AMG and Associates Inc (Change Order 39)City of Rancho Palos Verdes Department of Public Works 30940 Hawthorne Blvd, Rancho Palos Verdes, CA 90275 (310)544-5252 www.publicworks@rpvca.gov CHANGE ORDER MEMORANDUM TO: RAMZI AWWAD, DIRECTOR OF PUBLIC WORKS FROM: ERIN JONES, GRIFFIN STRUCTURES DATE: JULY 25, 2023 SUBJECT: LADERA LINDA COMMUNITY PARK CONSTRUCTION CHANGE ORDER NUMBER: 39 Description of Construction Change Order Per ASI 23, this change order is for the cost to replace CAT6 cabling to site Wireless Access Points (WAPs) with fiber as is required due to overall distances from the building MDF room to the site WAPs. This change order also includes 1 added bollard housing for the WAP located on the lower tier, and NEMA enclosures for the WAPs located on the upper tier. The WAP bollard housing and NEMA enclosures were excluded originally as Owner Furnished and accordingly labeled on the drawings as “not used”. Also included in this change order are credits associated with reduced conduit (2 WAPs deleted from scope) and reduced trenching (fewer WAPS, as well as conduit for WAPs now running in same trench as security camera conduit rather than in separate trenches, as WAPs were re- located in ASI 23 onto security poles.) Justification The construction Technology drawings called for CAT6 cabling to the site WAP locations on the low tier and upper tier, but this was changed to fiber by the design team to accommodate the distance. The technology design consultant, Vantage Consulting, stated that based on the distances to the WAPs, CAT6 would not be effective and should not have been specified. Fiber extenders were also added, as the original design called for category cabling (CAT6) to feed out to the units but the distance turned into an issue. The construction Technology drawings intended for the WAP on the low tier to be mounted to a pole per the Security drawings, but the Security drawings did not show any note or detail for a pole. The ASI provides specs and details for a bollard housing for this WAP. During development of the ASI, Vantage reviewed the WAP coverage and concluded that 3 WAPs would cover the areas of active play and benches in the upper tier and therefore 2 WAPs were deleted from the upper tier. DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA City of Rancho Palos Verdes Department of Public Works 30940 Hawthorne Blvd, Rancho Palos Verdes, CA 90275 (310)544-5252 www.publicworks@rpvca.gov Cost Analysis Scope and pricing were reviewed by Johnson Favaro, Vantage Consulting, and Griffin Structures and the contractor addressed their comments. See attached email from Vantage Consulting and pricing analysis of major components. Schedule Analysis No time extension was requested by the contractor, and work is expected to be completed within the original construction timeframe. Attachments: Construction Contract Change Order Form Construction Contract Change Order Summary Sheet Contractor’s Change Order Proposal DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA City of Rancho Palos Verdes Department of Public Works 30940 Hawthorne Blvd, Rancho Palos Verdes, CA 90275 (310)544-5252 www.publicworks@rpvca.gov 8405 13 0 0 11 0 0 0 0 0 0 0CO#10 $42,918.80 Working Days 11/09/22 CO#8 $6,437.02 Working Days 09/27/22 CO#9 $1,818.52 Working Days 11/09/22 CO#6 $824.34 Working Days 09/01/22 CO#7 $10,202.36 Working Days 09/27/22 CO#4 $8,558.42 Working Days 09/01/22 CO#5 -$5,378.25 Working Days 09/01/22 CO#2 $12,628.58 Working Days 08/09/22 CO#3 $53,526.25 Working Days 08/31/22 CHANGE ORDER NUMBER COST AMOUNT SCHEDULE EXTENSION DATE CO#1 $54,534.52 Working Days 05/27/22 ORIGINAL COMPLETION DATE:07/27/23 TOTAL SCHEDULE CHANGE ORDERS:Working Days NEW CONTRACT COMPLETION DATE:08/15/23 $1,029,075.00 TOTAL CHANGE ORDERS COST:$784,291.44 NEW CONTRACT AMOUNT:$14,505,291.44 REMAINING CONTINGENCY AMOUNT:$244,783.56 PURCHASE ORDER NUMBER:20220215 ACCOUNT NUMBER:330-400-8405-8403 ORIGINAL CONTRACT AMOUNT:$13,721,000.00 ORIGINAL CONTINGENCY AMOUNT: PREPARED BY:JAMES O'NEILL CONTRACTOR NAME:AMG & Associates, Inc. CONTRACT NUMBER:FY2022-050 CONSTRUCTION CHANGE ORDER SUMMARY SHEET PROJECT NAME:Ladera Linda Community Park DATE:07/25/23 PROJECT CODE: 1 of 2 DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA 8/16/2023 City of Rancho Palos Verdes Department of Public Works 30940 Hawthorne Blvd, Rancho Palos Verdes, CA 90275 (310)544-5252 www.publicworks@rpvca.gov 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 0 0 0 0CO #39 $24,530.09 Working Days 07/25/23 CO # 37 $3,561.51 Working Days 06/16/23 CO #38 $23,527.90 Working Days 07/12/23 CO #35 $3,765.15 Working Days 06/08/23 CO #36 $697.56 Working Days 06/16/23 CO #33 $10,095.54 Working Days 05/31/23 CO #34 $179,119.98 Working Days 06/08/23 CO#31 $2,104.03 Working Days 05/18/23 CO#32 $2,291.43 Working Days 05/19/23 CO#29 $1,055.31 Working Days 05/09/23 CO#30 $3,682.06 Working Days 05/18/23 CO#27 $136,226.21 Working Days 05/03/23 CO#28 $10,819.96 Working Days 05/05/23 CO#25 $8,909.82 Working Days 04/06/23 CO#26 $21,061.12 Working Days 04/25/23 CO#23 $4,094.67 Working Days 02/23/23 CO#24 $19,573.51 Working Days 03/07/23 CO#21 $10,075.07 Working Days 02/21/23 CO#22 $3,178.42 Working Days 02/22/23 CO#19 $17,562.82 Working Days 02/09/23 CO#20 $3,679.17 Working Days 02/16/23 CO#17 $12,582.87 Working Days 02/03/23 CO#18 $16,546.62 Working Days 02/09/23 CO#15 -$3,117.01 Working Days 01/17/23 CO#16 $59,788.90 Working Days 02/02/23 CO#13 $0.00 Working Days 12/30/22 CO#14 -$20,112.42 Working Days 12/30/22 CO#11 $33,868.27 Working Days 12/01/22 CO#12 $9,052.32 Working Days 12/01/22 CHANGE ORDER NUMBER COST AMOUNT SCHEDULE EXTENSION DATE 2 of 2 DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA 1 Erin Jones From:Ingrid Dennert <idennert@johnsonfavaro.com> Sent:Friday, August 4, 2023 6:12 PM To:Erin Jones Subject:FW: Ladera Linda - Change Order 39 - ASI 23 - Revised Site WAP Cabling and Add Bollard Housing Attachments:23-0804 VANTAGE COMMENTS - 8405 Ladera Linda CCO 39_DRAFT.pdf Hi Erin, See below and attached from Vantage. Best, Ingrid INGRID DENNERT ASSOCIATE PRINCIPAL, ARCHITECT 5898 BLACKWELDER STREET CULVER CITY, CA 90232 T: 310.559.5720 | F: 310.559.8220 http://www.johnsonfavaro.com idennert@johnsonfavaro.com From: Abigail Day <abigail.day@vantagetcg.com> Sent: Friday, August 4, 2023 12:06 PM To: Ingrid Dennert <idennert@johnsonfavaro.com> Cc: Michael Dannenberg <Michael.Dannenberg@vantagetcg.com> Subject: RE: Ladera Linda - Change Order 39 - ASI 23 - Revised Site WAP Cabling and Add Bollard Housing Good Afternoon Ingrid, Apologies that our review of CCO 39 back in May wasn’t sufficient. Please see below and attached for more details. Hopefully this provides the City with what it needs. Vantage has reviewed the CO associated with ASI 23 in response to issued clarifications from RFIs 133 and 148 and after review comments by both Vantage and Griffin and the contractor’s revised CO #042, Vantage feels confident that the pricing submitted is acceptable and is covering the additions and deductions for the revised scope. See attached for additional comments. Thank you, Abigail __________________________________________ Abigail Day, PE she/her/hers VANTAGE CONSULTING REVIEW OF WAP CHANGE ORDER PRICING DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA 2 Design & Engineering Business Unit Leader Vantage Technology Consulting Group T 978-610-3853 C 617-655-3606 __________________________________________ Note: If this email arrives outside of your working hours, please do not feel obligated to respond until you are back at work. From: Ingrid Dennert <idennert@johnsonfavaro.com> Sent: Thursday, August 3, 2023 9:07 PM To: Michael Dannenberg <Michael.Dannenberg@vantagetcg.com>; Abigail Day <abigail.day@vantagetcg.com> Subject: FW: Ladera Linda - Change Order 39 - ASI 23 - Revised Site WAP Cabling and Add Bollard Housing Michael, Abigail, The CM is working quickly to get City approval on the change order relating to the change of mounting WAPs to the security camera poles and substituting fiber for CAT6, as WAPs need to be installed now, but the city would like a final assurance in writing from you that you have reviewed pricing in the attached of the various components and that based on your expertise/experience, the material pricing for these components is reasonable. Can you please respond to me by tomorrow stating that you have reviewed the costs and they are reasonable/in line with typical current costs for such equipment and materials? Thanks, Ingrid INGRID DENNERT ASSOCIATE PRINCIPAL, ARCHITECT 5898 BLACKWELDER STREET CULVER CITY, CA 90232 T: 310.559.5720 | F: 310.559.8220 http://www.johnsonfavaro.com idennert@johnsonfavaro.com From: Erin Jones <ejones@griffinstructures.com> Sent: Thursday, August 3, 2023 2:32 PM To: Ingrid Dennert <idennert@johnsonfavaro.com> Subject: FW: Ladera Linda - Change Order 39 - ASI 23 - Revised Site WAP Cabling and Add Bollard Housing Hi Ingrid, Please see below comment from Lincoln. Can you please ask Vantage for a more specific response on the pricing? Thank you. DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA GRIFFIN STRUCTURES PRICING ANALYSIS - ESTIMATED COST OF WORK (MAJOR COMPONENTS) ASI 23 - Wireless Access Point Mounting DESCRIPTION SUBMITTED PCO 33R3 ESTIMATE COMPARISON Material, Installation and Subcontractor Markup Qty Unit Rate Cost Rate Cost Note on estimate pricing Total Deleted Electrical Conduit & Trenching -99 LF 54.84 (5,429.00) 28.00 (2,772.00) RS Means 260533139140, RS Means 31231630050 Total Deleted CAT 6A Cabling -3000 LF 1.45 (4,341.00) 1.87 (5,610.00) RS Means 271513137244 Total Added Fiber 1500 LF 3.06 4,585.00 2.82 4,225.35 RS Means 271323130105 Total Added Bollard Housing 1 Ea 1,511.93 1,511.93 1,533.38 1,533.38 Retail, plus tax, markup & installation: https://www.chatsworth.com/en-us/wireless- enclosures/products/wireless-enclosures/netpoint/3032/3032 Total Added Nema Enclosure 4 Ea 840.11 3,360.44 565.65 2,262.60 Retail, plus tax, markup & installation & equipment: https://www.chatsworth.com/en- us/products/wireless-enclosures/skybar/1026/1026-12106-c Total Added Rack Mount Cage 1 Ea 1,099.31 1,099.31 1,090.63 1,090.63 Retail, plus tax, markup & installation: https://www.123securityproducts.com/c1us.html DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA City of Rancho Palos Verdes Department of Public Works 30940 Hawthorne Blvd, Rancho Palos Verdes, CA 90275 (310)544-5252 www.publicworks@rpvca.gov 8405 39 0.0 LS 1.0 LS 1.0 LS 0.0 LS -1.0 LS -1.0 LS 0.0 LS -1.0 LS -1.0 LS 0.0 LS 1.0 LS 1.0 LS 0.0 LS 1.0 LS 1.0 LS 0.0 LS 1.0 LS 1.0 LS 0 13 0 $4,341.71 -$4,341.71 0 3 271500 AMG PCO 42R2 - ASI 23 - WAP Mounting- Credit for reduced UG Conduit $5,429.36 -$5,429.36 0 2 271500 AMG PCO 42R2 - ASI 23 - WAP Mounting- Credit CAT 6 NEW CONTRACT AMOUNT:$14,505,291.44 NEW COMPLETION DATE:08/15/23 TOTAL OF CHANGE ORDER #1-38:$759,761.35 TOTAL OF TIME EXTENSIONS #1-38:Working Days TOTAL OF CHANGE ORDER #39:$24,530.09 TOTAL OF TIME EXTENSIONS #39:Working Days Totals $24,530.09 0 A TIME EXTENSION OF WORKING DAYS WILL BE ALLOWED FOR THIS WORK ORIGINAL CONTRACT AMOUNT:$13,721,000.00 ORIGINAL COMPLETION DATE:07/27/23 6 012600 AMG Bonding $296.63 $296.63 0 5 012600 AMG Insurance $410.09 $410.09 0 4 012600 AMG Overhead $1,913.73 $1,913.73 0 ADDITIONAL WORKING DAYS 1 271500 AMG PCO 42R2 - ASI 23 - WAP Mounting- Add fiber, bollard, NEMA enclosures $31,680.71 $31,680.71 0 This change order is for the cost to replace CAT6 cabling to site WAPs with fiber, add a bollard housing for the low tier site WAP, and NEMA enclosures at high tier WAPs, Per ASI 23. SUMMARY OF QUANTITY CHANGES ITEM NO. SPEC CODE DESCRIPTION ORIGINAL QUANTITY NEW QUANTITY QUANTITY DIFFERENCE UNIT PRICE PRICE DIFFERENCE CHANGE ORDER NUMBER:DATE:07/25/23 CONTRACTOR NAME:AMG & Associates, Inc. DESCRIPTION AND LOCATION OF PROPOSED WORK CONSTRUCTION CHANGE ORDER FORM CONTRACT NUMBER:FY2022-050 PROJECT NAME:Ladera Linda Community Park PURCHASE ORDER NUMBER:20220215 PROJECT CODE: DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA City of Rancho Palos Verdes Department of Public Works 30940 Hawthorne Blvd, Rancho Palos Verdes, CA 90275 (310)544-5252 www.publicworks@rpvca.gov 39 Recommended: Erin Jones Date: Construction Manager, Griffin Structures Signature Contractor: City:Date: Signature Date: Public Works Director Signature Ara Mihranian Date: City Manager Signature Lincoln Lo Contract Officer Ramzi Awwad By signing this Change Order, Contractor understands and agrees that it is accepting the specified sums and adjustment of contract time of completion (if any) set forth herein as full, final and complete satisfaction of any and all claims by Contractor for all costs and expenses of Contractor and anyone for whom Contractor may be responsible for the work referred to herein, including but not limited to costs or expenses of the Contractor or any of its subcontractors, materials suppliers, vendors or anyone else for whom Contractor is responsible, for labor, materials, services or equipment, no matter how characterized, whether known or unknown to Contractor, including but not limited to, all field and home office overhead, delay costs/claims, acceleration costs/claims, unabsorbed or under-absorbed home office overhead, extended field costs, general conditions, claim preparation costs, inefficiencies, or the like, no matter how characterized. Contractor further understands and agrees by signing this Change Order that any attempt by Contractor to purportedly reserve rights to claim additional time or compensation for the work referred to herein, is void. Except as set forth, all terms and provisions of the contract and all prior change orders remain in full force and effect. Execution of this Change Order by both parties constitutes a binding agreement. This document constitutes the entire agreement between the parties. The person signing this Change Order for Contractor hereby represents and warrants that he/she is fully authorized to sign this Agreement on behalf of Contractor. Anthony R. Traverso Vice President/Secretary/Treasurer Accepted and Executed by: PURCHASE ORDER NUMBER:20220215 CHANGE ORDER NUMBER:PROJECT CODE:8405 CONTRACTOR NAME:AMG & Associates, Inc. CONSTRUCTION CHANGE ORDER FORM CONTRACT NUMBER:FY2022-050 PROJECT NAME:Ladera Linda Community Park 7/25/23 Date: Signature Anthony R. Traverso Digitally signed by Anthony R. Traverso Date: 2023.07.26 07:55:47 -07'00' 8/7/23 DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA 8/15/2023 8/16/2023 Bulletin ASI 023 This Bulletin is issued to define Scope of Revisions/ clarifications to the Drawings and/or Specifications. The Contractor shall carry out the Work in accordance with the following supplemental instructions without change in Contract Sum or Contract Time. Proceeding with the Work in accordance with these instructions indicates your acknowledgment that there will be no change in the Contract Sum or Contract Time. Brief Description of Revisions/ Clarifications: WAPs are noted on the technology drawings to be pole mounted. Locations of wireless access points (WAP) at the playground area are revised to match to security pole locations with orientation indicated. Provide credit for reduction of (2) WAP positions. Details provided for WAP mounting to security poles. At lower tier lawn, a WAP was noted to be pole mounted, however it is to be housed in bollard. Details for bollard model WAP and Footing Kit model number provided. WAP detail at gypsum board ceiling moved on the sheet, no changes made. Attachments: T1.01 – TECHNOLOGY SITE PLAN T6.01 – TECHNOLOGY DETAILS T6.02 – TECHNOLOGY DETAILS T6.03 – TECHNOLOGY DETAILS Project LADERA LINDA COMMUNITY CENTER Contract No. 1803 To AMG & ASSOCIATES Office No. No. of Pages 4 Subject Wireless Access Point Mounting Sender Kimberly Castillo, Johnson Favaro Date 10/17/22 DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA ICVICVICVICVICVEPBCATVTEL498.00146PL COR492.00147PL CO R465.00148N COR LO T 5465.00149NW CO R LO T 5456.00150BC FO RRESTAL442.00152PO B PCL 2460.00155PL CO R @ RWICVICVICVICVICVEPBCATVTEL498.00146PL COR492.00147PL CO R465.00148N COR LO T 5465.00149NW CO R LO T 5456.00150BC FO RRESTAL442.00152PO B PCL 2460.00155PL CO R @ RWICVICVICVICVICVEPBCATVTEL498.00146PL COR492.00147PL CO R465.00148N COR LO T 5465.00149NW CO R LO T 5456.00150BC FO RRESTAL442.00152PO B PCL 2460.00155PL CO R @ RWMDF 135 8 7 9 6 8 7 10 2 4 8 7 BIM LADERA LINDA COMMUNITY PARK PROJECT: CITY OF RANCHO PALOS VERDES: A r c h i t e c t u r e a n d U r b a n D e s i g n 5898 Blackwelder Street, Ground Floor Culver City, CA 90232 (Tel) 310-559-5720 (Fax) 310-559-8220 ARCHITECT CONSULTANTS . ARCHITECT'S / ENGINEER'S STAMP The drawings and specifications, ideas, designs, and arrangements are and shall remain the property of the architect. No part thereof shall be copied or used in connection with any work or project other than the specific project for which they have been prepared without the written consent of the architect. Visual contact with these drawings or specifications shall constitute evidence of acceptance of these restrictions. Written dimensions on these drawings shall have precedence over scaled dimensions. Contractor shall verify and be responsible for all dimensions and conditions on the job and this office must be notified of any variation from the dimensions and conditions shown by these drawings. Shop details must be submitted to this office for approval before proceeding with fabrication. © MDA Johnson Favaro 2017 CHECKED BY: No.Issue DRAWN BY: Date TITLE: SHEET: PROJECT #: SCALE: DATE: CITY APPROVALS PROJECT 32201 Forrestal Drive Rancho Palos Verdes, CA 90275 30940 Hawthorne Blvd. Rancho Palos Verdes, CA 90275 11/29/21 6/14/2022 9:51:58 AMT1.01 TECHNOLOGY SITE PLAN MDVANTAGE REF. SCALE:T1.01 3/64" = 1'-0" TECHNOLOGY SITE PLAN 1 NORTH 1 (1) - 2" PVC CONDUIT AND OSP CABLING TO DEVICE. COORDINATE WITH LIGHTING FOR POLE MOUNTED EQUIPMENT. REFERENCE NOTES: 2 (2) - 4" CONDUITS TO EACH SERVICE PROVIDER VAULT. 