6 Big rock & meter near picnic table. PV - Public/Visitor Use B - Severe or Complete Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 200 East of Nursery School Page 22 of 39 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 01 - Abalone Cove Shoreline ParkReporting: 200 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 30 - Parks Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 30Number of Key Notes for Group 30 - Parks: Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -Coat hook.EW - Employee Work Area C - Partial Barrier to Access 6 - Employee- Only Work Areas (1994 ADAS 4.1.1(3)) 35 Concession - Office 14.50 - Other - Rooms and Spaces See Additional Comments ----7 LBF. sliding window at counter. CP - Client/Patient Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 36 Concession - Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -58" high lock.EW - Employee Work Area C - Partial Barrier to Access 6 - Employee- Only Work Areas (1994 ADAS 4.1.1(3)) 37 Concession - Office 14.35 - Controls - Operation The controls are not accessible. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.27.4 309.4 1117B.6 (4) -EC - Employee Common Use C - Partial Barrier to Access 6 - Employee- Only Work Areas (1994 ADAS 4.1.1(3)) 38 Concession - Office Page 23 of 39 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 01 - Abalone Cove Shoreline ParkReporting: 200 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.28 - Fixed/Built-in Seating, Tables or Counters At fixed or built-in seating, tables, or counters in public or common employee areas, less than 5% of the provided seating spaces are wheelchair accessible and have a 30” by 48” clear space which overlaps an accessible route of travel. (Wheelchair accessible seating spaces are between 28" - 34" high and with knee space measuring at least 27" high, 30" wide, and 19" deep.) (These elements include study carrels and student laboratory stations.) 4.1.3(18 ); 4.32.1; 4.32.4 226.1; Advisory 226.1; 305; 306; 902.2 1122B.1 -35 3/4" high.EC - Employee Common Use C - Partial Barrier to Access 6 - Employee- Only Work Areas (1994 ADAS 4.1.1(3)) 39 Concession - Office 14.29C - Counter - Knee Space Depth Where seating for persons in wheelchairs is provided at table or counter, knee space is less than 19" deep. 4.32.3 306.3.2; Fig. 306.3 1122B.3 ; Fig. 11B-13 -14 1/2"EC - Employee Common Use D - Minor Code Deviation 6 - Employee- Only Work Areas (1994 ADAS 4.1.1(3)) 40 Concession - Office 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -71" high coat hook.EC - Employee Common Use C - Partial Barrier to Access 6 - Employee- Only Work Areas (1994 ADAS 4.1.1(3)) 43 Storage 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -65" high first aid kit.EC - Employee Common Use C - Partial Barrier to Access 6 - Employee- Only Work Areas (1994 ADAS 4.1.1(3)) 45 Storage Page 24 of 39 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 01 - Abalone Cove Shoreline ParkReporting: 200 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.32A - Reach Range - Controls Controls, dispensers, and similar devices are not between 9” and 54” AFF when the clear floor space allows a parallel approach. OR They are not between 15” and 48” AFF when the clear floor space allows only a forward approach. 4.1.3(13 ); 4.27.3; 4.2.5; 4.2.6 ; Fig. 5; Fig. 6 -1117B.6 (3); 1118.5; 1118.6; Fig. 11B-5C; Fig. 11B-5D -60" high PTD.EC - Employee Common Use C - Partial Barrier to Access 6 - Employee- Only Work Areas (1994 ADAS 4.1.1(3)) 46 Storage 14.31 - Head Room Clear head room is at less than 80" within the pedestrian circulation area, including the accessible route of travel. 4.4.2 307.2; Fig. 307.2 1133B.8 .6.2 -7" at 67 1/2" AFF.GS - General Student Use A - Safety Hazard 2 - Program Areas (28 CFR 36.304(c)(2)) 121 Stage at Play Yard 14.36A - Counter Height Where provided in public or common use areas, countertops are not between 28" - 34” high. (Common use areas are those interior and exterior rooms, spaces, or elements that are made available for the use of a restricted group of people (for example, the occupants of an office building, or the guests of such occupants). 