Loading...
PC RES 2006-060 P.C. RESOLUTION NO. 2006- RESOLUTION F THE PLANNINGCOMMISSION OF THE CITY OF RANCHOL APPROVING CONDITIONAL PERMIT REVISION ING APPROVAL(CASE NO. N200 -0060)FOR NEW 8,479-SQUARE-FOOT 2-STORY SINGLE-FAMILY RESIDENCE AND 53 CUBIC YARDS F RELATED GRADING, LOCATED AT 3231 PALPALOS VERDES DRIVE SOUTH WHEREAS, on July 12, 1977, Conditional Use Permit No. 23 (CUP 23) was approved by the Planning Commission to establish the Seacliff Hills community as a residential planned development (RPD), which included the approval of specific building footprints and limits of grading for each of the fifty-seven (57) approved residential lots; and, WHEREAS, on December 22, 2005, the applicant, Vinod Jindal, submitted an application for a revision to CUP 23 and a grading approval (Case No.ZON2005-00660)to allow the development of a new single-family residence on a vacant upslope lot in the Seacliff Hills community which deviated from the approved building footprint and limits of grading; and, WHEREAS, on October 13, 2006, the application was deemed complete for processing by Staff; and, WHEREAS, pursuant to the provisions of the California Environmental Quality Act, Public Resources Code Sections 21000 et. seq. ("CEQA"), the State's CEQA Guidelines, California Code of Regulations, Title 14, Section 15000 et. seq., the City's Local CEQA Guidelines, and Government Code Section 65962.5(f)(Hazardous Waste and Substances Statement), Staff found no evidence that the approval of the requested conditional use permit revision and grading approval would have a significant effect on the environment and, therefore, the proposed project has been found to be categorically exempt (Section 15303(x)); and, WHEREAS, after notice issued pursuant to the requirements of the Rancho Palos Verdes Development Code, the Planning Commission held a duly noticed public hearing on November 28, 2006, at which time all interested parties were given an opportunity to be heard and present evidence. NOW, THEREFORE,THE PLANNING COMMISSION OF THE CITY OF RANCHO PALOS VERDES DOES HEREBY FIND, DETERMINE, AND RESOLVE AS FOLLOWS: Section 1. The Planning Commission makes the following findings of fact with respect to the request for a revision to Conditional Use Permit No. 23 to deviate from the approved building footprint and limits of grading for Lot 26 of Tract No. 34834 in the Seacliff Hills community: A. The site for the intended use is adequate in size and shape to accommodate said use. Pursuant to CUP 23, this lot was originally approved for a 4,350-square-foot, multi-level single-family residence resulting in 13-percent lot coverage. The proposed 8,479-square-foot 2-story single-family residence is located in roughly the same position on the lot as the originally-approved residence, and would result in 28-percent lot coverage. The maximum permitted lot coverage for an upslope lot such as this is twenty-five percent(25%). However,the existing fire lane constitutes 4-percent lot coverage, so the applicant's proposal by itself is consistent with the 25- percent lot coverage standard. The proposed project meets all of the required setbacks for this lot. B. The site for the proposed use relates to streets and highways properly designed to carry the type and quantity of traffic generated by the subject use. The subject property is served by an existing private driveway that is also shared with Lots 24 and 25 of Tract No.34834 (3239 and 3235 Palos Verdes Drive South, respectively). This driveway also will serve as a fire lane for these three (3) lots. C. There will be no significant adverse effect on adjacent property or permitted uses. The subject property is located adjacent to the "Switchbacks" area of the City's Natural Communities Conservation Planning (NCCP) preserve. The applicant prepared a biological survey of the site to identify the presence of any existing sensitive plant or animal species, and to determine if the project would have direct or indirect effects upon habitat areas within the NCCP preserve. The biological survey found that the project would result in no direct or indirect impacts to habitat on site or in the adjacent NCCP preserve. Five (5) project-specific mitigation measures were recommended by the applicant's biologist, which are included as conditions of approval. The City's biological consultant reviewed the applicant's biological survey and approved it on September 7, 2006. The only other adjacent properties are the two (2) vacant residential lots (Nos. 24 and 25) that share the existing private driveway with the subject property. The development of the subject property will have no adverse impacts upon these vacant lots. D. The proposed use is not contrary to the General Plan. The General Plan land use designation for the subject property is Residential, <1 DU/acre. The development and improvement of single-family residences are among the primary permitted uses within this land use designation. This is also reflected in Housing Activity Policy No. 3 of the General Plan (p. 78), which calls upon the City to "[encourage] and assist in the maintenance and improvement of all existing residential neighborhoods so as to maintain optimum local standards