3 NOT USED. 4 (4) - 4" CONDUITS FOR SERVICE PROVIDERS. 5 NOT USED. 6 NEW 3' X 4' X 3' DP PRECAST MAINTENANCE HOLE WITH TRAFFIC-RATED LID. 7 NEW PULLBOX (COORDINATE WITH LANDSCAPING). 8 (1) - 3" PVC CONDUIT AND OSP CABLING PASSING THROUGH PULLBOX TO DEVICE. COORDINATE WITH LANDSCAPING FOR POSITIONING. 9 NEW TELECOM VAULT FOR FRONTIER CONNECTION POINT. 10 NEW TELECOM VAULT FOR CHARTER / SPECTRUM CONNECTION POINT. UNDERGROUND INFRASTRUCTURE SHOWN ARE DIAGRAMATIC ONLY. FINAL LOCATIONS SHALL BE VERIFIED AND COORDINATED WITH CIVIL PLANS. GENERAL NOTES: 1. ISSUES/REVISIONS 1 PERMIT SET 11/29/21 3 1 1 1 3 CONTRACTOR TO PROVIDE HYBRID 2-STRAND SM FIBER AND POWER MOUNT WAP PER DETAILS 1/T6.01, 2/T6.01 & 7/T6.03. TO SUPPORT WAP BACK TO IDF. 3 11 11 5 2 ASI 23A 10/14/22 MOUNT WAP ON CUSTOM POLE PER DETAILS 8/T6.03 & 9/T6.03 AND 9/ES4.01 FOR CUSTOM MANUFACTURERED ADAPTER PLATE.!11 MOUNT WAP WITHIN 48" TALL BOLLARD PER DETAILS 7/T6.02.!12 1 12 3 23A 23A 23A 23A 23A DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA VIDEO PROJECTOR PROVIDED & INSTALLED BY AVC. REFER TO AV SPECIFICATIONS FOR SIZE AND WEIGHT. FINISHED T-BAR CEILING. REFER TO ARCHITECTURAL DRAWING. STRUCTURAL DECK & SLAB PLAN ELEVATION 1 1 PROVIDED BY G.C. PROVIDED BY AVC DUPLEX POWER RECEPTACLE IN CEILING TILE BEHIND FLAT PANEL. RECEPTACLE PROVIDED AND INSTALLED BY EC. PROVIDE 24"x24" CLEAR AREA TO DECK ABOVE VIDEO PROJECTOR LOCATION TO ACCOMMODATION VIDEO PROJECTOR DISPLAY STRUCTURAL SUPPORT. 12 GA. WIRE BRACING IN 4 DIRECTIONS (TYP) PROVIDE (2) 24" LONG PARALLEL UNISTRUT CHANNELS SECURED TO STRUCTURE ABOVE USING ALL-THREAD HANGARS PROVIDE (2) 24" LONG PARALLEL UNISTRUT-P1000 CHANNELS SECURED TO UPPER UNISTRUT CHANNELS. ALLOW VARIABLE POSITIONING. 1 1/2" DIA.(NPT) PIPE PROVIDED & INSTALLED BY AVC. PROJECTOR MOUNTING PLATE PROVIDED & INSTALLED BY AVC. PROVIDE LATERAL BRACING. NOTES C.L. PROJECTION SCREEN( 24" )( 24" ) MOUNTING TO BUILDING SUPERSTRUCTURE: SUBMIT SPECIFIC MOUNTING HARDWARE AND METHODS TO PROJECT STRUCTURAL ENGINEER FOR APPROVAL 1. DESIGNS & ARRANGEMENT ILLUSTRATED ARE FOR REFERENCE ONLY. ALL STRUCTURAL SUPPORTS TO BE ENGINEERED BY A LICENSED STRUCTURAL ENGINEER. 2. ROJECTOR STRUCTURAL SUPPORT TO BE RIGID AND FREE FROM ANY PERCEPTIBLE VIBRATION IN STRUCTURE TO PREVENT MOVEMENT OF PROJECTED IMAGE. 3. REFER TO AV EQUIPMENT PLAN(S) FOR POSITION OF STRUCTURAL SUPPORT ABOVE CEILING, FOR EACH PROJECTOR LOCATION. 3/8" ALL-THREAD HANGER 120 VACTO WALL SWITCH (SUPPLIED AND INSTALLED WITH SCREEN) TO A/V CONTROL SYSTEM (IF APPLICABLE) FLEX CONDUIT FLEX CONDUIT LOW VOLTAGE CONTROLLER BUILT INTO LEFT SIDE OF SCREEN CASE (CONFIRM IN FIELD) 1. ALL CABLING TO BE IN CONDUIT U.O.N. 2. ALL WIRING PER MANUFACTURER'S INSTRUCTIONS. NOTES PROJECTION SCREEN J J (VERIFY) REFER TO AV PLANS FINISH TRIM, VERIFY ACTUAL INSTALLATION FINISH DETAILS WITH ARCHITECT PROJ. SCREEN HOUSING CONFIRM MATERIAL & FIRE RATING WITH MFR PRIOR TO INSTALLATION HINGED DOOR FOR SERVICE ACCESS TO SCREEN & MOTOR ASSEMBLY ACCESS REQ'D FOR FULL LENGTH OF SCREEN PROJECTION SCREEN DROPS THROUGH "TRAP DOOR" INTO OPERATING POSITION VERIFY THAT PATH OF TRAVEL IS CLEAR OF OBSTRUCTIONS. PROJECTION SCREEN ROLLER. MOTOR LOCATED IN ROLLER ( MAXIMUM WEIGHT: 92 LBS ) FINISHED CEILING (REFER TO ARCHITECTURAL DRAWINGS) PROJECTORFACE OF SCREEN 1. LOW VOLTAGE CONTROL INTERFACE TO BE PROVIDED WHERE MULTIPLE CONTROL LOCATION OCCUR AND/OR WHERE SCREEN IS TO BE CONTROLLED VIA THE AV CONTROL SYSTEM. 2. PROJECTOR SCREENS PROVIDED AND INSTALLED BY GENERAL CONTRACTOR. NOTES ABOVE VIEWSIDE VIEW 3/8" ALL-THREAD HANGER. TYP. (4) PLACES. 12 GA. WIRE BRACING IN 4 DIRECTIONS (TYP.) 1 1 STRUCTURAL SLAB 4" DEEPCONDUIT(X")x(X")x(X") PULLBOX WITH FLANGE NOTES: 1. OVERSIZED FRONT COVER SHOULD BE PAINT GRADE AND PAINTED TO MATCH INTERIOR COLOR SCHEME. 2. ALL CONDUIT FOR AV RUN PER AV INFRASTRUCTURE PLAN 3. AV CONDUITS SHOWN ARE REPRESENTATIVE. SEE AV DRAWINGS FOR EXACT REQUIREMENTS. 4. REFER TO AV ENLARGED PLANS FOR ACTUAL DIMENSIONS. OVERSIZED FRONT COVER CONDUITCONDUITCONDUITCONDUITCONDUITCONDUITCONDUITCONDUITARCH WALL ( WALL CONSTRUCTION PER ARCH WALL TYPES). PERFORATED PRESS-IN GRILLE FINISH CEILING MATERIAL (REFER TO ARCHITECT'S DRAWINGS) TRANSFORMER AS REQ'D SECONDARY SUPPORT POINT SUPPORT LOUDSPEAKER ASSEMBLY FROM RIGID STRUCTURE, DO NOT SUPPORT IN CEILING STEEL BACKCANNOTES: J-HOOK (TYP.) PLENUM CABLE (TYP.) 1. CEILING LOUDSPEAKER ASSEMBLY (ENCLOSURE, LOUDSPEAKER, AND GRILLE) TO BE PROVIDED AND \ INSTALLED BY G.C. 2. CABLING AND TERMINATION AT LOUDSPEAKER TO BE PROVIDED AND INSTALLED BY AVC 3. GRILLE FINISH REQUIREMENTS AS SPECIFIED BY ARCHITECT 4. APPROX. WEIGHT OF SPEAKER: LESS THAN 20 LBS. 1 1 1 1 PERFORATED PRESS-IN GRILLE FINISH CEILING MATERIAL (REFER TO ARCHITECT'S DRAWINGS) TRANSFORMER AS REQ'D RIGID/EMT CONDUIT OR PLENUM CABLE. REFER TO ROOM PLAN.SECONDARY SUPPORT POINT SUPPORT LOUDSPEAKER ASSEMBLY FROM RIGID STRUCTURE, DO NOT SUPPORT IN CEILING STEEL BACKCAN NOTES: 1 1 1. CEILING LOUDSPEAKER ASSEMBLY (ENCLOSURE, LOUDSPEAKER, AND GRILLE) TO BE PROVIDED AND \ INSTALLED BY G.C. 2. CABLING AND TERMINATION AT LOUDSPEAKER TO BE PROVIDED AND INSTALLED BY AVC 3. GRILLE FINISH REQUIREMENTS AS SPECIFIED BY ARCHITECT 1 1 BIM LADERA LINDA COMMUNITY PARK PROJECT: CITY OF RANCHO PALOS VERDES: A r c h i t e c t u r e a n d U r b a n D e s i g n 5898 Blackwelder Street, Ground Floor Culver City, CA 90232 (Tel) 310-559-5720 (Fax) 310-559-8220 ARCHITECT CONSULTANTS . ARCHITECT'S / ENGINEER'S STAMP The drawings and specifications, ideas, designs, and arrangements are and shall remain the property of the architect. No part thereof shall be copied or used in connection with any work or project other than the specific project for which they have been prepared without the written consent of the architect. Visual contact with these drawings or specifications shall constitute evidence of acceptance of these restrictions. Written dimensions on these drawings shall have precedence over scaled dimensions. Contractor shall verify and be responsible for all dimensions and conditions on the job and this office must be notified of any variation from the dimensions and conditions shown by these drawings. Shop details must be submitted to this office for approval before proceeding with fabrication. © MDA Johnson Favaro 2017 CHECKED BY: No.Issue DRAWN BY: Date TITLE: SHEET: PROJECT #: SCALE: DATE: CITY APPROVALS PROJECT 32201 Forrestal Drive Rancho Palos Verdes, CA 90275 30940 Hawthorne Blvd. Rancho Palos Verdes, CA 90275 11/29/21 6/14/2022 9:52:14 AMT6.01 TECHNOLOGY DETAILS MDVANTAGE REF. SCALE:T6.01 NOT TO SCALE CEILING MOUNTED PROJECTOR 3 REF. SCALE:T6.01 NOT TO SCALE CEILING RECESSED ELECTRIC SCREEN CONNECTION DETAIL 4 REF. SCALE:T6.01 NOT TO SCALE TYPICAL CEILING RECESSED PROJECTION SCREEN 5 REF. SCALE:T6.01 NOT TO SCALE TYPICAL AV PULL BOX 6 REF. SCALE:T6.01 NOT TO SCALE TYPICAL CEILING RECESSED LOUDSPEAKER-ACCESSIBLE 7 REF. SCALE:T6.01 NOT TO SCALE TYPICAL CEILING RECESSED LOUDSPEAKER-HARDLID 8 ISSUES/REVISIONS 1 PERMIT SET 11/29/21 DETAIL - LIGHTPOLE BASE REF. SCALE:T6.03 NOT TO SCALE 62DETAIL - BEGA LIGHTPOLE HOLE PATTERN REF. SCALE:T6.03 NOT TO SCALE 61 NOTES: 1. COMMUNICATIONS PVC CONDUIT PER SITE PLAN. 2. REFER TO DETAILS 1/T6.01 AND 7/T6.03 FOR HYBRID INDOOR/OUTDOOR CABLING. 10" MAX. CL 14 FT. AFF 1-3/8" DIAMETER FOR 1" FLEX SEALTITE CONDUIT 2" DIAMETER FLAT SURFACE FOR CONDUIT INTERFACE DETAIL VIEW "A" 10" MAX. CL 14 FT. AFF LIGHT STANDARD POWER COMMUNICATION/DATA 1" CONDUIT FOR COMMUNICATION WITHIN POLE. REFER TO DETAIL 2/T6.01. 13 FT. AFF T6.01 T6.01 2 ASI 23A 10/14/22 23A DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA 1-1/4" CONDUITREFER TO ELECTRICA L FOR SIZING REFER TO FLOOR PLANS FOR SIZING POWER REFER TO FLOOR PLANS FOR SIZING DETAIL A DETAIL B SECTION ( 11" )(5-1/4")( 3-5/8 " )( 9" )MANUFACTURER: FSR INC. 244, BERGEN BLVD. WEST PATERSON, NJ 07424 PH:973.785.4347 FAX: 973.785.4207 WWW.FSRINC.COM MODEL :PWB-100 AVDATAPOWER DUPLEX OUTLET DUPLEX OUTLET DATA AV REFER TO ELECTRICA L FOR SIZING ELEVATION WALL FINISH (REFER TO ARCHITECTURAL DWGS AND SCHEDULES) FACEPLATE MIN. 20" INTERIOR CLEARANCE 1"12" 6"2"MIN. 24-1/4" INTERIOR CLEARANCE 1'-6"MIN. 27" INTERIOR CLEARANCE0'-2"B ANOTE: 1. FOR NUMBER OF BAYS, REFER TO ARCHITECTURAL DRAWINGS. 2. PROVIDE MINIMUM 2" CLEARANCE BETWEEN MILLWORK AND WALL. 3.CONVECTION COOLING AT 350BTU/HR. IN DISCOVERY AND TYP. CLASSROOMS. FAN-ASSISTED CONVECTION COOLING AT 550 BTU/HR IN MULTI-PURPOSE ROOM RACK. FOR WALL TYPES. REFER TO ARCHITECTURAL DRAWINGS. AV JUNCTION BOX. REFER TO FLOOR PLANS. DATA OUTLET. REFER TO ELECTRICAL DRAWINGS. POWER OUTLET. REFER TO ELECTRICAL DRAWINGS. PROVIDE VENT GRILL AT TOE KICK (1" X 12"). SECURE RACK BASE TO MILLWORK BASE WITH 1/4" WOOD SCREWS. TYP. (4) PLACES. PROVIDE 3/4" PLYWOOD. PROVIDE 4" x 4" CUTOUT PROVIDE 10" X 3" CUTOUT SECTION A SECTION BPLANRACK EXTENSION PLAN ELEVATION - ONE BAY 50CFM PANCAKE FAN(S) A/R SECURE WITH EMBEDDED CONCRETE FASTENERS SLAB ON GRADE (12")(16")TRIANGULAR BRACKET J-BOLT (TYP) 12" LADDER RACK PLYWOOD WALL LAG BOLT W/ 3" MIN. EMBED.EQUIPMENT RACK SPRING NUT, THREADED ROD, FLAT WASHER, LOCK WASHER, AND NUT FOR OVERHEAD BRACING (TYP. FOR 2)CHANNEL RACK TO RUNWAY MOUNTING PLATE STRUT/CHANNEL 12" LADDER RACK LADDER RACK BRACING TO WALL LADDER RACK BRACING TO EQUIPMENT RACK 1. LOCATE CPI BRACKET EVERY 6' OR AS REQUIRED ON WALL. ATTACH TO STUD LOCATIONS. NOTE: EZ-PATH SERIES 44 OR EQUAL FIRE RATED PATHWAY. CAPACITY TO MATCH CABLE TRAY FILL CAPACITY. EZ-PATH OR EQUAL MULTI- GANG WALL BRACKET. WIREBASKET FIRE RATED WALL BIM LADERA LINDA COMMUNITY PARK PROJECT: CITY OF RANCHO PALOS VERDES: A r c h i t e c t u r e a n d U r b a n D e s i g n 5898 Blackwelder Street, Ground Floor Culver City, CA 90232 (Tel) 310-559-5720 (Fax) 310-559-8220 ARCHITECT CONSULTANTS . ARCHITECT'S / ENGINEER'S STAMP The drawings and specifications, ideas, designs, and arrangements are and shall remain the property of the architect. No part thereof shall be copied or used in connection with any work or project other than the specific project for which they have been prepared without the written consent of the architect. Visual contact with these drawings or specifications shall constitute evidence of acceptance of these restrictions. Written dimensions on these drawings shall have precedence over scaled dimensions. Contractor shall verify and be responsible for all dimensions and conditions on the job and this office must be notified of any variation from the dimensions and conditions shown by these drawings. Shop details must be submitted to this office for approval before proceeding with fabrication. © MDA Johnson Favaro 2017 CHECKED BY: No.Issue DRAWN BY: Date TITLE: SHEET: PROJECT #: SCALE: DATE: CITY APPROVALS PROJECT 32201 Forrestal Drive Rancho Palos Verdes, CA 90275 30940 Hawthorne Blvd. Rancho Palos Verdes, CA 90275 11/29/21 6/14/2022 9:52:15 AMT6.02 TECHNOLOGY DETAILS MDVANTAGE REF. SCALE:T6.02 NOT TO SCALE CONSOLIDATED AV, POWER & DATA WALLBOX 1 REF. SCALE:T6.02 NOT TO SCALE 12 RU EQUIPMENT RACK IN ROOM CREDENZA 2 REF. SCALE:T6.02 NOT TO SCALE TWO POST RACK MOUNTING DETAIL 3 REF. SCALE:T6.02 NOT TO SCALE LADDER RACK BRACING TO RACK AND EQUIPMENT RACK 5 REF. SCALE:T6.02 NOT TO SCALE VERTICAL LADDER RACK BRACING TO WALL 4 REF. SCALE:T6.02 NOT TO SCALE TYPICAL WIREBASKET PENETRATION THROUGH FIRE RATED WALL 6 ISSUES/REVISIONS 1 PERMIT SET 11/29/21 2 ASI 23A 10/14/22 U-BOLT (TYP) PLYWOOD WALL UNISTRUT STRUT/CHANNEL MOUNTED TO WALL USING LAG BOLT. 18" LADDER RACK REF. SCALE:T6.03 NOT TO SCALE DETAIL - BOLLARD WAP MOUNTING 7 OBERON 39-303X-FOOTING-KIT OBERON #39-1026-1084-WORKBOX FOR FIBER TO CAT6A ACTIVE CONVERTER UNIT MOUNT TO OBERON #39-303X-COAP6300-KIT OBERRON NETPOINT BOLLARD #3032-LH-GY-48 (GRAY) 3/4" FLEXIBLE CONDUITS 3/4" FLEXIBLE CONNECTORS (1) 2" COMPRESSION FOR RIGID TO 3/4" FLEXIBLE CONNECTOR 120VAC DATA/COMMUNICATION CONCRETE FOOTING PROVIDED BY OTHERS GRADE 48" OBERON #39-1026-1084-WORKBOX FOR WAP MOUNT TO OBERON #39-303X-COAP6300-KIT (1) 3/4" FLEXIBLE CONDUIT 11.5" DIA. 23A DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA TO ADDITIONAL IDF'S AS REQ'DTELECOMMUNICATIONS BONDING BACKBONE. SIZE PER ANSI J-STD-607A; #4 AWG MINIMUM. BOND TO EQUIPMENT RACKS, CABLE RUNWAY, CABLE TRAY, ETC. #6 AWG MINIMUM, TYPICAL OF ALL IDF'S AND BDF REFERENCE NOTES: 1 2 NOTE: GROUNDING AND BONDING SHALL BE IN ACCORDANCE WITH ANSI / EIA / TIA / - 607 AND NEC 250 REQUIREMENTS. 