4.32.4 902.3 1122B.4 -38" A.F.F. counter.CP - Client/Patient Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 127 Shade Structure 14.21B - 36" Width Standard The accessible route of travel is not at least 36” wide where the occupancy load is < 10. (For a depth of 24" max.., clear opening width may be reduced to 32" min..) (Doorways are compliant when the door, open 90 degrees, affords a clear opening width of at least 32”.) 4.3.3; Fig. 7(a)(b) 403.5.1; Fig. 403.5.1 1133B.3 .1 -29 1/2" wide.GS - General Student Use C - Partial Barrier to Access 2 - Program Areas (28 CFR 36.304(c)(2)) 143 Chair Storage 14.36B - Kitchen Counter/Sink Height Where provided in public or common use areas, countertops and sinks are not mounted at 34” AFF. max..(Common use areas are those interior and exterior rooms, spaces, or elements that are made available for the use of a restricted group of people (for example, the occupants of an office building, or the guests of such occupants). 4.24.2 212.3; 606.3 1115B.4 .7(2); 1122B.4 -35 1/2"EC - Employee Common Use B - Severe or Complete Barrier to Access 6 - Employee- Only Work Areas (1994 ADAS 4.1.1(3)) 160 Kitchen Page 25 of 39 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 01 - Abalone Cove Shoreline ParkReporting: 200 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 14 - Rooms and Spaces Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 14.37 - Kitchen Sink Sink does not provide accessible knee clearance (i.e. at least 27” high, 30” wide, and 19” deep). 4.24.3 305; 306; 606.2 1115B.4 .7(2); 1122B.4 -Pipes encroach into knee space. EC - Employee Common Use C - Partial Barrier to Access 6 - Employee- Only Work Areas (1994 ADAS 4.1.1(3)) 161 Kitchen 14Number of Key Notes for Group 14 - Rooms and Spaces: Group 06 - Telephones Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 06.02A - Clear Floor Space The accessible telephone does not have a 30” x 48” clear floor space that adjoins or overlaps an accessible route of travel and that allows either a forward or parallel approach by wheelchair users. 4.31.2; 4.2.4 305; 704.2.1; Advisory 704.2.1 1117B.2 .2 -No P.O.T. to payphone.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 83 N.E. of Concession 06.02B - ISA Sign The wheelchair accessible telephone is not identified by the ISA. 4.1.3(17 )(b); 4.30.7(1 ) 703.2.1; Fig. 703.2.1 1117B.5 .8.1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 84 N.E. of Concession 06.02A - Clear Floor Space The accessible telephone does not have a 30” x 48” clear floor space that adjoins or overlaps an accessible route of travel and that allows either a forward or parallel approach by wheelchair users. 4.31.2; 4.2.4 305; 704.2.1; Advisory 704.2.1 1117B.2 .2 -Bollards in front.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 115 Pay Phone North of Lifeguard Tower 06.02B - ISA Sign The wheelchair accessible telephone is not identified by the ISA. 4.1.3(17 )(b); 4.30.7(1 ) 703.2.1; Fig. 703.2.1 1117B.5 .8.1 -PV - Public/Visitor Use C - Partial Barrier to Access 4 - Other Areas/Elements (28 CFR 36.304(c)(4)) 116 Pay Phone North of Lifeguard Tower 4Number of Key Notes for Group 06 - Telephones: Page 26 of 39 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 01 - Abalone Cove Shoreline ParkReporting: 200 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.14A - Mounting Height - Geometric Symbol Signage The geometric symbol is not centered on the door leaf. OR The symbol is not mounted at a height of 60” AFF. --1115B.6 -65" high.PV - Public/Visitor Use D - Minor Code Deviation 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 61 Men's Restroom. 16.19A - Mounting Location (Visual/Tactile Signs) Sign is not mounted on the wall adjacent to the latch side of the door. OR At double leaf doors, the sign is not placed on the nearest adjacent wall. 4.30.6 703.4.2; Fig. 703.4.2 1117B.5 .7 -On door.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 62 Men's Restroom. 