of housing quality and design." E. The easterly portion of the subject property,which forms the west bank of Upper La Rotonda Canyon, is subject to the Natural (OC-1) and Urban Appearance (OC-3) overlay control districts, as established pursuant to Sections 17.40.040 and 17.40.060, respectively, of the City's Development Code. This portion of the P.C. Resolution No. 2006-60 Page 2 of 11 property is designated as a flood hazard area on Tract Map No. 34834, and no development is proposed within this area. The proposed project is consistent with all of the performance criteria established for properties affected by the OCA and OC-3 overlay districts. F. Conditions have been imposed to protect the health, safety and general welfare, which include a number of conditions of approval to ensure the consistency of the project with the Seacliff Hills Development Guidelines, the NCCP preserve, the OCA and OC-3 overlay control districts, and other conditions, as identified in Exhibit 'A' attached hereto. Section 2: The Planning Commission makes the following findings of fact with respect to the request for a grading approval for 964 cubic yards of grading associated with the construction of a 8,479-square-foot 2-story single-family residence: A. The grading does not exceed that which is necessary for the permitted primary use of the lot. Based upon the underlying RS-1 zoning designation, the primary permitted use of the property is for single-family residential development. Most of the proposed grading is for cut (627 CY)that is mostly within the building footprint. A relatively small amount of fill (226 CY) is proposed, roughly three-quarters of which is proposed on the slope in the front-yard setback area. The total grading quantity (853 CY) is below the 1,000-cubic-yard threshold established by the Seacliff Hills Development Guidelines. B. The proposed grading and/or related construction does not significantly adversely affect the visual relationships with nor the views from the "viewing area" of neighboring properties. The proposed project falls within the "by right" height limit for upslope lots. The highest point of the roof will be only about four feet six inches (4'-6") higher than the roadway surface at the top of the existing private driveway "hammerhead" turnaround. The adjacent vacant residential lots that share this driveway are at higher elevations, so the proposed project should have no significant impact upon their views. Finally,the grade within the building footprint is being lowered such that the residence will be lower than a similar structure that could have been built in the same location based upon the preconstruction grade. C. The nature of the grading minimizes disturbance to the natural contours and finished contours are reasonably natural. The existing "natural" contours of the project site are largely the result of past grading for the development of the Seacliff Hills neighborhood and the construction of the existing driveway/fire lane. With the exception of the building footprint, the driveway and some fill at the front of the house, the topography of the remainder of the site will remain unaltered. D. The grading takes into account the preservation of natural topographic features and appearances by means of land sculpturing so as to blend any man-made or P.C. Resolution No. 2006-60 Page 3 of 11 manufactured slope into the natural topography. As mentioned above,the existing "natural" contours of the project site are largely the result of human alteration in the past. There are no significant natural topographic features that would be disturbed by the proposed grading. E. The proposed project is compatible with the character of the twenty (20) nearest homes in the immediate neighborhood in terms of its size, scale, bulk and mass, lot coverage, architectural style and setbacks. F. The proposed project is not a new residential tract, so the required finding that the grading includes provisions for the preservation and introduction of plant materials so as to protect slopes from soil erosion and slippage and minimize the visual effects of grading and construction on hillside areas is not applicable in this case. G. The proposed project does not involve modifications to streets or other public infrastructure, the required finding that the grading utilizes street designs and improvements which serve to minimize grading alternatives and harmonize with the natural contours and character of the hillside is not applicable in this case. H. The proposed project would not cause excessive and unnecessary disturbance of the natural landscape or wildlife habitat through removal of vegetation. The biological survey for the proposed project indicates the presence of 0.41 acre of disturbed, unoccupied coastal sage scrub (CSS)and southern cactus scrub (SCS) habitat on the front and easterly side slopes of the property. No grading or development is proposed in these areas, and they will be protected during construction and fenced off from the remainder of the lot once the house is built. 