2 2 1 IDF ROOM SIZING OF TBB TBB LENGTH (FT) TBB SIZE (AWG) LESS THAN 13 6 14-20 4 21-26 3 27-33 2 34-41 1 42-52 1/0 53-66 2/0 GREATER THAN 66 3/0 3 .4 5 ".2 8 " D IA .4 .0 0 "1 0 .0 0 "1 .0 0 ”1 .1 2 5 "XX-XX XX-XX FINISHED CEILING TO FINISHED FLOOR18" AFF U.O.N.NOTES: 1 1/4" CONDUIT, DOUBLE GANG BACKBOX AND SINGLE GANG MUDRING INSIDE WALL CAVITY. FLOOR LINE 1. CABLE TRAY, CONDUIT, BACKBOXES & PULL STRING TO BE INSTALLED BY ELECTRICAL CONTRACTOR. ITEMS SHOWN FOR REFRENCE ONLY. COMMUNICATIONS CABLE CABLE SPPORT REQUIRED EVERY 48"-60" CABLE TRAY BIM LADERA LINDA COMMUNITY PARK PROJECT: CITY OF RANCHO PALOS VERDES: A r c h i t e c t u r e a n d U r b a n D e s i g n 5898 Blackwelder Street, Ground Floor Culver City, CA 90232 (Tel) 310-559-5720 (Fax) 310-559-8220 ARCHITECT CONSULTANTS . ARCHITECT'S / ENGINEER'S STAMP The drawings and specifications, ideas, designs, and arrangements are and shall remain the property of the architect. No part thereof shall be copied or used in connection with any work or project other than the specific project for which they have been prepared without the written consent of the architect. Visual contact with these drawings or specifications shall constitute evidence of acceptance of these restrictions. Written dimensions on these drawings shall have precedence over scaled dimensions. Contractor shall verify and be responsible for all dimensions and conditions on the job and this office must be notified of any variation from the dimensions and conditions shown by these drawings. Shop details must be submitted to this office for approval before proceeding with fabrication. © MDA Johnson Favaro 2017 CHECKED BY: No.Issue DRAWN BY: Date TITLE: SHEET: PROJECT #: SCALE: DATE: CITY APPROVALS PROJECT 32201 Forrestal Drive Rancho Palos Verdes, CA 90275 30940 Hawthorne Blvd. Rancho Palos Verdes, CA 90275 11/29/21 6/14/2022 9:52:16 AMT6.03 TECHNOLOGY DETAILS MDVANTAGE REF. SCALE:T6.03 NOT TO SCALE TECHNOLOGY -DIAGRAM -GROUNDING 1 REF. SCALE:T6.03 12" = 1'-0" TELECOM BONDING BACKBONE SIZING TABLE 2 REF. SCALE:T6.03 1" = 1'-0" TELECOM GROUNDING BUSBAR 3 REF. SCALE:T6.03 6" = 1'-0" CONNECTION LOW OUTLET TO HOOK -TRAY 5 ISSUES/REVISIONS 1 PERMIT SET 11/29/21 REF. SCALE:T6.03 NOT TO SCALE 67DETAIL - LIGHTPOLE MOUNTED WIRELESS ACCESS ENCLOSURE CL 14 FT. AFF (U.O.N.) 6" MAX. SEALTITE (OR EQUAL) WEATHERIZED FLEXIBLE CONDUIT AND CONDUIT CLAMP TO POLE WITH RUBBER SEALING GROMMET TO DATA PATHWAY WITHIN LIGHTPOLE. NOTES: 1. MAX WEIGHT OF ASSEMBLY (ENCLOSURE, CLAMPING AND ACTIVE ELECTRONIC EQUIPMENT) IS LESS THAN 30 LBS. 2. PAINT ASSEMBLY TO MATCH POLE PER ARCHITECTURAL FINISH. IF NONE SPECIFICED, COLOR SHALL BE GRAY U.O.N. IN FIELD. LIGHTPOLE (6" DIAMETER) POLE ADJUSIBLE CLAMP AND "FISHMOUTH" ADAPTER PLATE FOR FLAT MOUNTING FACE. HAMMOND MFG. #PMH15GY POLE-MOUNT-BRACKET AND CLAMP (5"-10" DIA.) OR EQUAL. PAINT CLAMP AND ASSEMBLY TO MATCH ARCHITECTURAL FINISH AND POLE. WEATHERIZED NEMA POLYCARBONATE WI-FI ENCLOSURE WITH HINGED OPAQUE DOOR (OBERON 1026-12106-00 OR EQUAL). EXTEND HYBRID (2/C 12AWG. POWER AND 2-STRAND SM FIBER) FROM CLOSEST IDF TO ENCLOSURE TO POWER ACTIVE CONVERTER FOR P.O.E. DATA. LEAVE 18" OF SLACK CABLE FOR SERVICING. CONNECT WAP WITH SHIELDED CAT6A PATCH CABLE. HYBRID INDOOR/OUTDOOR CABLE TO BE COMMSCOPE #PFC-S02L12 OR APPROVED EQUAL. PAINT CLAMP AND ASSEMBLY TO MATCH ARCHITECTURAL FINISH AND POLE. (2) 1/4" STAINLESS THROUGH-BOLT X 1.5" LONG TO P1000 STRUT MEMBER (2 PLCS) WITH COMPRESSION NUT. 13 FT. AFF (U.O.N.) 10" MAX. ASI 23A 10/14/22 X-XXX-X X-XXX-X LEGEND NOTES: 1. PROVIDE (2) COMMUNICATIONS CAT 6A RJ45 CONNECTORS AT EACH OUTLET. PROVIDE (2) CAT 6A DISTRIBUTION CABLES RUNNING FROM EACH OUTLET TO THE COMMUNICATIONS ROOM AS INDICATED ON THE DRAWINGS. 2. OUTLET TO BE MOUNTED AT 12" AFC U.O.N. FACEPLATE LABEL 1. PROVIDE (2) COMMUNICATIONS CAT 6A RJ45 CONNECTORS AT EACH OUTLET. PROVIDE (2) CAT 6A DISTRIBUTION CABLES RUNNING FROM EACH OUTLET TO THE COMMUNICATIONS ROOM AS INDICATED ON THE DRAWINGS. 2. OUTLET TO BE MOUNTED AT 12" AFC U.O.N. C1 C2 C1 B1 LEGEND NOTES: B2 C2 B1 B2 OUTLET FACEPLATE B - BLANK C - COMMUNICATIONS (COPPER) JACK B - BLANK C - COMMUNICATIONS (COPPER) JACK REF. SCALE:T6.03 1" = 1'-0" TYPICAL OUTLET FACEPLATE DETAILS 4 WIRELESS ACCESS POINT DETAIL NOTES: 1. CEILING (REFER TO ARCHITECTURAL DRAWINGS).2. BACKBOX3. (1) - 1-1/4" CONDUIT STUBBED UP TO ACCESSIBLE CEILING TO NEAREST CABLE TRAY. 4. 1 2 3 4 1 3 4 MOUNTING BRACKET.5. FACEPLATE6. 5 6 REF. SCALE:T6.03 NOT TO SCALE DETAIL -WIRELESS ACCESS POINT (WAP -GYPSUM BOARD CEILING)6 REF. SCALE:T6.03 NOT TO SCALE DETAIL - CUSTOM POLE MOUNTINGDETAIL - CUSTOM POLE WAP MOUNTING REF. SCALE:T6.03 NOT TO SCALE 89 9 T6.03 CUSTOM POLE MOUNTED DETAIL (1) 3/4" SEALTITE FLEXIBLE CONDUIT (1) 3/4" FLEXIBLE CONNECTOR (1) 3/4" RIGID CONNECTOR (1) 3/4" 90-DEGREE ONE-PIECE CONNECTOR (HALEX OR EQUAL) (1) 3/4" FLEXIBLE CONNECTOR ACCESS PANELS (REFER TO DETAIL 7/ES4.01) (1) 2" COMPRESSION FOR RIGID TO 3/4" FLEXIBLE CONNECTOR 16 FT. 3/4" FLEXIBLE CONNECTOR 3" MAX. 120VAC DATA/COMMUNICATION CONCRETE FOOTING PROVIDED BY OTHERS GRADE 9 ES4.01 FABRICATED ADAPTER PLATE WEATHERIZED NEMA POLYCARBONATE WI-FI ENCLOSURE WITH HINGED OPAQUE DOOR (OBERON 1026-12106-00 OR EQUAL). EXTEND HYBRID (2/C 12AWG. POWER AND 2-STRAND SM FIBER) FROM CLOSEST IDF TO ENCLOSURE TO POWER ACTIVE CONVERTER FOR P.O.E. DATA. LEAVE 18" OF SLACK CABLE FOR SERVICING. CONNECT WAP WITH SHIELDED CAT6A PATCH CABLE. HYBRID INDOOR/OUTDOOR CABLE TO BE COMMSCOPE #PFC-S02L12 OR APPROVED EQUAL. PAINT CLAMP AND ASSEMBLY TO MATCH ARCHITECTURAL FINISH AND POLE. 23A 23A 23A DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA AMG & Associates Inc. 26535 Summit Circle Santa Clarita, California 91350 Phone: (661) 251-7401 Project: 01-22-157 - Ladera Linda Community Center and Park 32201 Forrestal Dr. Rancho Palos Verdes, California 90275 Prime Contract Potential Change Order #042: CE #094 - Bulletin ASI 23 Wireless Access Point Mounting TO: City of Rancho Palos Verdes 30940 Hawthorne Blvd. Rancho Palos Verdes, California 90275 FROM: AMG & Associates, Inc. 26535 Summit Circle Santa Clarita, California 91350 PCO NUMBER/REVISION: 042 / 2  CONTRACT:City Project No. 8405 - Ladera Linda Community Park Project   REQUEST RECEIVED FROM: Damien Gutierrez (Digital Technologies, Inc.) CREATED BY: Christopher Tumasone (AMG & Associates, Inc.) STATUS: Pending - In Review CREATED DATE: 4/4/2023 REFERENCE: PRIME CONTRACT CHANGE ORDER:  None   FIELD CHANGE: No   LOCATION: ACCOUNTING METHOD: Amount Based   SCHEDULE IMPACT: PAID IN FULL: No   EXECUTED:No SIGNED CHANGE ORDER RECEIVED DATE:   TOTAL AMOUNT: $24,530.09 POTENTIAL CHANGE ORDER TITLE: CE #094 - Bulletin ASI 23 Wireless Access Point Mounting CHANGE REASON: Client Request POTENTIAL CHANGE ORDER DESCRIPTION: (The Contract Is Changed As Follows) CE #094 - Bulletin ASI 23 Wireless Access Point Mounting All costs associated with Bulletin ASI 23 issued by the design team.    The CO for the WAPs is basically mirroring the same material and installation  as the Security scope. We are taking Fiber from the MDF to each WAP location and converting back to copper. In doing so we will be utilizing local power at the WAP locations for media converters.       ATTACHMENTS: PCO #042 R1 - Bulletin ASI 23.pdf , PCO #042 - Bulletin ASI 23.pdf , Digital Technologies Inc. Proposal_ Change Order- WAPs ASI 23A.pdf #Budget Code Description Amount 1 16-100.S Electrical.Commitment added costs associated with Bulletin ASI 23 issued by the design team $31,680.71 2 16-100.S Electrical.Commitment credit associated with ASI 23 $(4,341.71) 3  credit for reduced conduit by Ornelas electric. 3 guys, 2 days at$94.07/hourly, Equipment/Material = $914 $(5,429.36) Subtotal:$21,909.64 Overhead (7.00% Applies to all line item types.):$1,913.73 Insurance (1.50% Applies to all line item types.):$410.09 Bonding  (1.00% Applies to all line item types.):$296.63 Grand Total:$24,530.09 AMG & Associates Inc.Page 1 of 2 Printed On: 7/19/2023  10:52 AM PCO #042 DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA    City of Rancho Palos Verdes  AMG & Associates, Inc.  30940 Hawthorne Blvd. 26535 Summit Circle    Rancho Palos Verdes, California 90275  Santa Clarita, California 91350             ProcoreArchitectSignHere ProcoreArchitectSignedDate  ProcoreOwnerSignHere ProcoreOwnerSignedDate  ProcoreGeneralContractorSignHere ProcoreGeneralContractorSignedDate SIGNATURE DATE  SIGNATURE DATE  SIGNATURE DATE AMG & Associates Inc.Page 2 of 2 Printed On: 7/19/2023  10:52 AM PCO #042 DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA DIGITAL TECHNOLOGIES, INC. “A Certified SBA 8(a), MBE, SBE, DBE Contractor” DEFINE. DESIGN. DELIVER. Proposal Digital Technologies Inc. 760 S. Rochester Ave Suite E Ontario Ca 91761 909-563-8703 License#894551 DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA DIGITAL TECHNOLOGIES, INC. ABOUT US: Founded in 2002, Digital Technologies Inc. endeavors to provide diverse services that have become all but forgotten in today’s climate. Whether it is in commercial or government markets, our mission is to offer the highest quality products and services that adhere to our customers’ specific needs. We have cultivated a business that specializes in design, engineering, and installation. Catering to our customers’ specific needs is a fundamental cornerstone at Digital Technologies Inc. By providing our customers with the loyalty of a business partner and the economic benefits of an outside vendor, we believe that we are able to serve our clients as a trusted ally. Through the careful selection of top-rated materials and hardware, in conjunction with a well-trained, organized staff, Digital Technologies Inc. gives our clients the assurance that we will be there when they need us. SERVICES: Structured Cabling Fiber Optics Video Surveillance Intrusion Detection Access Control Sound Masking PA Systems Electrical DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA Quote: 1120 / Date: 4/28/2023 Digital Technologies, Inc. 760 S. Rochester Ave., Ste E Ontario, CA 91761, US 909-563-8703 Prepared By: Damian Gutierrez 909-845-8430 dgutierrez@digitaltech.us.com Customer AMG & Associates Inc. 26535 Summit Circle Santa Clarita Ca 91350 Chris Tumasone 661-877-5441 ctumasone@amgassociatesinc.com Project: Ladera Linda Community Center and Park Scope of Work **The following Change Order is for the additional WAPs per ASI 23A plans. The cost proposal is for cabling, Media Converters, Enclosures & labor associated with the scope. **Bollard has a 6-8 week lead time. Structured Cabling Quantity Unit Cost Total Cost Corning 6 Stand Fiber OM3 Manufacturer: Corning, Description: Corning 6-F OM3 10G LT 1,500 ft $ 3.06 $ 4,585.05 6 Port Surface Mount Box Manufacturer: Panduit, Catalog Number: NK6BXIW-AY, Description: 6 Port Surface Mount Box Unloaded 4 ea $ 68.07 $ 272.30 NetKey Network Component Manufacturer: Panduit, Catalog Number: NKDLCMZIW, Description: Keystone LC Duplex Adapter 4 ea $ 74.60 $ 298.40 Comnet C1US Manufacturer: Comnet, Catalog Number: C1US, Description: 19" Rack mount Cage 1 ea $ 1,099.31 $ 1,099.31 Comnet Media Converter Manufacturer: Comnet, Catalog Number: CNGE2MC, Description: Fiber Media Converter 4 ea $ 1,262.80 $ 5,051.20 Comnet 2- Port Media Converter Manufacturer: Comnet, Catalog Number: CNGE2MCPOEM, Description: 2 Port Media Converter 4 ea $ 1,401.51 $ 5,606.05 Comnet SFP Manufacturer: Comnet, Catalog Number: CNGE2MCPOEM, Description: Comnet SFP-SX 1000FX, 850NM LC 2 fiber 8 ea $ 254.06 $ 2,032.50 DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA Quantity Unit Cost Total Cost Comnet PS-AMR1-12 Manufacturer: Comnet, Catalog Number: PS-AMR1-12, Description: 12VDC 10Watt Power Supply 4 ea $ 254.06 $ 1,016.25 Fiber Fan Out Kit Manufacturer: Corning, Catalog Number: FAN-0D25-06, Description: 6 strand Fiber Fan out kit OSP 8 ea $ 116.17 $ 929.40 LC Fiber 1 meter Pigtails Description: LC Fiber 1 meter Pigtails 8 ea $ 86.20 $ 689.60 Oberon Enclosure Manufacturer: Oberon, Catalog Number: 1026-12106-C, Description: Oberon Enclosure 12in Nema 4 Plastic AP Enclosure 4 ea $ 840.11 $ 3,360.45 Oberon Footing Kit Manufacturer: Oberon, Catalog Number: 39-303x, Description: Oberon Footing Kit 1 ea $ 221.96 $ 221.96 Oberon Net Point Bollard Manufacturer: Oberon, Catalog Number: 30-32-LH-GY-48, Description: Oberon Net Point Bollard 1 ea $ 1,511.93 $ 1,511.93 Oberon Work Box Manufacturer: Oberon, Catalog Number: 39-1026-1084, Description: Oberon Work Box 2 ea $ 518.05 $ 1,036.10 Oberon Mounting Plate Kit Manufacturer: Oberon, Catalog Number: 39-303C- COAP6300-KIT, Description: Oberon Mounting Plate Kit 2 ea $ 181.36 $ 362.72 Project Management 12 hrs $ 124.27 $ 1,491.30 Included(+) 1.1. Labor to install, program, and test furnished equipment. 2. Standard Labor (Mon-Fri) 8am-4:30pm. 3. Material Listed in scopes of work. 4. Digital Technologies Inc. Term & Conditions apply. Excluded(-) 1.1. Conduit for Low Voltage System/Security 2. Cutting, Patching & Painting. 3. Low Voltage / Local AHJ Permits. 4. Ceiling Tile Replacement & or Repair. 5. Opening of Walls 6. Power to the Camera Poles and Bollard Notes **Cost Propsoal is based on DIR labor rates. DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA Summary Price Labor and Adjustments $ 9,631.31 Materials $ 21,428.20 Subtotal $ 31,059.52 Others Shipping/Freight $ 621.19 Total Others $ 621.19 $ 31,680.71 Accepted By Date .................................. .................................. DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA DIGITAL TECHNOLOGIES, INC. “A Certified SBA 8(a), MBE, SBE, DBE Contractor” 760 S. Rochester Ave, Suite E * Ontario, CA 91761 * LIC # 894551 * DIR# 1000011268 * Tel 909-563-8703 * Fax 909-657-9153 www.digitaltechnologies-inc.com Digital Technologies, Inc. Terms and Conditions Intellectual Property. This proposal and all accompanying materials, and the original information, designs, concepts and ideas represented herein are the exclusive intellectual property of Digital Technologies, Inc. as per Digital Technologies, Inc. Terms & Conditions. Project acceptance. Digital Technologies, Inc. requires signed agreement or acceptable client purchase order, prior to all work commencement, including parts acquisition or project mobilization. Independent contractor. Digital Technologies, Inc. shall perform our services as an independent contractor and will subcontract some services on a parts and termination basis if needed. Deposit / Mobilization Fee. When agreed upon a deposit of 25% required to initialize the project, purchase equipment and expedite services and resources on projects that exceed $75,000.00 The remainder of the project will be billed on a progressive monthly schedule proportional to the percentage of the project completion. Equipment. Client hereby accepts delivery of such equipment or materials at the point of origin at Digital Technologies, Inc. freight forwarder and assumes ownership of the equipment or materials at such point. This proposal is based on providing material and technical assistance, only as required, an operational system, as specified. Completion and Partial Completion work: At any time during the installation of this project, if Digital Technologies, Inc. completes a usable unit or portion of the work, the occupancy of which will benefit the Owner, Digital Technologies, Inc. may request the Owner to make final inspection of that unit. If the Owner finds upon inspection that the work has been satisfactorily completed in compliance with the Contract, it will be considered completed. Progress payment schedule shall apply to all completed work. The completed system shall be tested in the presence of the owner’s representative. Test forms shall document the results of the test and be signed by both parties. When the final system acceptance test has been satisfactorily completed, the owner shall sign a Letter of Completion issued by Digital Technologies, Inc. Digital Technologies, Inc. shall record the notice of completion as the start of the (1) One, year warranty period. Owner’s decision to use or not use the system at this time does not affect the warranty period. Project Change Order. Additional equipment, labor, and materials required above and beyond the agreed upon Scope of Work included in this proposal will be considered a Change Order and will only be executed upon receipt of written order and will be billed to the Client as an extra charge over and above the original estimate. Project details / RFP specific. In reference to the specification sections, drawings, addendum, and additional documentation detailed in the table below we have generated this document to communicate Digital Technologies Inc. clarifications & assumptions. Scope(s) of work. The final scope(s) of work and work procedures must be verified and agreed upon by all applicable parties prior to Digital Technologies, Inc. initiating fieldwork on the following project. All equipment not itemized on detailed bill of materials will be at additional cost. Warranty. Digital Technologies, Inc. warrants it shall perform its Services in accordance with the current standards of care and diligence normally practiced by professionals in performing services of a similar nature. All equipment provided by Digital Technologies, Inc. will carry a one (1) year warranty from the date of completion, unless extended warranties are executed. All labor used to install equipment listed will carry a one (1) year warranty from date of completion, unless extended warranties are executed. Warranty becomes voided if serviced by an alternative company while under the one (1) year time frame. Permits. Permits and plan check are not included in this proposal unless noted. Bonding. Digital