16.19B - Mounting Height (Visual/Tactile Signs) Sign is not mounted at 60” o.c. AFF to the centerline of the sign. (If the sign contains pictorial symbols (pictograms) or other non- tactile information, mounting height is measured to the centerline of the tactile characters / Braille portion of the sign.) 4.30.6 703.4.1 1117B.5 .7 -45 1/2" high.PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 63 Men's Restroom. 16.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -14 LBF. door rubs on floor.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 64 Men's Restroom. 16.39A - Maneuvering Space in Front of WC - End- Opening Door Where the stall has an end-opening stall door, the clear space in front of the WC is less than 60" wide by 48" deep. 4.17.3; Fig. 30(b) 404.2.4. 1; Table 404.2.4. 1; Fig. 404.2.4. 1 1115B.4 .1(2); Fig. 11B-1A -47" clear.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 65 Men's Restroom. 16.49B - WC Flush Controls - Location Flush controls are not located on the wide side of the WC where the clear floor space is provided. 4.16.5 604.6; Advisory 604.6 1115B.4 .1(5); Fig. 11B-1A -On center.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 66 Men's Restroom. Page 27 of 39 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 01 - Abalone Cove Shoreline ParkReporting: 200 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.49A - WC Flush Controls - Operation Water closet flush controls are not automatic or operable with one hand. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.16.5; 4.27.4 604.6; Advisory 604.6; 309.4 1115B.4 .1(5); Fig. 11B-1A -20 LBF.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 67 Men's Restroom. 16.53 - SC Dispenser Height Mounting height of seat cover dispenser's highest operable part exceeds 40" AFF. 4.22.7; 4.27.3; 4.2.5; 4.2.6 -1115B.8 .3 -51" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 68 Men's Restroom. 16.55A - Side Grab Bar Height Side grab bar is not centered at 33" AFF. (ADA Standards require side grab bars to be centered from 33" to 36" AFF; CBC Standards require side grab bars to be centered at 33" AFF.) 4.17.6; Figs. 29 & 30 604.5; Advisory 604.5; 604.5.2; Fig. 604.5.2; 609.4 1115B.4 .1(3.1); Fig. 11B-1A -33 1/2" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 69 Men's Restroom. 16.55B - Back Grab Bar Height - Non- Tank-Type WC At non-tank-type WC, back grab bar is not centered at 33" AFF. (ADA Standards require back grab bars to be centered from 33" to 36" AFF; CBC Standards require back grab bars to be centered at 33" AFF.) 4.17.6; Figs. 29 & 30 604.5; Advisory 604.5; 609.4 1115B.4 .1(3.2); Fig. 11B-1A -34 3/4" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 70 Men's Restroom. 16.59 - Side Grab Bar At WC providing front transfer, the side grab bar location is not compliant. (CBC Standards require the side grab bar to extend at least 54” min.. beyond the back wall while the other end is 12” max.. from the back wall. CBC also requires the grab bar's front end to be positioned 24” min.. in front of the WC.) 4.17.6; Figs. 29 & 30 Fig. 604.5.1 1115B.4 .1(3.1); Fig. 11B-1A -53" long.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 71 Men's Restroom. Page 28 of 39 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 01 - Abalone Cove Shoreline ParkReporting: 200 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.32A - U- Pulls at Stall Door The stall door does not have U-pulls on both sides. 4.13.9; 4.17.5 309.4; 404.27; 604.8.1. 2 1115B.3 .1(4.4) -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 72 Men's Restroom. 16.35C - Out- Swinging Stall Door - Approach Where the stall door swings out, the aisle approaching the stall is less than 60” deep. 4.17.5; 4.13.6; Fig. 25 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2; Figs. 11B- 26A and 11B-26B -50" deep door landing.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 73 Men's Restroom. 16.83 - Coat Hook - Height Where a coat hook is provided In an accessible stall, height of coat hook exceeds 48” AFF. 4.2.5 213.3.7; 308; 603.4 1117B.8 -65 1/2" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 74 Men's Restroom. 16.84F - Diaper Changing Table - Operating Height Mounting height of diaper changing table's highest operable part exceeds 40" AFF. (Where provided, at least one shall be accessible.) 