1. The grading conforms to certain City standards for grading on slopes, creation of new slopes, heights of retaining walls, and maximum driveway steepness. Specifically, new slopes will not exceed 35-percent steepness; only one 5-foot-tall upslope retaining wall is proposed;and the maximum driveway slope will not exceed 20-percent steepness. J. Pursuant to Section 17.76.040(E)(9)(c) of the Rancho Palos Verdes Development Code, the proposed 11-foot depth of cut is reasonable and necessary to correct previous grading and to allow the proposed house to be set down into the grade of the lot. K. Deviations from certain City standards for the number an height of upslope retaining walls adjacent to the driveway are warranted. Specifically,two(2)upslope retaining walls—one 3-foot-tall and one 6-foot-tall—are proposed on the north side of the driveway. These deviations are warranted because: P.C. Resolution No. 2006-60 Page 4 of 11 L The criteria of subsections (E)(1) through (E)(8) of RPVDC Section 17.76.040(E) are satisfied. ii. The approval is consistent with the purposes set forth in subsection A of the City's grading regulations, which stated purpose is to "[permit] reasonable development of land..."; to "[ensure] that the development of each parcel of land—occurs in a manner harmonious with adjacent lands..."; and to "[ensure] that each project complies with the goals and polices of the General Plan...." The proposed grading and retaining walls are consistent with these purposes because they will allow reasonable use of the property, will not adversely affect surrounding properties, and will be consistent with the Residential <1 DU/acre land use designation for the area. iii. Departure from the standards in subsection (E)(9)will not constitute a grant of special privileges inconsistent with the limitations upon other properties in the vicinity. Two (2) upslope retaining walls are proposed adjacent to the driveway. These walls are necessary to support the existing private driveway/fire lane and to provide access to the lower-level garage of the house. At their highest point the upper wall is six feet (6'-0") tall and the lower wall is three feet (3'-0") tall, but both walls taper and eventually "daylight" into the existing grade. A planter area that will provide visual screening of the tallest portion of the upper wall separates the walls. Many of the other homes in the immediate neighborhood that have been built on upslope lots have similar walls along their driveways. iv. Departure from the standards of subsection (E)(9)will not be detrimental to the public safety nor to other property. The City's geotechnical consultant has granted conceptual approval of the project, and additional review and analysis will be required before the soil engineering report for the grading, retaining walls and structure is granted final approval for construction. The applicant will also be required to obtain a building permit for the project, including the review of site drainage. Section 3: Any interested person aggrieved by this decision or by any portion of this decision may appeal to the City Council. Pursuant to Sections 17.60.060 and 17.76.040(H)of the Rancho Palos Verdes Municipal Code, any such appeal must be filed with the City, in writing, setting forth the grounds of the appeal and any specific actions requested by the appellant, and accompanied by the appropriate appeal fee, no later than fifteen (15)days following November 28, 2006, the date of the Planning Commission's final action. Section 4: For the foregoing reasons and based on information and findings contained in the Staff Reports, minutes, and records of the proceedings, the Planning Commission hereby approves Case No. ZON2005-00660 for a conditional use permit P.C. Resolution No. 2006-60 Page 5 of 11 revision and grading approval for a new 8,479-square-foot 2-story single-family residence and 853 cubic yards of related grading, located at 3231 Palos Verdes Drive South, subject to the conditions of approval contained in the attached Exhibit W, attached hereto and made a part hereof, which are necessary to protect the public health, safety, and welfare. PASSED,APPROVED, AND ADOPTED this 28 to day of November 2006, by the following vote: AYES: Commissioners Karp, Ruttenberg and Tetreault, Vice Chairman Gerstner NOES: none ABSTENTIONS: none ABSENT: Commissioners Lewis and Perestam, Chairman Knight Bill Gerstner Vice Chairman Joel A'CP Direct r f PI Dire lanni g, wilding a C I gi and EnforcL nt; and, Secretary to the Planning Commission P.C. Resolution No. 2006-60 Page 6 of 11 EXHIBITW CONDITIONS OF APPROVAL FOR PLANNING CASE NO. ZON2005-00660 (Jindal, 3231 Palos Verdes Drive South) General Conditions: I Prior to the submittal of plans into Building and Safety plan check,the applicant and the property owner shall submit to the City a statement, in writing, that they have read, understand, and agree to all conditions of approval contained in this Resolution. Failure to provide said written statement within ninety (90) days following date of this approval shall render this approval null and void. 2. Approval of this permit shall not be construed as a waiver of applicable and appropriate zoning regulations, or any Federal, State, County and/or City laws and regulations. Unless otherwise expressly specified, all other requirements of the City of Rancho Palos Verdes Municipal Code shall apply. 