Loading...
RPVCCA_CC_SS_2013_05_21_02b_RPV_Street_Light_Acquisition_RetrofitCITY OF 4o RANCHO PALOS VERDES TO: FROM: DATE: HONORABLE MAYOR AND MEMBERS OF THE CITY COUNCIL COUNCILMAN JIM KNIGHT MAY 21,2013 SUBJECT:RPV STREET LIGHT ACQUISITION/RETROFIT RECOMMENDATION Direct staff to undertake a feasibility analysis of acquiring SCE owned street lights,retrofitting City owned lights with more energy efficient LED bulbs and explore re- setting SCE's rate structure as well as programs available for rebates and energy cost savings financing. COUNCILMAN SUMMARY Over the past year I have attended several workshops at the South Bay Energy Services Center (SBESC)covering current trends of cities taking control of their street light energy costs by a combination of acquiring SCE owned street lights,re-negotiating unmetered rates charged by SCE and changing out light fixtures to more efficient bulbs. I acquired a copy of our city's electric bill from staff and took note that the bill had one line item for "various"LS-1 lights (SCE owned,unmetered,all night)with an annual cost of over $300,000.The bill provided no way to identify where these poles were located,what type of bulbs were being used nor any accompanying documentation as to how SCE came up with their unmetered rate.This motivated me to dig a little deeper into our street lighting inventory and I was able to obtain a disk from SCE that listed our LS-1 and LS-2 (RPV owned,unmetered)street lights,but it was organized in a very disjointed fashion with over 70 different maps.The work to extrapolate the information and provide a full analysis was a daunting task requiring extensive expertise.So I am proposing that Council direct staff to pursue a feasibility analysis of pole acquisition,bulb replacement and explore with SCE the possibility of a re-negotiation of un-metered rates as well as potential rebate and/or financing programs. My suggested path is to divide the task into three phases: Phase I -Analyze utility bills and identify characteristics of individual poles: SS2b-1 RPV Street Light Acquisition/Retrofit May 21,2013 Page 2 of 5 1)Establish a full inventory and location of light poles to determine which are LS-1 and LS-2 while separating out street lights from RPV's facility use under the GS- 1(general service,non-demand rate),GS-2 (time of use)categories.Comments on age or condition of the pole/bulb should be included. 2)Identify poles that have ancillary uses such as cell phone towers,other utilities (cable,etc)or transitory wiring which may affect our ability to acquire the poles from SCE. 3)Identify the type of light fixture on each pole and energy/maintenance cost for each type of pole/bulb. 4).Understand the underlying methodology for the SCE pricing structure for each pole. NOTE:Our current Landscaping and Lighting maintenance contractor,Harris and Associates,has the technology to do the inventory.The inventory data should include 1-3 of the above list and delivered to us in a form that the data can be manipulated for our analysis.GS-1 ,2 for facility use,PA-1,2 (agriculture pumping,Le.,dewatering wells)and TC-1 (traffic lights)should be separable data. Phase II -Financial Feasibility Estimates 1)Calculate expected cost of acquisition of qualified poles and show any cost savings of RPV ownership vs.current LS-1 arrangement. 2)Calculate cost/benefit of bulb replacement from existing High Intensity Discharge (HID)lamps,such as High Pressure Sodium,with new LED or Induction technology,for both LS-1 acquired poles and existing LS-2 poles. 3)Compare operation and maintenance costs of existing light fixtures against LED replacement. 4)Look at re-negotiating un-metered rate structure. Phase III -Council Directive With the above feasibility analysis,Council gives direction as to what action (or no action)to take. ADDITIONAL INFORMATION Below is more information on the subject as well as assumptions made at the workshops I have attended and from reports of the Southern California Regional Energy SS2b-2 RPV Street Light Acquisition/Retrofit May 21,2013 Page 3 of 5 Center (SoCaIREC).I would ask staff to verify the information and analyze and refine,if needed,the assumptions when making their recommendation to Council adding any additional pertinent information and analysis. Purchase and Maintenance costs 1)Loaded pole purchase cost of $600/fixture (see discussion on cost basis/depreciation) 2)Retrofitting HPS to LED fixtures has a loaded One-Time Cost of $417 /fixture 3)Estimated operation and maintenance expenses are $3.50/pole/month for HPS and $1.50/pole/month once retrofitted to LED technology. Utility Owned lights SCE's recent change in policy allows municipalities to consider purchasing utility- owned street lights with