Technologies, Inc. will not be responsible for project bonding and special insurances, which are not specifically identified in the RFP documentation. Cabling. All low voltage cabling will be plenum rated and run above the ceiling without conduit, unless specified. Electrified Locking Hardware. All locking hardware to be provided and installed by others unless specified in the following scope of work. Client Responsibilities and Acknowledgements. Every proposal requires certain parts, pieces, or labor to be provided by Client. Digital Technologies, Inc. has made every attempt to list the responsibilities of Client in this proposal. These responsibilities may include, but are not limited to, AC power connections, lighting conditions, network drops, or IP addresses, and structural integrity. Installation. Digital Technologies, Inc. assumes that the hours of installation unless agreed upon are the hours of 7am to 4pm, Monday through Friday, exclusive of holidays. Unless specifically stated herein otherwise. Client shall incur additional charges for work required outside of these time frames. Overtime required for additional out of scope work, testing, or technical assistance will be billed separately. Existing Equipment. Digital Technologies, Inc. assumes no responsibility for existing equipment installed by others, including cameras, power supplies, enclosure, access panel(s), NVR’s, DVR’s and cabling and or Network DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA 760 S. Rochester Ave, Suite E * Ontario, CA 91761 * LIC # 894551 * DIR# 1000011268 * Tel 909-563-8703 * Fax 909-657-9153 www.digitaltechnologies-inc.com Infrastructure. Lock operation is subject to the proper condition, operation of door hardware, door alignment, and closing devices. Access Control is contingent upon proper operation of all such devices and hardware. Factors such as air conditioning, wind or related draft problems and abusive usage can render any system inoperative. Eliminating and preventing these interfering factors is the responsibility of the customer. Site access. Digital Technologies, Inc. requires full and complete access to the subject property and designated work areas per our scope(s) of work. Accommodations. All utilities, such as electric and water, utility connections, building and facility services, space for temporary storage, site security, and bathroom facilities at the subject location listed above at no cost to Digital Technologies, Inc. for the duration of the project. Patch/Paint Exclusion. Unless specifically stated herein, Digital Technologies, Inc. has not included provisions to provide any patching of walls or painting. All Patching, painting, concrete, masonry, ceiling removals/replacements, temporary protections and debris removal is not included. Damages. Customer at the location will verify, identify, and mark-out all utilities and structures, such as but not limited to, foundations, pilings, vaults, and pipes in and near the work areas. Digital Technologies, Inc. is not responsible for the direct or indirect costs associated with damage and/or repair of utility lines and structures not identified, verified, and marked-out by the customer at the site location. Asbestos. All work areas are assumed to be free of lead and asbestos. This proposal does not include Asbestos work, removal, and or filing. All expending costs for services and treatment will be the responsibility of others. Material. Where the delivery of materials, components, or goods required under this agreement is delayed through no fault of Di gital Technologies, Inc. Because of shortage of commodities, raw materials, components, and/or products, Digital Technologies, Inc. shall not be liable for any additional costs or damages associated with such delay(s). Digital Technologies, Inc. will not be responsible stand-by time/waiting time, demobilization / remobilization, fire watch, site security, building/facility services, interference/delay from trades/unions or other parties, and/or stand-by trades/unions. Building Risers /Pathways. All Pathways are assumed to be free and clear of obstructions. Climate Control. Proper level of air conditioning and ventilation must be provided for all areas in which security equipment is installed. These areas include, but are not limited to security room, racks & consoles, closets, elevator machine rooms, etc. lighting conditions are anticipated to be adequate and proper for the operation of CCTV cameras. Drawings. Client shall provide Digital Technologies, Inc. with an electronic version of drawings for the performance of the Services. Client shall provide Digital Technologies, Inc. to-scale AUTOCAD drawings in electronic format. If Client cannot provide these drawings, an additional charge may accrue for Digital Technologies, Inc. to create drawings necessary for the completion of the Services. Insurance. Each Party shall take out and maintain at its own expense all insurance necessary to cover its obligations under the Agreement. Digital Technologies, Inc. will not be responsible for project bonding and special insurances, which are not specifically identified in the RFP documentation. Customer shall purchase and maintain all-risk builder’s risk insurance upon the full value of the entire work, including materials delivered to the job site, as per Digital Technologies, Inc. Terms & Conditions. Liability. Digital Technologies, Inc. shall hold Client harmless against all claims, demands and causes of action for injury to or death of persons or for damage to tangible property (other than property of Client) to the extent caused by the negligent acts of Digital Technologies, Inc. Digital Technologies, Inc. Liability under this Agreement shall not exceed the compensation paid by Client to Digital Technologies, Inc. under this Agreement, and, fully permitted by law, Client agrees to release, defend, and hold Digital Technologies, Inc. and its affiliates and each of their respective successors, assigns, employees, agents, officers and directors harmless from and against any and all further liability arising in any manner from this Agreement and Digital Technologies, Inc. performance of the Services. Digital Technologies, Inc. shall not be responsible for delays or defaults that are occasioned by causes of any kind beyond Digital Technologies, Inc. reasonable control, including but not limited to delays or defaults of architects, the customer or customer’s landlord, other contractors or subcontractors, any other third parties, or by civil disorder, labor dispute, or Act of God. Digital Technologies, Inc. shall be entitled to equitable adjustment in the amount of the Contract for delays caused by any such party or cause. DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA DIGITAL TECHNOLOGIES, INC. “A Certified SBA 8(a), MBE, SBE, DBE Contractor” DEFINE. DESIGN. DELIVER. Proposal Digital Technologies Inc. 760 S. Rochester Ave Suite E Ontario Ca 91761 909-563-8703 License#894551 DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA DIGITAL TECHNOLOGIES, INC. ABOUT US: Founded in 2002, Digital Technologies Inc. endeavors to provide diverse services that have become all but forgotten in today’s climate. Whether it is in commercial or government markets, our mission is to offer the highest quality products and services that adhere to our customers’ specific needs. We have cultivated a business that specializes in design, engineering, and installation. Catering to our customers’ specific needs is a fundamental cornerstone at Digital Technologies Inc. By providing our customers with the loyalty of a business partner and the economic benefits of an outside vendor, we believe that we are able to serve our clients as a trusted ally. Through the careful selection of top-rated materials and hardware, in conjunction with a well-trained, organized staff, Digital Technologies Inc. gives our clients the assurance that we will be there when they need us. SERVICES: Structured Cabling Fiber Optics Video Surveillance Intrusion Detection Access Control Sound Masking PA Systems Electrical DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA Quote: 1151 / Date: 4/28/2023 Digital Technologies, Inc. 760 S. Rochester Ave., Ste E Ontario, CA 91761, US 909-563-8703 Prepared By: Damian Gutierrez 909-845-8430 dgutierrez@digitaltech.us.com Customer AMG & Associates Inc. 26535 Summit Circle Santa Clarita Ca 91350 Chris Tumasone 661-877-5441 ctumasone@amgassociatesinc.com Project: Ladera Linda Community Center and Park Scope of Work **The following is a Credit for the Cat-6A OSP cabling to each WAP (6 total) per sheet T1.01 dated 11/29/2021, undert the original scope of work. The credit includes material a labor associted with the credit. **There is no credit for the NEMA enclosres as per Refrence Note #3 it states "not used". Was not included in original scope of work. Structured Cabling Quantity Unit Cost Total Cost CAT-6A OSP Cable Manufacturer: Corning, Description: Cat-6A OSP Cable -3,000 ft $ 1.38 $ -4,126.08 Included(+) 1.1. Labor to install, program, and test furnished equipment. 2. Standard Labor (Mon-Fri) 8am-4:30pm. 3. Material Listed in scopes of work. 4. Digital Technologies Inc. Term & Conditions apply. Excluded(-) DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA Excluded(-) 1.1. Conduit for Low Voltage System/Security 2. Cutting, Patching & Painting. 3. Low Voltage / Local AHJ Permits. 4. Ceiling Tile Replacement & or Repair. 5. Opening of Walls 6. Power to the Camera Poles and Bollard Notes **Cost Propsoal is based on DIR labor rates. Summary Price Labor and Adjustments $ -2,386.08 Materials $ -1,870.50 Subtotal $ -4,256.58 Others Shipping/Freight $ -85.13 Total Others $ -85.13 $ -4,341.71 Accepted By Date .................................. .................................. DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA DIGITAL TECHNOLOGIES, INC. “A Certified SBA 8(a), MBE, SBE, DBE Contractor” 760 S. Rochester Ave, Suite E * Ontario, CA 91761 * LIC # 894551 * DIR# 1000011268 * Tel 909-563-8703 * Fax 909-657-9153 www.digitaltechnologies-inc.com Digital Technologies, Inc. Terms and Conditions Intellectual Property. This proposal and all accompanying materials, and the original information, designs, concepts and ideas represented herein are the exclusive intellectual property of Digital Technologies, Inc. as per Digital Technologies, Inc. Terms & Conditions. Project acceptance. Digital Technologies, Inc. requires signed agreement or acceptable client purchase order, prior to all work commencement, including parts acquisition or project mobilization. Independent contractor. Digital Technologies, Inc. shall perform our services as an independent contractor and will subcontract some services on a parts and termination basis if needed. Deposit / Mobilization Fee. When agreed upon a deposit of 25% required to initialize the project, purchase equipment and expedite services and resources on projects that exceed $75,000.00 The remainder of the project will be billed on a progressive monthly schedule proportional to the percentage of the project completion. Equipment. Client hereby accepts delivery of such equipment or materials at the point of origin at Digital Technologies, Inc. freight forwarder and assumes ownership of the equipment or materials at such point. This proposal is based on providing material and technical assistance, only as required, an operational system, as specified. Completion and Partial Completion work: At any time during the installation of this project, if Digital Technologies, Inc. completes a usable unit or portion of the work, the occupancy of which will benefit the Owner, Digital Technologies, Inc. may request the Owner to make final inspection of that unit. If the Owner finds upon inspection that the work has been satisfactorily completed in compliance with the Contract, it will be considered completed. Progress payment schedule shall apply to all completed work. The completed system shall be tested in the presence of the owner’s representative. Test forms shall document the results of the test and be signed by both parties. When the final system acceptance test has been satisfactorily completed, the owner shall sign a Letter of Completion issued by Digital Technologies, Inc. Digital Technologies, Inc. shall record the notice of completion as the start of the (1) One, year warranty period. Owner’s decision to use or not use the system at this time does not affect the warranty period. Project Change Order. Additional equipment, labor, and materials required above and beyond the agreed upon Scope of Work included in this proposal will be considered a Change Order and will only be executed upon receipt of written order and will be billed to the Client as an extra charge over and above the original estimate. Project details / RFP specific. In reference to the specification sections, drawings, addendum, and additional documentation detailed in the table below we have generated this document to communicate Digital Technologies Inc. clarifications & assumptions. Scope(s) of work. The final scope(s) of work and work procedures must be verified and agreed upon by all applicable parties prior to Digital Technologies, Inc. initiating fieldwork on the following project. All equipment not itemized on detailed bill of materials will be at additional cost. Warranty. Digital Technologies, Inc. warrants it shall perform its Services in accordance with the current standards of care and diligence normally practiced by professionals in performing services of a similar nature. All equipment provided by Digital Technologies, Inc. will carry a one (1) year warranty from the date of completion, unless extended warranties are executed. All labor used to install equipment listed will carry a one (1) year warranty from date of completion, unless extended warranties are executed. Warranty becomes voided if serviced by an alternative company while under the one (1) year time frame. Permits. Permits and plan check are not included in this proposal unless noted. Bonding. Digital Technologies, Inc. will not be responsible for project bonding and special insurances, which are not specifically identified in the RFP documentation. Cabling. All low voltage cabling will be plenum rated and run above the ceiling without conduit, unless specified. Electrified Locking Hardware. All locking hardware to be provided and installed by others unless specified in the following scope of work. Client Responsibilities and Acknowledgements. Every proposal requires certain parts, pieces, or labor to be provided by Client. Digital Technologies, Inc. has made every attempt to list the responsibilities of Client in this proposal. These responsibilities may include, but are not limited to, AC power connections, lighting conditions, network drops, or IP addresses, and structural integrity. Installation. Digital Technologies, Inc. assumes that the hours of installation unless agreed upon are the hours of 7am to 4pm, Monday through Friday, exclusive of holidays. Unless specifically stated herein otherwise. Client shall incur additional charges for work required outside of these time frames. Overtime required for additional out of scope work, testing, or technical assistance will be billed separately. Existing Equipment. Digital Technologies, Inc. assumes no responsibility for existing equipment installed by others, including cameras, power supplies, enclosure, access panel(s), NVR’s, DVR’s and cabling and or Network DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA 760 S. Rochester Ave, Suite E * Ontario, CA 91761 * LIC # 894551 * DIR# 1000011268 * Tel 909-563-8703 * Fax 909-657-9153 www.digitaltechnologies-inc.com Infrastructure. Lock operation is subject to the proper condition, operation of door hardware, door alignment, and closing devices. Access Control is contingent upon proper operation of all such devices and hardware. Factors such as air conditioning, wind or related draft problems and abusive usage can render any system inoperative. Eliminating