3. This approval is for the construction of a 8,479-square-foot 2-story single-family residence and 853 cubic yards of related grading. The Director of Planning, Building and Code Enforcement is authorized to make minor modifications to the approved plans and any of the conditions of approval if such modifications will achieve substantially the same results as would strict compliance with the approved plans and conditions. Otherwise, any substantive change to the project shall require approval of a revision to the conditional use permit and/or grading approval by the Planning Commission and shall require new and separate environmental review. 4. All project development on the site shall conform to the specific standards contained in these conditions of approval or, if not addressed herein, in the RS-1 district development standards and the OC-1 and OC-3 overlay control district performance criteria of the City's Municipal Code. 5. Failure to comply with and adhere to all of these conditions of approval may be cause to revoke the approval of the project by the Planning Commission after conducting a public hearing on the matter. 6. If the project has not been established (i.e., building permits obtained) within one year of the final effective date of this Resolution, or if construction has not commenced within one hundred eighty (180) days of the issuance of building permits, approval of the project shall expire and be of no further effect unless, prior to expiration, a written request for extension is filed with the Department of P.C. Resolution No. 2006-60 Page 7 of 11 Planning, Building and Code Enforcement and approved by the Director. Otherwise, a conditional use permit revision and/or grading approval revision must be approved prior to further development. 7. In the event that any of these conditions conflict with the recommendations and/or requirements of another permitting agency or City department, the stricter standard shall apply. 8. Unless otherwise designated in these conditions, all construction shall be completed in substantial conformance with the plans stamped APPROVED by the City with the effective date of this Resolution. 9. The construction site and adjacent public and private properties and streets shall be kept free of all loose materials resembling trash and debris in excess of that material used for immediate construction purposes. Such excess material may include, but not be limited to: the accumulation of debris, garbage, lumber, scrap metal, concrete asphalt, piles of earth, salvage materials, abandoned or discarded furniture, appliances or other household fixtures. 10. Permitted hours and days for construction activity are 7:00 AM to 7:00 PM, Monday through Saturday,with no construction activity permitted on Sundays or on the legal holidays specified in Section 17.96.920 of the Rancho Palos Verdes Development Code. Trucks and other construction vehicles shall not park, queue and/or idle at the project site or in the adjoining public rights-of-way before 7:00 AM, Monday through Saturday, in accordance with the permitted hours of construction stated above. 11. A minimum 3-car garage shall be maintained, with each required parking space being individually accessible and maintaining minimum unobstructed dimensions of 9° in width and 20° in depth, with minimum 7° vertical clearance. 12. Notwithstanding the proposed plans, any fence located between the front property line (i.e., the northerly edge of the public right-of-way of Palos Verdes Drive South and the closest portion of the house shall be limited to forty-two inches (42") in height, unless an application for a minor exception permit for a taller fence (6-foot- tall maximum) is approved by the Director of Planning, Building and Code Enforcement in conjunction with the site landscape plan. 13. All site landscaping and other improvements shall be installed and maintained in compliance with the applicable performance criteria of the Natural (OC-1) and Urban Appearance(OC-3)Overlay Control Districts,which apply to the flood hazard area in the easterly portion of the property along Upper La Rotonda Canyon. P.C. Resolution No. 2006-60 Page 8 of 11 14. Exterior residential lighting shall be in compliance with the standards of Section 17.56.030 of the Rancho Palos Verdes Development Code, and shall not exceed 2,000 W incandescent(or equivalent). No single lighting fixture may exceed 150 W incandescent (or equivalent). 15. The applicant shall obtain an encroachment permit from the Director of Public Works for any other temporary or permanent improvements or activities within the public right-of-way of Palos Verdes Drive South. Condition Use Permit Revision Conditions: 16. This approval is for a 8,479-square-foot,2-story single-family residence. BUILDING AREA CERTIFICATION REQUIRED,to be provided by a licensed land surveyor or civil engineer prior to building permit final. 17. The maximum ridgeline of the approved project is 109.50'. BUILDING HEIGHT CERTIFICATION REQUIRED, to be provided by a licensed land surveyor or civil engineer prior to roof sheathing inspection. 