4.27.3 308; 309 --43" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 75 Men's Restroom. 16.65A - Wall- Hung Urinal - Rim Projection from Wall The wall-hung urinal's elongated rim does not project 14" min.. to 17" max.. from the wall. 4.18.2 605.2; Fig. 605.2(a) 1115B.4 .2(1) -12" deep.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 76 Men's Restroom. 16.71 - Lavatory - Rim Height Height of lavatory rim or counter surface exceeds 34” AFF. 4.19.2; Fig. 31 606.3 1115B.4 .3(2); Fig 11B- 1D -34 3/8" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 77 Men's Restroom. Page 29 of 39 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 01 - Abalone Cove Shoreline ParkReporting: 200 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.75 - Clear Floor Space at Lavatory There is no clear floor space at least 30” x 48” in front of the lavatory (extending a maximum of 19” underneath the lavatory) to allow a forward approach. 4.19.3; 4.2.4 606.2 1115B.4 .3(3); Fig 11B- 1D -PTD encroaches into lavatory clear floor space. PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 78 Men's Restroom. 16.81 - Lavatory Faucet Operation - Min. 10 Second Standard Self-closing valve remains open for less than 10 seconds. 4.19.5 606.4 1115B.4 .3(1) -5 seconds.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 79 Men's Restroom. 16.82A - Mirror Height - Max. 40" AFF Standard Mirror above accessible lavatory or countertop is mounted so the bottom edge of the reflective surface is not 40” max.. AFF. (ADA Standards require at least one mirror to be accessible; CBC Standards prior to August 1, 2009 required all mirrors to be accessible. Effective August 1, 2009, amended CBC Standards require all mirrors above accessible lavatories or countertops to be accessible.) 4.19.6; Fig. 31 213.3.5; 603.3; Advisory 603.3 1115B.8 .1 -41 3/4" to reflective surface.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 80 Men's Restroom. 16.78 - Pipe Insulation at Lavatory Drainpipes and hot water pipes are not insulated to protect against contact. 4.19.4 606.5 1115B.4 .3(4) -PV - Public/Visitor Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 81 Men's Restroom. 16.84A - Paper Towel Dispenser - Operating Height Mounting height of paper towel dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one paper towel dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one paper towel dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -46" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 82 Men's Restroom. Page 30 of 39 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 01 - Abalone Cove Shoreline ParkReporting: 200 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.12 - Other Door Requirements Door does not comply with all applicable ADAAG and CBC accessibility requirements. 4.13 404.1; Advisory 404.1 1133B.2 -3% to 4.5%PV - Public/Visitor Use C - Partial Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 85 Women's Restroom 16.11A - Door Operating Effort The force required to operate door exceeds 5 lbs. (Fire doors may have up to 15 lbs to achieve positive latching). 4.13.11 404.2.9 1133B.2 .5 -8 LBF.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 1 - Access into Facilities (28 CFR 36.304(c)(1)) 86 Women's Restroom 16.13B - Women's RR Geometric Symbol Signage - Circle Doorway leading to a women’s toilet room is not identified by a circle, 1/4" thick and 12” in diameter. OR Circle is provided, however it is accompanied by words in raised characters and Braille. (ADA and CBC Standards require a separate sign with raised characters and Braille mounted on the wall adjacent to the latch side of the door.) --1115B.6 -Bad Braille.PV - Public/Visitor Use D - Minor Code Deviation 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 87 Women's Restroom 16.19A - Mounting Location (Visual/Tactile Signs) Sign is not mounted on the wall adjacent to the latch side of the door. OR At double leaf doors, the sign is not placed on the nearest adjacent wall. 4.30.6 703.4.2; Fig. 703.4.2 1117B.5 .7 -PV - Public/Visitor Use D - Minor Code Deviation 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 