and preventing these interfering factors is the responsibility of the customer. Site access. Digital Technologies, Inc. requires full and complete access to the subject property and designated work areas per our scope(s) of work. Accommodations. All utilities, such as electric and water, utility connections, building and facility services, space for temporary storage, site security, and bathroom facilities at the subject location listed above at no cost to Digital Technologies, Inc. for the duration of the project. Patch/Paint Exclusion. Unless specifically stated herein, Digital Technologies, Inc. has not included provisions to provide any patching of walls or painting. All Patching, painting, concrete, masonry, ceiling removals/replacements, temporary protections and debris removal is not included. Damages. Customer at the location will verify, identify, and mark-out all utilities and structures, such as but not limited to, foundations, pilings, vaults, and pipes in and near the work areas. Digital Technologies, Inc. is not responsible for the direct or indirect costs associated with damage and/or repair of utility lines and structures not identified, verified, and marked-out by the customer at the site location. Asbestos. All work areas are assumed to be free of lead and asbestos. This proposal does not include Asbestos work, removal, and or filing. All expending costs for services and treatment will be the responsibility of others. Material. Where the delivery of materials, components, or goods required under this agreement is delayed through no fault of Di gital Technologies, Inc. Because of shortage of commodities, raw materials, components, and/or products, Digital Technologies, Inc. shall not be liable for any additional costs or damages associated with such delay(s). Digital Technologies, Inc. will not be responsible stand-by time/waiting time, demobilization / remobilization, fire watch, site security, building/facility services, interference/delay from trades/unions or other parties, and/or stand-by trades/unions. Building Risers /Pathways. All Pathways are assumed to be free and clear of obstructions. Climate Control. Proper level of air conditioning and ventilation must be provided for all areas in which security equipment is installed. These areas include, but are not limited to security room, racks & consoles, closets, elevator machine rooms, etc. lighting conditions are anticipated to be adequate and proper for the operation of CCTV cameras. Drawings. Client shall provide Digital Technologies, Inc. with an electronic version of drawings for the performance of the Services. Client shall provide Digital Technologies, Inc. to-scale AUTOCAD drawings in electronic format. If Client cannot provide these drawings, an additional charge may accrue for Digital Technologies, Inc. to create drawings necessary for the completion of the Services. Insurance. Each Party shall take out and maintain at its own expense all insurance necessary to cover its obligations under the Agreement. Digital Technologies, Inc. will not be responsible for project bonding and special insurances, which are not specifically identified in the RFP documentation. Customer shall purchase and maintain all-risk builder’s risk insurance upon the full value of the entire work, including materials delivered to the job site, as per Digital Technologies, Inc. Terms & Conditions. Liability. Digital Technologies, Inc. shall hold Client harmless against all claims, demands and causes of action for injury to or death of persons or for damage to tangible property (other than property of Client) to the extent caused by the negligent acts of Digital Technologies, Inc. Digital Technologies, Inc. Liability under this Agreement shall not exceed the compensation paid by Client to Digital Technologies, Inc. under this Agreement, and, fully permitted by law, Client agrees to release, defend, and hold Digital Technologies, Inc. and its affiliates and each of their respective successors, assigns, employees, agents, officers and directors harmless from and against any and all further liability arising in any manner from this Agreement and Digital Technologies, Inc. performance of the Services. Digital Technologies, Inc. shall not be responsible for delays or defaults that are occasioned by causes of any kind beyond Digital Technologies, Inc. reasonable control, including but not limited to delays or defaults of architects, the customer or customer’s landlord, other contractors or subcontractors, any other third parties, or by civil disorder, labor dispute, or Act of God. Digital Technologies, Inc. shall be entitled to equitable adjustment in the amount of the Contract for delays caused by any such party or cause. DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA Ladera Linda Community Center & Park City of Rancho Palos Verdes, CA Project Submittals, Installation By: A Certified SBA 8(a), MBE, SBE, DBE Contractor” 760 S. Rochester Ave, Suite E * Ontario, CA 91761 * Lic # 894551 * DIR# 1000011268 * Tel 909-563-8703 * Fax 909-657-9153 www.digitaltechnologies-inc.com WAPs ASI 23A Material Submittal DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA Part Number: 006TSF-T4180D20 Cross Section of Part Number: 006TSF-T4180D20 FR / UV-Resistant Outer Jacket Ripcord Fiber Buffer Tube Dielectric Strength Members 210.6279 Corning Cable Systems FREEDM® LST™ Gel -Free Cables are flame -retardant, indoor/outdoor, riser -rated cables designed for interbuilding and intrabuilding back- bones in aerial, duct and riser applications. With a riser rating, there is no need for a transition splice when enter- ing the building. Available in a compact design, these cables are protected against water penetration by inno- vative waterblocking tapes and yarns that swell to absorb water. Waterblocking without the use of messy gels pro- vides more efficient and craft -friendly cable preparation, allows easier cable access and simplifies the use of buf- fer tube fan -out kits. The buffer tubes and fibers in each tube are color -coded for quick, easy identification. The SZ -stranded, loose tube design isolates fibers from installation and environmental rigors and allows for easy midspan access. The cable design is also National Electrical Code® (NEC®) listed (OFNR and FT -4). The all -dielectric cable construction requires no grounding or bonding and the UV -resistant, flame -retardant jacket is rugged, durable and easy to strip. This cable is available in 12 different jacket colors - blue, orange, green, brown, slate, white, red, black, yellow, purple, rose and aqua. The colored jacket allows for easy visual identification of the cables while still providing all of the required environmental protection of an indoor/ outdoor cable jacket. Black is the standard jacket color using the standard part numbers shown here. Contact Customer Care at 1 -800 -743 -2675 to order other color options. Corning Cable Features and Benefits Riser rating No transition splices when entering buildings Gel-free waterblocking technology Craft-friendly cable preparation Color-coded fibers Quick and easy identification All-dielectric construction Requires no grounding or bonding UV-resistant, flame-retardant jacket Rugged, durable and easy to strip 1 1 FREEDM® LST™ Single-Tube, Gel-Free Cable, Riser 6 F, 50 µm multimode (OM3) Product Specification 006TSF-T4180D20_NAFTA_AEN Page 1 | Revision date 2012-08-25 Part Number: 006TSF-T4180D20 DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA Standards Approval and Listings National Electrical Code® (NEC®) OFNR, CSA OFN FT-4 Common Installations Outdoor lashed aerial and duct; indoor vertical riser and general purpose hori- zontal according to National Electrical Code® (NEC) Article 770 Design and Test Criteria ANSI/ICEA S-104-696 44.134 115 1 1 False Specifications General Specifications Environment Indoor/Outdoor Cables Application Aerial, Direct Buried, Duct, General Purpose Horizontal, (Vertical Riser) Cable Type Loose Tube Product Type Dielectric Flame Rating Riser (OFNR) Fiber Category 50 µm MM (OM3) Temperature Range Storage -40 °C to 70 °C (-40 °F to 158 °F) Installation -10 °C to 60 °C (14 °F to 140 °F) Operation -40 °C to 70 °C (-40 °F to 158 °F) Cable Design Fiber Count 6 Fiber Coloring Blue, Orange, Green, Brown, Slate, White Fibers per Tube 6 Number of Tube Positions 1 Number of Active Tubes 1 Tensile Strength Elements and/or Armoring - Layer 1 Dielectric strength members Tensile Strength Elements and/or Armoring - Layer 2 Water-swellable dielectric strength members Number of Ripcords 1 FREEDM® LST™ Single-Tube, Gel-Free Cable, Riser 6 F, 50 µm multimode (OM3) Product Specification 006TSF-T4180D20_NAFTA_AEN Page 2 | Revision date 2012-08-25 DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA Cable Design Outer Jacket Material Flame-Retardant, UV-Resistant Outer Jacket Color Black Mechanical Characteristics Cable Weight 56 kg/km (38 lb/1000 ft) Nominal Outer Diameter 7.4 mm (0.29 in) Max. Tensile Strengths, Short-Term 1350 N (300 lbf) Max. Tensile Strengths, Long-Term 400 N (90 lbf) Min. Bend Radius Installation 111 mm (4.4 in) Min. Bend Radius Operation 37 mm (1.5 in) Chemical Characteristics RoHS Free of hazardous substances according to RoHS 2002/95/ EG Fiber Specifications Optical Characteristics (cabled) Fiber Type Multimode Fiber Core Diameter 50 µm Fiber Category OM3 Fiber Code T Performance Option Code 80 Wavelengths 850 nm / 1300 nm Maximum Attenuation 3.0 dB/km / 1.0 dB/km Min. Overfilled Launch (OFL) Bandwidth 1500 MHz*km / 500 MHz*km Minimum Effective Modal Bandwidth (EMB)2000 MHz*km / - Serial 1 Gigabit Ethernet 1000 m / 600 m Serial 10 Gigabit Ethernet 300 m / - * Meets 0.75 ns optical skew when used in all Corning Cable Systems Plug & Play™/Pretium EDGE® Systems Solutions. Notes: 1) 50 μm multimode fiber macrobend loss ≤ 0.2 dB at 850 nm for two turns around 7.5 mm radius mandrel. 2) Improved attenuation and bandwidth options available. 3) Bend-insensitive single-mode fibers available on request. 4) Contact a Corning Cable Systems Customer Care Representative for additional information. FREEDM® LST™ Single-Tube, Gel-Free Cable, Riser 6 F, 50 µm multimode (OM3) Product Specification 006TSF-T4180D20_NAFTA_AEN Page 3 | Revision date 2012-08-25 DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA Ordering Information Part Number 006TSF-T4180D20 Product Description FREEDM® LST™ Single-Tube, Gel-Free Cable, Riser, 6 F, 50 µm multimode (OM3) FREEDM® LST™ Single-Tube, Gel-Free Cable, Riser 6 F, 50 µm multimode (OM3) Product Specification 006TSF-T4180D20_NAFTA_AEN Page 4 | Revision date 2012-08-25 Corning Cable Systems LLC • PO Box 489 • Hickory, NC 28603-0489 USA 800-743-2675 • FAX: 828-325-5060 • International: +1-828-901-5000 • www.corning.com/cablesystems A complete listing of the trademarks of Corning Cable Systems is available at www.corning.com/cablesystems/trademarks. Corning Cable Systems is ISO 9001 certified. © 2012 Corning Cable Systems. All rights reserved. DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA Part Number Compatible Raceway No. of Adhesive Strips No. of Cable Ties Label/Label Cover Included Mounting Screws Included Magnet Pockets NK2BX LD3, LD5 1 1 No Yes 1 NK4BX LD3, LD5 2 2 Yes Yes 2 NK6BX LD3, LD5 2 2 Yes Yes None NetKey ® Surface Mount Boxes www.panduit.com DATA SHEET specifications Surface mount boxes shall have a low profile design and shall be available in a variety of port densities. Boxes shall accept all NetKey Keystone Modules for fiber, copper, audio, and video applications. The boxes shall mount with screws, adhesive, or optional magnets and shall include breakouts for use with surface raceway. Cable tie slots shall be included to provide strain relief on incoming cables. technical information Mounting options:Mounts easily with screws, adhesive tape, or optional magnet Material:Box is made of ABS key features and benefits Modular Accepts all NetKey Keystone Modules which snap in and out for easy moves, adds, and changes Low profile design Presents a more discreet or inconspicuous look Raceway breakouts Compatible with specific surface raceway, conceals cable entering the box Cover screw Select boxes provide a screw that secures the cover to the base Labels and label covers Select boxes include a label pocket to meet labeling standards Magnet pockets Accept magnets for mounting on metal surfaces; NK2BX*-A, NK4BX*-AY applications NetKey Surface Mount Boxes offer a variety of mounting options, allowing NetKey Keystone Modules to mount on a variety of surfaces such as standard walls, metal surfaces, office furniture and more. Surface mount boxes include Surface Raceway compatible breakouts to allow cable to run discretely into the box to provide a point of connection for voice, video, and data applications. NetKey Surface Mount Boxes* 2-port:NK2BXIW-A^ 4-port:NK4BXIW-AY 6-port:NK6BXIW-AY Accessories Blank Module:NKBMIW-X-L Magnet:CBM-X *For standard colors other than IW (Off White), replace suffix with EI (Electric Ivory), WH (White), IG (International Gray), or BL (Black). ^Suitable for air handling spaces. DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA Post for tamper resistant screw Breakout Area (3 Places) Mounting holes for #6 Pan Head screw (11 Places) Pan-Ty Loop for cable hold-down (4 Places) 6.66 [169.2] 3.28 [83.3] 1.26 [32.0]4.70 [119.4] 1.95 [49.5] 3.65 [92.7] 1.12 [28.6] 1.93 [48.9] 2.36 [60.0] 1.80 [45.7] 3.58 [90.8] 2-Port Surface Mount Box NK2BXIW-A Pan-Ty Loop for cable hold-down (4 places) Post for tamper resistant screw Drawing shown with blank module breakout. Remove breakout for two positions. Breakout area (3 Places) Mounting holes for #6 Pan Held screw (2 places) 3.28 [83.3] 3.26 [82.8]1.23 [31.2] 4-Port Surface Mount Box NK4BXIW-AY 6-Port Surface Mount Box NK6BXIW-AY NetKey® Surface Mount Boxes Dimensions are in inches. [Dimensions in brackets are metric]. WORLDWIDE SUBSIDIARIES AND SALES OFFICES PANDUIT US/CANADA Phone: 800.777.3300 PANDUIT EUROPE LTD. London, UK Phone: 44.20.8601.7200 PANDUIT SINGAPORE PTE. LTD. Republic of Singapore Phone: 65.6305.7575 PANDUIT JAPAN Tokyo, Japan Phone: 81.3.6863.6000 PANDUIT LATIN AMERICA Guadalajara, Mexico Phone: 52.33.3777.6000 PANDUIT AUSTRALIA PTY. LTD. Victoria, Australia Phone: 61.3.9794.9020 For a copy of Panduit product warranties, log on to www.panduit.com/warranty For more information Visit us at www.panduit.com Contact Customer Service by email: cs@panduit.com or by phone: 800.777.3300 ©2022 Panduit Corp. ALL RIGHTS RESERVED. NKDS45-WW-ENG 10/2022 DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA www.panduit.com DATA SHEET specifications key features and benefits Integrated panel retention clips: No metal clips to become bent, damaged or lost; simplex adapter clips automatically adjust for FOCIS-3 or FOCIS-10 panel thickness variations for improved mounting Short flange design (LC and SC only): Improved modularity and higher density usage Choice of phosphor bronze or zirconia ceramic split sleeves: Provides an adapter split sleeve material option to fit specific network requirements Adapters available in keystone modules: System flexibility; modules are interchangeable with keystone outlets, boxes, and patch panels Adapters and modules available in multiple colors: Allows color-coding for network segregation technical information Standards requirements: All adapters meet or exceed TIA/EIA-455-21 and TIA/EIA-568-C.3 requirements: LC: TIA/EIA-604 FOCIS-10 compatible SC: TIA/EIA-604 FOCIS-3 compliant ST: TIA/EIA-604 FOCIS-2 compatible Split sleeve material: Zirconia ceramic: OM3 multimode adapters, OS1/OS2 singlemode adapters Phosphor bronze: OM1 and OM2 multimode adapters Insertion loss:Supports the performance of connectors/patch cords Return loss:Supports singlemode and multimode connector polish performance applications • Can be used with keystone telecommunications room products and work area outlets • Provides a rugged solution for LANs, public networks and fiber-to-the-desk applications NetKey ® LC Duplex