01_20141202_Lilley_Planning_Group_Memo_re_RPV_PC_Height_ConfirmationPLANNING GROUP MEMORANDUM Date: December 2, 2014 To: Acting City Manager From: Lilley Planning Group Subject: Third Party Peer Review — REVISED Green Hills Memorial Park: Compliance Review for Conditional Use Permit No: 155 — Green Hills Master Plan 1991-2007 — Present Pursuant to direction received at the Planning Commission meeting on October 28, 2014, the following information regarding the height of the Mausoleum in Area 11 (Memorial Terrace aka Pacific Terrace) has been obtained: City of Rancho Palos Verdes Construction plans signed by both the city planner and the building official dated February 6, 2012 and Building Height Certification signed by a licensed land surveyor dated January 18, 2013. This information has been provided to confirm compliance with conditions of approval for building height, for Area 11 specifically. 36. The overall building heights for the mausoleums are limited to the heights depicted in the Master Plan Revision booklet described in condition No. 1 above. The heights of each mausoleum building shall be certified by a registered Civil Engineer and submitted to the Planning, Building and Code Enforcement Department prior to building permit final. Former Response: No height certification records were in the material provided for review. The condition is not in compliance. Current Response: The construction plans and height certification do not match the Area 11 Mausoleum depicted in the Master Plan Revision booklet. Sheet 11-D of the Master Plan booklet shows a schematic site section for the west wing of the Memorial Terrace / Pacific Terrace with a 25 foot maximum building height but appears to have a 40 -foot rear retaining wall. This condition is not in compliance. 38. With the exception of the mausoleum building on Inspiration Slope, all mausoleum buildings shall not exceed 20 -feet in height as measured from the average elevation of the finished grade at the front of the building to the highest point of the structure and 30 - feet when measured from the lowest finished grade adjacent to the building to the highest point of the structure. 1 Former Response: Inspiration Slope is currently under construction and will be certified for height once framing is completed. An additional compliance inspection is required. Height certifications for other structures could not be located in the record provided. The condition is not in compliance. Current Response: In the "General Development Parameters," pages I and 11 of the Narrative of the Master Plan booklet, it states "Building heights are calculated based on building frontage being the elevation of the individual mausoleums that faces the internal cemetery road system. Heights listed on the color elevations conform to the requirements listed in Condition No. 35 in resolution No. 91-7. The dimensions are shown for the overall height of each mausoleum as measured from the average adjacent grade (not to exceed 20'0) and the overall height of each mausoleum as measured from the lowest adjacent grade (not to exceed 25'-0"0). The Condition in Resolution No. 91-7 reads as follows: "35. Future buildings designated on the Land Use Plan shall not exceed 20 feet in height as measured from the average elevation of finished grade at the front of the building to the highest point of the structure and 25 feet when measured from the lowest finished grade adjacent to the building, to the highest point of the structure." On March 23, 1995, the Planning Commission approved Conditional Use Permit No. 155 Revision "A" to allow structures in the Green Hills Master Plan to have a maximum downslope height of 30 feet. Yet, Condition No. 38 in the 2007 Resolution adopting Revised Green Hills Master Plan states — "With the exception of the mausoleum building on Inspiration Slope, all mausoleum buildings shall not exceed 20 -feet in height as measured from the average elevation of the finished grade at the front of the building to the highest point of the structure and 30 -feet when measured from the lowest finished grade adjacent to the building to the highest point of the structure." It appears the language regarding the 30 - feet in height was carried over into the conditions, but not into the Master Plan Revision Booklet. The result is inconsistencies in how height is calculated and whether or not the maximum height was supposed to be 25 feet or 30 feet. If 30 feet is the rule, the mausoleum still does not comply with the 30 -foot height limit*: 217.00' Top of guardrail 185.00' Finished grade 32.0' *The certified height of the building was slightly under 217.00'.It appears the certification was taken from finished floor not finished grade as required by the condition. The structure also does not comply with the 20 -foot height limit: 217.00' Top of guardrail 189.50' Average grade at front of building 27.5' DOCUMENTS FOR REVIEW: a. Peer Review Description. City b. Building Permit for Memorial Terrace Mausoleum dated, 02/06/12 c. Building Plans for the Memorial Terrace Mausoleum signed by the planner and building official d. Elevation Certificates signed and dated by a licensed surveyor e. Planning Application — Green Hills Memorial Cemetery f. 1991 Staff Report and Resolution for CUP No. 155 and VAR No. 262 — Adoption of Green Hills Master Plan g. 2007 Staff Report, Environmental Document and Resolutions for Adopting Revised Green Hills Master Plan h. All Planning documents for 27501 Western Avenue - Green Hills Memorial Cemetery from the 1980s to present i. 2007 Master Plan Revision booklet According to City correspondence, these documents constitute the whole of the permit record for this property. 3