88 Women's Restroom 16.19B - Mounting Height (Visual/Tactile Signs) Sign is not mounted at 60” o.c. AFF to the centerline of the sign. (If the sign contains pictorial symbols (pictograms) or other non- tactile information, mounting height is measured to the centerline of the tactile characters / Braille portion of the sign.) 4.30.6 703.4.1 1117B.5 .7 -50" high.PV - Public/Visitor Use D - Minor Code Deviation 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 89 Women's Restroom Page 31 of 39 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 01 - Abalone Cove Shoreline ParkReporting: 200 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.21A - Raised Characters and Braille (Visual/Tactile Signs) The raised characters on this sign are not accompanied by California Grade 2 Braille (i.e., the dots within each cell are domed and spaced 1/10” o.c.) 4.30.4 703.2; 703.3 1117B.5 .5 item 1, 1117B.5 .6 -PV - Public/Visitor Use D - Minor Code Deviation 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 90 Women's Restroom 16.12 - Other Door Requirements Door does not comply with all applicable ADAAG and CBC accessibility requirements. 4.13 404.1; Advisory 404.1 1133B.2 -Door stop.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 91 Women's Restroom 16.32A - U- Pulls at Stall Door The stall door does not have U-pulls on both sides. 4.13.9; 4.17.5 309.4; 404.27; 604.8.1. 2 1115B.3 .1(4.4) -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 92 Women's Restroom 16.33 - Self- Closing Stall Door The stall door is not self-closing.4.13.10 604.8.1. 2 1115B.3 .1(4.4) -PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 93 Women's Restroom 16.35C - Out- Swinging Stall Door - Approach Where the stall door swings out, the aisle approaching the stall is less than 60” deep. 4.17.5; 4.13.6; Fig. 25 404.2.4. 1; Fig. 404.2.4. 1 1133B.2 .4.2; Figs. 11B- 26A and 11B-26B -45 1/2" deep landing.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 94 Women's Restroom 16.40 - Stall Door Location - End-Opening Stall In an end-opening stall, the stall door is in front of the WC and not in front of the side transfer space. (ADA/CBC Standards require the door to be located in front of the side transfer space and diagonal to the WC, with a maximum stile width of 4".) 4.17.3; Fig. 30(a) 604.8.1. 2; Fig. 604.8.1. 2 1115B.3 .1(4.3); Fig. 11B-1A -9 1/2" stile.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 95 Women's Restroom Page 32 of 39 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 01 - Abalone Cove Shoreline ParkReporting: 200 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.49A - WC Flush Controls - Operation Water closet flush controls are not automatic or operable with one hand. (Accessible controls shall be operable with one hand, and without tight grasping, pinching, or twisting of the wrist, and the force to operate the controls shall be no greater than 5 lbs.) 4.16.5; 4.27.4 604.6; Advisory 604.6; 309.4 1115B.4 .1(5); Fig. 11B-1A -11 LBF.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 96 Women's Restroom 16.49B - WC Flush Controls - Location Flush controls are not located on the wide side of the WC where the clear floor space is provided. 4.16.5 604.6; Advisory 604.6 1115B.4 .1(5); Fig. 11B-1A -Center of W.C.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 97 Women's Restroom 16.50 - TP Dispenser - Location - Pre- 2007 CBC Facility Location of the toilet paper dispenser does not comply with the Standard in effect at the time of construction. (The 2001 CBC required toilet tissue dispensers located on the wall within 12" of the front edge of the toilet seat, measured to the centerline of the dispenser; mounted below the grab bar; and centered at a min. height of 19" AFF.) 4.16.6; Fig. 29(b) 604.7; Advisory 604.7; Fig. 604.7 --17" from W.C.PV - Public/Visitor Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 98 Women's Restroom 16.53 - SC Dispenser Height Mounting height of seat cover dispenser's highest operable part exceeds 40" AFF. 4.22.7; 4.27.3; 4.2.5; 4.2.6 -1115B.8 .3 -50 1/2" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 99 Women's Restroom 16.55A - Side Grab Bar Height Side grab bar is not centered at 33" AFF. (ADA Standards require side grab bars to be centered from 33" to 36" AFF; CBC Standards require side grab bars to be centered at 33" AFF.) 4.17.6; Figs. 29 & 30 604.5; Advisory 604.5; 604.5.2; Fig. 604.5.2; 609.4 1115B.4 .1(3.1); Fig. 11B-1A -33 1/2" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 100 Women's Restroom Page 33 of 39 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 01 - Abalone Cove Shoreline ParkReporting: 200 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.55B - Back Grab Bar Height - Non- Tank-Type WC At non-tank-type WC, back grab bar is not centered at 33" AFF. (ADA Standards require back grab bars to be centered from 33" to 36" AFF; CBC Standards require back grab bars to be centered at 33" AFF.) 4.17.6; Figs. 29 & 30 604.5; Advisory 604.5; 609.4 1115B.4 .1(3.2); Fig. 11B-1A -32 3/4" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 101 Women's Restroom 16.57 - Grab Bar Clearance Dispenser is located so that it obstructs the use of the grab bar, i.e. less than 18” above or within 1-1/2” below the tangent point of the grab bar. (Exception: When dispenser is recessed, flush with wall, and has no sharp edges.) 4.17.6, 4.26.2; Fig. 39 609.4 --10 1/2" Clear from seat cover dispenser. PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 102 Women's Restroom 16.71 - Lavatory - Rim Height Height of lavatory rim or counter surface exceeds 34” AFF. 4.19.2; Fig. 31 606.3 1115B.4 .3(2); Fig 11B- 1D -34 1/2" high.PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 103 Women's Restroom 16.76 - Lavatory - Clearance near Sidewall The centerline of the lavatory is not 18” min.. from the nearest sidewall or partition. --1115B.4 .3(2); Fig 11B- 1D -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 104 Women's Restroom 16.77 - Lavatory Location The lavatory's clear floor space does not adjoin or overlap an accessible path of travel. --1115B.4 .3(3) -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 105 Women's Restroom 16.78 - Pipe Insulation at Lavatory Drainpipes and hot water pipes are not insulated to protect against contact. 4.19.4 606.5 1115B.4 .3(4) -PV - Public/Visitor Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 106 Women's Restroom Page 34 of 39 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 01 - Abalone Cove Shoreline ParkReporting: 200 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.81 - Lavatory Faucet Operation - Min. 10 Second Standard Self-closing valve remains open for less than 10 seconds. 4.19.5 606.4 1115B.4 .3(1) -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 107 Women's Restroom 16.84A - Paper Towel Dispenser - Operating Height Mounting height of paper towel dispenser's highest operable part exceeds 40" AFF. (Where provided, ADA Standards require at least one paper towel dispenser to be accessible with the highest operable part placed within at least one of the reach ranges specified in 4.2.5 and 4.2.6; where provided, CBC Standards require at least one paper towel dispenser to be accessible with the highest operable part no higher than 40" AFF.) 4.22.7; 4.27.3; 4.2.5; 4.2.6 308; 309 1115B.8 .3 -PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 108 Women's Restroom 16.85A - Clear Floor Space at Dispensers There is no clear floor space at least 30” x 48” in front of the dispenser to allow either a forward or a parallel approach to the dispenser. (Where provided, at least one dispenser of each type shall be accessible.) 4.27.2; 4.2.4 305.3 1117B.6 (2); 1118B.4 -PTD reduces aisle to 28"PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 109 Women's Restroom 16.26A - Cross Slope Cross slope of the accessible route of travel exceeds 1:50. 4.3.7 403.3 1133B.7 .1.3 -2.8%PV - Public/Visitor Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 110 Women's Restroom 16.88 - Other - Toilet Facilities See Additional Comments ----Feminine dispenser protrudes 6" at 42" high. PV - Public/Visitor Use A - Safety Hazard 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 111 Women's Restroom 16.01 - Toilet Rooms Toilet room does not comply with all applicable ADAAG and CBC accessibility requirements. 