Fiber Optic Adapter Module LC duplex adapter with phosphor bronze split sleeve: NKDLCM** LC duplex adapter with zirconia split sleeve: NKDLCMZ** NetKey ® SC Simplex Fiber Optic Adapter Module SC simplex adapter with phosphor bronze split sleeve: NKSCM** SC simplex adapter with zirconia split sleeve: NKSCMZ** NetKey ® ST Fiber Optic Adapter Modules ST adapter with phosphor bronze split sleeve: NKSTM** NetKey ® Module Multimedia Panel – 6 port Unloaded panel accepts up to six NetKey ® Modules: FKP6 ** Substitute for module color BL = Black EI = Electric Ivory IG = International Gray IW = Off White WH = White AQ = Aqua NetKey® Fiber Optic Adapter Modules LC, SC and ST fiber optic adapters have integrated panel retention clips and are TIA/EIA-604 compliant or compatible. Each simplex adapter will connect one connector pair in one module space and each duplex adapter will connect two LC connector pairs in one module space. LC fiber optic adapters and adapter modules include phosphor bronze split sleeves for OM1 or OM2 multimode applications or zirconia ceramic split sleeves for OM3 multimode or singlemode applications. DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA NetKey® Fiber Optic Adapter Modules ©2016 Panduit Corp. ALL RIGHTS RESERVED. NKDS20--WW-ENG 11/11/2016 WORLDWIDE SUBSIDIARIES AND SALES OFFICES For a copy of Panduit product warranties, log on to www.panduit.com/warranty PANDUIT CANADA Markham, Ontario Phone: 800.777.3300 PANDUIT EUROPE LTD. London, UK Phone: 44.20.8601.7200 PANDUIT JAPAN Tokyo, Japan Phone: 81.3.6863.6000 PANDUIT SINGAPORE PTE. LTD. Republic of Singapore Phone: 65.6305.7575 PANDUIT AUSTRALIA PTY. LTD. Victoria, Australia Phone: 61.3.9794.9020 PANDUIT LATIN AMERICA Guadalajara, Mexico Phone: 52.33.3777.6000 iai@panduit.com Visit us at www.panduit.com /ia NKSCM** Shown without dust caps NKDLCM** Shown without dust caps NKSTM** ** Substitute for module color BL = Black, EI = Electric Ivory, IG = International Gray, IW = Off White, WH = White DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA 3 CORPORATE DRIVE | DANBURY, CONNECTICUT 06810 | USA | T: 203.796.5300 | F: 203.796.5303 | TECH SUPPORT: 1.888.678.9427 | INFO@COMNET.NET 8 TURNBERRY PARK ROAD | GILDERSOME | MORLEY | LEEDS, UK LS27 7LE | T: +44 (0)113 307 6400 | F: +44 (0)113 253 7462 | INFO-EUROPE@COMNET.NET SPECIFICATIONS ORDERING INFORMATION FEATuRES › Automatic electronic current limiting feature › Voltage transient protection on all power and signal input/ output lines provides unconditional protection from power surges and other voltage transient events. › (14) Fourteen 1-inch rack slots available › All modules located within the chassis rack are hot- swappable › Lifetime Warranty The design approach employed by ComNet™ for equipment mounted within the card cage rack unit (C1-CH) with modular power supply (C1PS), provides for the elimination of a single-point failure in the event of a major fault within any module located within the chassis rack. This is accomplished through the use of automatic electronic current limiting within each rack-mountable module, rather than providing the current limiting within the power supply unit which supports the power requirements for equipment located within the rack. In nearly all competing designs,a major fault within a module, located within the chassis rack, results in the power supply unit going into a current limiting condition, and as a result, all of the modules within the rack shut down. The rack design employed by ComNet eliminates this possibility, as only the faulty module shuts down, and the operation of the other modules within the rack continue unimpaired. This automatic current limiting feature is also self-resetting, should the fault or overload be of a temporary or intermittent condition. Furthermore, all modules located within the chassis rack are hot-swappable, so that it is not necessary to power-down the rack when removing or replacing modules. C1 Rack Mount Card Cage With Power Supply Electrical Input Voltage 90-264 VAC @ 70 W Maximum Output Voltage 9 VDC +/- 5% @ 6.5 Amps @ 75˚C Fusing 1.25 A slow blow (rack power supply) Plug-in modules individually electronically fused. Each power supply unit is individually fused. Power Indicator Red LED AC Line Cord Detachable, IEC-connected. Allows easy field replacement or exchange for various worldwide AC power plug configurations. Mechanical Size (L × W × H) Rack Mount: 19.0 × 7.5 × 6.9 in. (48.2 × 19 × 17.5 cm) Rack Slots: (14) 1-inch slots available Shipping Weight: <5 lbs./2.15 kg Environmental MTBF >100,000 hours Operating Temp -40˚ C to +75˚ C Storage Temp -40˚ C to +85˚ C Heat Generation 240 BTU AGENCY COMPLIANCE* *Power Supply Only In a continuing effort to improve and advance technology, product specifications are subject to change without notice. Part Number Description C1-US 19” Rack (US AC Power Cord) C1-EU 19” Rack (EU & UK Power Cord) C1-IN 19” Rack (US, EU, UK & AU Power Cord) C1-CH 19” Rack (no power supply) C1PS Spare 90-264 VAC Input Power Supply (order power cords separately) Included Accessories 90-264 VAC Input (includes power supply and power cord) Included with C1-US, C1-EU and C1-IN only Options C1-BP – Blank Panel (1”) C1-BP2 – Blank Panel (2”) C1-BP3 – Blank Panel (3”) C1-SA – South African Power Cord C1-AU – Australian Power Cord DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA LIFETIME WARRANTY WWW.COMNET.NET TECH SUPPORT: 1.888.678.9427 FEATURES › Lifetime Warranty › Full-duplex transmission of 10/100/1000 Mbps Ethernet -10/100/1000 BASE-TX electrical port - 1000 BASE-FX optical port when used with suitable ComNet SFPs › IEEE 802.3 compliant › 10/100/1000 BASE-TX port supports auto-negotiation and automatic MDI/MDI-X crossover for full and half-duplex operation › Uses customer-installed ComNet SFPs for compatibility with a wide range of optical fibers, optical connector types, and optical transmission distances of up to 120 km (SFPs ordered separately) › Designed for installation in harsh out-of-plant/ unconditioned industrial or roadside operating environments (-40º to +75ºC ambient). Fully compliant with the environmental requirements of NEMA TS-2 for Traffic Signal Control Equipment › Voltage transient protection on all power and signal input/ output line provide protection from voltage surges and other transient events › CNGE2MC and CNGE22MC are packaged in the exclusive ComNet ComFit housing, and may be shelf, rack, or DIN-rail mounted, and are hot-swappable when rack-mounted › The 4-port count of the CNGE22MC makes this unit ideal for those applications where rack density or shelf-space may be limited. › Mini-package size of the CNGE2MC-M allows the unit to be installed in those locations where space is at a premium. › LED status indicators for rapidly ascertaining the operating status of the media convertor and the link › Made in the USA APPLICATIONS › Optical transmission of Ethernet-compatible industrial security access control systems, intercom systems, VOIP (Voice over IP) telephony networks, and IP-compatible CCTV camera surveillance networks › Optical Ethernet transmission to wireless LAN access points › Industrial Security, Transportation/ITS, and Industrial Control/Factory Automation IP Networks › Optical transmission of any Ethernet-compatible equipment with a maximum data rate of 1000 Mbps The ComNet™ CNGE2MC and CNGE22MC are one-channel and two-channel, Gigabit Ethernet electrical to optical media converters. These auto-negotiating devices accept a 10/100/1000 Mbps electrical input and convert this to a 1000 Mbps (1Gbs) optical output. These units use ComNet SFPs* (small form-factor pluggable) modules for fiber and connector type, and distance. LED indicators confirm operational status. All models are environmentally hardened with no electrical or optical adjustments (Plug and Play). Packaged in the exclusive ComNet ComFit housing, the standard size units may be either wall or rack mounted. The CNGE2MCM is available in a small size package. The units are powered by an included 8-15VDC power supply. CNGE2MC[M] & CNGE22MC 10/100/1000 Mbps Ethernet Media Converters 1 OR 2CONVERTERHARDENEDFLEXIBILITYINCLUDED * Small Form-Factor Pluggable Module. Sold separately. DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA 05 Dec 2013© 2013 Communication Networks. All Rights Reserved. “ComNet,” the “ComNet Logo,” “NetWave” and the “NetWave Logo” are registered trademarks of Communication Networks. 3 CORPORATE DRIVE | DANBURY, CONNECTICUT 06810 | USA | T: 203.796.5300 | F: 203.796.5303 | TECH SUPPORT: 1.888.678.9427 | INFO@COMNET.NET 8 TURNBERRY PARK ROAD | GILDERSOME | MORLEY | LEEDS, UK LS27 7LE | T: +44 (0)113 307 6400 | F: +44 (0)113 253 7462 | INFO-EUROPE@COMNET.NET CNGE2MC[M] & CNGE22MC 10/100/1000 Mbps Ethernet Media Converters SPECIFICATIONS Data Data Interface Ethernet Data Rate 10/100/1000 Mbps IEEE 802.3 Compliant Full Duplex or Half Duplex Electrical Port/Full Duplex Optical Port Fibers SFP Dependent Fiber Connectors¹ Requires selection of sold-separately SFP modules. See ComNet data sheet for number and description of SFP modules Connectors Power Terminal Block Electrical RJ45 Indicating LEDs - Optical Link/Data Activity - Power Power Operating Voltage Range CNGE2MC[M]: 8–15 VDC CNGE22MC: 8–15 VDC Power Consumption CNGE2MC[M]: 6W CNGE22MC: 11W Electrical & Mechanical Current Protection Automatic Resettable Solid-State Current Limiters Circuit Board Meets IPC Standard Size ComFit: 6.1 × 5.3 × 1.1 in (15.5 × 13.5 × 2.8 cm) Small Size: 3.3 x 2.5 x 1.1 in. (8.4 x 6.4 x 2.8 cm) Shipping Weight <2 lbs./0.9 kg Environmental MTBF >100,000 hours Operating Temp -40˚ C to +75˚ C Storage Temp -40˚ C to +85˚ C Relative Humidity 0% to 95% (non-condensing)² [1] Multimode fiber needs to meet or exceed fiber standard ITU-T G.651. Single mode fiber needs to meet or exceed fiber standard ITU-T G.652 ORDERING INFORMATION Part Number Description CNGE2MC 2 Port (1 Channel) 10/100/1000 Mbps Ethernet Media Converter CNGE2MCM Small Size 2 Port (1 Channel) 10/100/1000 Mbps Ethernet Media Converter CNGE22MC 4 Port (2 Channel) 10/100/1000 Mbps Ethernet Media Converter Included DC Plug-in Power Supply, 90-264 VAC, 50–60 Hz (Included) Options [2] Add suffix ‘/C’ for Conformally Coated Circuit Boards to extend to condensation conditions (Extra charge, consult factory) DIN-Rail Mounting Adaptor Plate Kit - With Mounting Hardware (Optional, order model DINBKT1) NOTE: This product requires a fiber installation with a minimum 30 dB connector return loss. The use of Super Polish Connectors is recommended. Complies with FDA Performance Standard for Laser Products, Title 21, Code of Federal Regulations, Subchapter J. In a continuing effort to improve and advance technology, product specifications are subject to change without notice. TYPICAL APPLICATION CNGE2MC w/ SFP-6 CNGE2MC w/ SFP-6E E OPTICAL FIBER CAT5 LEGEND DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA LIFETIME WARRANTY WWW.COMNET.NET TECH SUPPORT: 1.888.678.9427 FEATURES › 10/100/1000 Mbps Ethernet • 10/100/1000 BASE-T/TX electrical port • 1000 BASE-FX optical port › Electrical port supports Auto-Negotiation for 10 Mbps, 100 Mbps or 1000 Mbps, full duplex or half duplex data. › Optical port supports 1000 Mbps full duplex data › IEEE 802.3at Class 1 – 4 Power over Ethernet (PoE) › Automatic MDI/MDI-X crossover › Distances up to 120 km with optional SFPs › Designed to meet full compliance with the environmental requirements (ambient operating temperature, mechanical shock, vibration, humidity with condensation, high-line/low- line voltage conditions and transient voltage protection) of NEMA TS-1/TS-2 and the Caltrans Specification for Traffic Signal Control Equipment. › Uses interchangeable SFP for fiber type, distance and connector (Ordered separately) › Voltage transient protection on all power and signal input/ output lines provides unconditional protection from power surges and other voltage transient events. › No in-field optical adjustments required › LED Indicators › IEEE 802.3 compliant APPLICATIONS › 10/100/1000 Mbps Ethernet Media Converter › High Speed Computer Links The ComNet CNGE2MCPOEM Ethernet 2 port media converter is designed to transmit and receive 10/100/1000 Mbps data over optical fiber through user selectable SFP options. The CNGE2MCPOEM transmits and receives a single channel of Ethernet data. It also supports IEEE 802.3at Class 1 – 4 as power sourcing equipment (PSE) with up to 30 Watts of operating power to the remote powered device. It requires the ordering of sold-separately interchangeable SFP modules for fiber type, distance and connectors. Its electrical interface will Auto-Negotiate to a 10 Mbps, 100 Mbps or 1000 Mbps Ethernet rate without any adjustments. The optical interface operates at 1000 Mbps. The CNGE2MCPOEM is environmentally hardened to operate in extreme temperatures. LED indicators are provided for confirming equipment operating status. CNGE2MCPOEM 10/100/1000 Mbps Ethernet 2 Port Media Converter + PoE 1 OR 2CONVERTER802.3atFLEXIBILITYINCLUDED * Small Form-Factor Pluggable Module. Sold separately. -40º TO +75º DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA 01 Aug 2017© 2017 Communication Networks. All Rights Reserved. “ComNet,” the “ComNet Logo,” “NetWave” and the “NetWave Logo” are registered trademarks of Communication Networks. 3 CORPORATE DRIVE | DANBURY, CONNECTICUT 06810 | USA | T: 203.796.5300 | F: 203.796.5303 | TECH SUPPORT: 1.888.678.9427 | INFO@COMNET.NET 8 TURNBERRY PARK ROAD | GILDERSOME | MORLEY | LEEDS, UK LS27 7LE | T: +44 (0)113 307 6400 | F: +44 (0)113 253 7462 | INFO-EUROPE@COMNET.NET CNGE2MCPOEM 10/100/1000 Mbps Ethernet 2 Port Media Converter + PoE SPECIFICATIONS Data Data Interface Ethernet Data Rate 10/100/1000 Mbps IEEE 802.3 Compliant Full Duplex or Half Duplex Electrical Port/Full Duplex Optical Port Electrical 30W (max) Fibers¹ SFP Dependent Fiber Connectors Requires selection of sold-separately SFP modules. See ComNet data sheet for number and description of SFP modules Connectors Power Terminal Block Electrical RJ45 PoE pin assignment RJ45 port #1 supports IEEE 802.3at Class 1 – 4 End-point Positive (VCC+): RJ45 pin 1, 2 Negative (VCC-): RJ45 pin 3, 6 Indicating LEDs - Optical Link/Data Activity - Power - PSE Power Operating Power 48VDC @ 1A Electrical & Mechanical Current Protection: Automatic Resettable Solid-State Current Limiters Circuit Board Meets IPC Standard Size 4.1 × 3.7 × 1.1 in (10.4 × 9.4 × 2.8 cm) Shipping Weight <2 lbs./0.9 kg Environmental MTBF >100,000 hours Operating Temp -40˚ C to +75˚ C Storage Temp -40˚ C to +85˚ C Relative Humidity 0% to 95% (non-condensing)² [1] Multimode fiber needs to meet or exceed fiber standard ITU-T G.651. Single mode fiber needs to meet or exceed fiber standard ITU-T G.652 ORDERING INFORMATION Part Number Description CNGE2MCPOEM 2 Port 10/100/1000 Mbps Ethernet Media Converter with high power Power over Ethernet (PoE) Included 48 Volt DC Plug-in Power Supply, 90-264 VAC, 50/60 Hz (Included) Options [2] Add suffix ‘/C’ for Conformally Coated Circuit Boards to extend to condensation conditions (Extra charge, consult factory) DIN-Rail Mounting Adaptor Plate Kit - With Mounting Hardware (Optional, order model DINBKT1) NOTE: This product requires a fiber installation with a minimum 30 dB connector return loss. The use of Super Polish Connectors is recommended. Complies with FDA Performance Standard for Laser Products, Title 21, Code of Federal Regulations, Subchapter J. In a continuing effort to improve and advance technology, product specifications are subject to change without notice. AGENCY COMPLIANCE TYPICAL APPLICATION CNGE2MC w/ SFP-6 CNGE2MCPOEM w/ SFP-6E E LEGEND 10/100T(X) ETHERNET OPTICAL FIBER 10/100T(X) + PoE DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA SFP Modules Small Form-Factor Pluggable (SFP) Copper and Optical Fiber Transceivers LIFETIME WARRANTY WWW.COMNET.NET TECH SUPPORT: 1.888.678.9427 FEATURES › Interchangeable SFP for fiber type, distance and connector › IEEE 802.3 compliant › Conforms