substantial delivery rate savings by switching from LS-1 rates to LS-2 rates.Once city-owned,streetlights can be upgraded to LED (or Induction)with even greater savings. As with other cities that have embarked on this transition,SCE will require a formal Due Diligence and Appraisal Detailed inventory,with age and condition of facilities,and other indicators of value.SCE provides the city with a comprehensive report with a "not to exceed"estimate for asset transfer based on a sample.The City then receives approval to move forward with possible funding of a comprehensive study.RPV should compare the SCE report with our own inventory data. To determine acquisition value,SCE uses current replacement cost depreciated by the age and condition of the pole/light.But,as with real estate or most other commodities,a more appropriate method would be to start from the original installation cost as a basis,then depreciate the life/condition of the pole/light.This method produces a fairer value as it more closely reflects SCE's true cost per pole.No matter which method,the city's acquisition of the pole/light will benefit SCE by removing the future liability of the pole replacement cost off SCE's books.These are all points of negotiation with SCE. Acquisition costs will be lower if RPV transfers over the poles before SCE replaces the poles with new ones as we can take advantage of a depreciated evaluation. Tariff or SeE Rate Structure Street lights that are unmetered pay a tariff for distribution and a tariff for the lamp type.This rate decreases after the city acquires the pole from SCE (LS-1 converts to LS-2).The rate decreases even more with a bulb change (a reduction not available SS2b-3 RPV Street Light Acquisition/Retrofit May 21,2013 Page 4 of 5 under LS-1 status).In order to assure the rate reduction,the City must notify SCE of any change of bulb otherwise they will keep the old tariff rate. A General Rate Case settlement in 2013 is lowering some of the costs of LS-1 and LS-2 tariffs,freeing up immediate cash flow which can be used to justify retrofitting the streetlights this year.Also SCE has an Energy Leader Partners (ELP)program with rebate tiers based upon the status of the city.RPV is currently at the Gold status. Bulb characteristics LED lights have a more blue/white color than HPS.This feature,along with LED intensity,changes the visual characteristics on the ground.I would suggest before changing out all city bulbs that a few LED bulbs be installed at test locations to observe these ch~racteristics and watch for spill over into resident's backyards. Also,LED lights now come with a wide variety of choices including:light intensity,color,reflectivity,separable drivers,interchangeable LED subpanels,and focusing arrays to direct light without the need of a shield.Staff should consider these choices in relation to street illumination effects when recommending bulb replacement. LED savings Light Emitting Diode (LED)lamps show energy savings between 35%and 70% over HID lamps.(30-60%energy savings by switching to induction). Other advantages of LED: -Longer life,lower maintenance costs.LED lasts 80K hrs.and only needs to be replaced every 19.3 yrs vs.24K hrs.and 5.8 yrs.replacement cycle for HPS lamps -Higher quality light output -Instant-on with no run-up or re-strike delays -No mercury,lead or other known disposable hazards -Opportunity to implement programmable controls (e.g.bi-Ievellighting) SBEse assistance I have other resources I will forward to staff including The Responsible Purchasing Network (RPN)recommendations for street lights and a report from Huntington Beach's street light acquisition plan,but I feel the best source of assistance for RPV is using the services at SBESC. SBESC has a consulting service to help with analyzing financing for the acquisition of poles and bulb replacement by using energy cost savings without affecting the general fund budget.I have already been in touch with SBESC's consultant and,at no charge,he has provided a Cost-Benefit Analysis of LED Street Lighting Upgrade report for RPV (Attachment A). SS2b-4 RPV Street Light Acquisition/Retrofit May 21,2013 Page 5 of 5 The report shows: Table 1 - A breakdown of our LS-1,LS-2 inventory Table 2-Energy consumption per account Then several scenarios of cost savings: 1)Upgrading LS-2 fixtures 2)Analysis of purchasing LS-1 poles,then upgrading to LED technology 3)Combination of 1) and 2)together. The report includes a financing option (avoiding General Fund expenditures)and using energy cost savings as the driving force for the payback analysis.The low hanging fruit is scenario 1,upgrading existing LS-2 fixtures resulting in positive cash flow after one year. Staff can consult with SBESC to follow up and find out more about the consulting services for the feasibility study and rebate programs available. Attachment: South Bay Cities Council of Governments letter dated April 4,2013 regarding Cost- Benefit Analysis of LED Street Lighting Upgrade for Rancho Palos Verdes SS2b-5 ~ ~ ~ April,4,2013 SOUTH BAY CITIES COUNCIL OF GOVERNMENTS 5033 Rockvalley Road Rancho Palos verdes,CA 90275 (310)377·8987 sbccog @ southbay"itie~.