Loading...
03_20141028_PC_PPT_Public_Green_Hills_ResidentM' 0 0 - CD I W N cc O C S:Im Whit was approved by the Planning Commission isn't what was built... 214..33' to Pllaster 21 1' to ray Area 194.00' FIN GRADE 217.00' flax H-uight to Pilaster 213.5' to Gross 1 89.82' FIN GRADE 15.0' ut Roud level The Mausoleum is 5.05ft higher than permitted per COA #38 of the CUP } COA # 38 states the following: "With the exception of the mausoleum building on Inspiration Slope, all mausoleum ,buildings shall not exceed 20 -feet in height as measured from the average elevation of the finished grade at the front of the ,building to the highest point of the structure and 30 -feet when measured from the lowest finished grade adjacent to the building to the highest point of the structure." Average Elevation of Finished Grade at front of structure: 0 94.00+1 89.82)/2= 191.91 ft Highest Point of Structure per Building Height Certification: 216.96fy 21 6.96ft-1 91.91 ft=25.05ft (Maximum of 20ft allowed per the COA #38) The Mausoleum is 5.05ft higher than allowed per condition #38 of the CUP 3 Cn 0 0 0 - CD N 00 CDCD } COA # 38 states the following: "With the exception of the mausoleum building on Inspiration Slope, all mausoleum ,buildings shall not exceed 20 -feet in height as measured from the average elevation of the finished grade at the front of the ,building to the highest point of the structure and 30 -feet when measured from the lowest finished grade adjacent to the building to the highest point of the structure." Average Elevation of Finished Grade at front of structure: 0 94.00+1 89.82)/2= 191.91 ft Highest Point of Structure per Building Height Certification: 216.96fy 21 6.96ft-1 91.91 ft=25.05ft (Maximum of 20ft allowed per the COA #38) The Mausoleum is 5.05ft higher than allowed per condition #38 of the CUP 3 "25' from lowest point of adjacent grade to highest point of mausoleum" W, OUTLINE OF EXISTING 13FL0.DE CEMETERY ROAIDWAY MEZZANINE LEVEL 50HMi ATIC, 51TE SECTION / INE5T AIN6 47" 1401 GUARDRAIL NEW GRADEraITOUND BURIALS GROUND B URIALS AT UE22AMNE LEVEL J.5'I'irAWr70 DD INC:- MASTER DEVELOPMENT PLAN MASTER FLAN AREA 11 AI WCHITEC IPUIlfi GREEN HILLS MEMORIAL PARK MEMORIAL TERRACE WEST WING �P INTERIORS PANCHO PALOS VERDES, CALIFORNIA PIAN N INC. LL`5 DSCAPF .A4uaRx 20.2007047M 11—D asi� lS % W IV O O � _r=EM 4 1 III ., 0 Cr CD US.. W N cc O C RMEM Mausoleum is 2.1 4ft higher than allowed per Master Plan Revision Booklet Lowest point of adjacent grade: 189.82ft Highest point of structure per building height certification: 216.96ft 216.96ft - 189.82ft = 27.14ft (Maximum of 25ft according to Master Plan Revision Booklet) The Mausoleum was built higher than allowed according to this measurement as well 5 1 III ., 0 Cr CD n .. W N cc O RMEM What was built wasn't what was approved by the Planning Commission. The approved Schematic Site Sections for the Mausoleum show the Mausoleum not exceeding the height of the existing grade. The Mausoleum was depicted to the Planning Commission as being built into a hill. The existing grade is also misrepresented as being at least 40ft high A 0 a - CD le •^. a) N CQ C:) CD tN\ Existing Grade shown as dotted line. Mausoleum Height doesn't exceed it 111- "INE LEVET w True Existing Grade r OUTLINE OF EXISTING dDE SCHEMATIC SITE 5ECTION / HEST AIN6 42" plow GUARDRAIL NEW GRRDE+OROUND BURIALS ^—G OUNDBURIALS ATMF72ANINELEVE 40ft No retaining wall here J 4 [ LrAWr 70DD INC:. MASTER DEVELOPMENT PLAN MASTER PLAN AREA 11 W [1111 "I1 41 GREEN FULLS MEMORIAL PARK MEMORIAL TERRACE WEST WING IN'nA I# nR,, HANCHO PALOS VERDES, CALIFORNIA 10tj p [4_I-NN[N[. f_lN I i4{;AP ,.A+IURR�" 26.2u7i 11-D o-xr,� 0 0 - CD ruilotAw a) N cQ O (D 5. EXISTING GRADE — 50H'EM^TlC SITE 5EGTION ZOff 11.0 Mld OUTLINE OF MALPSDI_EUM s S ., 0 Cr CD 1. •• W N cc O C X0=RM The western pre-existing grade was extremely misrepresented in the 2007 Master plan revision booklet. It wasn't 40ft tall with a 45 degree slope... not even close! Pre-existing grade was FLAT in front of Vista Verde I'M NO, 0 0 0 - CD N CD O --L " �-Z12 Master Plan Revision Booklet Incorrectly states a "net cut" grading plan West of Mausoleum. Makes it appear as if Mausoleum Was being built into an existing hill Tons of Dirt brought in. Land raised by approx. 1 4ft in this area! 1 S4] I[Y ni 1 l 10 Row of internments placed too close to property line � The Mausoleum wasn't built into a Hill , Grade was raised by approximately 14ft to the west of the Mausoleum. Pre existing grade was level with the road Cn o a_ 0 ' CD Mausoleum also was built higher CD CD approved by the Planning ®..r