to (SFP) Small Form-Factor Pluggable Multi-Source Agreement (MSA) ›Operating temperature: -40˚ C to +75˚ C ›Storage temperature: -40˚ C to +85˚ C ›No in-field adjustments required ›Lifetime Warranty The ComNet selection of MSA Compliant Small Form-Factor Pluggable (SFP) modules allows for an optical or electrical interface when using a ComNet managed switch, unmanaged switch or media converter. These interchangeable SFP modules are available for use with copper media, multimode optical fiber, or single mode optical fiber. The optical fiber SFP modules are available in Fast Ethernet one and two fiber versions and Gigabit Ethernet one and two fiber versions. They also are available with LC or SC optical connectors. The ComNet SFP modules offer different wavelengths and optical power budget to allow distances from 300 meters to 120 kilometers. These SFP modules are industrially rated to perform in the most difficult operating environments. A ComNet SFP interface is required for use with all ComNet SFP configurable products to qualify for the ComNet Lifetime Warranty. Part number: SFP-SXDocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA SFP Modules Small Form-Factor Pluggable (SFP) Copper and Optical Fiber Transceivers LIFETIME WARRANTY WWW.COMNET.NET TECH SUPPORT: 1.888.678.9427 Product Number Speed (Mbps) Transmission Medium1 TX λ (nm) RX λ (nm)Max. Path Length TX Power (dBm) RX Sensitivity (dBm) Opt. Loss Budget (dBm) Number of Fibers Connector SFP-1 1000 Copper N/A N/A IEEE 802.3 N/A N/A N/A N/A RJ45 SFP-2 100 Multimode 1310 1310 2 km -19 ≤-30 11 2 LC SFP-3 100 Single Mode 1310 1310 20 km -15 ≤-31 16 2 LC SFP-4 100 Single Mode 1310 1310 40 km -14 ≤-34 20 2 LC SFP-5 100 Single Mode 1550 1550 80 km -5 ≤-31 26 2 LC SFP-6 1000 Single Mode 1310 1310 15 km -8 ≤-24 16 2 LC SFP-7 1000 Single Mode 1310 1310 40 km -5 ≤-24 19 2 LC SFP-8 1000 Single Mode 1550 1550 70 km 0 ≤-24 24 2 LC SFP-9 1000 Single Mode 1550 1550 120 km 0 ≤-32 32 2 LC SFP-10A 100 Single Mode 1310 1550 20 km -14 ≤-33 19 1 LC SFP-10B 100 Single Mode 1550 1310 20 km -14 ≤-33 19 1 LC SFP-12A 1000 Single Mode 1310 1550 20 km -8 ≤-22 14 1 LC SFP-12B 1000 Single Mode 1550 1310 20 km -8 ≤-22 14 1 LC SFP-14A 1000 Single Mode 1310 1550 20 km -8 ≤-22 14 1 SC SFP-14B 1000 Single Mode 1550 1310 20 km -8 ≤-22 14 1 SC SFP-16 1000 Multimode 850 850 550 m²-9.5 ≤-17 7.5 2 LC SFP-18A 1000 Single Mode 1310 1550 60 km -1 ≤-26 25 1 LC SFP-18B 1000 Single Mode 1550 1310 60 km -3 ≤-26 23 1 LC SFP-20A 100 Single Mode 1310 1550 60 km -5 ≤-34 29 1 LC SFP-20B 100 Single Mode 1550 1310 60 km -6 ≤-34 28 1 LC SFP-22A 1000 Single Mode 1310 1550 60 km -1 ≤-26 25 1 SC SFP-22B 1000 Single Mode 1550 1310 60 km -3 ≤-26 23 1 SC SFP-24A 100 Single Mode 1310 1550 60 km -5 ≤-34 29 1 SC SFP-24B 100 Single Mode 1550 1310 60 km -6 ≤-34 28 1 SC SFP-26A 100 Multimode 1310 1550 2 km -15 ≤-30 15 1 SC SFP-26B 100 Multimode 1550 1310 2 km -15 ≤-30 15 1 SC SFP-36A 100 Single Mode 1310 1550 20 km -15 ≤-34 19 1 SC SFP-36B 100 Single Mode 1550 1310 20 km -15 ≤-34 19 1 SC SFP-39WIS³100 Single Mode 1310 1310 10 Km -9.5 ≤ 20 10.5 2 LC SFP-46 1000 Multimode 1310 1310 2 km -10 -18 8 2 LC SFP-48A 1000 Multimode 1310 1550 550 m -3 -20 17 1 LC SFP-48B 1000 Multimode 1550 1310 550 m -3 -20 17 1 LC SFP-SX³1000 Multimode 850 850 550 m²-9.5 ≤-17 7.5 2 LC SFP-LX3.4 1000 Single Mode 1310 1310 10 km -9.5 ≤-20 10.5 2 LC SFP-LH3.4 1000 SM & MM 1310 1310 20 km / 550 m²-3 ≤-20 17 2 LC SFP-ZX³ 1000 Single Mode 1550 1550 70 km 0 ≤-23 23 2 LC SFP-BXU³ 1000 Single Mode 1310 1490 10 km -9 ≤-19.5 10.5 1 LC SFP-BXD³1000 Single Mode 1490 1310 10 km -9 ≤-19.5 10.5 1 LC SFP-LX/C4 1000 Single Mode 1310 1310 10 km²-9.5 ≤-20 10.5 2 LC SFP-10G-SR 10000 Multimode 850 850 OM2 - 26 m/ OM3 - 300 m -3.5 -8 4.5 2 LC SFP-10G-LRM 10000 Multimode 1310 1310 OM2 - 220 m -4 -7 3 2 LC SFP-10G-LR 10000 Single Mode 1310 1310 10 km -3 -11 8 2 LC SFP-10G-ER 10000 Single Mode 1550 1550 40 km 0 -12 12 2 LC SFP-10G-ZR 10000 Single Mode 1550 1550 80 km +2 -20 22 2 LC SFP-10G-BX10-U 10000 Single Mode 1270 1330 10 km -3 -11 8 1 LC SFP-10G-BX10-D 10000 Single Mode 1330 1270 10 km -3 -11 8 1 LC SFP-10G-BX40-U 10000 Single Mode 1270 1330 40 km 0 -12 12 1 LC SFP-10G-BX40-D 10000 Single Mode 1330 1270 40 km 0 -12 12 1 LC [1] Multimode fiber needs to meet or exceed fiber standard ITU-T G.651. Single mode fiber needs to meet or exceed fiber standard ITU-T G.652. Only optical patch cords with PC or UPC connectors are supported unless otherwise stated. [2] 550 m using laser-optimized 50/125 µm fiber; 300 m using 62.5/125 µm fiber. [3] ComNet SFP modules will optically communicate with properly matched Cisco SFPs when Cisco SFPs are installed in a Cisco switch. Note that ComNet SFPs will not operate when installed in a Cisco switch. [4] The SFP module is compatible with all Cisco based routers and switches, as well as Cisco IOS software. This is not a Cisco OEM brand module. Complies with FDA Performance Standard for Laser Products, Title 21, Code of Federal Regulations, Subchapter J In a continuing effort to improve and advance technology, product specifications are subject to change without notice. AGENCY COMPLIANCE SPECIFICATIONS AND ORDERING INFORMATION DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA SFP Modules Small Form-Factor Pluggable (SFP) Copper and Optical Fiber Transceivers LIFETIME WARRANTY WWW.COMNET.NET TECH SUPPORT: 1.888.678.9427 COMPATIBILITY INFORMATION 1000 Mbps SFP Model (SFP-1) Compatibility* ComNet Ethernet Model SFP -1 CNGE4US • CNGE8US • * SFP-1 is intended for use with the indicated ComNet products. They may function in other products, but only where both ends are capable of 1 Gbps speed. Devices connected to the RJ-45 port must support 1000BASE-T Ethernet standard. Contact our Design Center if you have any questions about using this SFP Model in your application. 100 Mbps SFP Model Compatibility ComNet Ethernet Model SFP-2 SFP- 3 SFP- 4 SFP- 5 SFP- 10A SFP- 10B SFP- 20A SFP- 20B SFP- 24A SFP- 24B SFP- 26A SFP- 26B SFP- 36A SFP- 36B SFP- 39WIS CNGE3FE7MS2 ••••••••••••••• CNGE3FE7MS3 ••••••••••••••• CNGE3FE7MS4 ••••••••••••••• CNGE2FE8MSPOE ••••••••••••••• CNGE2FE8MSPOE+••••••••••••••• CNGE2FE16MS ••••••••••••••• CNGE8FX4TX4MS ••••••••••••••• CNGE5MS ••••••••••••••• CNGE8MS ••••••••••••••• CNGE12MS ••••••••••••••• CNGE20MS ••••••••••••••• CNGE24MS ••••••••••••••• CNGE28FX4TX24MSPOE2/48 ••••••••••••••• RLGE20FX4TX16MS(LV,HV)••••••••••••••• RLXE4GE24MODMS/8SFP ••••••••••••••• RL1000GW/ESFP ••••••••••••••• RLGE2FE16R ••••••••••••••• CWGE2FE8MSPOE ••••••••••••••• CWGE2FE24MODMS/8SFP ••••••••••••••• CWGE24MS ••••••••••••••• CWGE26FX2TX24MSPOE ••••••••••••••• CNGE2+2SMS[POE][HO]••••••••••••••• CNFE8FX8US ••••••••••••••• CNFE8FX4TX4US ••••••••••••••• CNFE4FX2TX2US ••••••••••••••• CNFE4FX4US ••••••••••••••• FE2MC-B ••••••••••••••• CNFE2MC ••••••••••••••• CNFE2MC[AC]-M ••••••••••••••• CNFE22MC ••••••••••••••• CNFE2MC2C[/M]••••••••••••••• CNMCSFP/M ••••••••••••••• CNMCSFP ••••••••••••••• CNMC2SFP ••••••••••••••• RLMCSFP ••••••••••••••• CWFESFPMCPOE30/M ••••••••••••••• CWFESFPMCPOE60/M ••••••••••••••• CNFESFPMCPOE30/M ••••••••••••••• CNFESFPMCPOE60/M ••••••••••••••• CNFE2MCPOE[2][/M]••••••••••••••• CNMC[2]SFPPOE[/M]••••••••••••••• CNFE2DOE2 ••••••••••••••• CNFE8TCOE ••••••••••••••• CNFE8RCOE ••••••••••••••• DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA SFP Modules Small Form-Factor Pluggable (SFP) Copper and Optical Fiber Transceivers LIFETIME WARRANTY WWW.COMNET.NET TECH SUPPORT: 1.888.678.9427 1000 Mbps SFP Model Compatibility SFP-6 SFP-7 SFP-8 SFP-9 SFP-12A SFP-12B SFP-14A SFP-14B SFP-16 SFP-18A SFP-18B SFP-22A SFP-22B SFP-46 SFP-48A SFP-48B CNGE3FE7MS2 •••••••••••••••• CNGE3FE7MS3 •••••••••••••••• CNGE3FE7MS4 •••••••••••••••• CNGE2FE8MSPOE •••••••••••••••• CNGE2FE8MSPOE+•••••••••••••••• CNGE2FE16MS •••••••••••••••• CNGE8FX4TX4MS •••••••••••••••• CNGE5MS •••••••••••••••• CNGE8MS •••••••••••••••• CNGE12MS •••••••••••••••• CNGE20MS •••••••••••••••• CNGE24MS •••••••••••••••• CNGE2FE24MS •••••••••••••••• CNGE2FE24MSPOE •••••••••••••••• CNGE28FX4TX24MS •••••••••••••••• CNGE28FX4TX24MSPOE •••••••••••••••• CNGE28FX4TX24MSPOE2/48 •••••••••••••••• RLGE20FX4TX16MS(LV,HV)•••••••••••••••• RLXE4GE24MODMS/1G4SFP •••••••••••••••• RLXE4GE24MODMS/8SFP •••••••••••••••• RL1000GW/ESFP •••••••••••••••• RLGE2FE16R •••••••••••••••• CWGE2FE8MSPOE •••••••••••••••• CWGE2FE8MSPOE+•••••••••••••••• CWGE9MS •••••••••••••••• CWGE2FE24MODMS/CHASSIS •••••••••••••••• CWGE24MODMS •••••••••••••••• CWGE24MS •••••••••••••••• CWGE28FX4TX24MS •••••••••••••••• CWGE26FX2TX24MSPOE •••••••••••••••• CNGE2FE4SMS[POE][HO]•••••••••••••••• CNGE2+2SMS[POE][HO]•••••••••••••••• CNGE4US •••••••••••••••• CNGE8US •••••••••••••••• CNGE2MC •••••••••••••••• CNGE2MC-M •••••••••••••••• CNGE22MC •••••••••••••••• CNMCSFP/M •••••••••••••••• CNMCSFP •••••••••••••••• CNMC2SFP •••••••••••••••• CNGE2MCPOEM •••••••••••••••• CNMC[2]SFPPOE[/M]•••••••••••••••• RLMCSFP •••••••••••••••• FVT/FVR40SFP •••••••••••••••• FVT/FVR80SFP •••••••••••••••• FVT/FVR40D2SFP •••••••••••••••• FVT/FVR40D4SFP •••••••••••••••• FVT/FVR80D2SFP •••••••••••••••• FVT/FVR80D4SFP •••••••••••••••• FVT/FVR80D8SFP •••••••••••••••• FVT/FVR8SFP2R •••••••••••••••• FVT/FVR8SFP2RD8 •••••••••••••••• FVT/FVR10D2I1C4E •••••••••••••••• FVT/FVR20D2I1C4E •••••••••••••••• FVT/FVR40D2I1C4E •••••••••••••••• DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA SFP Modules Small Form-Factor Pluggable (SFP) Copper and Optical Fiber Transceivers LIFETIME WARRANTY WWW.COMNET.NET TECH SUPPORT: 1.888.678.9427 1000 Mbps SFP Cisco-Match Model Compatibility SFP-SX SFP-LX SFP-LH SFP-ZX SFP-BXU SFP-BXD CNGE3FE7MS2 •••••• CNGE3FE7MS3 •••••• CNGE3FE7MS4 •••••• CNGE2FE8MSPOE •••••• CNGE2FE8MSPOE+•••••• CNGE2FE16MS •••••• CNGE8FX4TX4MS •••••• CNGE5MS •••••• CNGE8MS •••••• CNGE12MS •••••• CNGE20MS •••••• CNGE24MS •••••• CNGE2FE24MS •••••• CNGE2FE24MSPOE •••••• CNGE28FX4TX24MS •••••• CNGE28FX4TX24MSPOE •••••• CNGE28FX4TX24MSPOE2/48 •••••• RLGE20FX4TX16MS(LV,HV)•••••• RLXE4GE24MODMS/1G4SFP •••••• RLXE4GE24MODMS/8SFP •••••• RL1000GW/ESFP •••••• RLGE2FE16R •••••• CWGE2FE8MSPOE •••••• CWGE2FE8MSPOE+•••••• CWGE9MS •••••• CWGE2FE24MODMS/CHASSIS •••••• CWGE24MODMS •••••• CWGE24MS •••••• CWGE28FX4TX24MS •••••• CWGE26FX2TX24MSPOE •••••• CNGE2FE4SMS[POE][HO]•••••• CNGE2+2SMS[POE][HO]•••••• CNGE4US •••••• CNGE8US •••••• CNGE2MC •••••• CNGE2MC-M •••••• CNGE22MC •••••• CNMCSFP/M •••••• CNMCSFP •••••• CNMC2SFP •••••• CNGE2MCPOEM •••••• CNMC[2]SFPPOE[/M]•••••• RLMCSFP •••••• FVT/FVR40SFP •••••• FVT/FVR80SFP •••••• FVT/FVR40D2SFP •••••• FVT/FVR40D4SFP •••••• FVT/FVR80D2SFP •••••• FVT/FVR80D4SFP •••••• FVT/FVR80D8SFP •••••• FVT/FVR8SFP2R •••••• FVT/FVR8SFP2RD8 •••••• FVT/FVR10D2I1C4E •••••• FVT/FVR20D2I1C4E •••••• FVT/FVR40D2I1C4E •••••• DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA SFP Modules Small Form-Factor Pluggable (SFP) Copper and Optical Fiber Transceivers 19 Dec 2019© 2019 Communication Networks. All Rights Reserved. “ComNet” and the “ComNet Logo” are registered trademarks of Communication Networks. 3 CORPORATE DRIVE | DANBURY, CONNECTICUT 06810 | USA | T: 203.796.5300 | F: 203.796.5303 | TECH SUPPORT: 1.888.678.9427 | INFO@COMNET.NET 8 TURNBERRY PARK ROAD | GILDERSOME | MORLEY | LEEDS, UK LS27 7LE | T: +44 (0)113 307 6400 | F: +44 (0)113 253 7462 | INFO-EUROPE@COMNET.NET 10 Gbps (10000 Mbps) SFP Model Compatibility ComNet Ethernet Model SFP-10G-SR SFP-10G-LRM SFP-10G-LR SFP-10G-ER SFP-10G-ZR SFP-10G-BX10-U SFP-10G-BX10-D SFP-10G-BX40-U SFP-10G-BX40-D RLXE4GE24MODMS/XE2SFP ••••••••• RLXE4GE24MODMS/XE4SFP ••••••••• CopperLine® Extended Distance SFP Model Compatibility Please see the CL-SFP Data Sheet for more information ComNet Ethernet Model CL-SFP 1 CL-SFP3 CNGE3FE7MS2 •• CNGE3FE7MS3 •• CNGE3FE7MS4 •• CNGE2FE8MSPOE •• CNGE2FE8MSPOE+•• CNGE2FE16MS •• CNGE8FX4TX4MS •• CNGE5MS •• CNGE8MS •• CNGE12MS •• CNGE20MS •• CNGE24MS •• CNGE28FX4TX24MSPOE2/48 •• RLGE20FX4TX16MS(LV,HV)•• RLXE4GE24MODMS/8SFP •• RLGE2FE16R •• CWGE2FE8MSPOE •• CWGE2FE24MODMS/8SFP •• CWGE24MS •• CWGE28FX4TX24MS •• CWGE26FX2TX24MSPOE •• CNGE2+2SMS[POE][HO]•• CNFE8FX8US •• CNFE8FX4TX4US •• CNFE4FX2TX2US •• CNFE4FX4US •• FE2MC-B •• CNFE2MC •• CNFE2MC[AC]-M •• CNFE22MC •• CNFE2MC2C[/M]•• CNMCSFP/M •• CNMCSFP •• CNMC2SFP •• RLMCSFP •• CWFESFPMCPOE30/M •• CWFESFPMCPOE60/M •• CNFESFPMCPOE30/M •• CNFESFPMCPOE60/M •• CNFE2MCPOE[2][/M]•• CNMC[2]SFPPOE[/M]•• CNFE2DOE2 •• CNFE8TCOE •• CNFE8RCOE •• DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA 3 YEAR WARRANTY WWW.COMNET.NET TECH SUPPORT: 1.888.678.9427 FEATURES › Universal AC input: 90 to 264 VAC, 47-63Hz › Mounts on standard 7.5 or 15 mm DIN-rail › Adjustable output voltage range support › High operating efficiency; up to 89% › Small package for limited space installations › Natural convection cooling; no troublesome fans › Wide operating temperature range: -40º to +71º C › 3 Year Warranty APPLICATIONS › Power Supplies for ComNet Industrial Products The ComNet™ PS-AMR Series offer a complete range of high quality, low noise switching mode power supplies of various output sizes ideally suited to the entire ComNet industrial product range that require either 12 or 24VDC power input. These rugged units are DIN rail mountable, providing an ideal mounting configuration to a mating ComNet industrial switch or any product using our range of DIN rail mounting adapters. The wide ambient operating temperature range permits installation in most out of plant and unconditioned environments, such as those found in intelligent transportation systems or factory automation/industrial control applications. Unconditional line and load protection is provided. PS-AMR Series Industrial DIN Rail Mounting 12 or 24 Volt Power Supplies DIN RAILHARDENED12 OR 24 V DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA 3 YEAR WARRANTY WWW.COMNET.NET TECH SUPPORT: 1.888.678.9427 PS-AMR Series Industrial DIN Rail Mounting 12 or 24 Volt Power Supplies SPECIFICATIONS All Specifications Typical at Nominal Line, Full Load, 25ºC Unless Otherwise Noted Power Input Rated Input Voltage 90 to 264 VAC or 120 to 375 VDC Input Current 115 / 230 VAC PS-AMR1-12: 200 / 135 mA PS-AMR2-12: 450 / 270 mA PS-AMR3-12: 680 / 410 mA PS-AMR4-12: 1.1 / 0.6 A PS-AMR5-12: 1.35 / 0.72 A PS-AMR1-24: 1.35 / 0.72 A PS-AMR2-24: 450 / 270 mA PS-AMR3-24: 680 / 410 mA PS-AMR5-24: 1.8 / 0.9 A PS-AMR4-24: 1.1 / 0.6 A Line Frequency 47 to 63 Hz Inrush current 115 / 230 VAC PS-AMR1: 15 / 30 A PS-AMR2: 20 / 40 A PS-AMR3: 25 / 50 A PS-AMR4/5: 30 / 60 A Power Dissipation 230 VAC PS-AMR1-12: 2.3 W PS-AMR2-12: 4.3 W PS-AMR3-12: 7.3 W PS-AMR4-12: 10.2 W PS-AMR5-12: 12. 9 W PS-AMR1-24: 2.3 W PS-AMR2-24: 4.0 W PS-AMR3-24: 7.1 W PS-AMR424: 9.9 W PS-AMR5-24: 12. 2 W Power Input Voltage Accuracy +1% Minimum Load 0% Line Regulation ±1% Voltage Trim Range For all except the PS-AMR1 models 12 V: 12 to 14 VDC 24 V: 24 to 28 VDC Hold up time 115 / 230 VAC PS-AMR1: 10 / 30 ms PS-AMR2: 20 / 80 ms PS-AMR3: 20 / 100 ms PS-AMR4-12: 16 / 60 ms PS-AMR5-12: 16 / 60 ms PS-AMR4-24: 12 / 60 ms PS-AMR5-24: 10 / 60 ms DC ON / LOW indicator threshold 12 V: 9 to 10.8 VDC 24 V: 19.2 to 21.6 VDC General Isolation Resistance Input-Output, @ 500VDC, 100 MΩ Derating PS-AMR1/2/5: +61º to 71ºC, max 2.5% / ºC PS-AMR3/4: +56º to 71ºC, max 2.5% / ºC Cooling Normal convection (Recommend all sides 25m/m free space) Control and Protection Input fuse 250 VAC internal PS-AMR1: T1A PS-AMR2/3/4: T2A PS-AMR5: T3.15A Internal Surge Protection IEC 61000-4-5 Rated Over Load Protection PS-AMR1: 110 - 165 % PS-AMR2: 120 - 160 % PS-AMR3/4/5: 110 - 150 % Over voltage protection Auto Recovery 12 V: 15 to 16.5 VDC 24 V: 30 to 33 VDC Degree of protection IP20 Connector AWG24-12 (0.2 - 2.5mm²) flexible / solid cable Indicating LEDs DC ON At Start Up (Green) DC LOW After Start Up (Red) Electrical & Mechanical Size PS-AMR1 3.58 × 0.71 × 2.22 in (9.1 × 1.8 × 5.65 cm) PS-AMR2 3.58 × 1.38 × 2.22 in (9.1 × 3.5 × 5.65 cm) PS-AMR3 3.58 × 2.09 × 2.22 in (9.1 × 5.3 × 5.65 cm) PS-AMR4 3.58 × 2.8 × 2.22 in (9.1 × 7.1 × 5.65 cm) PS-AMR5 3.58 × 3.54 × 2.24 in (9.1 × 9.0 × 5.7 cm) Weight PS-AMR1 0.14 lb / 65 g PS-AMR2 0.29 lb / 130 g PS-AMR3 0.42 lb / 190 g PS-AMR4 0.55 lb / 250 g PS-AMR5 0.84 lb/ 380 g Environmental MTBF >500,000 hours @ 40ºC Operating Temp -40˚ C to +71˚ C Storage Temp -40˚ C to +85˚ C Relative Humidity 20% to 90% (non-condensing) Approvals & EMC Compliance UL / cUL UL 508 Listed UL 60950-I, UL 1310 Class 2 Power (24LS model only) recognized ISA 12.12.01 (Class I, Div 2, Groups A, B, C, & D) TUV EN 60950-I, CB scheme CE EN 61000-6-3, EN 55022 Class B, EN 61000-3-2, EN 61000-3-3, EN 61000-6-2, EN 55024, EN 61000-4-2 Level 4, EN 61000-4-3 Level 3, EN 61000-4-4-4 Level 4, EN 61000-4-5 L-N Level 3, EN 61000-4-6 Level 3, EN 61000-4-8 Level 4, EN 61000-4-11, ENV 50204 Level 2, EN 61204-3 Vibration Meets IEC 60068-2-6 Rail Mount: 10 - 500 Hz, 2G, 60 min for each Axis Shock Meets IEC 60068-2-27 15G, 11ms, 3 Axis, 6 Faces, 3 times for each Face DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA 06 Nov 2014© 2014 Communication Networks. All Rights Reserved. “ComNet,” the “ComNet Logo,” “NetWave” and the “NetWave Logo” are registered trademarks of Communication Networks. 