18. The approved residence shall maintain setbacks of 40'front, 20' rear, 12'west side and 76' east side. BUILDING SETBACK CERTIFICATION REQUIRED, to be provided by a licensed land surveyor or civil engineer prior to foundation forms inspection. 19. The approved project shall maintain a maximum of 28% lot coverage as calculated pursuant to the Seacliff Hills Development Guidelines. Maximum hardscape coverage within the 20-foot front-yard setback area shall not exceed 50%. 20. Prior to Building Permit issuance, the applicant shall submit a site landscape plan for the review and approval of the Director of Planning, Building and Code Enforcement. Said plan shall include any proposed walls or fences in accordance with the Seacliff Hills Development Guidelines. The landscape plan should be designed to: a. Screen buildings from Palos Verdes Drive South; b. Soften architectural features; C. Improve the transition between open space areas and buildings; d. Stabilize slopes; and, e. Emphasize the use of drought-tolerant plantings. P.C. Resolution No. 2006-60 Page 9 of 11 All project site landscaping shall be installed within ninety (90) days of building permit final. 21. As identified in the July 2006 Biological Resources Report and Impact Analysis prepared for the project by Dudek: a. The native habitat on-site (including disturbed coastal sage scrub and disturbed southern cactus scrub) that is considered suitable for sensitive species shall not be directly impacted by the project in any way. b. A fence shall be erected between the residence and the native habitat areas in the southerly and easterly portions of the subject property. C. Standard construction best management practices(BMPs)and construction- related minimization measures to control dust, erosion and runoff shall be implemented to minimize indirect effects during construction. d. To mitigate for the potential introduction of the Argentine ant into on-site disturbed coastal sage scrub and disturbed southern cactus scrub habitat, where the coast (San Diego) horned lizard has a moderate potential for occurring, the applicant shall: L Ensure that all plant material used in landscaping on-site in inspected for the presence of the Argentine ant; ii. Use drought-tolerant landscaping along the open space interface; and, iii. Design the landscaping such that there is an interception and diversion of urban run-off away from the open space areas. e. If construction activity is to take place during the breeding season (i.e., January through September), a one-time biological survey for nesting bird species shall be conducted within the proposed impact area seventy-two(72) hours prior to the commencement of grading and/or construction. This survey is necessary to assure avoidance of impacts to nesting raptors (i.e., American kestrel and red-tailed hawk)and/or birds protected by the Federal Migratory Bird Treaty Act. If any active nests are detected, the area will be flagged and mapped on the construction plans along with a minimum 25-foot buffer and up to a maximum three hundred feet (300') for raptors, as determined by the project biologist, and will be avoided until the nesting cycle is complete. P.C. Resolution No. 2006-60 Page 10 of 11 22. Aside from site improvements explicitly approved by these conditions of approval, any future request for additions, accessory structures or additional grading that increase the lot coverage for the site shall require the approval of a further revision to Conditional Use Permit No. 23 by the Planning Commission, and shall be subject to new and separate environmental review. Grading Approval Conditions: 23. The permitted grading quantities shall be as follows: Area Cut Fill Total Earth Net Earth Movement Movement House 531 CY 47 CY 578 CY <484 CY> Footprint Outside 96 CY 179 CY 275 CY 83 CY Footprint Total 627 CY 226 CY 853 CY <401 CY> The maximum depth of cut shall be 11 feet and the maximum depth of fill shall be 3 feet. ROUGH AND FINAL GRADE CERTIFICATION REQUIRED,. 24. The applicant shall furnish the City with copies of landfill receipts for the approved export of 401 cubic yards of material prior to Building Permit final. 25. Haul routes used to transport soil exported from the project site shall be approved by the Director of Public Works. 26. The maximum height of the upslope retaining wall in the rear yard shall not exceed 5 feet in height. The maximum heights of the two (2) upslope retaining walls adjacent to the driveway shall be 3 feet and 6 feet, with a minimum horizontal separation of 3 feet that will be landscaped with shrubs and/or vines. 27. Maximum new slopes shall not exceed 67% adjacent to the driveway and 35% elsewhere on the property (33% proposed). 28. Prior to the issuance of a grading permit by the City's Building Official,the applicant shall obtain final approval of the grading plan from the City's geotechnical consultant. The applicant shall be responsible for the preparation and submittal all soil engineering and/or geology reports required by the City's geotechnical consultant in order to grant such final approval. 29. Maximum driveway slopes shall not exceed 20 percent (18% proposed). M:\Projects\ZON2005-00660(Jindal,3231 Palos Verdes Dr S)\20061128—Reso—PC.doc P.C. Resolution No. 2006-60 Page 11 of 11