4.1.2(6) ; 4.1.3(11 ); 4.22.1 213.2; Advisory 213.2 1115B.1 -Non compliant, room too small 40"x56" GS - General Student Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 144 Toilet Room Page 35 of 39 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 01 - Abalone Cove Shoreline ParkReporting: 200 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.07 - Clear Door Opening When the door is open 90 degrees, clear opening width is less than 32” measured between the face of the door and the doorstop on the latch side. 4.13.5 404.2.3 1133B.1 .1.1.1; 1133B.2 .2 -26 1/2"GS - General Student Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 145 Toilet Room 16.13C - Unisex RR Geometric Symbol Signage - Circle/Triangle Doorway leading to a unisex toilet room is not identified by a 12” circle, 1/4" with a 1/4" thick triangle superimposed and within the circle. OR Circle and triangle are provided, however they are accompanied by words in raised characters and Braille. (ADA and CBC Standards require a separate sign with raised characters and Braille mounted on the wall adjacent to the latch side of the door.) --1115B.6 -GS - General Student Use D - Minor Code Deviation 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 146 Toilet Room 16.15A - Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.30.1 216.2; 703.1; 703.2; 703.5 1117B.5 .1(1) -GS - General Student Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 147 Toilet Room 16.47A - WC Location from Sidewall The centerline of the WC is not 18” absolute from a wall or partition. 4.22.4 -1115B.4 .1(1) -20"GS - General Student Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 148 Toilet Room 16.49B - WC Flush Controls - Location Flush controls are not located on the wide side of the WC where the clear floor space is provided. 4.16.5 604.6; Advisory 604.6 1115B.4 .1(5); Fig. 11B-1A -GS - General Student Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 149 Toilet Room 16.72 - Lavatory Apron Clearance Lavatory does not provide accessible apron clearance (i.e. at least 29” clearance from the floor to the bottom of the apron). 4.19.2; Fig. 31 606.3 1115B.4 .3(2); Fig 11B- 1D -25 7/8" high.GS - General Student Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 150 Chair Storage Sink Page 36 of 39 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 01 - Abalone Cove Shoreline ParkReporting: 200 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.73 - Lavatory Knee Clearance Lavatory does not provide accessible knee clearance (i.e. at least 27” clearance from the floor to the underside of the lavatory, extending 8” min.. measured from the front edge underneath the lavatory back towards the wall). 4.19.2; Fig. 31 306.3; Fig. 306.3 1115B.4 .3(2); Fig 11B- 1D -24 1/2"GS - General Student Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 151 Chair Storage Sink 16.75 - Clear Floor Space at Lavatory There is no clear floor space at least 30” x 48” in front of the lavatory (extending a maximum of 19” underneath the lavatory) to allow a forward approach. 4.19.3; 4.2.4 606.2 1115B.4 .3(3); Fig 11B- 1D -28" wide.GS - General Student Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 152 Chair Storage Sink 16.82A - Mirror Height - Max. 40" AFF Standard Mirror above accessible lavatory or countertop is mounted so the bottom edge of the reflective surface is not 40” max.. AFF. (ADA Standards require at least one mirror to be accessible; CBC Standards prior to August 1, 2009 required all mirrors to be accessible. Effective August 1, 2009, amended CBC Standards require all mirrors above accessible lavatories or countertops to be accessible.) 4.19.6; Fig. 31 213.3.5; 603.3; Advisory 603.3 1115B.8 .1 -47 1/2" high.GS - General Student Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 153 Chair Storage Sink 16.48 - WC Seat Height The top of the WC seat is not between 17” and 19” AFF. 4.16.3; Fig. 29(b) 604.4 1115B.4 .1(4); Fig. 11B-1A -15 1/4"GS - General Student Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 154 Toilet Room 16.01 - Toilet Rooms Toilet room does not comply with all applicable ADAAG and CBC accessibility requirements. 