3 CORPORATE DRIVE | DANBURY, CONNECTICUT 06810 | USA | T: 203.796.5300 | F: 203.796.5303 | TECH SUPPORT: 1.888.678.9427 | INFO@COMNET.NET 8 TURNBERRY PARK ROAD | GILDERSOME | MORLEY | LEEDS, UK LS27 7LE | T: +44 (0)113 307 6400 | F: +44 (0)113 253 7462 | INFO-EUROPE@COMNET.NET PS-AMR Series Industrial DIN Rail Mounting 12 or 24 Volt Power Supplies PIN ASSIGNMENTS DERATING CURVES PS-AMR1 PIN Designation Description 1 OUT-Negative output terminal 2 +Positive output terminal 3 INL Input terminals (phase conductor, no polarity at DC input) 4 N Input terminals (neutral conductor, no polarity at DC input)OTHERDC ON Operation indicator LED DC LO DC Low indicator LED PS-AMR1/2/5 PS-AMR3/4 PS-AMR2/3/4/5 PIN Designation Description 1 OUT-Negative output terminal 2 -Negative output terminal 3 +Positive output terminal 4 +Positive output terminal 5 INL Input terminals (phase conductor, no polarity at DC input) 6 N Input terminals (neutral conductor, no polarity at DC input)OTHERVout ADJ.Trimmer-potentiometer for Vout adjustment DC ON Operation indicator LED DC LO DC Low indicator LED ORDERING INFORMATION Part Number Input Voltage Output Wattage Output Voltage Output Current Eff. (min)Eff. (typ) PS-AMR1-12 90 to 264 VAC 10 Watts + 12 VDC 830 mA 76%78% PS-AMR2-12 90 to 264 VAC 24 Watts + 12 VDC 2000 mA 82%84% PS-AMR3-12 90 to 264 VAC 33 Watts + 12 VDC 2750 mA 80%80% PS-AMR4-12 90 to 264 VAC 54 Watts + 12 VDC 4500 mA 82% 84% PS-AMR5-12 90 to 264 VAC 72 Watts + 12 VDC 6000 mA 83%86% PS-AMR1-24 90 to 264 VAC 10 Watts + 24 VDC 420 mA 78%80% PS-AMR2-24 90 to 264 VAC 24 Watts + 24 VDC 1000 mA 83%85% PS-AMR3-24 90 to 264 VAC 36 Watts + 24 VDC 1500 mA 81%84% PS-AMR4-24 90 to 264 VAC 60 Watts + 24 VDC 2500 mA 84%86% PS-AMR5-24 90 to 264 VAC 100 Watts + 24 VDC 4200 mA 86%89%Power Out (%)Temperature (ºC) 100 75 0 -40 61 71 Power Out (%)Temperature (ºC) 100 62.5 -40 56 71 0 DocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA 11223344AABBCCDDSHEET 1 OF 2 DRAWNCHECKEDQAMFGAPPROVEDCAHCAHCAHCAH5/4/20225/4/20225/4/20225/4/2022DWG NO1026-XXTITLEModel 1026-XXSIZECSCALEREV11TOLERANCE: .0 = +/- .030 .00 = +/- .015 .000 = +/- .005 Oberon, Inc. - 1315 S. Allen St. - State College, PA 16801REVISION HISTORYZONEREVDESCRIPTIONDATEAPPROVEDAll 1 Released1/11/2012MDAAll 2Added ABS Mounting Plate12/4/2014EASAll3 Added size chart and includes list4/20/2016EASAll4Updated Notes, "Includes" List, and Configuration Table; Changed Title to "Model 1026-XX"7/31/2020CAHAll5Updated Notes9/23/2020CAHAll6Updated Configuration Table6/8/2021CAHAll7Updated "Includes" List7/22/2021CAHAll8Updated "Includes" List; Added Exploded View7/27/2021CAHAll9Updated "Includes" List8/3/2021CAHAll10Updated "Includes" List 1/11/2022CAHAll11Updated Notes, "Includes" List, and Configuration Table 5/4/2022CAHNOTES:- Material: UL94-5VA Light Gray Polycarbonate Plastic Enclosure Base UL94-5VA Light Gray Polycarbonate Plastic Enclosure Door (For -00 SKUs Only) UL94-V0 Tinted Clear Polycarbonate Plastic Enclosure Door (For -C SKUs Only) UL94-5VA Black ABS Plastic Universal Mounting Panel UL94-5VA Light Gray Polycarbonate Plastic Mounting Feet (For All SKUs Except -18164 or -242410) Includes:- (1) Enclosure- (1) Universal Mounting Panel- (4) Mounting Feet (For All SKUs Except -18164 or -242410)- (4) 1/4"-20 x 1/2 in. Mounting Feet Screws (For All SKUs Except -18164 or -242410)- (4) #10 x 3/8 in. Mounting Panel Screws- (4) #10 x 5/8 in. Lid ScrewsUNIVERSAL MOUNTING PANELMOUNTING FEETPart Number: 1026-12106-CDocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA 11223344AABBCCDDSHEET 2 OF 2 DRAWNCHECKEDQAMFGAPPROVEDCAHCAHCAHCAH5/4/20225/4/20225/4/20225/4/2022DWG NO1026-XXTITLEModel 1026-XXSIZECSCALEREV11TOLERANCE: .0 = +/- .030 .00 = +/- .015 .000 = +/- .005 Oberon, Inc. - 1315 S. Allen St. - State College, PA 16801Configuration TableMODEL NUMBERHEIGHT (H)WIDTH (W)DEPTH (D)BASE DEPTH (BD)1026-1084-00 11.41 in. 9.41 in. 5.89 in. 4.70 in.1026-1084-C 11.41 in. 9.41 in. 5.89 in. 4.70 in.1026-12106-00 13.41 in. 11.41 in. 7.38 in. 6.20 in.1026-12106-C 13.41 in. 11.41 in. 7.38 in. 6.20 in.1026-14126-00 15.40 in. 13.40 in. 7.39 in. 6.20 in.1026-14126-C 15.40 in. 13.40 in. 7.39 in. 6.20 in.1026-16148-00 17.41 in.15.41 in.9.40 in. 8.20 in.1026-16148-C 17.41 in. 15.41 in. 9.40 in. 8.20 in.1026-18164-00 19.40 in. 17.41 in. 5.41 in. 4.20 in.1026-18164-C 19.40 in. 17.41 in.5.41 in.4.20 in.1026-181610-00 19.41 in. 17.41 in. 11.41 in. 10.20 in.1026-181610-C 19.41 in. 17.41 in. 11.41 in. 10.20 in.1026-20168-00 21.41 in. 17.41 in. 9.47 in. 8.26 in.1026-20168-C 21.41 in. 17.41 in. 9.47 in. 8.26 in.1026-242410-00 25.41 in. 25.41 in. 11.41 in. 10.20 in.1026-242410-C 25.41 in. 25.41 in. 11.41 in. 10.20 in.WHBDDISOMETRIC VIEWDocuSign Envelope ID: 8E8C53C2-B715-4F22-B187-C6BD47063FFA Certificate Of Completion Envelope Id: 8E8C53C2B7154F22B187C6BD47063FFA Status: Completed Subject: Complete with DocuSign: 8405 Ladera Linda CCO 39_rev2.pdf Source Envelope: Document Pages: 54 Signatures: 2 Envelope Originator: Certificate Pages: 5 Initials: 1 James O'Neill AutoNav: Enabled EnvelopeId Stamping: Enabled Time Zone: (UTC-08:00) Pacific Time (US & Canada) 30940 Hawthorne Blvd. Rancho Palos Verdes, CA 90275 joneill@rpvca.gov IP Address: 72.34.97.146 Record Tracking Status: Original 8/15/2023 3:12:09 PM Holder: James O'Neill joneill@rpvca.gov Location: DocuSign Signer Events Signature Timestamp Ramzi Awwad rawwad@rpvca.gov Director of Public Works City of Rancho Palos Verdes Security Level: Email, Account Authentication (None) Signature Adoption: Drawn on Device Using IP Address: 104.174.65.192 Sent: 8/15/2023 3:19:35 PM Viewed: 8/15/2023 3:31:26 PM Signed: 8/15/2023 3:31:35 PM Electronic Record and Signature Disclosure: Accepted: 3/2/2023 10:45:19 AM ID: 3242b72d-4755-489d-8e5f-7c62dc360470 Brittany Ruiz bruiz@rpvca.gov Interim Director of Finance City of Rancho Palos Verdes Security Level: Email, Account Authentication (None) Signature Adoption: Pre-selected Style Using IP Address: 47.153.166.108 Sent: 8/15/2023 3:31:38 PM Viewed: 8/16/2023 2:34:39 PM Signed: 8/16/2023 2:35:05 PM Electronic Record and Signature Disclosure: Not Offered via DocuSign Ara Mihranian aram@rpvca.gov City Manager City of Rancho Palos Verdes Security Level: Email, Account Authentication (None) Signature Adoption: Uploaded Signature Image Using IP Address: 72.34.97.146 Sent: 8/16/2023 2:35:09 PM Viewed: 8/16/2023 5:44:13 PM Signed: 8/16/2023 5:44:42 PM Electronic Record and Signature Disclosure: Not Offered via DocuSign In Person Signer Events Signature Timestamp Editor Delivery Events Status Timestamp Agent Delivery Events Status Timestamp Intermediary Delivery Events Status Timestamp Certified Delivery Events Status Timestamp Carbon Copy Events Status Timestamp Carbon Copy Events Status Timestamp Erin Jones ejones@griffinstructures.com Security Level: Email, Account Authentication (None) Sent: 8/16/2023 5:44:45 PM Viewed: 8/17/2023 8:13:47 AM Electronic Record and Signature Disclosure: Not Offered via DocuSign Lorna Cloke lornac@rpvca.gov Security Level: Email, Account Authentication (None) Sent: 8/16/2023 5:44:46 PM Electronic Record and Signature Disclosure: Not Offered via DocuSign City Clerk cityclerk@rpvca.gov Security Level: Email, Account Authentication (None) Sent: 8/16/2023 5:44:47 PM Viewed: 8/17/2023 9:47:10 AM Electronic Record and Signature Disclosure: Accepted: 2/1/2023 3:10:58 PM ID: 505eed45-7ed0-4db8-aae6-ef6eedfef03d Witness Events Signature Timestamp Notary Events Signature Timestamp Envelope Summary Events Status Timestamps Envelope Sent Hashed/Encrypted 8/15/2023 3:19:35 PM Certified Delivered Security Checked 8/16/2023 5:44:13 PM Signing Complete Security Checked 8/16/2023 5:44:42 PM Completed Security Checked 8/16/2023 5:44:47 PM Payment Events Status Timestamps Electronic Record and Signature Disclosure ELECTRONIC RECORD AND SIGNATURE DISCLOSURE From time to time, City of Rancho Palos Verdes (we, us or Company) may be required by law to provide to you certain written notices or disclosures. Described below are the terms and conditions for providing to you such notices and disclosures electronicall y through the DocuSign system. Please read the information below carefully and thoroughly, and if you can access this information electronically to your satisfaction and agree to this Electronic Record and Signature Disclosure (ERSD), please confirm your agreement by selecting the check-box next to ‘I agree to use electronic records and signatures’ before clicking ‘CONTINUE’ within the DocuSign system. Getting paper copies At any time, you may request from us a paper copy of any record provided or made av ailable electronically to you by us. You will have the ability to download and print documents we send to you through the DocuSign system during and immediately after the signing session and, if you elect to create a DocuSign account, you may access the documents for a limited period of time (usually 30 days) after such documents are first sent to you. After such time, if you wish for us to send you paper copies of any such documents from our office to you, you will be charged a $0.00 per-page fee. You may request delivery of such paper copies from us by following the procedure described below. Withdrawing your consent If you decide to receive notices and disclosures from us electronically, you may at any time change your mind and tell us that thereafter you want to receive required notices and disclosures only in paper format. How you must inform us of your decision to receive future notices and disclosure in paper format and withdraw your consent to receive notices and disclosures electronically is described below. Consequences of changing your mind If you elect to receive required notices and disclosures only in paper format, it will slow the speed at which we can complete certain steps in transactions with you and delivering services to you because we will need first to send the required notices or disclosures to you in paper format, and then wait until we receive back from you your acknowledgment of your receipt of such paper notices or disclosures. Further, you will no longer be able to use the DocuSign system to receive required notices and consents electronically from us or to sign electronically documents from us. All notices and disclosures will be sent to you electronically Electronic Record and Signature Disclosure created on: 6/15/2021 5:55:39 PM Parties agreed to: Ramzi Awwad, City Clerk Unless you tell us otherwise in accordance with the procedures described herein, we will provide electronically to you through the DocuSign system all required notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to you during the course of our relationship with you. To reduce the chance of you inadvertently not receiving any notice or disclosure, we prefer to provide all of the required notices and disclosures to you by the same method and to the same address that you have given us. Thus, you can receive all the disclosures and notices electronically or in paper format through the paper mail delivery system. If you do not agree with this process, please let us know as described below. Please also see the paragraph immediately above that describes the consequences of your electing not to receive delivery of the notices and disclosures electronically from us. How to contact City of Rancho Palos Verdes: You may contact us to let us know of your changes as to how we may contact you electronically, to request paper copies of certain information from us, and to withdraw your prior consent to receive notices and disclosures electronically as follows: To contact us by email send messages to: terit@rpvca.gov To advise City of Rancho Palos Verdes of your new email address To let us know of a change in your email address where we should send notices and disclosures electronically to you, you must send an email message to us at terit@rpvca.gov and in the body of such request you must state: your previous email address, your new email address. We do not require any other information from you to change your email address. If you created a DocuSign account, you may update it with your new email address through your account preferences. To request paper copies from City of Rancho Palos Verdes To request delivery from us of paper copies of the notices and disclosures previously provided by us to you electronically, you must send us an email to terit@rpvca.gov and in the body of such request you must state your email address, full name, mailing address, and telephone number. We will bill you for any fees at that time, if any. To withdraw your consent with City of Rancho Palos Verdes To inform us that you no longer wish to receive future notices and disclosures in electronic format you may: i. decline to sign a document from within your signing session, and on the subsequent page, select the check-box indicating you wish to withdraw your consent, or you may; ii. send us an email to terit@rpvca.gov and in the body of such request you must state your email, full name, mailing address, and telephone number. We do not need any other information from you to withdraw consent.. The consequences of your withdrawing consent for online documents will be that transactions may take a longer time to process.. Required hardware and software The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found here: https://support.docusign.com/guides/signer-guide- signing-system-requirements. Acknowledging your access and consent to receive and sign documents electronically To confirm to us that you can access this information electronically, which will be similar to other electronic notices and disclosures that we will provide to you, please confirm that you have read this ERSD, and (i) that you are able to print on paper or electronically save this ERSD for your future reference and access; or (ii) that you are able to email this ERSD to an email address where you will be able to print on paper or save it for your future reference and access. Further, if you consent to receiving notices and disclosures exclusively in electronic format as described herein, then select the check-box next to ‘I agree to use electronic records and signatures’ before clicking ‘CONTINUE’ within the DocuSign system. By selecting the check-box next to ‘I agree to use electronic records and signatures’, you confirm that:  You can access and read this Electronic Record and Signature Disclosure; and  You can print on paper this Electronic Record and Signature Disclosure, or save or send this Electronic Record and Disclosure to a location where you can print it, for future reference and access; and  Until or unless you notify City of Rancho Palos Verdes as described above, you consent to receive exclusively through electronic means all notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to you by City of Rancho Palos Verdes during the course of your relationship with City of Rancho Palos Verdes.