&!:9 www.southbaycities.org Jim Knight City of Rancho Palos Verdes 30940 Hawthorne Blvd Rancho Palos Verdes,CA 90275 Subject:Cost-Benefit Analysis of LED Street Lighting Upgrade for Rancho Palos Verdes Dear Mr.Knight: The South Bay Environmental Services Center (SBESC)is pleased to provide you with the enclosed summary of an initial cost-benefit anaJysisof upgrading the City's street lights to a more efficient lighting technology.Following today's workshop,the SBESC staff will schedule a one-on-one consultation with you to further review the cost-benefit analysis and make necessary adjustments to assumptions and results based on your input.The following baseline information in Tables 1 and 2 was collected and used by SBESC in our analysis.The existing street light inventory for the City's SCE accounts is listed below. Table 1.Rancho Palos verdes Street Lamp Inventory Fixture Wattages1 sow 70W 100W 150W 200W 250W 400W Total #'of Poles LS-1 2 o 256 24 118 24 7 2,376 #of POles LS_2·3 o o 8 o 8 20 7 43 #ofPo'les LS-3 4 o o o o o o o o #ofPc>les Total o 256 1,955 24 126 44 14 2,419 1.All fixtures are assumed to be High Pressure Sodium fixtures. 2.Utility-owned poles,unmetered. 3.City-owned poles,unrnetered. 4.City-owned poles,metered. LOCAL GOVERNMENTS IN ACTION Carson Los Angeles EI Segundo Gardena Hawthorne Hermosa Beach Inglewood Lawndale Lomita Manhattan Beach Palos Verdes Estates Rancho Palos Verdes Redondo Beach Rolling Hills Rolling Hills Estates Torrance Los Angeles County SS2b-6 The total annual energy consumption and cost for all street lights is summarized below. Table 2.Annual Energy Consumption and Costs per Account Type. Rate #of Accts Cost ($)kWh LS+ALLNITE 4 $349,844 1,166,306 LS·2 LS·3 2 a $5,235 o 55,272 o Total 6 $355,078 1,221,578 The SBESC evaluated three potential retrofit project scenarios for the City of Rancho Palos Verdes.The assumptions and results for each scenario are as follows: 1.Upgrading existing LS-2 fixtures to LED technology. Assumptions Loaded Cost of SCE Poles IS/pole):So Project Finance Rate (%):3.90% Finance Period (yrs):15 Pole Replacement Reserve (per pole/rna):$0.60 SCE Tariff Escalation Rate (%/yr):3.00% O&M,Repairs,Replacemeht Esc.Rate (%/yr):3.·00% Discount Rate (%):2.00% HPSO&M Cost (S/pole/mo):S3.50 LED Retrofit O&M (S/pole/mo):S1.50 Results Cost of SCE Poles ($):$0 LED Installation Costs ($):$21,921 SCE Incentive Amount ($):$2,809 Loan Amount ($):$19112 Positive Cash Flow Begins in Year:1 Base Case PV ($):$115,789 Proposed Case PV ($):$78,106 20-year NPV Savings ($):$37,682 2.Purchasing LS-l poles from SCE and then upgrade to LED technology. Assumptions Loaded Cost of SCE Poles ($/pole):S600 Project Finance Rate (%):3.90% Finance Period (YfS):15 Pole Replacement Reserve (per pole/rna):SO.60 SCE Tariff Escalation Rate (%fyr):3.00% O&M,Repairs,Replacement Esc.Rate (%/yr):3.00% Discount Rate (%):2.00% HPS O&M Cost (S/pole/mo):S3.50 LED Retrofit O&M (S/pole/mo):$1.50 SS2b-7 Results Cost of SCE Poles ($):$1,425,600 LED Installation Costs ($):$979,784 SCE Incentive Amount ($):$91,846 Loan Amount ($):$2,313,538 Positive Cash Flow Begins in Year:11 Base Case PV ($):$7,041,201 proposed Case PV ($):$6,307,854 20-year NPV Savings ($):$733,347 3.Both Scenarios 1 and 2 together. Assumptions Loaded Cost of SCE Poles (S/pole):$600 Project Finance Rate (%):3.90% Finance Period (yrs):15 Pole Replacement Reserve (per pole/mo):SO.60 SeE Tariff Escalation Rate (%/yr):3.00% O&M,Repairs,Replacement Esc.Rate (%/yr):3.00% Discount Rate (%):2.00% HPS O&M Cost ($/pole/mo):$3.50 LED Retrofit O&M ($/pole/mo):$1.50 Results Cost of SCE Poles ($):$1,425,600 LED Installation Costs ($):$1,001,705 seE Incentive Amount ($):$95,421 Loan Amount ($):$2,331,884 Positive Cash Flow Begins in Year:11 Base Case PV ($):$7,183,501 Proposed Case PV ($):$6,411,576 20-year NPV Savings ($):$771,925 We look forward to working together with you in pursuing these potential cost savings opportunities . Sincerely, The SBESC Staff #.p;\fV ._---------_..---_- DAVID MAGARIAN,LEED A.P. ENVIRONMENTAL PROGRAMS SPECIALIST SOUTH SAY ENVIRONMENTAL SERVICES CENTER South Bay Cities Council of Governments Save Water,Energy,Money &the Environment 20285 S.WESTERN AVE ..STE.100 TORRANCE.CA 90501 (310)371·7222 EXT,210 (; CELL (310)612·0894 DAVID.MAGARIAN@SBESC.COM WWW.SBESC.COM SS2b-8