4.1.2(6) ; 4.1.3(11 ); 4.22.1 213.2; Advisory 213.2 1115B.1 -EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 169 Lifeguard Sanitary Room 16.06 - Entry Doors Entry door does not comply with all applicable ADAAG and CBC accessibility requirements. 4.22.2 404.1 1115B.5 ; 1133B.2 -EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 170 Lifeguard Sanitary Room Page 37 of 39 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 01 - Abalone Cove Shoreline ParkReporting: 200 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.07 - Clear Door Opening When the door is open 90 degrees, clear opening width is less than 32” measured between the face of the door and the doorstop on the latch side. 4.13.5 404.2.3 1133B.1 .1.1.1; 1133B.2 .2 -EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 171 Lifeguard Sanitary Room 16.10 - Single- Action Hardware Handles, locks, and latches or other operative devices are not operable with one hand. OR They are not operable without tight grasping, pinching, or twisting of the wrist. (U-shaped handles, levers, and push/pull type mechanisms are acceptable designs.) 4.13.9 309.4; 404.2.7; Advisory 404.2.7 1133B.2 .5.2 -EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 172 Lifeguard Sanitary Room 16.13C - Unisex RR Geometric Symbol Signage - Circle/Triangle Doorway leading to a unisex toilet room is not identified by a 12” circle, 1/4" with a 1/4" thick triangle superimposed and within the circle. OR Circle and triangle are provided, however they are accompanied by words in raised characters and Braille. (ADA and CBC Standards require a separate sign with raised characters and Braille mounted on the wall adjacent to the latch side of the door.) --1115B.6 -EC - Employee Common Use D - Minor Code Deviation 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 173 Lifeguard Sanitary Room 16.15A - Providing Room/Space ID Sign A sign designating the permanent room or space has not been provided. 4.30.1 216.2; 703.1; 703.2; 703.5 1117B.5 .1(1) -EC - Employee Common Use B - Severe or Complete Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 174 Lifeguard Sanitary Room 16.47A - WC Location from Sidewall The centerline of the WC is not 18” absolute from a wall or partition. 4.22.4 -1115B.4 .1(1) -EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 175 Lifeguard Sanitary Room Page 38 of 39 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA Facility ID # 01 - Abalone Cove Shoreline ParkReporting: 200 of 4367 Rcds Author: Vaish, B City of Rancho Palos Verdes Compliance Report Rancho Palos Verdes ADA Assessment Group 16 - Toilet Facilities Item Name Description 1991 ADAAG 2004 ADAAG 2007 CBC 2005 PROWA Existing Condition Use#Severity Location TypeLocation 16.70 - Lavatories Lavatory does not comply with ADAAG and CBC requirements. (ADA Standards require at least one lavatory to be accessible. CBC Standards prior to August 1, 2009 required all lavatories to be accessible. Effective August 1, 2009, amended CBC Standards require at least 5% of lavatories, but not less than one lavatory, to be accessible.) 4.22.6 213.3.4; 606.1 1115B.4 .3 -EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 176 Lifeguard Sanitary Room 16.82A - Mirror Height - Max. 40" AFF Standard Mirror above accessible lavatory or countertop is mounted so the bottom edge of the reflective surface is not 40” max.. AFF. (ADA Standards require at least one mirror to be accessible; CBC Standards prior to August 1, 2009 required all mirrors to be accessible. Effective August 1, 2009, amended CBC Standards require all mirrors above accessible lavatories or countertops to be accessible.) 4.19.6; Fig. 31 213.3.5; 603.3; Advisory 603.3 1115B.8 .1 -EC - Employee Common Use C - Partial Barrier to Access 3 - Restroom Facilities (28 CFR 36.304(c)(3)) 177 Lifeguard Sanitary Room 69Number of Key Notes for Group 16 - Toilet Facilities: 200Number of Key Notes for Facility 01 - Abalone Cove Shoreline Park: 200Total Number of Key Notes for All Groups: Page 39 of 39 Printed 2013-05-09Application: ©2010 BOA Architecture - 877-225-4ADA